Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.1 LAccepted-AOC ALMORA | UTTARAKHAND | 263601 | ₹72.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹74.4 L+₹2.2 L (3.10%)Rejected-AOC | ₹74.4 L+₹2.2 L (3.10%) | L2 | Rejected-AOC L2 |
| 3 | L3₹76.4 L+₹4.3 L (5.96%)Rejected-AOC T STATE BANJARAWALA DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹76.4 L+₹4.3 L (5.96%) | L3 | Rejected-AOC L3 |
| 4 | L4₹79.7 L+₹7.5 L (10.4%)Rejected-AOC N A | ₹79.7 L+₹7.5 L (10.4%) | L4 | Rejected-AOC L4 |
| 5 | L5₹79.7 L+₹7.6 L (10.5%)Rejected-AOC RZ M 21 NAND BLOCK MAHAVIR ENCLAVE PALAM NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹79.7 L+₹7.6 L (10.5%) | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | JAI SAI ENGINEERING L5 | SHREE BALAJI ASSOCIATES L3 | JOSHI ELECTRIC WORKS L4 | MANEESH CONSTRUCTION L1 | M/s Star Sales Corporation L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | 2 | Nos | 1,749 ₹3,498 | 1,450 ₹2,900 | 1,518 ₹3,036 | 700 ₹1,400 Lowest | 1,410.21 ₹2,820.42 |
| 2.00 | Wiring for light point /fan point/exhaust fan point/call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed PVC conduit with modular switch,modular plate,suitable G.I.box and earthing the point with 1.5sq.mm.FRLS PVC insulated copper conductor single core cable etc. asrequired, complete in all respect.Group C | 102 | point | 1,295 ₹1,32,090 | 1,073 ₹1,09,446 | 1,124 ₹1,14,648 | 1,200 ₹1,22,400 | 1,044.32 ₹1,06,520.64 Lowest |
| 3.00 | Wiring for circuit/submain wiring alongwith earth wire with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable surface/ recessed medium class PVC conduit. | 670 | Nos | 202 ₹1,35,340 | 170 ₹1,13,900 | 178 ₹1,19,260 | 209 ₹1,40,030 | 165.87 ₹1,11,132.9 Lowest |
| 4.00 | Wiring for circuit/submain wiring alongwith earth wire with 2x2.5sq.mm+1x2.5sq.mm of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium class PVC conduit as required. | 330 | Mtr | 242 ₹79,860 | 201 ₹66,330 | 211 ₹69,630 | 247 ₹81,510 | 195.77 ₹64,604.1 Lowest |
| 5.00 | Same as above item no 3 but for 2x6.0sq.mm+1x6.0sq.mm earth wire | 50 | Nos | 387 ₹19,350 | 320 ₹16,000 | 336 ₹16,800 | 390 ₹19,500 | 312.51 ₹15,625.5 Lowest |
| 6.00 | S/D of 1x1.5sq.mm FRLS PVC insulated copper conductor single core cable in existing surface/recess PVC conduit.Complete in all respect. | 610 | Mtr | 39 ₹23,790 | 32.5 ₹19,825 | 35 ₹21,350 | 40 ₹24,400 | 32.03 ₹19,538.3 Lowest |
| 7.00 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable . | 500 | Nos | 50 ₹25,000 | 41 ₹20,500 | 44 ₹22,000 | 51 ₹25,500 | 40.57 ₹20,285 Lowest |
| 8.00 | S/F of modular type 5/6 amps switch on the existing switch board,complete in all respect. | 22 | Mtr | 90 ₹1,980 | 75 ₹1,650 | 79 ₹1,738 | 90 ₹1,980 | 73.32 ₹1,613.04 Lowest |
| 9.00 | Same as above but for 3 pin 5/6 amps socket ,complete in all respect. | 22 | Nos | 107 ₹2,354 | 88 ₹1,936 | 161 ₹3,542 | 100 ₹2,200 | 86.84 ₹1,910.48 Lowest |
| 10.00 | S/F of suitable size GI box with modular plate & cover in front and 6 pin 5/6 & 15/16 amps modular switch and socket on surface or in recess,complete in all respect. | 9 | each | 517 ₹4,653 | 427 ₹3,843 | 449 ₹4,041 | 500 ₹4,500 | 417.15 ₹3,754.35 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
27 Apr 2026, 12:00 pmClosed
As Per Tender Notice
As Per Tender Notice
Internal electrification work in multi-storey car parking Khetikhaan of Champawat district.
2026_RES_94084_1
RWD_EM_01_2026
Open Tender
Electrical Works
Item Rate
605 days
khetikhan champawat
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
EE E/M RWD DEHRADUN
₹2.1 L
9 Jul 2026
10 Apr 2026
27 Apr 2026
10 Apr 2026
27 Apr 2026
10 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | - | Nos | - | - |
| - | Wiring for light point /fan point/exhaust fan point/call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed PVC conduit with modular switch,modular plate,suitable G.I.box and earthing the point with 1.5sq.mm.FRLS PVC insulated copper conductor single core cable etc. asrequired, complete in all respect.Group C | - | point | - | - |
| - | Wiring for circuit/submain wiring alongwith earth wire with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable surface/ recessed medium class PVC conduit. | - | Nos | - | - |
| - | Wiring for circuit/submain wiring alongwith earth wire with 2x2.5sq.mm+1x2.5sq.mm of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium class PVC conduit as required. | - | Mtr | - | - |
| - | Same as above item no 3 but for 2x6.0sq.mm+1x6.0sq.mm earth wire | - | Nos | - | - |
| - | S/D of 1x1.5sq.mm FRLS PVC insulated copper conductor single core cable in existing surface/recess PVC conduit.Complete in all respect. | - | Mtr | - | - |
| - | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable . | - | Nos | - | - |
| - | S/F of modular type 5/6 amps switch on the existing switch board,complete in all respect. | - | Mtr | - | - |
| - | Same as above but for 3 pin 5/6 amps socket ,complete in all respect. | - | Nos | - | - |
| - | S/F of suitable size GI box with modular plate & cover in front and 6 pin 5/6 & 15/16 amps modular switch and socket on surface or in recess,complete in all respect. | - | each | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_111335.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.33 MB
BOQ_111335.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .