| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.8 LAccepted-AOC C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | 1 | Accepted-AOC Being the lowest bidder. | |
| 2 | 2₹9.5 L+₹1.6 L (20.9%)Rejected-AOC BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | 2 | Rejected-AOC Being other than the lowest bidder. | |
| 3 | 3₹9.5 L+₹1.6 L (21.0%)Rejected-AOC 1017 A SUBHASH NAGAR BEHIND KHALSA SCHOOL BAREILLY UP | BAREILLY | UTTAR PRADESH | 243001 | 3 | Rejected-AOC Being other than the lowest bidder. |
Tender Value
₹14.9 L
EMD Value
₹29,800
Closing Date
23 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bareilly
HQ CWE Bareilly Station Road Bareilly Cantt UP-243001
CA NO. CWE BLY / GE(E)/ 41 OF 2021-2022 REPAIR/MAINT OF SUMMER APPLIANCES, REFRIGERATOR AND AC UNDER GE (EAST) BAREILLY
2021_MES_446889_1
8200/B/681/E8
Open Tender
Civil Works - Others
Item Rate
270 days
Bareilly
Class E Category b(i) For Unenlisted Contractor - Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value of work, Annual turnover, working capital , etc as mentioned in NIT.
6 documents required · 6 mandatory
₹500
GE(E) Bareilly
₹29,800
Yes
30 Sept 2021
23 Jul 2021
30 Aug 2021
23 Jul 2021
23 Aug 2021
10 Aug 2021
60 days
Amount
M&L for overhauling/servicing of Air Conditioning split/window type of any capacity installed at various locations at any floor by removing dust by blower, washing and cleaning of condensing and cooling coil with suitable chemical, checking connection of all components including oiling and greasing complete all as specified and directed
M&L for overhauling/servicing of Water Cooler of any capacity installed at various location at any floor by means of removing dust by blower, washing and cleaning of condensing and cooling coil with suitable chemical, checking connection of all components including oiling and greasing complete all as specified and directed
M&L for overhauling/servicing of Refrigerator/Deep freezers of any capacity installed at various location at any floor by means of removing dust by blower, washing and cleaning of condensing and cooling coil with suitable chemical, checking connection of all components including oiling and greasing complete all as specified and directed
S&F in replacement defective and broken copper suction pipe of 20mm dia including cutting of damaged/worn out pipe with the new copper pipe soldering & brazing, flaring with insulating including all other accessories required at site complete all as specified and directed.
S&F in replacement defective and broken copper dischage line 15mm dia including cutting of damaged/worn out with the new copper pipe, soldering & brazing, flaring with insulation including all other accessories required at site complete all as specified and direct
S&F hermetically sealed unit compressor suitable for working on SP , 50 HZ AC supply after taking out unserviceable compressor from window type AC of any make including making necessary refrigerant pipe, elect connection , leakage testing, for 1.5 TR capacity complete all as specified and as directed.
S&F hermetically sealed unit compressor suitable for working on SP , 50 HZ AC supply after taking out unserviceable compressor from window type AC of any make including making necessary refrigerant pipe, elect connection , leakage testing, for 2 TR capacity complete all as specified and as directed.
S&F hermetically sealed unit compressor suitable for working on SP , 50 HZ AC supply after taking out unserviceable compressor from split type AC of any make including making necessary refrigerant pipe, elect connection , leakage testing for 2 TR capacity complete all as specified and as directed.
S&F hermetically sealed unit compressor suitable for working on SP , 50 HZ AC supply after taking out unserviceable compressor from split type AC of any make including making necessary refrigerant pipe, elect connection , leakage testing for 1.5 TR capacity complete all as specified and as directed.
S&F hermetically sealed unit compressor suitable for working on SP 50 Hz AC supply after taking out carefully from water cooler capacity 40/80 Ltrs of any type and make, including making necessary refrigerant pipe, elect connections including making free from any leakage complete all as specified and directed.
S&F hermetically sealed unit compressor suitable for working on SP 50 Hz AC supply after taking out carefully from water cooler capacity 60/120 Ltrs of any type and make, including making necessary refrigerant pipe, elect connections including making free from any leakages complete all as specified and as directed.
S&F hermetically sealed unit compressor suitable for working on SP 50 Hz AC supply after taking out carefully from water cooler capacity 150 Ltrs of any type and make, including making necessary refrigerant pipe, elect connections including making free from any leakages complete all as specified and as directed.
S&F hermetically sealed unit compressor suitable for working on SP 50 Hz AC supply after taking out carefully from refrigerator capacity 165 to 210 Ltrs of any type and make, including making necessary refrigerant pipe, elect connections including makingfree from any leakages complete all as specified and as directed.
S&F hermetically sealed unit compressor suitable for working on SP 50 Hz AC supply after taking out carefully from refrigerator capacity 265 to 310 Ltrs of any type and make, including making necessary refrigerant pipe, elect connections including making free from any leakages complete all as specified and as directed.
M&L for replacement of old unserviceable starting relay of window/Split type AC 1 to 2 TR capacity of any make including making necessary electric connections complete all as specified and as directed.
M&L for replacement of old unserviceable starting relay of water coolers 80 to 150 Ltr capacity of any make including making necessary electric connections complete all as specified and as directed.
S&F in repair overload protector for water coolers 80 Ltr capacity complete all as specified and as directed.
S&F in repair overload protector for AC 1.5 TR/WC 120 Ltr capacity complete all as specified and as directed.
S&F in repair overload protector for AC 2 TR/WC 150 Ltr capacity complete all as specified and as directed.
M&L for opening body of water cooler, taking out cooling tank to rectify leakage of refrigerant tube/condenser and refixing the same after carrying necessary repairs, including leakage test, filling insulation material and clamping with GI strip complete all as specified and directed.
M&L for taking out burnt fan motor 1/6 or 1/7 HP from window type AC of any size / capacity and supply & fix new fan motor including, providing insulation material including making necessary electric connections complete all as specified and directed.
S&F in replacement fan blade of aluminium for window/split type AC (1,1.5,2 TR capacity) complete all as specified and directed.
S&F in replacement air cooled finned condenser suitable for water cooler of any size and make complete all as specified and directed.
M&L for charging of refrigerant suitable & ecofriendly refrigerators gas for window /split type AC/Water cooler of any make (1.5 & 2 TR capacity) by carefully duly taking necessary precautions, making necessary copper tubing connections for refrigerant lines and making leak proof including testing for leakage, and optimum grill temperature complete all as specified by the manufacturer and directed.
M&L for charging of refrigerant refrigerant suitable & ecofriendly refrigerators gas in refrigerant for refrigerator 165 to 310 ltrs by carefully duly taking necessary precautions, making necessary copper tubing connections for refrigerant lines and making leak proof including testing for leakage, and optimum grill temperature complete all as specified by the manufacturer and directed.
M&L for scrapping out old bubbled paint, cleaning the surface, leveling and spray painting with one coat of synthetic enamel paint over one coat of primer as per existing colour to desert cooler any make and type at site including writing MES/SM/SL No with black enamel paint complete all as specified and directed. Note:- painting shall be carried out at site by bringing compressor machine and rate quoted shall be deemed to be include for the same.
M&L for scrapping out old bubbled paint, cleaning the surface, leveling and spray painting with one coat of synthetic enamel paint over one coat of primer as per existing colour to water cooler any make and type at site including writing MES/SM/SL No with black enamel paint complete all as specified and directed. Note:- painting shall be carried out at site by bringing compressor machine and rate quoted deemed to be include for the same complete all as specified and directed.
S&F in replacement running capacitor 45/50mfd 440/220V complete all as specified and directed
S&F in replacement running capacitor 80/120mfd 440/220V complete all as specified and directed
S&F in replacement PVC flexible drain pipe 1" dia 1.5 mtr long for drainage of water coolers of any make and type complete all as specified and directed.
S&F in replacement fan motor, AC, 230 V, high speed suitable for split AC 1.5/2 ton for any Make of AC complete all as specified and directed.
S&F in replacement new remote assembly for split/window type AC, 1.5/2 ton of any make & model complete all as specified and directed.
S&F in replacement unserviceable defective PCB plate in 1.5/2 ton AC of any make and supply fixing new remote control kit/ PCB plate in position with all electric connections complete all as specified and directed.
Disconnecting and taking out existing defective MCB of any type & capacity & in any position and supplying and fixing new MCB, single pole, 240 volt, 6 to 32 Amps complete all as specified and directed.
Disconnecting & taking out existing defective industrial type Plug top of any description & in any Position and supplying and fixing new Plug Top metallic industrial type, 2Pole+earths, 20 Amps, 240 volts complete all as specified and directed.
Disconnecting & taking out existing defective Industrial type socket of any description & in any Position and supplying and fixing new Industrial Type Socket 2 Pole+earths, 20 Amps, 240 volts complete all as specified and directed.
Disconnecting and taking out existing defective/ unserviceable industrial type socket with top in sheet metal box, of any description & in any position and Supplying and fixing new industrial type socket, 2 pole + earth 32 Amps, with and including plug top and MCB, 20 Amps, in sheet metal enclosure complete all as specified and directed.
Disconnecting and taking out existing defective / unserviceable timer of any description & in any position and supplying & fixing new timer assembly suitable for split type AC of any capacity complete all as specified and directed.
Dismantling and taking out exiting defective service valve of any type & in any position and supplying and fixing new brass service valve complete all as specified and directed.
Disconnecting and taking out existing defective / unserviceable nipple and Supply and fix brass Nipple 15 mm dia for inlet and out let connection of water coolers any type / size including one PVC connection 15 mm dia with brass coupling on both ends complete all as specified and directed.
S&F in repair fan blade matching with the existing of any type and any description suitable for motor of any capacity for water cooler complete all as specified and directed.
S&F in replacement condenser coil suitable for 330 ltr capacity refrigerator of any description and any model complete all as specified and directed.
Taking out & removing old existing plywood of any description and in any position and supplying and fixing new plywood 4mm thick, grade BWR, type BB, 3 ply, cut to size made to shape and fixed in position with nails as to make the window of desert cooler/window AC etc air tight complete all as specified and directed.
M&L for cross arms, bracing supports clamps and back plate fabricated from structural steel section including bolts, nuts, washers and welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M&L for shifting of existing Air Conditioning window type AC of 1.5/2 ton capacity from one place to another place any height/any floor as per requirement of users, any make and re-installation and commissioning the unit including cutting of window/wall as required at site complete including making good the distrubed surfaces matching with original condition and testing after gas charging complete all as specified and directed.
M&L for shifting of existing Air Conditioning Split AC type of 1.5/2 ton capacity from one place to another place at any height/any floor as per requirement of users, any make and re-installation and commissioning the unit including cutting of window/wall as required at site complete including making good the distrubed surfaces matching with original condition and testing after gas charging complete all as specified and directed.
M&L for Servicing, checking of electric wiring, PCB Circuits, relays, contactor etc and replacement of defective wiring of Automatic Voltage Stablizer of 2/3/4/5KVA capacity of any make and carryout minor repair of PCB by changing resistance, condensor, transistor, indicator lamp, 2 way switch, PVC insulating sleeves etc and making functional including testing complete all as specified and directed at site. Note :- Relays, transformer, ammeter, voltmeter , Kit kat fuse shall be measured and paid separately under relevant items as "Supply Only"
Supply only relay 24Volts, 20 Amps suitable for Automatic Voltage stablizer complete all as specified and directed.
Supply only kit kat fuse of 32Amps with carrier complete all as specified and directed.
Supply only Analog, voltmeter 0-500V of of any shape and size to match existing complete all as specified and directed.
Supply only auxilary transformer of 12/24Volts capacity suitable for PCB circuits of Stablizer complete all as specified and directed at site.
Supply only PCB for 2/5KVA stablizer complete all as specified and directed.
S&F desert cooler body made out of 20 gauge sheet suitable for evaporating type desert cooler of standard size (73x73x93) cm including side panel-3 Nos with 20 gauge PGI sheet and water tank height 20cm, grill with fins, electrical wiring and connection with SP switch piano type with distribution PVC cup and elbow, PVC pipe connection, PVC Cable 3 core 23/.0076-3 and outer side painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed.
S&F running capacitor 4mfd 440/220V complete all as specified and directed.
S&F in replacement vertical pump/ submersible pump for 2.80 mtr head complete all as specified and directed.
S&F in replacement side panel shutters made of PGI sheet 24 SWG suitable for any type & capacity of desert cooler as per existing complete all as specified and directed.
S&F in replacement wood wool thick pad of any size (set of three) suitable for desert cooler panel including GI chicken wire mesh of size 25 mm x 25 mm apperture complete all as specified and directed.
S&F in replacement 1400 rpm fan motor kit of 500 mm sweep 180 watt, single phase, AC 220/240 volts and making necessary connections complete all as specified and directed.
S&F in replacement plug top, 5 Amps to desert coolers complete all as specified and directed.
S&F in replacement Plastic distribution (three way) of superior quality for desert cooler complete all as specified and directed.
S&F fan blade made of iron suitable & matching with the existing desert cooler complete all as specified and directed.
S&F of PVC fan blade suitable & matching with the existing desert cooler complete all as specified and directed.
S&F in replacement of desert cooler tank made out of PGI sheet 20 gauge including fixing complete all as specified and directed.
S&F in repair float valve plastic ball for 15 mm dia bore suitable for desert cooler complete all as specified and directed.
S&F in repair brass stop cock suitable for 15 mm dia complete all as specified and directed.
S&F in replacement push cock 15mm bore chromium plated, heavy duty suitable for water cooler of any make/size complete all as specified and directed
S&F in repair PVC connection 15mm dia with CP nut, 450 mm long all as specified and directed.
M&L for Point wiring in repair of water cooler/refrigerator with 2.5 Sqmm copper conductor cable (multistranded) FRLS, PVC insulated and unsheathed cable in and including concealed PVC conduit (after cutting chases in the existing wall surface) 25mm dia with sunk cast iron/pressed steel terminal box of adequate size with 3mm thick plastic laminated sheet cover for one light point or one fan point controlled by one, one way switch including continuous 2.5 Sqmm copper conductor (multistranded) FRLS PVC insulated and unsheathed cable connected to earth dully complete all as specified complete all as specified and directed.
All as per item No. 69 here in before but for Water cooler /deep freezer point using 4 Sqmm copper conductor cable (multi-stranded FRLS PVC insulated and unsheathed cable and 2.5 sqmm copper (multistranded) FRLS PVC insulated and unsheathed earth wire complete all as specified and directed.
S&F in replacement switch socket combination 2 in 1, 3 pin, 5/15A, flush type universal, complete all as specified and directed.
S&F in replacement sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 Sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 Sqmm as earth continuity conductor drawn through & including PVC conduit complete all as specified and directed. Note: 2 runs of wire alongwith one run of eartwire with conduit shall be measured as one unit.
S&F hermetically sealed unit compressor suitable for working on SP , 50 HZ supply after taking out unserviceable compressor from deep freezer 300/310/400 Ltr capacity of any make including making necessary refrigerant pipe, elect connection, leakage testing complete all as specified and directed.
S&F hermetically sealed unit compressor suitable for working on SP , 50 HZ supply after taking out unserviceable compressor from deep freezer 200 Ltr capacity of any make including making necessary refrigerant pipe, elect connection, leakage testing complete all as specified and directed. Note: 2 runs of wire alongwith one run of earthwire with conduit shall be measured as one unit.
S&F in repacement relay assembly suitable for 200 Ltrs deep freezer complete all as specified and directed.
S&F in repair relay assembly suitable for 300/ 310/400 Ltrs deep freezer complete all as specified and directed.
S&F in repair over load protector (OLP) for 200 Ltrs deep freezer complete all as specified and directed.
S&F in repair over load protector (OLP) for 300/310/400 Ltrs deep freezer complete all as specified and directed.
Supply & charging of ecofriendly refrigerant gas in deep freezer of capacity 200 Ltr capacity and of description to its saturation level complete all as specified and directed.
S&F in repair thermostat switch with knob suitable for 200 Ltr capacity of deep freezer complete all as specified and directed.
S&F in repair thermostat switch with knob suitable for 300/310/400 Ltrs capacity of deep freezer complete all as specified and directed.
M&L in repair Freezer assembly suitable for 300/ 310 ltr deep freezer complete all as specified and directed.
M&L in repair Freezer assembly with freezer door suitable for 200 Ltrs refrigerator complete all as specified and directed.
S&F in replacement Inner panel assembly suitable for 310 Ltrs capacity of deep freezer complete all as specified and directed.
S&F in replacement Inner panel assembly suitable for 200 Ltrs capacity of deep freezer complete all as specified and directed.
Dismantling and providing new Megnetic door gasket suitable for 200 Ltrs of deep freezer complete all as specified and directed.
Dismantling and providing Megnetic door gasket suitable for 300/310/400 Ltrs deep freezer complete all as specified and directed.
M&L for scraping out old paint and preparation of surfaces of deep freezer of any capacity and apply two coats of spray painting of synthetic enamel paint of existing colour over a coat of red oxide primer on external surface and two coats of black synthetic enamel paint on compressor complete all as specified and directed
S&F in replacement blower motor suitable for 300/310/400 ltrs capacity deep freezer complete including taking out existing one complete all as specified and directed.
S&F in replacement blower motor suitable for 200 ltrs capacity deep freezer complete including taking out existing one complete all as specified and directed.
S&F in replacement, Filter, two way (as per sample) for deep freezer complete all as specified and directed.
S&F flexible copper conductor cable of size 3 core (4/0.0076) 1100 Volts grade complete all as specified and directed.
S&F in replacement wiring kit suitable for window/split type AC, 1.5 ton capacity including soldering tapping and thimbling etc complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 64,830.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
prabhave traders
K.S.Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .