Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC VIII BADWALA ARKEDIA GRANT PO PREMNAGAR DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹38.9 L+₹2.2 L (6.02%)Rejected-AOC WING NO 7 2 10 PREMNAGAR DEHRADUN UK | L2 | Rejected-AOC R | |
| 3 | L3₹45.9 L+₹9.2 L (25.0%)Rejected-AOC 3 VIJAY PARK CHAKRATA ROAD DEHRADUN 248 001 UK | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC R |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
11 Sept 2021, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
SPECIAL REPAIR TO BUILDING NO T 284 AND T 285 AT WT SEC AND BOUNDARY WALL AND GATE IN NORTH COMPLEX AT IMA DEHRADUN
2021_MES_466853_1
GE/IMA/76/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA Dehradun
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE IMA Dehradun
₹83,000
Yes
16 Sept 2021
10 Aug 2021
13 Sept 2021
11 Aug 2021
11 Sept 2021
28 Aug 2021
Amount
Demolition of brick or stone masonary built in cement mortar including pre cast articles complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and directed
Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for key, scdrubbing down with water etc complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area n.exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area exc 1.5 Sqm but n.exc 4.0 Sqm each complete all as specified and directed.
Taking down shutters of any description exceeding 1.00 Sqm n. Exc 2.00 sqm each complete all as specified and directed.
Taking down shutters from the frames area n.exc 1.00 Sqm each complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n. Exc 15cm thickness (below or above) ground level complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n' exc. 1.5 m in depth and getting out in any type soil complete all as specified and directed.
Excavation over areas n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soil complete all as specified and directed.
Removing surplus excavated soil to a distance n.exc 50 metre & depositing where directed at a level n.exc 1.5 metre above the starting point complete all as specified and directed.
PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete and sub base of floor etc complete all as specified and directed.
PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, benching, cills, pcc gola, holddfast and the like including weathering, slightly rounded or chamfered angles and throating, including necessary from work etc complete all as specified and directed.
75mm thick PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in plinth protection or similar places, and finishing the surface even and smooth without using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meters and at every change of direction and filling the same with sealing compound grade 'A' including necessary formwork etc complete all as specified and directed
Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Brick work with sub class B bricks, straight or curved on exc 6m mean radious built in cement mortar (1:4) complete all as specified and directed.
Brick work with sub class B bricks, except bricks straight or curved on plan exc 6m mean radious built in cement mortar (1:6) complete all as specified and directed. Note :- serviceable bricks obtained from demolition to be reused.
Brick work with sub class B bricks styraight or curved on plan to any radious in half brick thick walls built in CM 1:4 complete all as specified and directed.
2nd class hard wood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
30mm thick IInd class hard wood glazed and skeleton shuttered open rebated and prepared to receive glass gauge/(with sash bar) edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass or gauged etc size of members of shutters as specified in SSR Part I section 8 clause 8.24(a) complete all as specified and directed.
Butt hinges, 100 mm long, medium weight, cold rolled, mild steel and fixed to frame complete all as specified and directed.
Butt hinges, 75 mm long, medium weight, cold rolled, mild steel and fixed to frame complete all as specified and directed.
200 mm long aluminium anodised barrel tower bolt extruded section complete all as specified and directed.
100 mm long aluminium anodised barrel tower bolt extruded section complete all as specified and directed.
Extruded aluminium alloy handle 150 mm long fabricated type anodised complete all as specified and directed.
Extruded aluminium alloy handle 100 mm long fabricated type anodised complete all as specified and directed.
300mm long aluminium anosized sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section of cast aluminium alloy complete all as specified and directed.
Machine cut Kota stone slab flooring 20-25 mm thick over and including 20mm thick cement sand screed in CM 1:6 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing with and including dismantling old stone slab complete all as specified and directed.
Machine cut Kota stone slab 20-25 mm thick as in riser of steps, skirting, dado and pillars etc laid over and including 10mm backing coat in CM 1:4 on brick or concrete surface base and jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding, rubbing and polishing etc with and including dismantling old stone slab complete all as specified and directed.
12-16mm thick Lakha stone (Granite) in path/vertical surface (square/rectangular) polished area of each tiles exceeding 0.36 sqm in floors/vertical surface etc. Over and including 15mm thick screed bed in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.
100 mm x 100mm x 100mm thick coloured granite stone machine cut, dressed corner edges laid in cobaled pattern in path (square/ rectangular) as directed by AGE over and including 15 mm thick screed bed in CM 1:4, and stone laid as per direction and joint shall be filled as per cobaled path pattern set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 100 mm thick PCC 1:3:6 type C2 using 20 mm graded aggregate as per directions of Engr in Charge including demolition of existing black top surfaces of road complete all as specified and directed.
Rounding to edges of stone slab one edge, such as in steps cooking platform and other similar situations complete all as specified and directed.
Sand stone decorative lamp of one piece of size 45 x 45 cm and height not less than 60 cm as per existing pattern of IMA main Gate and approved by GE. Complete all as specified and directed.
Stainless steel grade 304 letter of size 250mm x 50mm x10mm fixed on granite stone slab complete all as specified and directed.
10 mm thick earthenware Antique brick tiles of NATURAL SHAPE and colour, size of tile 230mm x 75 mm on vertical surfaces of wall over and including 10 mm epoxy based adhesive using suitable spacers 3-5mm thick complete all as specified and directed.
Rendering 15mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement and mixed with water proofing compound as per manufactures instructions, complete all as specified and directed Note :- WPC will be measured paid as supply only under respective items separetely.
Rendering 15mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement and complete all as specified and directed.
Rendering 15mm thick plaster on other than fair faces of brick work or concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed
Supply only intergral water proofing compound complete all as specified & directed.
Pre- painted colour galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as directed including dismantling existing sheet.complete all as specified and directed
Pre- painted colour galvalume aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding ridges to wall fixed with self tapping screws etc including dismantling existing AC complete all as specified and directed
Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed..
Preparation of old steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as directed.
Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paintover a coat of primer complete all as directed.
Preparation of old plastered surfaces of walls by brooming down or steel wire brushing scrapping down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots and applying one coat of white wash on wall complete all as directed.
Complete removing of existing treatment from wall / ceilling and applying two coat of cement base paint complete all as specified and directed.
Preparation of new or previously untreated surface of wall and applying three coats of white wash complete all as directed.
Use & waste for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter including fair finished surfaces complete all as specified and directed.
Demolition of cement concrete of any description and in any position complete all as specified and directed.
Use and waste of formwork to sides and soffits of floors or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports etc. and similar work of fair finished flat surface of concrete complete all as specified and directed.
Raking out joints of existing masonry built in cement mortar complete alll as specfied and directed.
Use and waste of formwork to sides of concrete pillar, columns, posts strutts complete all as specified and directed.
RCC M -25 (Design Mix) using 20mm graded crushed stone aggregate as in foundations, including rafts, footing, foundation beams, plinth beams, bases for columns etc, basement slab, under-reamed piles and mass concrete etc complete all as specified and directed.
RCC M -25 (Design Mix) , type B-1using 20mm graded crushed stone aggregate as in beams, cantilever bressummers lintel over 1.5 m span etc complete all as specified and directed.
RCC M -25 (Design Mix) using using 20mm graded crushed stone aggregate as in column ,pillars, piers,posts and struts complete all as specified and directed.
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Rolled structural mild steel work as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
Ornamental and intricate design mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Steel window factory made with side hung shutter including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded including cutting holes in wall for inserting holdfast and making good the dismantled portion in cm 1;3 or sement consrete 1;2; 4 as required complete all as specified and directed as per drawing no TD032 sheet 1/10 to 10/10
Steel window factory made with side hung shutter including projecting type hinges with steel handle and steel peg stay complete with out glazing bars dovetailed or welded including cutting holes in wall for inserting holdfast and making good the dismantled portion in cm 1;3 or sement consrete 1;2; 4 as requiredcomplete all as specified and directed as per drawing no TD032 sheet 1/10 to 10/10
Steel ventilator with top hung shutter including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded complete all as specified and directed as per drawing no TD032 sheet 1/10 to 10/10
4 mm thick sheet glass, ordinary quality & glazing with oil putty or fixed with wooden beads in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed
600x600mmx4mm thick 'E' board classic factory finish as in false ceiling including supply and fixing 'Tee" grid frame work made of special section of MS galvanized sheet 0.30mm thick, bottom portion painted with cellular nitro painting, consisting angle cleats of size 25mm wide 1.6mm thick with flange fixed to RCC/CGI roofing with dash fastener or wraping the suspending wire around the existing wooden/steel purlin/rafter for suspending grid frame work of size 605mmx605mm suspended with 02 Nos, 1.60mm dia GI wire @ 600mm C/C on main Tee and fixed to T-grid with the help of level clip or as per manufacturer direction. The section consisting of main Tee 36.5 mm x25mmx1.40mm thick, cross runner tee 23.5mm x26.5 mmx1.4 mm and perimeter angle 40mmx 25mmx2.0 mm thick shall be fixed to wall with GI screw of 40mm long @ 450mm C/C along the perimeter of wall all as per manufacturer's instruction and including taking down existing boards complete all as specified and directed.
Complete removal of existing treatment from old metal sheet by removing mildew, dirt and any loose tits of old paints on roof surface of any height and apply two coat of synthetic enamel paint by mechanical means of machine spray complete all as per manufacturer instruction complete all as specified and directed.
Complete removing of existing treatment from wall / ceilling complete all as specified and directed. (work to be carried upto a height of 7.50m high)
Preparation of scrapped/ new plaster surface of wall / ceiling and applying 2mm thick Asian acrylic damp proof wall care putty as per manufacturer instruction complete all as specified and directed. (work to be carried upto a height of 7.5m).
Preparation of puttyied surfaces of wall/ceiling and applying one coat of primer complete all as specified and directed.(work to be carried upto a height of 7.5m).
Preparation of primed surfaces of wall / ceiling and applying two coats of Apex paint ( Weather coat exterior paint) complete all as specified and directed. (work to be carried upto a height of 7.5m) .
Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and removing material from site for offring schedule of credit except fans etc which shall be re-used in work and making good the disturbed surfaces in CM 1:3 of walls, floors, ceiling etc including distempering to match with existing surfaces complete all as specified and directed.
Supply and laying or fixing or passing through pipe XLPE insulated, armoured, heavy duty electric cables 1100 volts grade with stranded aluminum conductor of size 25 sqmm 3.5 core laid in trench/wall/floor/trusses with including taking down existing cable saddle complete all as specified and directed.
Point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLS having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area drawn in and including concealed non metallic rigid PVC conduit 25mm dia or higher with all fitting and fixing accessories and 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes 1.6mm thick, 60mm deep of required size factory made for mounting switch, regulators etc with and including 3mm thick plastic hylam laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches, sockets etc complete for the following:- Note:- (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Point wiring & earth wire shall be connected to each & every sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
One light/fan point /exhaust fan point controlled by one switch, one way switch 5/6 Amp
One3 pin/ 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch.
One 3 pin/5 pin switch socket outlet, 5 Amps on independent board.
Description all as per item No 76 here in before but point wiring with 2.5 sqmm multistrand copper conductor cable for one 5 pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm PVC insulated multi strand copper conductor cable as continous earth wire.
Switch piano, flush type, single pole one way, 5 Amp complete all as specified and directed.
Switch piano, flush type, single pole one way,15 Amp complete all as specified and directed.
Socket outlet multipurpose, 2 in 1 , 5 pin ,5 Amp flush type complete all as specified and directed.
Socket outlet multipurpose, 2 in 1 , 5 pin ,15 Amp flush type complete all as specified and directed..
Ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate /isolated body complete all as specified and directed.
Lamp holder angle type PVC/ polycarbonate body with cold grip cap suitable for pendent fitting complete all as specified and directed.
Electronic step rotary type fan regulator 100 W 230 Volts AC 50 HZ complete all as specified and directed.
Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 6.0 Sqmm size with multi stranded copper conductor drawing into and including PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 6 Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down old unserviceable submain wiring complete all as directed. Make of wire : Finolex, Plaza, Havells, Polycab NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
MCB SPN 40 to 63 Amps, 240 volts ,50 HZ, including connection with suitable size copper lugs complete all as specified and directed. Make:- Legrand, cat part no 408618 to408620 or L&T, ABB, Schneider, C&S
MCB SP 6 to 32 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as specified and directed. Make:- Legrand, cat part no 408587 to408595 or L&T, ABB, Schneider, C&S
Surface and wall mounted LED batten extruded aluminium housing provided for efficient heat dissipation with poly carbonate diffuser and integrated elctronic driver with and including 20 W LED tube rod complete and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls including taking down existing fitting complete all as directed. Make: Havells Cat part No. ENDURALINEAR NEO BS 20WLED 865SPCWH or equivalent to Philips/Wipro.
25Watt LED cool white, energy saving IP66, environment friendly, long life, LED street light made up of pressure die-cast aluminium housing with high power LEDs as lighting source and lens embedded PC cover having top opening seperate driver compartment suitable for pole dia 43mm (max) including suitable size of bracket bent in shape including 2 Nos clamps, nut, bolts etc and fixing on walls complete including taking down existing light fitting etc complete all as specified and directed. Make:- Havells cat part No ENDURAPEARLSL25WLED 757 SASYTOPCMP or equivellent to Philips/Surya
Aesthetically designed 42W LED840 S 2 x 2 , cool white flat panel surface /ceiling mounting which provide soft light and glare free symmetricsl illumination to fisture size (595 x 595 x 70 ) mm with and including 42W LED complete and connected the same with using PVC sheathed and insulated t three core flexible23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls complete all as specified and directed. Make:- Havells cat part nosVENSMEOHE2X2PLR42WED857MOD or equivellent /Philips/Syska/C&S.
Supply and laying or fixing or passing through pipe XLPE insulated, armoured, heavy duty electric cables 1100 volts grade with stranded aluminum conductor of size 10 sqmm 2 core laid in trenches /duct /wall /floor etc complete all as specified and directed. Make: Finolex/Havells/Polycab/Gloster/plaza
Supply and laying or fixing or passing through pipe XLPE insulated, armoured, heavy duty electric cables 1100 volts grade with stranded aluminum conductor of size 06 sqmm 2 core laid in trenches /duct /wall /floor etc complete all as specified and directed.
Un-reinforced precast concrete cable cover class LV type1 flat size250 mmx 150 mm x40 mm as protection to under ground cable laid dry flat adjjoining each other complete all as specified and directed
Supply and filling sand with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. NOTE: - Punned thickness shall be measurement & paid.
GI pipe light grade ISI marked 40mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah with calmps, bolts, nuts & washers etc complete all as specified and directed.
GI pipe light grade ISI marked 50mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah with calmps, bolts, nuts & washers etc complete all as specified and directed.
LED flood light fitting 50 watt energy saving and enviromental friendly long liife exclusive innovative made up of pressure die cast aluminium housing with high power LED as lightning source, suitable for high lighting archtectural features or area lighting also suitable for rough services/installations, etc complete including taking down existing fitting any type and in any position complete all as directed. Make: Havells cat part No. JETAQUANTOFLS50W LED765SYMPC or equivalent in Philips / Wipro.
Pole mounted LT junction box, waterproof and fire proof, sheet moulding compound (SMC) Sintex Make box of inside size 250mm x200mmx100mm deep complete with 4 Nos terminal end, aluminum strip of 20x4 mm size fixing cable end terminal and 3 Nos MS bolts and nut of size 8 mm dia x 30 mm long and MCB mounting rail with 6 amp MCB SP welded with box fixed on pole with MS clamp 25 mm x 3 mm MS strip duly painted and testing including taking down existing complete all as specified and directed.
Bus bar chamber pedestal type of size 75cmx60cm x40cm, out door, dust & vermin proof, front opening made out of 2.00 mm thick MS sheet duly painted and consisting of aluminium bus bar 3 phase and neutral 4 Nos 400 Amp fixed on insulators and one MCCB TPN 200 Amp, 25 KA breaking capacity including fixed in PCC 1:3:6 including danger plate etc including taking down existing LT feeder pillar with MCCB complete all as directed.
Supplying, laying, jointing and testing PVC insulated, multi core stranded copper conductor cable, 1100 volts grade, cross-sectional area 1.5 Sqmm 3 core complete including disconnecting & taking out existing cable etc complete all as specified and directed.
Post top lantern fully cast aluminium body finished with polyurethane paint (with prior treatment) with acrylic window cover with B 22 holder, LED lamp 12 watt and spigot dia 62 mm including taking down existing fitting any type and any position complete as all as directed. Make- Mepro electricals Cat part No PTL -08 or equivalent in Bajaj and Crompton Greaves
LED strip sky cave 5mm WW with driver 24 watt output 3000K including taking down existing fitting any type and any position complete all as specified and directed.
Earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.
Earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to GI earth strip 25mm X 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.
MCB DB, sheet metal enclosures double door SPN 8 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (METAL DOOR) type with blanking plates where required and IP 43 degree protection fixed in repair complete all as specified and directed.
M/S S P BUILDERS
M/S RAJESH KUMAR GOYAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .