Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹2.8 L+₹5,398 (1.96%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹2.9 L+₹18,705.50 (6.78%)Accepted-Finance | L3 | Accepted-Finance L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/s Charley Enterprises L1 | arshcontractor L2 | munfad electricals L3 |
|---|---|---|---|---|---|---|
| 1.00Carriage of the following material from Store Centre, Rampur to work site including loading & unloading. | ||||||
| 1.01 | 11/0.4 KV 250 KVA Transformer | 1 | Nos | 1,500 ₹1,500 Lowest | 1,550 ₹1,550 | 3,000 ₹3,000 |
| 1.02 | PCC Pole 9 Mtr | 5 | Nos | 700 ₹3,500 | 710 ₹3,550 | 550 ₹2,750 Lowest |
| 1.03 | STP Pole 11 Mtr | 4 | Nos | 750 ₹3,000 | 760 ₹3,040 | 500 ₹2,000 Lowest |
| 1.04 | STP Pole 13 Mtr | 4 | Nos | 800 ₹3,200 | 880 ₹3,520 | 610 ₹2,440 Lowest |
| 1.05 | MS Chennel Top | 6 | Nos | 50 ₹300 | 55 ₹330 | 15 ₹90 Lowest |
| 1.06 | MS Channel Dropper | 6 | Nos | 50 ₹300 | 55 ₹330 | 15 ₹90 Lowest |
| 1.07 | MS Angle 65*65*2028 mm for bassing with 4 Clamp | 5 | Set | 50 ₹250 | 55 ₹275 | 16 ₹80 Lowest |
| 1.08 | 33 KV X-arms | 5 | Nos | 60 ₹300 | 65 ₹325 | 50 ₹250 Lowest |
| 1.09 | ACSR Dog Conductor | 380 | Mtrs | 10 ₹3,800 | 11 ₹4,180 | 3 ₹1,140 Lowest |
Tender Value
₹6 L
EMD Value
₹6,000
Closing Date
4 Nov 2024, 11:00 amClosed
SE EDC RAMPUR
office of the SE EDC RAMPUR
35/2024-25/EDCR Increasing of Load Capacity(112 KVA to 190 KVA) Railway Colony Rampur under DRM Moradabad and Shifting of 33 KV Line of 33/11 KV Phari Gate S/s for Consutruction CMO/Critical Care Center Phari Gate under Deposit works under Jurisdic
2024_PVVNL_966901_1
35/2024-25 (EDCR)
Open Tender
Electrical Works
Lump-sum
45 days
office of the SE EDC RAMPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
SE EDC RAMPUR
₹6,000
28 Oct 2025
19 Oct 2024
4 Nov 2024
19 Oct 2024
4 Nov 2024
19 Oct 2024
Amount
Carriage of the following material from Store Centre, Rampur to work site including loading & unloading.
11/0.4 KV 250 KVA Transformer
PCC Pole 9 Mtr
STP Pole 11 Mtr
STP Pole 13 Mtr
MS Chennel Top
MS Channel Dropper
MS Angle 65*65*2028 mm for bassing with 4 Clamp
33 KV X-arms
ACSR Dog Conductor
11 KV XLPE Cable 3*70 sqmm
33 KV XLPE Cable 3*300 Sqmm (Double Ckt)
LT Cable 3.5*240 Sqmm
I/D and O/D Cable jointing Kit suitable for 11 KV XLPE Cable 3*70 sqmm
33 KV Cable jointing Kit 3*300
3 PH-4W Static TVM 11 KV
11 KV Metering Cubical 15/5A
11 KV T-off channel
Stay wire for Cable support 8SWG
GM Connector 300 Amp 650 volts
Earthing Complete
Stay complete
33 KV Pin Insulator with Pin
33 KV Disc with fitting
11 KV Pin Insulator with Pin
11 KV Disc with fitting
old and used 160 KVA Transformer (Received back site to Store)
old and used ST Pole off size (Received back site to Store)
old and used ACSR Dog Conductor (Received back site to Store)
old and used MS Metable Scrap (Received back site to Store)
a) Single pole structure Excavation of foundation pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole)Erection of support(pole) complete with providing and fixing of all clamps made of MS flat of size 75x8 mm. an other accessories . The work includes fabrication work and fixing of cross bracing sets 3.5 Mtr from MS Angle 65x65x6 mm/50x50x6 mm. The work includes cutting holes and providing MS Bolts of 16x40 mm size in the middle of the cross bracing with 1 No. sparing washer of proper size.
PCC Pole 9 Mtr Long
Grouting of support in CC 1:4:8(cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level, 30 cm plinth above the ground level with CC 1:3:6 (cement, course sand and stone grit) with muffing. The work includes back filling and proper ramming etc.
PCC Pole 9 Mtr Long
a) Double pole structure Excavation of foundation pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole)Erection of support(pole) complete with providing and fixing of all clamps made of MS flat of size 75x8 mm. an other accessories . The work includes fabrication work and fixing of cross bracing sets 3.5 Mtr from MS Angle 65x65x6 mm/50x50x6 mm. The work includes cutting holes and providing MS Bolts of 16x40 mm size in the middle of the cross bracing with 1 No. sparing washer of proper size.
STP Pole 11 MTR Long
Grouting of support in CC 1:4:8(cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level, 30 cm plinth above the ground level with CC 1:3:6 (cement, course sand and stone grit) with muffing. The work includes back filling and proper ramming etc. a) Double support
STP Pole 11 MTR Long
a) Four pole structure Excavation of foundation pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole)Erection of support(pole) complete with providing and fixing of all clamps made of MS flat of size 75x8 mm. an other accessories . The work includes fabrication work and fixing of cross bracing sets 3.5 Mtr from MS Angle 65x65x6 mm/50x50x6 mm. The work includes cutting holes and providing MS Bolts of 16x40 mm size in the middle of the cross bracing with 1 No. sparing washer of proper size.
STP Pole 13 MTR Long
Grouting of support in CC 1:4:8(cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level, 30 cm plinth above the ground level with CC 1:3:6 (cement, course sand and stone grit) with muffing. The work includes back filling and proper ramming etc. a) Double support
STP Pole 13 MTR Long
Grouting of Stay Rods(20x1800)mm including all work of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:8(cement, sand, 40mm brick ballast) including back filling of soil and proper ramming etc.
Fixing, tightening and nozelling of stay wire with stay rod with the pole of required tension by providing stay clamps.
Earthing of support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 M apart from support and 0.5 M below the ground level and connecting below the earth electrodes with the help of GI wire No. 8SWG and earthing lugs.
fixing of 33 KV Pin Insulator with Pin as per RESPO Norms and as per direction of Supervising Engineer.
fixing of 33 KV Disc Insulator with Fitting as per RESPO Norms and as per direction of Supervising Engineer.
fixing of 11 KV Pin Insulator with Pin as per RESPO Norms and as per direction of Supervising Engineer.
fixing of 11 KV Disc Insulator with Fitting as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of ACSR Dog Conductor per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of 11 KV XLPE Cable 3*70 sqmm with the help of cable jointing kit per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of 33 KV XLPE Cable 3*300 sqmm(Double Ckt) with the help of cable jointing kit per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of LT Cable 3.5*240 sqmm per RESPO Norms and as per direction of Supervising Engineer.
Dismentalling of old and used ACSR Dog Conductor from site as per direction of Supervising Engineer.
Dismentalling of old and used ST Pole offf size from site as per direction of Supervising Engineer.
Dismentalling of old and used 160 KVA Transformer from site as per direction of Supervising Engineer.
Mounting and Installing of 250 KVA Transformer with proper connection at siet as per direction of Supervising Engineer.
Installing of 3-Ph-4w Sttic TVM 11 KVA as per direction of Supervising Engineer.
Installing of 11 KV Metering Cubical 15/5A as per direction of Supervising Engineer.
laying/gaurding from Stay wire for Cable support 8 SWG as per RESPO Norms and as per direction of Supervising Engineer.
fixing of GM Connector 300 Amp 650 Volts as per RESPO Norms and as per direction of Supervising Engineer.
Make plinth for 250 kVA Transformer as per Respo schedule as enclosed and as direction of Supervising Engineer.
Providing and fixing Fencing for 250 kVA Transformer as per Respo schedule as enclosed and as direction of Supervising Engineer.
Providing/fixing of of G.I. Pipe 6" Dia with nut and bolts as perRESPO Norms and as direction of Supervising Engineer.
filling and fixing of Cable Box as perRESPO Norms and as direction of Supervising Engineer.
Proper body and Neutral Earthing of Transformer as perRESPO Norms and as direction of Supervising Engineer(Material etc. provide by Contractor).
Providing/fixing of Clamp with Nut and Bolts as perRESPO Norms and as direction of Supervising Engineer.
Providing/fixing of Barbed wire as perRESPO Norms and as direction of Supervising Engineer.
Providing/fixing of Danger Board with Clamp as perRESPO Norms and as direction of Supervising Engineer.
Providing and fixing Stone Pad as per direction of Supervising Engineer.
Providing and fixing Cable Clamp as per direction of Supervising Engineer.
Providing and fixing Bolts and Nuts with Washers as per direction of Supervising Engineer.
Providing and fixing Clamp for Double Pole as per direction of Supervising Engineer.
Providing and fixing X-Arm holding clamp with nut and bolts as per direction of Supervising Engineer.
Providing and fixing AL Leg Long Barrel off size as per direction of Supervising Engineer.
arshcontractor
munfad electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .