| Sl No | Description | Qty | Unit | M/s Shree Riddhi Siddhi Buildwell Limited L1 | M/s Surindera Traders L2 | M/s R S Construction L3 |
|---|---|---|---|---|---|---|
| 1.00 | Schedule 'A' Part-I.
Construction of Single living Accn for JCO – 08 Nos (D/S) complete all as specified and shown on drgs | 1 | Lump sum | 93,85,900 ₹93.9 L | 77,28,000 ₹77.3 L | 29,45,000 ₹29.4 L |
| 2.00 | Construction of Single living Accn for 11 Hav and 62 Ors (T/S) complete all as specified and shown on drgs | 3 | Lump sum | 70,50,000 ₹2.1 Cr | 2,36,00,000 ₹7.1 Cr | 2,14,70,000 ₹6.4 Cr |
| 3.00 | Construction of Single living Accn for 12 Hav 62 Ors (T/S) complete all as specified and shown on drgs | 1 | Lump sum | 70,50,000 ₹70.5 L | 2,36,00,000 ₹2.4 Cr | 2,47,00,000 ₹2.5 Cr |
| 4.00 | Scooter Stand for 100 scooters complete all as specified and shown on drgs. | 1 | Lump sum | 37,60,000 ₹37.6 L | 27,44,000 ₹27.4 L | 38,00,000 ₹38 L |
| 5.00 | Construction of Cook house and dinning hall complete all as specified and shown on drgs. | 1 | Lump sum | 2,44,40,000 ₹2.4 Cr | 1,34,00,000 ₹1.3 Cr | 1,53,90,000 ₹1.5 Cr |
| 6.00 | Construction of Administrative Building (D/S) complete all as specified and shown on drgs. | 1 | Lump sum | 2,43,46,000 ₹2.4 Cr | 1,86,90,000 ₹1.9 Cr | 85,50,000 ₹85.5 L |
| 7.00 | Construction of open car parking for 14 cars complete all as specified and shown on drgs. | 1 | Lump sum | 40,23,200 ₹40.2 L | 28,83,000 ₹28.8 L | 33,25,000 ₹33.3 L |
| 8.00 | Construction of Bycycle cum scoter stand for 30 scooters complete all as specified and shown on drgs. | 1 | Lump sum | 13,63,000 ₹13.6 L | 7,77,000 ₹7.8 L | 14,25,000 ₹14.3 L |
| 9.00 | Construction of OR institute complete all as specified and shown on drgs. | 1 | Lump sum | 51,98,200 ₹52.0 L | 30,46,000 ₹30.5 L | 36,10,000 ₹36.1 L |
| 10.00 | Construction of Guard house armories and ancillaries complete all as specified and shown on drgs. | 1 | Lump sum | 1,13,74,000 ₹1.1 Cr | 97,14,000 ₹97.1 L | 79,80,000 ₹79.8 L |
Updated dates
Tender Value
₹32 Cr
EMD Value
₹15 L
Closing Date
20 Oct 2025, 6:00 pmClosed
HQ CE PATHANKOT ZONE
HQ CE PATHANKOT ZONE
PROVN OF OTM ACCN IN ALHILAL
2025_MES_721619_2
89319/E8
Open Tender
Civil Works
900 days
GE Palampur
As per Tender documents
7 documents required · 7 mandatory
₹3,000
GE Palampur
₹15 L
Yes
28 Nov 2025
3 Sept 2025
28 Oct 2025
3 Sept 2025
20 Oct 2025
6 Oct 2025
Amount
Schedule 'A' Part-I. Construction of Single living Accn for JCO – 08 Nos (D/S) complete all as specified and shown on drgs
Construction of Single living Accn for 11 Hav and 62 Ors (T/S) complete all as specified and shown on drgs
Construction of Single living Accn for 12 Hav 62 Ors (T/S) complete all as specified and shown on drgs
Scooter Stand for 100 scooters complete all as specified and shown on drgs.
Construction of Cook house and dinning hall complete all as specified and shown on drgs.
Construction of Administrative Building (D/S) complete all as specified and shown on drgs.
Construction of open car parking for 14 cars complete all as specified and shown on drgs.
Construction of Bycycle cum scoter stand for 30 scooters complete all as specified and shown on drgs.
Construction of OR institute complete all as specified and shown on drgs.
Construction of Guard house armories and ancillaries complete all as specified and shown on drgs.
Construction of General Storage Accn (D/S) complete all as specified and shown on drgs
Construction of Tradesmen shop complete all as specified and shown on drgs.
Construction of Drying and ironing shed complete all as specified and shown on drgs
Construction of JCO mess and club (S/S) complete all as specified and shown on drgs
Construction of Education building complete all as specified and shown on drgs.
Construction of garage for Scania Loader complete all as specified and shown on drgs.
Construction of Garage for Scania SBA-III Gun towing Veh (18 No) complete all as specified and shown on drgs
Construction of Garage for Fd Gun (09 Nos) complete all as specified and shown on drgs
Construction of Storage Accn for artillery unit complete all as specified and shown on drgs
Construction of Artilerry miniature range complete all as specified and shown on drgs
Construction of instruction shed for Gunnery training complete all as specified and shown on drgs.
Construction of Religious institute complete all as specified and shown on drgs
Construction of Garrage for 08 scooter complete all as specified and shown on drgs
Construction of Alarm post complete all as specified and shown on drgs
Construction of Flag staff complete all as specified and shown on drgs
Construction of Basket ball court complete all as specified and shown on drgs
Construction of Volley ball court complete all as specified and shown on drgs
Lumpsum price worked out by the contractor for "earth work, site clearance and site development" as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for "Internal water Supply Works" as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for "Internal Electrification" as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for "Plumbing work Works" as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the contractor for "Protective Works" as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for Road, Path & Culverts Works" as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for "Sewage Dipsosal Works" as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for "Area Drainage" as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for "External water supply" as listed in Schedule 'A' Part-X.
Lumpsum price worked out by the contractor for "External Electrification" as listed in Schedule 'A' Part-XI.
Lumpsum price worked out by the contractor for "Compound wall and steel gate" as listed in Schedule 'A' Part-XII.
Lumpsum price worked out by the contractor for "Connecting Passage" as listed in Schedule 'A' Part-XIII.
Lumpsum price worked out by the contractor for "Lightening Protection" as listed in Schedule 'A' Part-XIV.
Lumpsum price worked out by the contractor for "Hot Water Apparatus" as listed in Schedule 'A' Part-XV.
Lumpsum price worked out by the contractor for "Demolition and Dismantling Works" as listed in Schedule 'A' Part-XVI.
INTERNAL ELECTRIFICATION Supply and fixing Led luminaire 600 mm x 600 mm, 35/36 watt LED 5500-6500 K, 220V, AC surface mounted type with high efficiency having efficacy 120 lumens / watt, power factor more than 0.90, IP 20 soft glare free light complete with driver, holders etc including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing round shape 12 watt, 5500-6500 K, 220 volts, AC, 50 Hz surface type with efficiency having efficacy 120 lumens / watt, power factor more than 0.90, IP 20 soft glare free light complete with drivers, holders LED lamp suitable for ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and Fixing High performance IP66 streetlight 20 watt, 5500-6500 K, housing made of die –cast aluminum, with street optic lens, with all accessories and connecting up with all including provision of 3 core flexible copper wire of size 1.5 sqmm from ceiling rose, and 20 Watt LED light etc drawn through and including 32mm bore GI light grade brackets upto 1.0m length with suitable fixing accessories on walls, complete all as specified and as directed.
Supply and fixing LED luminaire 4 feet, 20 watt LED, 5500-6500 K , 220 V AC Recess mounted type with high efficiency having efficacy 120 lumens / watt, extruded aluminium with a satin finish PMMA diffuser, for stand alone and seamless end-to-end connectivity having power factor more than 0.90, IP 20 soft glare free light complete including connecting up with copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing auto clean curved glass kitchen chimney 90cm, 1500 cum / hrs suction power, wall mounted filter surface area 78 x 30 sqcm, Max noise db 58, inbuild 1.5 watt LED lamp 2 numbers (Hood primus plus energy HC SC KK 90, baffle filter, Touch control, Black in colour) including stranded installation with duction kit and duck pipe complete all as specified and as directed.
Supply and fixing VTPN Loadline DBs as per IEC 61439-3, with 250 Amps copper bus bar, 2 neutral bar, 2 earth bar, fully insulated bus bar, blanking plates (without MCBs and MCCBs) Double door 4-way suitable for upto 160 Amps MCCB incomer, IP 43 protection 415 Volts, AC, 50 Hz complete all as specified and directed.
Supply and fixing of telephone socket is fitted in robust designed assembly plates smug fit on the wall with assembly plates with suitable modules, white in color, dust free glossy finish complete all as specified and as directed.
S & F blanking plate for MCB DBs complete all as specified and directed.
M & L for earthing complete with G.I earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit less than 2.25m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected galvanized earth leadwise 4mm by mean of bolts, nuts, check nuts and washer of iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 M, including PCC chamber in PCC (1:2:4), type B1, using (20mm graded stone aggregate) mild steel frame made out of angle iron od size 40mm x 40mm x 6mm thick duly painted with two coats of synthetic enamel paint over one red oxide zinc chrome primer hinged with and including pre-fabicated RCC cover 40mm thick with handle, watering arrangements with funnel internally secured with wire mesh with 20mm dia light grade GI pipe for watering, 15mm dia medium grade, GI pipe for earth pipe for earth wire protection with and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 connected to DBs all as specified and indicated including testing on completion.
EXTERNAL ELECTRIFICATION Supply, installing, commissioning & testing transformer suitable for 250 KVA (Level-2) step down floor mounted outdoor type 11/.433, 3 phase, 50 Hz AC, IS: 1180-2014 ISI marked, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connected on LV side in accordance with vector symbol Dyn-11 (vector group 4) with neutral brought out on LV side with for earthing and having tapping on HV side for constant output so as to alter/vary secondary voltage by (Tapping range + 5 % to - 10% in equal step of 2.5 % ) changed by means of manually operated " off load" taps changing gear. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories. The limit of temperature rise after continuous full load run as specified in IS-1180 (Part-I) 2014 and BEE Certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :-
(i) Oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (ii) Silica gel breather with connecting pipe, first fill of dehydrating agent. (iii) Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (iv) Air release valve plug (v) One cable box on LV side (Secondary) consisting of 04 Nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints (vi) Explosive vent (vii) 01 No 100 mm dial type thermometer vapour pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (viii) Thermometer pocket on tank cover (ix) 04 Nos plain solid CI datachable rollers (x) Two Nos Earthing terminals marking plate. (xi) Rating plate and terminal marking plate (xii) Extra bushing for neutral outside the cable box brought out on LV side. (xiii) First filling of oil conforming to IS and tested upto 60 KV dielectric strenght (xiv) Lifting lugs (xv) Oil drain valve with plug (xvi) One cable box on HV side (Primary) consisting of 01 cable gland suitable for reception of taking in HT cable including gland joints (xvii) Hand hole of sufficient size to assess interior of tank (xviii) Dehydrating breather with first filling of Dehydrating agent (xix) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strip. (xx) Rating plate with terminal marking plate (xxi) Inspection cover.
Note :- (a) Transformer shall be Pre-Commisioned by SEI after installation. (b) Cost of all necessary T&P and measuring devices shall be provided by the contractor without any extra cost. (c) Drawing of transformer shall be approved by GE before placing the order. (d) Pre-dispatch inspection at factory premises shall be carried out by rep of Accepting Officer. Contractor shall intimate the planned date of inspection well in advance. All incidental expenditure for getting the inspection/testing in the factory premises shall be borne by the contractor including transportation and administration arrangement for the rep of accepting officer without any extra cost to the department. (e) PCC foundation, plateform as per manufacturer recommendation (one metre high from ground level) shall be provided by the contractor without any extra cost.
Material and labour for cable route indicator post of size 900mm x 300mm x 100mm made of precast cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate, rounded tops as directed and embeded in ground (450 mm below ground and 450 mm above ground level) with PCC (1:3:6) type C-1, using 20 mm graded stone aggregate block of size 350mm x 150mm x 450mm, including 5 mm thick plastering all round of exposed surface of post above ground with CM (1:4) and finished even and smooth without using extra cement, applying two coats of cement base paint on plastered surface including writing letters (like HT UG cable, __ feeder etc.) with synthetic enamel paint in brown colour in suitable size including earth work and form work complete all as specified and as directed.
Supply and fixing energy efficient LED street light fitting of 45W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection with suitable size of wire from junction box to street light fitting, fixing the light fitting with and including bracket made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25mm x 4mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : Morethan 70 and CCT : 5500-6500 K. (g) IP rating : IP65. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing of Hot press Moulded SMC (Sheet Moulding Compound) junction box of inside dimention 240mm x 130mm x 110mm including 4 Nos Aluminium Stud terminal of suitable size and one Nos MCB SP 6 Amps and fixed on pole with clamps. bolts and nuts / grouted in coping of pole complete with two coat of synethictic enamel paint powder coated as provided by manufacturermake complete all as specified and as directed. Make: Sintex / Hensel
Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 1.6 mm thick MS sheet and MS angle section 50mm x 50mm x 6mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank treatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The Four Pole busbar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of the Four Pole busbar. The cubical incomer MCCB as well as outgoing shall have aluminium Four Pole extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size "F" class insulator complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Four Pole, Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators
MCCB 500 Amp, FP 50 Hz, 415 V, 36KA, adjustable type – 01 Nos (Incoming)
MCCB 200 Amp, FP 50 Hz, 415 V, 36KA, adjustable type – 01 Nos (Out going)
MCCB 160 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 01 Nos (Out going)
MCCB 100 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 02 No (Out going)
LED Indicated Lamp (R,Y,B) one Set-01
Internal power and control wiring with not less than 4 sqmm PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 1.6 mm thick MS sheet and MS angle section 50mm x 50mm x 6mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank treatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The Four Pole busbar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of the Four Pole busbar. The cubical incomer MCCB as well as outgoing shall have aluminium Four Pole extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size "F" class insulator complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Four Pole, Aluminium bus bar 160 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators
MCCB 100 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 01 No (Incoming)
MCCB 63 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 01 No (Out going)
MCCB 32 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 02 Nos (Out going)
MCB 32 Amp, DP 50 Hz, 240 V, 10KA – 02 Nos (Out going)
MCB 16 Amp, DP 50 Hz, 240 V, 10KA – 02 Nos (Out going)
Timer switch light sensing type with outer sensor having current capacity 16A & control from 1 lux to 100K lux , 230 Volts, 50 HZ and 2 pole power contactor 16 Amps capacity single phase, 230 Volts 50 HZ suitable for 1 phase distribution -01 Each.
LED Indicated Lamp (R,Y,B) one Set-01
Internal power and control wiring with not less than 4 sqmm suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 1.6 mm thick MS sheet and MS angle section 50mm x 50mm x 6mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank treatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The Four Pole busbar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of the Four Pole busbar. The cubical incomer MCCB as well as outgoing shall have aluminium Four Pole extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size "F" class insulator complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Four Pole, Aluminium bus bar 250 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators
MCCB 160 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 01 No (Incoming)
MCCB 63 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 02 No (Out going)
MCB 32 Amp, DP 50 Hz, 240 V, 10KA – 02 Nos (Out going)
MCB 16 Amp, DP 50 Hz, 240 V, 10KA – 01 Nos (Out going for S/light)
Timer switch light sensing type with outer sensor having current capacity 16A & control from 1 lux to 100K lux , 230 Volts, 50 HZ and 2 pole power contactor 16 Amps capacity single phase, 230 Volts 50 HZ suitable for 1 phase distribution -01 Each.
LED Indicated Lamp (R,Y,B) one Set-01
Internal power and control wiring with not less than 4 Sqmm suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 1.6 mm thick MS sheet and MS angle section 50mm x 50mm x 6mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank treatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The Four Pole busbar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of the Four Pole busbar. The cubical incomer MCCB as well as outgoing shall have aluminium Four Pole extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size "F" class insulator complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Four Pole, Aluminium bus bar 160 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators
MCCB 100 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 01 No (Incoming)
MCCB 63 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 01 No (Out going)
MCCB 40 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 01 Nos (Out going)
MCB 32 Amp, DP 50 Hz, 240 V, 10KA – 02 Nos (Out going)
MCB 16 Amp, DP 50 Hz, 240 V, 10KA – 02 Nos (Out going)
Timer switch light sensing type with outer sensor having current capacity 16A & control from 1 lux to 100K lux , 230 Volts, 50 HZ and 2 pole power contactor 16 Amps capacity single phase, 230 Volts 50 HZ suitable for 1 phase distribution -01 Each.
LED Indicated Lamp (R,Y,B) one Set-01
Internal power and control wiring with not less than 4 Sqmm suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 1.6 mm thick MS sheet and MS angle section 50mm x 50mm x 6mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The Four Pole busbar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of the Four Pole busbar. The cubical incomer MCCB as well as outgoing shall have aluminium Four Pole extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size "F" class insulator complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Four Pole, Aluminium bus bar 250 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators
MCCB 160 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 01 No (Incoming)
MCCB 63 Amp, FP 50 Hz, 415 V, 25KA, adjustable type – 03 No (Out going)
MCB 32 Amp, DP 50 Hz, 240 V, 10KA – 03 Nos (Out going)
MCB 16 Amp, DP 50 Hz, 240 V, 10KA – 01 Nos (Out going)
Timer switch light sensing type with outer sensor having current capacity 16A & control from 1 lux to 100K lux , 230 Volts, 50 HZ and 2 pole power contactor 16 Amps capacity single phase, 230 Volts 50 HZ suitable for 1 phase distribution -01 Each.
LED Indicated Lamp (R,Y,B) one Set-01
Internal power and control wiring with not less than 4 Sqmm suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply, installation & testing of main distribution feeder pillar box cubical, indoor type, factory fabricated out of 2 mm thick CRCA sheet of size not less than 800mm x 800mm x 240mm, having inbuilt locking arrangement with 2 Nos lock and keys, rubber gasket packing, earthing arrangement, door handles, danger notice board, inside & outside painted with two coats of polyster powder coated, incl common alluminium busbar of 200 amps rating - 04 Nos. mounted on porcelain supports, suitably spaced & enclosed in chamber, cable entry holes, cable glands, copper wired of suitable size including lugs, fixing of main board on the wall with necessary civil work, DB should have sufficient space to accomodate incl neccessary civil/plastering work for making good the disturbed surfaces incl supply & fixing of following items complete :-
(i) MCCB 4 pole, 415 volts, 40 amp, 25 KA breaking capacity - 1No. (incoming)
(ii) MCB SPN 16 Amp, 230 V, 10 KA breaking capacity, 'C' series - 4 Nos. (outgoing)
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32mm x 6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fix HT SFU of 11 KV LBSF panel outdoor complete with, 630A load break swtich, 200 Amps D O set, earth swtich, PVC sleeved, copper busbar for incoming, door interlocking mechanism, epoxy insulatr for busbar supports , HV cable box provide for end termination at incoming side, end plate provided at outgoing side for end termination etc including taking out old unservcible GOD mechanism complete all as specified and directed. Note :- LBSF should be placed/grouted on brick masonary plateform of size 3.0m x 3.0m x 1.2m height. The rates for construction to plateform are measured and paid separately under relevant item of BOQ
M&L for construction LBSF plateform of size 3.0m x 3.0m and height 1.2 mtr from normal ground level using brick masonary wall, PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundation and top of the plateforn and plastering all visible surface by using 1:3 cement mortar, 15mm thick plaster all as specified and directed
EXTERNAL WATER SUPPY : Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 150 mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly.(ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 100 mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supply and fixing DI fitting upto 150 mm bore pipe line for reducing/bends (any type radius and angle) tapers any type, straight, bend, increasing decreasing or double socket extra Tee pieces single branch Y 'Junction' double branch cross collers cap etc complete all as specified and as directed.Note:- Make of DI fittings shall be same make as DI pipe or as per recommendation of DI pipe manufacturer
Material and labour for Construction of brick masonary valve pit chamber size 90cm x 90cm x 90cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40mm x 40mm x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
Material and labour for Construction of brick masonary valve pit chamber size 120cm x 120cm x 120cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40mm x 40mm x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
ROAD PATH AND CULVERT :-Providing and applying 2.5 mm thick retro-reflective road marking strips of specified shade/colour using hot thermoplastic material, applied by a fully or semi-automatic thermoplastic paint applicator machine fitted with a profile shoe heater, operated by an experienced operator on a prepared road surface. The work includes the cost of all materials, labour, tools and plant (T&P), and cleaning the road surface of all dust, debris, oil, grease, and foreign material, complete all as per the directions of the Engineer-in-Charge.
HOT WATER APPARATUS :- Supply, installing, commissioning and testing of Solar Water Heating system (Flat Plate Collector) based on indirect transfer of heat of capacity 1500 Ltrs Per Day having makeup tank capacity of 10 ltr including electric backup stainless steel hot water tank suitable for inlet water with chlorine and fluoride content up to 100 PPM and comprising of solar flat plate collector, collector stand assembly with collector 'A' Size aluminium box collector comprising of following :-
Insulated stainless steel Hot water storage tank non pressure type made of stainless steel grade 04 Cr 18 NI or 07 Cr 18 NI of IS 1570 (Part-3)-1985, TIG Welded of 300 Ltrs capacity, non-magnetic tank with stainless steel fittings with following specification -01 No shall be insulated with 40 mm thermal grade PU insulation with FRP Cladding Tank stand assembly shall be made of Size 38 x38 x 4 mm duly pre-treated and stove enamelled with black colour paint.
Provisions of electrical back up with min 3 KW heating element - One Job Solar water heating system shall be provided on roof of single / double storey building. The electrical back up connection shall be tapped from sub main board provided at ground floor.
Heat exchanger shall be cage type and made of stainless steel tube of grade 04 Cr 18 NI or 0718 NI of IS 1570 (Part-2) 1885
All other pipe /civil work, steel staging work for PVC tank, electrical work, outlet and inlet thermometer, air release valves, check valves, gate valves, controls and instruments etc. all as required shall be paid as under relevant iems seperately. Make : The complete solar water heating system shall be one of the following makes: SOLOHROME SYSTEM INDIA LTD (PARWANOO HIMACHAL) / SURYA JYOTI DEVICE INDIA LTD ( ROPAR PUNJAB) / INTER SOLAR.
Supply, installing, commissioning and testing of Solar Water Heating system (Flat Plate Collector) based on indirect transfer of heat of capacity 500 Ltrs Per Day having makeup tank capacity of 7 ltr including electric backup stainless steel hot water tank suitable for inlet water with chlorine and fluoride content up to 100 PPM and comprising of solar flat plate collector, collector stand assembly with collector 'A' Size aluminium box collector comprising of following :-
Insulated stainless steel Hot water storage tank non pressure type made of stainless steel grade 04 Cr 18 NI or 07 Cr 18 NI of IS 1570 (Part-3)-1985, TIG Welded of 300 Ltrs capacity, non-magnetic tank with stainless steel fittings with following specification -01 No shall be insulated with 40 mm thermal grade PU insulation with FRP Cladding Tank stand assembly shall be made of Size 38 x38 x 4 mm duly pre-treated and stove enamelled with black colour paint.
Provisions of electrical back up with min 3 KW heating element - One Job Solar water heating system shall be provided on roof of single / double storey building. The electrical back up connection shall be tapped from sub main board provided at ground floor.
Heat exchanger shall be cage type and made of stainless steel tube of grade 04 Cr 18 NI or 0718 NI of IS 1570 (Part-2) 1885
All other pipe /civil work, steel staging work for PVC tank, electrical work, outlet and inlet thermometer, air release valves, check valves, gate valves, controls and instruments etc. all as required shall be paid as under relevant iems seperately. Make : The complete solar water heating system shall be one of the following makes: SOLOHROME SYSTEM INDIA LTD (PARWANOO HIMACHAL) / SURYA JYOTI DEVICE INDIA LTD ( ROPAR PUNJAB) / INTER SOLAR.
Supply, installing, commissioning and testing of Solar Water Heating system (Flat Plate Collector) based on indirect transfer of heat of capacity 200 Ltrs Per Day having makeup tank capacity of 5 ltr including electric backup stainless steel hot water tank suitable for inlet water with chlorine and fluoride content up to 100 PPM and comprising of solar flat plate collector, collector stand assembly with collector 'A' Size aluminium box collector comprising of following :-
Insulated stainless steel Hot water storage tank non pressure type made of stainless steel grade 04 Cr 18 NI or 07 Cr 18 NI of IS 1570 (Part-3)-1985, TIG Welded of 300 Ltrs capacity, non-magnetic tank with stainless steel fittings with following specification -01 No shall be insulated with 40 mm thermal grade PU insulation with FRP Cladding Tank stand assembly shall be made of Size 38 x38 x 4 mm duly pre-treated and stove enamelled with black colour paint.
Provisions of electrical back up with min 3 KW heating element - One Job Solar water heating system shall be provided on roof of single / double storey building. The electrical back up connection shall be tapped from sub main board provided at ground floor.
Heat exchanger shall be cage type and made of stainless steel tube of grade 04 Cr 18 NI or 0718 NI of IS 1570 (Part-2) 1885
All other pipe /civil work, steel staging work for PVC tank, electrical work, outlet and inlet thermometer, air release valves, check valves, gate valves, controls and instruments etc. all as required shall be paid as under relevant iems seperately. Make : The complete solar water heating system shall be one of the following makes: SOLOHROME SYSTEM INDIA LTD (PARWANOO HIMACHAL) / SURYA JYOTI DEVICE INDIA LTD ( ROPAR PUNJAB) / INTER SOLAR.
S&F Rotational moulded poly-ethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified having capacity of 500 Ltrs complete all as specified and directed.
S&F Rotational moulded poly-ethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified having capacity of 750 Ltrs complete all as specified and directed.
S&F Rotational moulded poly-ethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified having capacity of 2000 Ltrs complete all as specified and directed.
Schedule of Credit Works as listed in Schedule 'A' Part-XVII has been attached in tender in PDF format amount of schedule i.e Rs 17,13,683.53 shall be deducted from the total amount of BOQ to arive at the contract sum.
M/s Surindera Traders (BID ID -3448926)
M/s R S Construction (BID ID -3445676)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.28 MB
EMDRGS2.rar
Additional Documents • 2.56 MB
SFDRGS4.rar
Additional Documents • 2.77 MB
LISTOFDRAWING3.rar
Additional Documents • 0.81 MB
STRDRGS5.rar
Additional Documents • 35.19 MB
Tender42.pdf
Tender Documents • 31.50 MB
TDSTDDRGS6.rar
Additional Documents • 19.36 MB
TDSTDSCANDRGS7.rar
Additional Documents • 27.66 MB
AMENDEDDRGSASON22AUG25.rar
Additional Documents • 8.18 MB
ARCHDRGS1.rar
Additional Documents • 12.61 MB
BOQ_816318.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid