Xen RnB Division Kargil
Construction of Modern Public Sanitation Block at CHC Drass (Under SDP) Balance work
2026_PWD_18425_1
E tender 133 of 2025-26 PW RnB Division 2nd Kargil
Open Tender
Civil Works - Buildings
Percentage
30 days
Kargil
Please refer Tender documents.
2 documents required · 2 mandatory
₹100
Xen RnB Division Kargil
₹24,700
12 Feb 2026
31 Jan 2026
7 Feb 2026
31 Jan 2026
6 Feb 2026
31 Jan 2026
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete :
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Second class kail wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). Second kail wood
12mm Cement plaster on the rough side of single or half brick wall of mix:1 : 4 ( 1 cement : 4 coarse sand)
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. (Note: It Should have Low or No VOC as per Green Building guidelines
New work (Two or more coats applied @ 1.43 litre/10 sqm. Over & including priming coat of exterior primer applied @ 0.90 litre/10 sqm. (Note: It Should have Low or No VOC as per Green Building guidelines)
Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) (Note: It Should have Low or No VOC as per Green Building guidelines)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. (Note: It Should have Low or No VOC as per Green Building guidelines)
Providing hoisting and fixing trusses/purlins/rafters/posts/post plates or like components of 1st class budloo/fir wood including cost of screws etc complete.
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
3.5 mm thick Glass pans in windows and vents
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and
Supply and installation of 15 liter Gyser in bathrooms
Supply installation testing and commissioning of Exaust Fan of approved brand (Havells/Bajaj/Crompton or any othet approved brand as per engineer in charge including all fixtures all complete
Providing and fixing soil waste & vent pipe (Prince or any other appoved brand as per Engineer In Charge
110mm dia PVC
75mm dia PVC
PVC Bend 110mm dia
PVC Bend 75mm dia
PVC Tee 110mm dia
PVC Tee 75mm dia
PVC Collar 110mm dia
PVC Collar 75mm dia
PVC trap 110mm dia
PVC trap 75mm dia
Providing and fixing wash basin with C.I./M.S. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps JAGUAR / CERA/HINDWARE Make
15 mm C.P. brass 2 in 1 tap of approved quality conforming to IS standards
P/F of mirrors of superior glass with plastic moulded frame(of approved quality) and of required size and shape. With 6mm thick hard board backing. Rectangular Shape 1500 x 450 mm
SEPTIC TANK
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earthlead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge
In All Kind Of Soil 90%
Ordianary rock 10%
Stone soling including carriage and cost of stone
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete :with 1:3:6 mix .
Dry random rubble masonry with hard stone in foundation and plinth:
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level
Centering and shuttering including strutting, propping etc. and removal of form for:
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc complete 25mm thick with 12.5 mm nominal size stone aggregate.
12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)
Disposal of Malba 5 Km MT
ELECTRIC WORKS
Sub Head-1
Internal Electrification
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in Existing surface/recessed medium class PVC conduit ,with modular switch,modular plate,suitable GI Box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required. (Group: A (Make: Havells life line,life /Polycab FRLS/KEI)
Wiring for circuit/sub mains wiring along with earth wire of the following size of FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit as required.
2x2.5 sq.mm
2x4 sq.mm
Sub Head-2
Supply, installation,Testing & commissioning of Internal lighting fixtures
Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted.
10 W LED Down light
50W LED Flood light ip 65 Protection
Sub Head-3
Supply installation of E Fan,C Fan,W Fan
P/F of exhaust fan shutter type of sweep 250mm in the existing opening, including making the hole to suit the above fan, making good the damage as required. (Make: Havells USHA/Bajaj)
Sub Head-4
Gi Box along with modular base & Cover plates
S/F following size/module, GI box along with modular base and cover plate for modular switches/sockets in recess etc. as required: (Make: Havells Crabtree/Legrand/Greatwhite/Gold medel)
3 module (100mm x 75mm)
4 module (125mm x 75mm)
6 module (150mm x 125mm)
Sub Head-5
Modular Switches/Sockets
S/F following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required. (Make: Havells Crabtree/Legrand/Greatwhite/Gold Medel
6 amp switch
16 amp switch.
3 pin, 6 amp socket outlet
6 pin, 16 amp socket outlet
Blank
Sub Head-6
MCCB & MCB Distribution Board
MCB Distribution Board: S/F Double door MCB distribution boards, 240V/415V, Sheet steel, Powder coated DB’s suitable for MCB’s fitted with Bus Bar, Neutral link, Earth Bar and Din bar of following no. of ways :: (Make: Havells/C&S/L&T)
12 Way double door SP&N
Sub Head-7
Miniature Circuit Breaker/RCCB Residual Current Circuit Breaker/Double Pole Miniature Circuit Breaker
S/F of 5 Amps to 63 Amps, 240/415V, “B series, ISI Mark” miniature circuit breakers suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required: (Make: Havells/C&S/V Guard)
Single pole 6A, SP MCB
Single pole 16A, MCB
Double pole 40A, DP MCB
Double pole 63A, DP MCB
Sub Head-8
Supply & Laying of Un-Armoured Cable & End Termination
Supplying and laying following size and specification of XLPE insulated PVC sheathed armored cable with aluminum conductor for working voltage 1100 V grade as per IS: 7908, including thimble/lugs, double compression glands etc.of respective size. (Make: Havells/Polycab/KEI)
2 Cx 16 Sq.mm Un-Armored Al. cable
Sub Head-9
Electrical Heavy PVC Conduit Pipe
Supplying and fixing of following sizes of medium class PVC cannel along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Channel langth 6 ft Breadth 1 inchi
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.39 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
BOQ_44316.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .