Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAdmitted-Finance NANDA VIHAR DHANAURI PATTI RAMNAGAR ROAD KASHIPUR DISTT U S NAGAR UTTARAKHAND | ALMORA | UTTARAKHAND | 244715 | ₹2.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.0 Cr+₹29,246.47 (0.15%)Admitted-Finance KHASRA NO 203 KHARAKPUR DEVIPURA KASHIPUR | KASHIPUR | ₹2.0 Cr+₹29,246.47 (0.15%) | L2 | Admitted-Finance |
| 3 | L3₹2.0 Cr+₹72,978.97 (0.37%)Admitted-Finance DEHRADUN VICTORIA CROSS VIJETA GABAR SINGH URJA BHAWAN KANWALI ROAD DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹2.0 Cr+₹72,978.97 (0.37%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S GOVERDHAN TRADERS L3 | KUMAUN ELECTRICALS L2 | SHIKHAR ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00Supply Item | ||||||
| 1.01 | Supply of F-clamp for pcc pole with N/B
(As per Specification of RESPO & UPCL) | 80 | No | 28,160 ₹33,228.8 | 28,080 ₹33,134.4 | 27,920 ₹32,945.6 Lowest |
| 1.02 | Supply of Bracing Clamp for SP-55 with N/B
(As per Specification of RESPO & UPCL) | 100 | No | 35,200 ₹41,536 | 35,100 ₹41,418 | 34,900 ₹41,182 Lowest |
| 1.03 | Supply of Nut & Bolts
(As per Specification of RESPO & UPCL) | 510 | Kg | 56,610 ₹66,799.8 | 57,120 ₹67,401.6 | 55,845 ₹65,897.1 Lowest |
| 1.04 | Supply of X ARM CLAMP FOR PCC POLE WITH N/B
(As per Specification of RESPO & UPCL) | 130 | No | 37,050 ₹43,719 | 37,180 ₹43,872.4 | 36,920 ₹43,565.6 Lowest |
| 1.05 | Supply of PP & CLAMP WITH N&B ST POLE SP-55
(As per Specification of RESPO & UPCL) | 100 | No | 28,500 ₹33,630 | 28,600 ₹33,748 | 28,400 ₹33,512 Lowest |
| 1.06 | Supply of Stay Clamp for Pcc Pole
(As per Specification of RESPO & UPCL) | 70 | No | 21,560 ₹25,440.8 | 21,350 ₹25,193 | 20,930 ₹24,697.4 Lowest |
| 1.07 | Supply of STAY INSULATOR
(As per Specification of RESPO & UPCL) | 60 | No | 3,120 ₹3,681.6 | 3,060 ₹3,610.8 | 2,940 ₹3,469.2 Lowest |
| 1.08 | Supply of DANGER BOARD
(As per Specification of RESPO & UPCL) | 400 | No | 1,80,400 ₹2,12,872 | 1,80,800 ₹2,13,344 | 1,79,920 ₹2,12,305.6 Lowest |
| 1.09 | Supply of PG Clamp Dog to Dog
(As per Specification of RESPO & UPCL) | 110 | No | 49,610 ₹58,539.8 | 49,720 ₹58,669.6 | 49,478 ₹58,384.04 Lowest |
Tender Value
Refer Docs
EMD Value
₹3.4 L
Closing Date
6 Mar 2025, 11:00 amClosed
Superintending Engineer
33 11 KV Sub Station Campus ND Nagar Industrial Estate Bazpur Road KASHIPUR US NAGAR 244713
Replacement of ACSR Weasel Conductor to ACSR Dog and AAAC, AL-59, 99 sq.mm (Covered Conductor) in 11 KV RAIPUR FEEDER and Supply of its associated decentralized material under Electricity Distribution Division Jaspur.
2025_UPCL9_80570_1
33/EDC(K)/2024-25
Open Tender
Electrical Works
Item Rate
365 days
Jaspur
As Per NIT and Tender Documents
3 documents required · 3 mandatory
₹11,800
EE EDD Kashipur
₹3.4 L
22 Mar 2025
21 Feb 2025
6 Mar 2025
21 Feb 2025
6 Mar 2025
21 Feb 2025
Supply Item
Supply of F-clamp for pcc pole with N/B (As per Specification of RESPO & UPCL)
Supply of Bracing Clamp for SP-55 with N/B (As per Specification of RESPO & UPCL)
Supply of Nut & Bolts (As per Specification of RESPO & UPCL)
Supply of X ARM CLAMP FOR PCC POLE WITH N/B (As per Specification of RESPO & UPCL)
Supply of PP & CLAMP WITH N&B ST POLE SP-55 (As per Specification of RESPO & UPCL)
Supply of Stay Clamp for Pcc Pole (As per Specification of RESPO & UPCL)
Supply of STAY INSULATOR (As per Specification of RESPO & UPCL)
Supply of DANGER BOARD (As per Specification of RESPO & UPCL)
Supply of PG Clamp Dog to Dog (As per Specification of RESPO & UPCL)
Supply of STAY CLAMP FOR SP-55 WITH NUT & BOLT (As per Specification of RESPO & UPCL)
Supply of Earth Wire Clamp (As per Specification of RESPO & UPCL)
Supply of 11 KV CABLE TIES FOR PIN INSULATOR (As per GTP & Specification of UPCL)
Supply of 11 KV IPC FOR COVERED TO COVERED COND. (As per GTP & Specification of UPCL)
Supply of 11 KV IPC FOR COVERED TO BARE CONDUCTOR (As per GTP & Specification of UPCL)
Supply of 11KV AAAC COVERED COND. AL-59,99 SQ.MM. (As per GTP & Specification of UPCL)
Supply of BARBED WIRE
Supply of 11 KV TENSION CLAMP WITH BAIL & IPC (As per GTP & Specification of UPCL)
11 KV AAAC Conductor Work
Cartage of the following material by private truck from store centre to work site dump store approx. distance 0 to 20 Km. including loading into truck and unloading at work site. Dump store and carriage from dump store to pit site.
PCC Pole
STP SP-55 Pole
Cartage of other material (other than poles) by vehicle fro Store Center to nearest construction site Store including loading and unloading at both ends.
Head Load Cartage of following material road to work site approx. distance 0 to 1 Km. including loading and unloading.
PCC Pole
STP SP-55 Pole
Head load cartage of Small material from road to site
Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work
Erection of Single PCC pole in proper level and alignment alongwith fixing of all accessories, like top channel & clamps as per RESSPO construction Manual.
Erection of Single STP SP-55 pole in proper level and alignment alongwith fixing of all accessories, like top channel & clamps as per RESSPO construction Manual.
Route cleareance by cutting of tree branches / proning, loping and chopping of trees for 11 KV line.
Erection of Double STP SP-55 pole in proper level and alignment alongwith fixing of all accessories, like top channel, X-bracing & clamps as per RESSPO construction Manual.
Grouting of pole in size 0.45x0.45x1/9 of the support in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement,sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO construction Manual.
Muffing of poles size 0.45 cm x 0.60 cm radious with cc 1:3:6 (1 cement : 3 coarse sand : 6 graded stone 10mm nominal size) block size 45cm height from ground level including cost of cement, stone and sand etc.
Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod to proper depth and connecting the earth electrode with the helpof G.I. wire as per construction manual.
Fabrication of M.S. Channel Angle iron after cutting in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESSPO sehedule and local approved drawing.
Excavation of earth for Stay pit of size 0.6x0.6x1.2mtr in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work
Fixing , tightening and nozzaling of 11 KV Stay with pole and stay rod on required tension as per drawing / RESSPO manual.
Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement,sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO Manual.
Dismantling of existing HT line in Weasel Conductor including disc fitting, Insulator, clamps, Nut & Bolts and consumer connections and Street light connections etc.
Painting of poles with angle and channel and all steel part by one coat of Rod Oxide Primer and two coats of aluminium Paint and two strip of fluorescent altemate Red and White paint 30 Cm wide upto 1.5 Mtrs. From ground level.
Laying, Spreading, Stringing and sagging of 11 KV line in Dog Conductor with fixing of all accessories.
Making of section pole for existing HT line complete in all respect.
Fixing of Danger Board and number plate complete by providing clamps of M.S. Flat 50x6 mm and Nuts & Bolts, danger Boards of M.S. Sheet 2 mm Thick 11''x7'' size.
Sagging/Resagging of HT Line with binding & Jumpering.
Back Cartage of other material (other than poles) by vehicle including loading and unloading at both ends.
Replacement of Jumper of HT Line
FIXING OF 11KV 90KN TENSION CLAMP B&IPC
FIXING OF 11KV IPC FOR COVERED - COVERED
FIXING OF 11KV IPC COVERED TO BARE COND.
Straightening of tilted PCC / ST Poles complete as per RESPO drawing.
LAYING SPREADING,STRINGING AAAC CONDUCTOR
Fixing of 11 KV CABLE TIES FOR PIN INSULATOR
Renozzling of existing stay sets.
KUMAUN ELECTRICALS (BID ID -364130)
M/S GOVERDHAN TRADERS (BID ID -363961)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .