Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance APAR HOUSE CORPORATE PARK V N PURAV MARG CHEMBUR MUMBAI 400 071 | MUMBAI | MUMBAI | MAHARASHTRA | 400071 | Admitted-Finance |
| 2 | Admitted-Finance SURVEY NO 104 2 3 UMARKOI RD FALANDI DADRA AND NAGAR HAVELI DADRA NAGAR HAVELI 396230 | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396230 | Admitted-Finance |
| 3 | Admitted-Finance F 151 TO 154 M I A ALWAR 301030 ALWAR ALWAR RAJASTHAN 301030 | ALWAR | RAJASTHAN | 301030 | Admitted-Finance |
| 4 | Admitted-Finance BUILDING NO 488 CMC 30 CHERTHALA CHERTHALA PO MUTTOM BAZAR ALAPPUZHA KERALA 688524 | ALAPPUZHA | KERALA | 688524 | Admitted-Finance |
| 5 | Admitted-Finance TRIPURA ENCLAVE 7 III 59 BALLYGUNGE CIRCULAR ROAD BALLYGUNGE KOLKATA WEST BENGAL 700019 | KOLKATA | WEST BENGAL | 700019 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
8 Apr 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM(SHIP REPAIR MATERIALS)
Ship Repair Materials Department, Cochin Shipyard Limited, Ravipuram, Kochi, Kerala, 682015
As per tender documents
2025_CSL_231724_1
SR9/GePNIC/BEAS/CABLE/02
Open Tender
Electrical Goods/Equipment
Supply
45 days
COCHIN
As per tender documents
2 documents required · 2 mandatory
₹0
Exempted
20 May 2025
1 Apr 2025
9 Apr 2025
1 Apr 2025
8 Apr 2025
1 Apr 2025
Amount
SUPPLY OF MARINE CABLES as per following specifications
16 CORE 0.75SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
16 CORE 1SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
1CX2X0.75SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
20CX2X0.75SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
24CORE 1SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
3CORE 2.5SQMM MARINE CABLE 3CORE 2.5SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
3CORE 4SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
3CORE 6SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
3CX2X0.5SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
4CORE 10SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
4CORE 0.75SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
6PX1.5SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
7CX2X0.75SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
1PX1.5SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
1PX1.5SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
4CORE 1.5SQMM MARINE CABLE Armoured Fire resistant control cable with improved EMC screening Conductor: Stranded Copper conductor, shall comply IEC 60228 Class 2 Insulation: XLPE Rated Voltage: .6/1kV Cabling: Cabling, cores twisted together and to be in round construction Screen: 100% Copper tape Armour: Copper wire braid, coverage>90%, IEC 60092-350 Sheath: Polyolefin SHF1, IEC 60092-360 Core identification: Number code/Color code Marine Approval: ABS/BV/CCS/CRS/DNV/LR/RINA/IRS Fire Performance: IEC 60332-1-2 Fire Resistant: IEC 60331-1 Halogen Free: IEC 60754 Series Smoke Emission: IEC 61034 Oil Resistance: IEC 60811-404 Conditions Operating temperature range: -40 to 80 deg C
2 C 1.5 SQMM MULTISTRAND COPPER CONDUCTOR XLPE INSULATED FILTER TAPED ARMOUR -COPPER WIRE BRAIDED OVERALL PVC SHEATHED HF,LS CABLE, Marine class approval cable data sheet & Navy test approval Certificate to be provided for technical approval. Quotation willbe not considered without data sheet.. * ITEM REQUIRED URGENTLY, * AFTER PO DELIVERY WITH IN 45 DAYS is technically accepted.
Thermocable ltd (BID ID -838996)
SUYOG ELECTRICALS LTD (BID ID -838998)
Nangalwala Industries Pvt. Ltd. (BID ID -838832)
NAVIOS AUTOMATION PVT LTD (BID ID -839016)
NICCO EASTERN PRIVATE LIMITED (BID ID -838757)
APAR INDUSTRIES LTD UNIT UNIFLEX CABLES (BID ID -838975)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .