Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.3 LAccepted-AOC 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹77.4 L+₹5.0 L (6.91%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹80.3 L+₹8.0 L (11.0%)Rejected-AOC 275 GOLE BUILDING ROAD 1ST B ROAD SARDARPURA JODHPUR RAJ 342003 | JODHPUR | RAJASTHAN | 342003 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹1.1 Cr+₹40.7 L (56.3%)Rejected-AOC CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L4 | Rejected-AOC Not Lowest | |
| 5 | Rejected-Technical 19 CHANAN SINGH PARK KIRBY PLACE DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | - | Rejected-Technical Not Accepted |
Tender Value
₹90 L
EMD Value
₹1.6 L
Closing Date
1 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JODHPUR
HQ CWE AF JODHPUR
85903 E8 REPAIRS TO JOINTS AND CRACKS USING EPOXY RESIN MORTAR AND ELASTOMERIC CONCRETE OF RIGID PORTION AND APPLICATION OF PME ON FLEXIBLE PORTION AT AF STN JODHPUR
2021_MES_484216_2
85903/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF JODHPUR
As per NIT
7 documents required · 7 mandatory
₹1,000
GE AF JODHPUR
₹1.6 L
Yes
20 May 2022
14 Jan 2022
3 Feb 2022
14 Jan 2022
1 Feb 2022
20 Jan 2022
14 Jan 2022 - 14 Jan 2022
60 days
Amount
NOTE FOR ITEMS NO. 02 TO 24 :- The work will be carried out as per user requirement from 1830 hrs to 0600 Hrs. The deployment of labour and T&P arrangement on the Runway shall be intimated to the contractor by 0800 Hrs each day in the moring. The contractor has to provide necessary arrangement such as lights etc and quote the rate accordingly for considering late working hours at night. Nothing extra will be paid on this account.
M&L for raking out sealing compound from existing expansion joints of dimension 25 mm to 30 mm wide and 45 mm deep, removing the debris from site by sweeping the concrete surface with brooms, cleaning with compressed air, treating sides and bottom of the joints with primer as per manufacturer's directions and filled with preformed closed cell polyethylene backup rod/strip of 25-32 mm dia, sealing with pitch free polyurethane grey sealant (minimum depth of sealant above backup rod shall be 10 mm) conforming to BS-5212 (Type FB) and applying masking tape on edges of joints to prevent accidental spillage of sealant and removing the masking tape after application of sealant complete all as specified and directed. Note :-Incase of any variation in width or depth of joint, the same is deemed to be included in quoted rates by the contractor as in Sch 'A'/BOQ items as above. The contractor shall not be entitled for any extra claim on this account.
M&L for raking out sealing compound from existing construction/dummy joints of dimension 16 mm to 24 mm wide and 40 mm deep, removing the debris from site by sweeping the concrete surface with brooms, cleaning with compressed air, treating sides and bottom of the joints with primer as per manufacturer's directions and filled with preformed closed cell polyethylene backup rod/strip of 16-25 mm dia, sealing with pitch free polyurethane grey sealant (minimum depth of sealant above backup rod shall be 10 mm) conforming to BS-5212 (Type FB) and applying masking tape on edges of joints to prevent accidental spillage of sealant and removing the masking tape after application of sealant complete all as specified and directed. Note :-Incase of any variation in width or depth of joint, the same is deemed to be included in quoted rates by the contractor as in Sch 'A'/BOQ items as above. The contractor shall not be entitled for any extra claim on this account.
M&L for raking out sealing compound from existing construction/dummy joints of dimension 10 mm to 15 mm wide and 30 mm deep, removing the debris from site by sweeping the concrete surface with brooms, cleaning with compressed air, treating sides and bottom of the joints with primer as per manufacturer's directions and filled with preformed closed cell polyethylene backup rod/strip of 13-18 mm dia, sealing with pitch free polyurethane grey sealant (minimum depth of sealant above backup rod shall be 10 mm) conforming to BS-5212 (Type FB) and applying masking tape on edges of joints to prevent accidental spillage of sealant and removing the masking tape after application of sealant complete all as specified and directed. Note:-Incase of any variation in width or depth of joint, the same is deemed to be included in quoted rates by the contractor as in Sch 'A'/BOQ items as above. The contractor shall not be entitled for any extra claim on this account.
Material and Labour Chipping and/or neatly Cutting of existing loose concrete at cracks on Runway/Taxi track/ pavement by using diamand cutter. Cutting of cracked portion shall not be less than 100 mm wide and 45 mm deep. Cleaning the dirt and all loose material fanned with air blower and air blasting the cleaned surface applying proprietory primer on surfaces to obtained tack and finally filling in Elastomeric Concrete, (Mix shall be prepared as per manufacturer instruction) to obtained a true surface and finally tooling the set surface with hand tools complete all as specified and directed. Note :- (i) The rate shall be include for providing masking tape at joints and formwork required if any at spalled joints edges. (ii) The quoted rate deemed to be included for making good to disturbed joint filling around the area where material is applied. (iii) All material shall only be procured directly from manufacturer.
Material and Labour Cutting existing loose patches / spalled edges of concrete pavement in square / rectangular/ triangular shape to a depth not less than 25mm removing debris out side MD land sweeping the patches with broom, cleaning with compressed air and applying epoxy resin mortar (proportion as specifed) incl necessary form work for sides of joints, sprinkle , a thin layer of dust free fine sand (QUARTS SAND 10 No) and applying a coat on top of surface with epoxy resin primer @ 0.45 Kg/Sqm and finally filling the joints with sealing compound complete all as specified and directed.
M&L for cleaning the surface by brushing with wire brushes for removing caked mud etc, sweeping with compressor air blower to remove all loose dust and dirt etc/taking out dust/ existing material with compressed air and making the surface free from dust, drying the surface and applying Two coats of polymeric modified emulsion (PME) by using self propelled emulsion distribution uniformly or towed emulsion pressure sprayer , equipped for spraying the PME uniformly and mopping the total undiluted PME @ 1.00 litre per sqm in two coats in ratio 1:1 (PME: water) and ensure uniform finish of total area complete all as specified and directed. Note:- The tenderer shall take into consideration the following points while quoting his rate for the above item:- (i) No price adjustment shall be applicable if excess quantity of polymer modified emulsion mentined above is used, depending upon conditin of the surface to be treated. (ii) Special care shall be taken to fill gaps/cracks with 6mm to 2.36 mm size coarse sand as per manufacturers instructins and quoted rate is included for repir of gaps/cracks. (iii) Cost of trial patch 15mx15m deemed to be included in rates quoted for above item.
Demolition of PQC of any description & in any position not otherwise specifically provided for (unreinforced) and removing outside MD land complete all as specified.
M&L for pavement quality concrete (PQC) of flexural strength 45 kilogram per sqcm in field as per design mix (as per IRC 44-2017 ) thickness of concrete 300-350mm using non circular synthetic polyster fibre reinforcement @ 0.25% by weight of cement including form work for laying in bays complete all as specified and as directed by the Engineer -in - Charge. Note: (i) Admixture is if required as per design mix shall be added. Cost of Admixture including dosage plant and labour for mixing shall be deemed to be include the quoted rate of this item. (ii) Polyester triangular fibres as secondary reinforcement mixed in concrete shall be measured and paid for separataly under respective item of this schedule. However, mixing shall be deemed to be included in the quoted rate (the constant shall be apply based on design mix). (iii) Construction joints, dummy (construction joints and expansion joints shall be measured and paid separately under respective items. (iv) Deduction shall be made in PQC for quantity for expansion joints. (v) As per IRC provision minimum cement content is 360 kg/cum for the purpose of pricing this item, the cement content shall be considered as 400 kg/cum. Minus price adjustment shall be made based on quoted rate for supply only cement, incase of quantity of cement is used less than 400 kg/cum. However No plus price adjustment shall be made to the quoted rate of excess quantity of cement used beyond 400 kg/cum. (vi) The quoted rate shall deemed to be include the cost cement mortar bund. (vii) The cutting of joint will be done using diamond cutter. (viii) The quoted rate shall deemed to be include the cost for cutting unshaped existing concrete edges into rectangular shape by using diamond cutter.
Supply only polyester triangular fibres 6/12mm long with circum circle diameter 30-35 micron, designed for melting point of 240-260 degree celsius and having specific gravity of 1. 34 to 1.40. of approved manufactured complete all as specified and as directed by the Engineer -in - Charge.
M&L for broom finished surface of concrete pavement while concrete is green complete complete all as specified and as directed by the Engr-in - Charge.
Material & labour for 10mm thick layer of sand filling complete all as specified and directed by the Engineer-in-Charge.
Material & labour for high density polythene film (transparent colour) in single layer of 400 micron thickness of virgin quality (as per ASTMD 2103, IS-2508) laid with side and end overlapping not less than 300mm complete all as specified and directed by the Engineer-in-Charge.
M&L for Forming construction joint 150 mm deep and 10 mm wide (using diamond cutter) and sealed with polyurethane sealent complies with BS:5212 and priming the sides provision of closed cell polyethylene backup rod 12mm dia and applying masking tape on edges of joint to prevent accidential spillage of sealent and removing the masking tape after sealent is applied complete all as specified and directed.
M&L for Forming contraction (Dummy) joint 100 mm deep and 8 mm wide (using diamond cutter) and sealed with polyurethane sealent complies with BS:5212 and priming the sides provision of closed cell polyethylene backup rod 10mm dia and applying masking tape on edges of joint to prevent accidential spillage of sealent and removing the masking tape after sealent is applied complete all as specified and directed.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, disposal of unserviceable materials, debris and rubbish outside MD land complete all as specified and as directed by the Engineer -in - Charge.
M&L for Framed work such as grills, gratings etc. with ends of bars shouldered and or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by the Engineer -in - Charge.
M&L for preparation of new steel surface of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M & L for preparation of old concrete/bitumen surfaces on rigid / flexible portion of Runway/Taxi track by brushing, washing, rubbing by gunny bags over 10cm width or girth of any description and applying one coat of Ist quality exterior weather proof water base emulsion on lines, dashes arrows, letters etc any tint paint all as directed by Engineer-in-Charge.
All as per item No 19 above but n exc 10 cm width or girth all as directed by Engineer-in-Charge.
M & L for preparation of old concrete/bitumen surfaces on rigid / flexible portion of Runway/Taxi track by brushing, washing, rubbing by gunny bags over 10cm width or girth of any description and applying one coat of synthetic enamel paint to lines, dashes, arrows, letter etc (First quality ) any tint paint all as directed by Engineer-in-Charge.
All as per item no 21 aove but n.exc 10 cm in width or girth when unconnected with other painting or when painted in a different tint paint all as directed by Engineer-in-Charge.
M&L for clearing/cutting bushes, scrubs, grass, vegitation from side/berms of storm water drains by and runway shoulders and adjoining area by manual means complete all as specified and as directed by the Engineer -in - Charge.
M&L for surface excavation for lowering to existing Runway/PTT berms by excavation manually up to depth not exc 25 cm and getting out including removing of all excavated material outside MOD land complete all as specified and as directed.
Jeet Construction
JANGID BUILDERS
M M SHAWL Engineers and contractors pvt ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .