Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC KOLLAM KERALA | PATHANAMTHITTA | KERALA | 689694 | ₹7.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹9.9 LRejected-AOC AROOR P O ALAPPUZHA KERALA 688534 | ALAPPUZHA | ALAPPUZHA | KERALA | 688534 | ₹9.9 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | sunilal L1 | KELTRON LIGHTING DIVISION L2 |
|---|---|---|---|---|---|
| 1.00Annual Plan-HIGHMAST MINIMAST AMC - MAINTENANCE-Project No. S0586/25 of Adoor Municipality-General Electrical Work | |||||
| 1.00 | OD366102/2025-2026:Supply Conveyance, installation, testing and commissioning of 300W, LED Flood light output greater than 120lumen/W, 6500 K, 37000 lux with IP 66 protection, IK 08 Impact Protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 10 KV and Aluminium pressure die-cast Powder coated housing, Polycarbonate cover complete with THD less than 10%, RoHS compliant, duly wired up for use on Input Voltage 120 to 277 V, AC supply. Driver compartment should be separately accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer), Philips make, BVP485 LED370 CW FLNB PSU SPD GR or equivalent Crompton/ Bajaj make with 5 years Warranty. | 6 | each | 21,215 ₹1.3 L | 10,434.78 ₹62,608.68 |
| 1.00 | OD366105/2025-2026:Supply Conveyance, installation, testing and commissioning of 200W, LED Flood light output greater than 120lumen/W, 6500 K, 24000 lux with IP 66 protection, IK 07 Impact Protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 10 KV and Aluminium pressure die-cast Powder coated housing, Polycarbonate cover complete with THD less than 10%, RoHS compliant, duly wired up for use on Input Voltage 220 to 240 V, AC supply. Driver compartment should be separately accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer), Philips make, BVP283 LED240 CW FG SY5WB 200W PSU SPD or equivalent Crompton/ Bajaj make with 3 years Warranty. | 30 | each | 9,574 ₹2.9 L | 9,565.22 ₹2.9 L |
| 1.00 | OD366103/2025-2026:Supply Conveyance, installation, testing and commissioning of 150W, LED Flood light output greater than 120lumen/W, 6500 K, 18000 lux with IP 66 protection, IK 07 Impact Protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 4 KV and Aluminium pressure die-cast Powder coated housing, Polycarbonate cover complete with THD less than 10%, RoHS compliant, duly wired up for use on Input Voltage 220 to 240 V, AC supply. Driver compartment should be separately accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer), Philips make, BVP283 LED181 CW FG SY5WB 150W PSU or equivalent Crompton/ Bajaj make with 3 years Warranty. | 8 | each | 9,412 ₹75,296 | 9,130.43 ₹73,043.44 |
| 1.00 | OD363756/2025-2026:Providing and fixing double scaffolding system for a height up to 7m as required, as per Specification for Civil Works, Item No. 4.72X in PRICE | 1 | job | 2,332 ₹2,332 | 5,913.04 ₹5,913.04 |
| 1.00 | OD363750/2025-2026:Charges for lowering the old and damaged light fittings from the top of high/mini mast, removing them, fitting the new lamps in place, giving connections and lifting and fixing in position etc. as required. | 44 | each | 798 ₹35,112 | 3,913.04 ₹1.7 L |
| 1.01 | OD363755/2025-2026:Charges for conveying the existing unserviceable lamps and materials without further damages, as directed at site. | 44 | each | 188 ₹8,272 | 1,304.35 ₹57,391.40 |
| 1.01 | OD366521/2025-2026:Supplying and fixing Sintex make heavy duty junction box IP65/IP67, Resistance to Impact IK 07, including 25mm conical cable gland with provision for fixing 30A, 12 Way Bakelite Black Screw Terminal Wire Connectors and with suitable clamping arrangement. | 9 | each | 1,656 ₹14,904 | 7,304.35 ₹65,739.15 |
| 1.01 | OD367212/2025-2026:Supply and fixing 30A, 4 Way Bakelite Connector Strip - Black Screw Terminal Connection Block 4 Way Wire Connector for connecting 2 wires in each way with sufficient insulation cover for the Terminal Connector. | 12 | each | 391 ₹4,692 | 660.87 ₹7,930.44 |
| 1.01 | OD367213/2025-2026:Supply and fixing 30A, 12 Way Bakelite Connector Strip - Double Row Barrier Black Terminal, Globomotive make or equivalent for connecting 2 wires in each way with sufficient insulation cover for the Terminal Connector. | 12 | each | 336 ₹4,032 | 591.3 ₹7,095.60 |
Tender Value
₹8.3 L
EMD Value
₹20,734
Closing Date
28 Jan 2026, 6:00 pmClosed
Asst. Engineer LID andEW Section Adoor Municipalty
Asst. Engineer LID and EW Section Adoor Municipalty
HIGHMAST MINIMAST AMC - MAINTENANCE-Project No. S0586/25
2026_LSGD_828756_1
P1/3606/25 Phase 4_26 AMC
Open Tender
Electrical and Maintenance Works
365 days
LID and EW Section Adoor Mnicipality
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,830
Yes
₹20,734
Yes
7 May 2026
19 Jan 2026
30 Jan 2026
19 Jan 2026
28 Jan 2026
19 Jan 2026
Annual Plan-HIGHMAST MINIMAST AMC - MAINTENANCE-Project No. S0586/25 of Adoor Municipality-General Electrical Work
OD366102/2025-2026:Supply Conveyance, installation, testing and commissioning of 300W, LED Flood light output greater than 120lumen/W, 6500 K, 37000 lux with IP 66 protection, IK 08 Impact Protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 10 KV and Aluminium pressure die-cast Powder coated housing, Polycarbonate cover complete with THD less than 10%, RoHS compliant, duly wired up for use on Input Voltage 120 to 277 V, AC supply. Driver compartment should be separately accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer), Philips make, BVP485 LED370 CW FLNB PSU SPD GR or equivalent Crompton/ Bajaj make with 5 years Warranty.
OD366105/2025-2026:Supply Conveyance, installation, testing and commissioning of 200W, LED Flood light output greater than 120lumen/W, 6500 K, 24000 lux with IP 66 protection, IK 07 Impact Protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 10 KV and Aluminium pressure die-cast Powder coated housing, Polycarbonate cover complete with THD less than 10%, RoHS compliant, duly wired up for use on Input Voltage 220 to 240 V, AC supply. Driver compartment should be separately accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer), Philips make, BVP283 LED240 CW FG SY5WB 200W PSU SPD or equivalent Crompton/ Bajaj make with 3 years Warranty.
OD366103/2025-2026:Supply Conveyance, installation, testing and commissioning of 150W, LED Flood light output greater than 120lumen/W, 6500 K, 18000 lux with IP 66 protection, IK 07 Impact Protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 4 KV and Aluminium pressure die-cast Powder coated housing, Polycarbonate cover complete with THD less than 10%, RoHS compliant, duly wired up for use on Input Voltage 220 to 240 V, AC supply. Driver compartment should be separately accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer), Philips make, BVP283 LED181 CW FG SY5WB 150W PSU or equivalent Crompton/ Bajaj make with 3 years Warranty.
OD363756/2025-2026:Providing and fixing double scaffolding system for a height up to 7m as required, as per Specification for Civil Works, Item No. 4.72X in PRICE
OD363750/2025-2026:Charges for lowering the old and damaged light fittings from the top of high/mini mast, removing them, fitting the new lamps in place, giving connections and lifting and fixing in position etc. as required.
OD363755/2025-2026:Charges for conveying the existing unserviceable lamps and materials without further damages, as directed at site.
OD366521/2025-2026:Supplying and fixing Sintex make heavy duty junction box IP65/IP67, Resistance to Impact IK 07, including 25mm conical cable gland with provision for fixing 30A, 12 Way Bakelite Black Screw Terminal Wire Connectors and with suitable clamping arrangement.
OD367212/2025-2026:Supply and fixing 30A, 4 Way Bakelite Connector Strip - Black Screw Terminal Connection Block 4 Way Wire Connector for connecting 2 wires in each way with sufficient insulation cover for the Terminal Connector.
OD367213/2025-2026:Supply and fixing 30A, 12 Way Bakelite Connector Strip - Double Row Barrier Black Terminal, Globomotive make or equivalent for connecting 2 wires in each way with sufficient insulation cover for the Terminal Connector.
90.6.5.20:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 4.00 sq mm
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
OD363758/2025-2026:Supply, installation, testing and commissioning of freestanding LT Panel Board with base supported on angle iron frame, made of 16 gauge sheet steel, phosphatised and painted, dust and vermin proof, Weatherproof, IP 65/ IP67 having two separate compartments arranged vertically with required no. of knock outs for cable entry as per the approved design, the upper compartment for accommodating Single phase Energy Meter with provision for fixing 1No. HRC Fuse, neutral link & DIN rail suitable for fixing ELCB and lower compartment as control module having DIN rails in two rows, suitable for fixing MCB/ isolator /Contactor/ Timer etc. and with provision for locking of both the compartments.
OD363742/2025-2026:Supply, installation, testing and commissioning of freestanding LT Panel Board as control module with base supported on angle iron frame, made of 16 gauge sheet steel, phosphatised and painted, dust and vermin proof, Weatherproof, IP 65/ IP67 with required no. of knock outs for cable entry, DIN rail arranged in two rows suitable for fixing Isolator/MCB/ELCB and fixtures for fixing timer, contactor etc. as required with provision for earthing as per the approved design and with provision for locking the panel board.
OD366412/2025-2026:Overhauling Charges of damaged Freestanding LT Panel Board with base supported on angle iron frame, by replacing the damaged 16 gauge sheet steel, angle iron frame etc. and phosphatised and painted to make it dust and vermin proof and Weatherproof and to make it suitable for accommodating Energy Meter with provision for fixing HRC Fuse, Neutral Link & providing DIN rail suitable for fixing Isolator/ ELCB/ MCB/ Contactor/ Timer etc. and with provision for locking the compartment.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.3:Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD363748/2025-2026:Supply and providing 32A, 415 V Bakelite fuse fitting in the existing meter board and giving connections etc.
OD363740/2025-2026:Supply of 32A, 415V, 2way Neutral link mounted on DMC/ SMC base and fixing in the existing Energy Meter Box and giving connections etc.
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
OD363745/2025-2026:Supply and fixing 415V, 25A, 3 Pole Mini contactor, AC 3 Rating with AC coil.
OD366855/2025-2026:Supply and fixing 230V, 25A, 3 Pole Mini contactor, AC 3 Rating with AC coil, L&T make, Model MNX 22 or equivalent in the existing LV Panel Board and giving connections etc. as required..
OD363753/2025-2026:Supply and installation of Programmable time switch 24 Hour (Timer) with dual contactor/ Light Sensor suitable for outdoor light fittings, Hager/ L&T / Havells make.
OD363739/2025-2026: Supply and fixing 6A, Two way Toggle Switch in the indication panel of LV Panel / Switch Board.
OD363754/2025-2026:Supply and fixing Aviation obstruction Integral LED aviation light comprising of Die-cast aluminum housing with Red polycarbonate dome for better illumination, Integral driver, Super flux 5mm 302nos LEDs, and with Ingress Protection : IP65, Bajaj make Code - 110731, Type : BGAV 302 or other Techno-commercially equivalent.
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD363737/2025-2026: Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / Earth bus etc. as required including drilling necessary holes as required.
OD363747/2025-2026:Supplying and clamping 25 mm dia. corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination points using suitable size GI / painted MS saddles spacing not exceeding 60cm on surface including making good the damages, colour washing etc. as required.
OD363752/2025-2026:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall, as per item specification No. 50.18.7.4.1 for Civil works. T
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
OD363741/2025-2026:Supplying and installation of supports / suspenders, anchor bolts etc. made out of suitable size channel sections, single section square tube, slotted angles, flats, MS plates, iron rods etc. as required including painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc. as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1391338.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
BOQ_1391338.xls
BOQ • 0.26 MB
viewsbd.pdf
Tender Documents • 1.64 MB
FT.pdf
Tender Documents • 0.68 MB
PA.pdf
Tender Documents • 1.27 MB
AffidavitandITC.pdf
Tender Documents • 1.02 MB
Download all tender documents and submit your bid