GEMC-511687758563059
Awarded to ARVIND LIMITED
₹3.5 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Neos-IP-024 | Neos & Neos IP-024 | - | 1 NOS | ₹3.5 L | 355,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.5 LQualified Make: Neos
Model: Neos & Neos IP-024 AHMEDABAD GUJARAT 380025 | 380025 | Make: Neos
Model: Neos & Neos IP-024 | ₹3.5 L | L1 | Qualified |
| 2 | L3₹3.9 L+₹32,866 (9.26%)Qualified Make: CORAL
Model: CORAL DX 2000 CHANDIGARH CHANDIGARH 160047 | CHANDIGARH | CHANDIGARH | 160047 | Make: CORAL
Model: CORAL DX 2000 | ₹3.9 L+₹32,866 (9.26%) | L3 | Qualified |
| 3 | L4₹4 L+₹45,000 (12.7%)Qualified Make: Matrix
Model: MATRIX ETERNITY GENX12SDC 15 19 GIDC WAGHODIA N | Make: Matrix
Model: MATRIX ETERNITY GENX12SDC | ₹4 L+₹45,000 (12.7%) | L4 | Qualified |
| 4 | Qualified Make: Neos
Model: Neos & Neos IP-024 SCO 368 2ND FLOOR SECTOR 44 D CHANDIGARH CHANDIGARH CHANDIGARH 160047 UDYAM CH 01 0025787 | CHANDIGARH | CHANDIGARH | 160047 | Make: Neos
Model: Neos & Neos IP-024 | - | - | Qualified |
| 5 | Disqualified Make: Avaya
Model: Avaya IP Office 500V2 245B SECOND FLOOR SANT NAGAR ISKCON ROAD EAST OF KAILASH SOUTH DELHI DELHI 110065 | SOUTH EAST DELHI | DELHI | 110065 | Make: Avaya
Model: Avaya IP Office 500V2 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
22 Oct 2018, 7:00 pmClosed
pabx system-EPABX Pabx System-EPABX ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values EXTENSION AND TRUNK/JUNCTION EPABX system Implementation Tech nology/Architecture Hybrid ( Microprocessor based also supporting SIP extension ) Conventional ( Card/microcontroller based )
Hybrid ( Microprocessor based also supporting SIP extension )
Server Based ( Switching through Call Server Application ) Number of Analogue Extensions/FXS Ports 64 * (or higher) Expandable Upto (TDM/FSX Ports) 128 * Number of Digital Extensions 8 8 Number of Analogue Junction/FXO ports 8 * Number of SIP Extensions NA * SIP Extensions NA * 1/11 expandable upto Number of SIP Trunks NA 4
8
16
32
64
96
128
256
NA MAIN DISTRIBUTION FRAME(MDF) MDF(Number of pair) 100 * Integrated Protection Module(IPM) true true
false If YES
number of Integrated Protection Module(IPMs) 100 * CARDS CARDS Type of Cards Supported BRI
PRI
E1
E&M
Radio Interface
GSM BRI
GSM
NA Number of Ports per Card Supported 16 1
2
4
6
12
24
NA GATEWAYS Type of Gateways Supported Universal Gateway
SIP
FXO
FXS
Radio
E&M * Number of Ports per Gateway Supported 16 * CONSOLE Type of Operator Console NA PC based
Key phone based
Server Based
NA Number of Operator Console NA * SERVER SPECIFICATIONS REQUIREMENTS Total Number of Servers Included in the Supply NA * "Number of Hot Standby Servers out of Total Servers
included in the Scope of Supply" 0 * Server Form Factor Tower * Rack Size (RU)/Space Required for each Server 4 * Processor Make NA * Processor Configuration & Description NA * Total Number of processor NA 1
10
NA Number of Redundant Processors Included in the Total Number of Processor NA 1
NA 2/11 Number of Cores per Processor NA * Type of RAM NA * RAM Size (in GB) NA 4
NA T ype of Hard Disk Drive NA * Capacity of Hard Disk Drive (in TB) NA * Hot Swap Components NA Power Supply Unit
Fans
HDD
NA Network Interface NA * SOFTWARES Applcation Software Type/Capabilities NA Call Server Software
Hot StandBy Server Software
Unified Communication Server Software
Network Management Server Software
NA Type of Licence NA Perpetual
Subscription Based
NA Name of Softwares - * Name of the OEM - * OEM Model/Part Number - * Software Description - * Software Version - * Date of Launch of Version - * Free supports/updates during validity of license NA * SOFTWARE FEATURES Analog Extention/FXS ( If Yes
Number of Software/Licences shall be Commensurate Equal to the Number of Analog Extension/FXS Offered under ""EXTENSION AND TRUNK/JUNCTION"" ) YES YES
NO
NA ( For Convensional PBX ) "Digital Extension ( If Yes
Number of Software/Licences YES YES
NA ( For Convensional PBX ) 3/11 shall be Commensurate Equal to the Number of Digital Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" "Analog Junction/FXO ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of Analog Junction/FXO Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
NA ( For Convensional PBX ) "SIP extension ( If Yes
Number of Software/Licences shall be Commensurate Equal to the Number of SIP Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NO YES
NA ( For Convensional PBX ) "SIP trunk ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NO YES
NA ( For Convensional PBX ) "PRI Trunk ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of PRI Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
NA ( For Convensional PBX ) "Radio Interface ( If Yes
Number of Software/Licences shall be Commensurate Equal to the Number of Radio Interface NO YES
NA ( For Convensional PBX ) 4/11 Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" "GSM ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of GSM Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO YES
NA ( For Convensional PBX ) "E1 Trunk ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of E1 Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
NA ( For Convensional PBX ) "E&M ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of E&M Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO YES
NO GENERAL FEATURES of EPABX SYSTEM Number of Conference Participants Supported 64 8
NA Number of Direct Station Selection Keys per Console NA * Number of Media Channel/Ports Supported 128 8
512
NA Number of IP-TDM Concurrent Calls(2 users per call) Supported 16 * Call Buffer Memory System true true
false If Call Buffer Memory Available
Number of Records 2000 100
250
500
1000
2000
NA Hot Standby false true
false 5/11 Redundant CPU If YES
Number of Hot Standby CPU Cards NA 1
NA Hot Standby Redundant PSU (Power Supply Unit) false true
Number of Hot Standby Redundant PSU Cards NA 1
NA Inbuilt Voice Mail for EPABX System true true
false If Voice Mail Available
Number of Voice Mail Channels 4 4
NA Available for Voice Mail
Number of Hours of Recording 4 4
NA Auto Attendant Facility true * If Available
Number of Auto Attendant Channels 4 * ASMDR/CDR true true
false Voice Logger NA Inbuilt
Inbuilt External Connecting facility
NA If YES
Number of Simultaneous Calls that can be Recorded in Voice Logger NA * Security Feature(for server based) NA * Supported Functionalities (for server based) NA * Supported Codecs NA * Any other features Along With System
the following items added 1) Battery Set 12V
100 AH - 4no's; 2) PBT Beetel M78 - 2no's; 3) Cordless analog phone - 8no's; 4) PBT Beetel C51 - 20 no's; 5) Supply and Laying of 2 Pair PVC cable with casing caping - 650mtr; 6) Supply and laying of 20 Pair Jelly filled armoured cable - * 6/11 50mtr; 7) Supply of 20pair MDF with IPM 8) Digital Key Phone 8Nos. SYSTEM/EXTENSION/AT TENDANT CONSOLE FEATURES System Features Automatic Route Selection facility
DID facility(Direct inward dialing)
DOD facility(Direct outward dialing)
DISA facility(Direct inward station access)
DOSA facility(Direct outwards station access)
Multi Level Voice DISA facility
Privacy of Call
Facility for connecting recorded voice answering
ASMD R/CDR
Programmable class of service for (STD/ISD/LOCAL) dialing as per need
Caller ID information for both internal and external callers (over Analogue
ISDN PRI)
unique authorization codes for every users
Automatic call back
Call waiting
Music-on-hold facility
Call budgeting
Least cost routing
Mix-mode dialing
Provision for remote logins
Interactive Voice Response System(IVRS)
Extensio n to Extension dialing * Extension Features Call forwarding
Consultatio n Hold
Brokers Call
Automatic call transfer
Conference call
Call pick up
Call re routing
Auto call disconnection
Dynamic STD Lock
Paging on key phone
Background music
Password control
Virtual Telephony
Howler Tone
Call parking
Auto answer/Auto off
Emergency call facili * 7/11 ty
Missed/Dialed/Receiv ed Call Lists
Last Caller Call back
Password display suppression
Personal Identification Number
Hotline
Preset Conference Calls
Direct Call billing in rupees
Call billing printout
Calling line ide ntification(CLI)
Remote Maintenance
Other Extension features Attendant Console Features Answering an incoming call
Call queuing
Serial Call
Call waiting display
Automatic Call Distribution
Call Hold
Trunk offering
Night service
Head phone connectivity
Other Attendants console Features Answering an incoming call
Other Attendants console Features Voice Prompts and Announcement true * If yes
Number of Levels of IVRS 2 1
3
5
7
NA POWER SOURCE Supply Voltage 48V DC 230V AC
50HZ
48V DC
NA Provision for Inbuilt Battery Charging Arrangement for providing Battery Backup YES * FCBC YES YES
minimum current Rating of FCBC at chrging voltage of 48V (Ampere) 25A 10A
12.5A
25A
50A
NA Protection against over current and accidental reversal of polarity on the input side and against over current
over voltage on the output side YES * OPERATING CONDITIONS Minimum Operating Temperature (Degree C) 0 10
0
10 8/11 Maximum Operating Temperature (Degree C) 45 35
40
45
50
55 Operating Humidity (RH) (% ) 95 80
85
90
95 TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications YES * TEC approval Certificate number - * Availability of the test report from Central Government/NABL ILAC acredited lab to prove conformity to the specification including Environmental Test Sequence true * Test Report Number and date (not a part of biddable parameter) - * Name and Address of the Test lab(not a part of biddable parameter) - * Test reports consist of verification of all the features & functional parameters & environmental tests true * conformity to Dry Heat for 16 hours at maximum specified temperature degree C in accordance with IS:9000/part-3/sectio n-5/1977 latest true true
false conformity to Cold Test for 4 hours at minimum specified temperature degree C in accordance with IS:9000/part-2/sectio n-4/1977 latest true true
false conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:9000/part-5/s ection-1/1991 latest true true
false 9/11 INSTALLATION AND MAINTENANCE Installation and Commissioning With With
Without Chemical Earthing to achieve resistance false true
false Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System - * OPERATION & MAINTENANCE SUPPORT The scope of supply include one set of operation and maintenance manual for each equipment YES * Operation & Maintenance terminal Provided * Training provided to buyers true true
Details of training On site training for 3 days On site training for 3 days
On site training for 5 days
NA Packing List - * SERVICES Warranty 1 1
9
10 (or higher) Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System
* Compliance to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vivek Kumar Gupta 380019
Office Of Chief Project Director
Quarter No. 733
Railway Colony
Opposite Post Office Sabarmati Ahmedabad 1 15
736373
GEM/2018/B/103769
GeM Contract
pabx system-EPABX
GeM Contract
15 days
Gujarat; Ahmadabad
PRODUCT
Awarded to ARVIND LIMITED
₹3.5 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Neos-IP-024 | Neos & Neos IP-024 | - | 1 NOS | ₹3.5 L | 355,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| pabx system-EPABX Pabx System-EPABX ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values EXTENSION AND TRUNK/JUNCTION EPABX system Implementation Tech nology/Architecture Hybrid ( Microprocessor based also supporting SIP extension ) Conventional ( Card/microcontroller based ) | - | - | - |
| Hybrid ( Microprocessor based also supporting SIP extension ) | - | - | - |
| Server Based ( Switching through Call Server Application ) Number of Analogue Extensions/FXS Ports 64 * (or higher) Expandable Upto (TDM/FSX Ports) 128 * Number of Digital Extensions 8 8 Number of Analogue Junction/FXO ports 8 * Number of SIP Extensions NA * SIP Extensions NA * 1/11 expandable upto Number of SIP Trunks NA 4 | - | - | - |
| 8 | - | - | - |
| 16 | - | - | - |
| 32 | - | - | - |
| 64 | - | - | - |
| 96 | - | - | - |
| 128 | - | - | - |
| 256 | - | - | - |
| NA MAIN DISTRIBUTION FRAME(MDF) MDF(Number of pair) 100 * Integrated Protection Module(IPM) true true | - | - | - |
| false If YES | - | - | - |
| number of Integrated Protection Module(IPMs) 100 * CARDS CARDS Type of Cards Supported BRI | - | - | - |
| PRI | - | - | - |
| E1 | - | - | - |
| E&M | - | - | - |
| Radio Interface | - | - | - |
| GSM BRI | - | - | - |
| GSM | - | - | - |
| NA Number of Ports per Card Supported 16 1 | - | - | - |
| 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 12 | - | - | - |
| 24 | - | - | - |
| NA GATEWAYS Type of Gateways Supported Universal Gateway | - | - | - |
| SIP | - | - | - |
| FXO | - | - | - |
| FXS | - | - | - |
| Radio | - | - | - |
| E&M * Number of Ports per Gateway Supported 16 * CONSOLE Type of Operator Console NA PC based | - | - | - |
| Key phone based | - | - | - |
| Server Based | - | - | - |
| NA Number of Operator Console NA * SERVER SPECIFICATIONS REQUIREMENTS Total Number of Servers Included in the Supply NA * "Number of Hot Standby Servers out of Total Servers | - | - | - |
| included in the Scope of Supply" 0 * Server Form Factor Tower * Rack Size (RU)/Space Required for each Server 4 * Processor Make NA * Processor Configuration & Description NA * Total Number of processor NA 1 | - | - | - |
| 10 | - | - | - |
| NA Number of Redundant Processors Included in the Total Number of Processor NA 1 | - | - | - |
| NA 2/11 Number of Cores per Processor NA * Type of RAM NA * RAM Size (in GB) NA 4 | - | - | - |
| NA T ype of Hard Disk Drive NA * Capacity of Hard Disk Drive (in TB) NA * Hot Swap Components NA Power Supply Unit | - | - | - |
| Fans | - | - | - |
| HDD | - | - | - |
| NA Network Interface NA * SOFTWARES Applcation Software Type/Capabilities NA Call Server Software | - | - | - |
| Hot StandBy Server Software | - | - | - |
| Unified Communication Server Software | - | - | - |
| Network Management Server Software | - | - | - |
| NA Type of Licence NA Perpetual | - | - | - |
| Subscription Based | - | - | - |
| NA Name of Softwares - * Name of the OEM - * OEM Model/Part Number - * Software Description - * Software Version - * Date of Launch of Version - * Free supports/updates during validity of license NA * SOFTWARE FEATURES Analog Extention/FXS ( If Yes | - | - | - |
| Number of Software/Licences shall be Commensurate Equal to the Number of Analog Extension/FXS Offered under ""EXTENSION AND TRUNK/JUNCTION"" ) YES YES | - | - | - |
| NO | - | - | - |
| NA ( For Convensional PBX ) "Digital Extension ( If Yes | - | - | - |
| Number of Software/Licences YES YES | - | - | - |
| NA ( For Convensional PBX ) 3/11 shall be Commensurate Equal to the Number of Digital Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" "Analog Junction/FXO ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of Analog Junction/FXO Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES | - | - | - |
| NA ( For Convensional PBX ) "SIP extension ( If Yes | - | - | - |
| Number of Software/Licences shall be Commensurate Equal to the Number of SIP Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NO YES | - | - | - |
| NA ( For Convensional PBX ) "SIP trunk ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NO YES | - | - | - |
| NA ( For Convensional PBX ) "PRI Trunk ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of PRI Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES | - | - | - |
| NA ( For Convensional PBX ) "Radio Interface ( If Yes | - | - | - |
| Number of Software/Licences shall be Commensurate Equal to the Number of Radio Interface NO YES | - | - | - |
| NA ( For Convensional PBX ) 4/11 Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" "GSM ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of GSM Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO YES | - | - | - |
| NA ( For Convensional PBX ) "E1 Trunk ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of E1 Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES | - | - | - |
| NA ( For Convensional PBX ) "E&M ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of E&M Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO YES | - | - | - |
| NO GENERAL FEATURES of EPABX SYSTEM Number of Conference Participants Supported 64 8 | - | - | - |
| NA Number of Direct Station Selection Keys per Console NA * Number of Media Channel/Ports Supported 128 8 | - | - | - |
| 512 | - | - | - |
| NA Number of IP-TDM Concurrent Calls(2 users per call) Supported 16 * Call Buffer Memory System true true | - | - | - |
| false If Call Buffer Memory Available | - | - | - |
| Number of Records 2000 100 | - | - | - |
| 250 | - | - | - |
| 500 | - | - | - |
| 1000 | - | - | - |
| 2000 | - | - | - |
| NA Hot Standby false true | - | - | - |
| false 5/11 Redundant CPU If YES | - | - | - |
| Number of Hot Standby CPU Cards NA 1 | - | - | - |
| NA Hot Standby Redundant PSU (Power Supply Unit) false true | - | - | - |
| Number of Hot Standby Redundant PSU Cards NA 1 | - | - | - |
| NA Inbuilt Voice Mail for EPABX System true true | - | - | - |
| false If Voice Mail Available | - | - | - |
| Number of Voice Mail Channels 4 4 | - | - | - |
| NA Available for Voice Mail | - | - | - |
| Number of Hours of Recording 4 4 | - | - | - |
| NA Auto Attendant Facility true * If Available | - | - | - |
| Number of Auto Attendant Channels 4 * ASMDR/CDR true true | - | - | - |
| false Voice Logger NA Inbuilt | - | - | - |
| Inbuilt External Connecting facility | - | - | - |
| NA If YES | - | - | - |
| Number of Simultaneous Calls that can be Recorded in Voice Logger NA * Security Feature(for server based) NA * Supported Functionalities (for server based) NA * Supported Codecs NA * Any other features Along With System | - | - | - |
| the following items added 1) Battery Set 12V | - | - | - |
| 100 AH - 4no's; 2) PBT Beetel M78 - 2no's; 3) Cordless analog phone - 8no's; 4) PBT Beetel C51 - 20 no's; 5) Supply and Laying of 2 Pair PVC cable with casing caping - 650mtr; 6) Supply and laying of 20 Pair Jelly filled armoured cable - * 6/11 50mtr; 7) Supply of 20pair MDF with IPM 8) Digital Key Phone 8Nos. SYSTEM/EXTENSION/AT TENDANT CONSOLE FEATURES System Features Automatic Route Selection facility | - | - | - |
| DID facility(Direct inward dialing) | - | - | - |
| DOD facility(Direct outward dialing) | - | - | - |
| DISA facility(Direct inward station access) | - | - | - |
| DOSA facility(Direct outwards station access) | - | - | - |
| Multi Level Voice DISA facility | - | - | - |
| Privacy of Call | - | - | - |
| Facility for connecting recorded voice answering | - | - | - |
| ASMD R/CDR | - | - | - |
| Programmable class of service for (STD/ISD/LOCAL) dialing as per need | - | - | - |
| Caller ID information for both internal and external callers (over Analogue | - | - | - |
| ISDN PRI) | - | - | - |
| unique authorization codes for every users | - | - | - |
| Automatic call back | - | - | - |
| Call waiting | - | - | - |
| Music-on-hold facility | - | - | - |
| Call budgeting | - | - | - |
| Least cost routing | - | - | - |
| Mix-mode dialing | - | - | - |
| Provision for remote logins | - | - | - |
| Interactive Voice Response System(IVRS) | - | - | - |
| Extensio n to Extension dialing * Extension Features Call forwarding | - | - | - |
| Consultatio n Hold | - | - | - |
| Brokers Call | - | - | - |
| Automatic call transfer | - | - | - |
| Conference call | - | - | - |
| Call pick up | - | - | - |
| Call re routing | - | - | - |
| Auto call disconnection | - | - | - |
| Dynamic STD Lock | - | - | - |
| Paging on key phone | - | - | - |
| Background music | - | - | - |
| Password control | - | - | - |
| Virtual Telephony | - | - | - |
| Howler Tone | - | - | - |
| Call parking | - | - | - |
| Auto answer/Auto off | - | - | - |
| Emergency call facili * 7/11 ty | - | - | - |
| Missed/Dialed/Receiv ed Call Lists | - | - | - |
| Last Caller Call back | - | - | - |
| Password display suppression | - | - | - |
| Personal Identification Number | - | - | - |
| Hotline | - | - | - |
| Preset Conference Calls | - | - | - |
| Direct Call billing in rupees | - | - | - |
| Call billing printout | - | - | - |
| Calling line ide ntification(CLI) | - | - | - |
| Remote Maintenance | - | - | - |
| Other Extension features Attendant Console Features Answering an incoming call | - | - | - |
| Call queuing | - | - | - |
| Serial Call | - | - | - |
| Call waiting display | - | - | - |
| Automatic Call Distribution | - | - | - |
| Call Hold | - | - | - |
| Trunk offering | - | - | - |
| Night service | - | - | - |
| Head phone connectivity | - | - | - |
| Other Attendants console Features Answering an incoming call | - | - | - |
| Other Attendants console Features Voice Prompts and Announcement true * If yes | - | - | - |
| Number of Levels of IVRS 2 1 | - | - | - |
| 3 | - | - | - |
| 5 | - | - | - |
| 7 | - | - | - |
| NA POWER SOURCE Supply Voltage 48V DC 230V AC | - | - | - |
| 50HZ | - | - | - |
| 48V DC | - | - | - |
| NA Provision for Inbuilt Battery Charging Arrangement for providing Battery Backup YES * FCBC YES YES | - | - | - |
| minimum current Rating of FCBC at chrging voltage of 48V (Ampere) 25A 10A | - | - | - |
| 12.5A | - | - | - |
| 25A | - | - | - |
| 50A | - | - | - |
| NA Protection against over current and accidental reversal of polarity on the input side and against over current | - | - | - |
| over voltage on the output side YES * OPERATING CONDITIONS Minimum Operating Temperature (Degree C) 0 10 | - | - | - |
| 0 | - | - | - |
| 10 8/11 Maximum Operating Temperature (Degree C) 45 35 | - | - | - |
| 40 | - | - | - |
| 45 | - | - | - |
| 50 | - | - | - |
| 55 Operating Humidity (RH) (% ) 95 80 | - | - | - |
| 85 | - | - | - |
| 90 | - | - | - |
| 95 TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications YES * TEC approval Certificate number - * Availability of the test report from Central Government/NABL ILAC acredited lab to prove conformity to the specification including Environmental Test Sequence true * Test Report Number and date (not a part of biddable parameter) - * Name and Address of the Test lab(not a part of biddable parameter) - * Test reports consist of verification of all the features & functional parameters & environmental tests true * conformity to Dry Heat for 16 hours at maximum specified temperature degree C in accordance with IS:9000/part-3/sectio n-5/1977 latest true true | - | - | - |
| false conformity to Cold Test for 4 hours at minimum specified temperature degree C in accordance with IS:9000/part-2/sectio n-4/1977 latest true true | - | - | - |
| false conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:9000/part-5/s ection-1/1991 latest true true | - | - | - |
| false 9/11 INSTALLATION AND MAINTENANCE Installation and Commissioning With With | - | - | - |
| Without Chemical Earthing to achieve resistance false true | - | - | - |
| false Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System - * OPERATION & MAINTENANCE SUPPORT The scope of supply include one set of operation and maintenance manual for each equipment YES * Operation & Maintenance terminal Provided * Training provided to buyers true true | - | - | - |
| Details of training On site training for 3 days On site training for 3 days | - | - | - |
| On site training for 5 days | - | - | - |
| NA Packing List - * SERVICES Warranty 1 1 | - | - | - |
| 9 | - | - | - |
| 10 (or higher) Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System | - | - | - |
| * Compliance to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vivek Kumar Gupta 380019 | - | - | - |
| Office Of Chief Project Director | - | - | - |
| Quarter No. 733 | - | - | - |
| Railway Colony | - | - | - |
| Opposite Post Office Sabarmati Ahmedabad 1 15 | - | - | - |
Exempted
24 Oct 2018
12 Oct 2018
contract_GEMC-511687758563059.pdf
GEM_CONTRACT • 0.05 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_736373.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .