Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹8.2 L
EMD Value
₹16,444
Closing Date
16 Mar 2026, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, PWD, DDED
Purta Bhavan,4 th Floor,Kachari Road,Balurghat,Dakshin Dinajpur,Pin-733101
Supply and Laying Cable from LT Panel Room to different Feeder Pillar Box at Balurghat DH , Dakshin Dinajpur, RN 23002311, Project Id - HF252647459S000
2026_WBPWD_1015582_1
WBPWD/EE/DDED/e-NIT-05 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Percentage
60 days
Balurghat, Dakshin Dinajpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹16,444
10 Apr 2026
27 Feb 2026
18 Mar 2026
27 Feb 2026
16 Mar 2026
27 Feb 2026
Supplying and fixing 415V, TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
i) 100 A TPN SFU ( Make- L&T / Legrand /ABB / Haggar / Siemens)
i) 125 A TPN SFU (ake- L&T / Legrand /ABB / Haggar / Siemens )
Supplying and fixing 415V, TPN on load front operated Changeover switch open execution type in SS enclosure/cubical with nuts bolts etc
i) 250 A ( ake- L&T / Legrand /ABB / Haggar / Siemens )
Supply and delivery of following 1.1 KV grade XLPE AL armoured cables with submission of test report and warranty certificate for atleast 3 years from the OEM (Make: KEI, Polycab, Havells, RR Kabel//Havells) [NS]
(i) 4 core 240 sqmm [LT Panel Room to main Feeder Pillar Box]
(ii) 4 core 95 sqmm [ Souhadra Feeder Pillar to Near Morgue Feeder Pillar Box]
(iii) 4 core 35 sqmm [Morgue Feeder Pillar to Mourge TPN DB]
Laying of 4 core 240 sqmm cable on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting. (F1/2e)
Laying only 4 Core 240 sqmm Cable through existing RCC / Hume Pipe .
Laying of one No. cable of 4 Core 240 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of one No. cable of 4 Core 95 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of one No. cable of 35 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below [F4/7c]
(i) 4 core 240 sqmm
(ii) 4 core 95 sqmm
(iii) 4 core 35 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : [F5/8b]
(i) 4 core 240 sqmm
(ii) 4 core 95 sqmm
(iii) 4 core 35 sqmm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required ( Dual Line , One For Future) i) 150 mm dia
ii) 50 mm dia
Making cable trench after cutting the pitch road with own tools and tackles with minimum depth of 600 mm and 300 mm wide and after laying of Cable through 150mm GI Pipe the trench levelling up with sand and restoring surface duly rammed and with concrete mixer of minimum depth 150mm including compacting to its original G.L. etc. complete including costs of labour and materials..
Add GST @18%
Add LWC @ 1%
stage.html
html • 0.03 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.09 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.87 MB
Tendernotice_2.pdf
PDF • 5.39 MB
Tendernotice_3.pdf
PDF • 0.52 MB
BOQ_2494680.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .