Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance INSIDE KL PARK W NO 37 IN MOGA CITY | Admitted-Finance |
| 2 | Admitted-Finance ARRORIAN STREET DISTT PATIALA | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Not Qualified |
Tender Value
₹12.2 L
EMD Value
₹24,378
Closing Date
1 Jul 2022, 11:00 amClosed
Executive Engineer
Water Works Complex, Near SDM Office, Khanna
PROVIDING AND INSTALLING NEW TW 200mm id STRAIGHT UPTO 150 MTR. DEPTH, AGAINST FAILED OLD TW WITH REVERSE ROTARY RIG., GRAVEL PIT, PUMPING MACHINERY AND RISING MAIN ETC. AT VILLAGE SIHORA 2 NO. BLOCK DORAHA, DISTT. LUDHIANA. UNDER HEAD 4215
2022_WSS_87058_1
4304 dt. 17.06.2022 Sihora
Open Tender
Civil Works - Water Works
Item Rate
90 days
Distt Ludhiana
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
₹24,378
23 Aug 2022
22 Jun 2022
1 Jul 2022
22 Jun 2022
1 Jul 2022
22 Jun 2022
Amount
Drilling of 500mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. complete in all respect.
Drilling of 500mm dia bore with Reverse Rotatry Rig Upto 150 m depth BGL.
1. Erection and dismantling of boaring plant including all arrangment for the transportation of the boaring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work. Pits for collection of water and water for drilling tubewell be arranged by the firm/ contractor at site at his own cost and levelled after the completion of work.
2. In payment of bore shall be made upto the bail plug plus margin (7% of main bore drilling or as actual as per field requirement whihever is less) requred for sustaining the main bore.
Supplying, lowering of MS pipe as per IS: 4270-2001 including MS Sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
200mm i/d 6.4 mm thickness ( Weight 33.6 Kg per mtr.)
Supplying, fixing & lowering of stainless steel cage type wire wound screen as per IS: 8110-2000 or latest ISI Marked, duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore.
200 mm Steel Strainer (slot size 0.75) 6.30 mm thick.
Supplying, fixing and lowering of stainless steel sockets as per IS:8110-2000 or latest, ISI Marked duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respect.
200 mm internal diameter
Supplying and fixing of bail plug of M.S pipe complete with inverted U-hook attached to the bottom plug complete in all respect.
200mm i/d 6.40 mm thickness (weight 33.6 kg per mtr.)
Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S bar complete in all respect.
Supplying & fixing of well cap having thread to fix on housing pipe complete in all respect.
Supplying and fixing mild steel clamps of 6" x ½ (150mm x 12mm ) mild steel flat 5 ft (1.52 mtr) long suitable to fit the housing pipe including the cost nuts & bolts of suitable size complete in all respects..
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S pipe duly welded with suitable grade welding electrode complete in all respect.
Supplying at site Wooden Box of Suitable size with Lid & locking arrangement for preserving strata sample colleted from the bore.
Supplying at site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe)
Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 300 cfm at 250 PSI
Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-incharge.
Supplying of tibba sand/local sand over packing of gravel & clay seal upto G.L below pipe assembly and bore including carriage complete in all respect. As per IS 2800:2019.
Supply & fixing sanitary seal having rubber tight on housing pipe complete in all respect as per IS 2800:2019.
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)
Testing of Water sample for heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide, uranium etc.).
Supplying clay to provide impervious layer below pipe assembly and bore above gravel packing including carriage as per IS 2800:2019.
Sterilization of T/W (As per IS 2800:2019)
Construction of Gravel Pit outside the Pump Chamber. (0.90m Dia.) as per standard design & drawings of public health department.
Providing & installing 150 mm dia delivery main(from tubewell to duck foot bend including cost of C.I bends, Tail piece tees etc... inside the pump chamber as per standard design complete in all respects.
Providing, Laying, fixing & jointing of P.V.C Pipes as per ISI- 4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete including excavation & back filling leveling complete in all respect as per specifications. (Earth work mechanically) PVC pipe 160mm o/d rising main (10Kgf/sqcm)
Provision for making connection with existing pipe line complete in all respects.(Lumsum).
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). (150mm i/d) Class PN-1 as per ISI (c) 150 mm old s.v flanged.
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.9 m. x 0.9 m.
Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set of 20.00 BHP KSB make capable of delivering 688 LPM against a head of 68mtr. Complete in all respects.
Prov. & Fixing of Electric Panel Board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps, Kit-Kat etc. complete in all respects.
Prov. & Fixing of Column pipe (100 mm)
Provision for Submersible Cable 6mm2 thick from pump chamber to proposed New Tubewell. (36x2 = 72 mtr.)
Grassing of ground with doob grass including uprooting rank vegetation and weeds by digging the area to a depth of 15cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, mixing fertilizer rough dressing and then fine dressing for planting new grass including disposal of all rubish with all leads and lifts, planting grass roots and row 10cm apart in both directions watering, weeding and maintenance till turf is formed.
Planting ground covers (ordinary) including digging of beds to 15cm depth and mixing FYM, fertilizer and isecticides, planting of sapling at 25cm distance from plant to plant and row to row.
Credit of old pumping machinery including column pipes & submersible cable etc. complete in all respect.
Credit of old C.I. fitting ( Delivery Main).
M/S Rakesh Kumar Govt. Contractor Dhuri
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .