Superintending Engineer, Project Implementation Unit, Health & Family Welfare Department
Upgradation of Exiting 3 Nos. Operation Theatre into Moduler Operation Theatre at SDH Dhoraji, Jetpur, Gondal Dist. Rajkot.
282866
151/06/2025-26
Open
Civil - All
Jamnagar
11 documents required · 9 mandatory · 2 optional
₹3,600
Yes
PIU – General Fund A/C 11-114
₹2.0 L
Yes
5 Mar 2026
5 Mar 2026
5 Mar 2026
12 Mar 2026
5 Mar 2026
Name of Work :- Upgradation of Exiting Operation Theatre into Moduler Operation Theatre At (ORTHO OT (NO-48)) SDH Dhoraji, Ta.Dhoraji, (MAJOR
OT (0-9)) SDH Jetpur, Ta.Jetpur & (General OT (No-36)) SDH Gondal, Ta.Gondal, Dist. Rajkot
RATE (With 1% L.C.)
SR NO. NBO NO. TOTAL QTY ITEM DESCRIPTION IN FIGURS UNIT AMOUNT
Supply, Installation, Testing and Commissioning of 50 mm thick Pre Fabricated Modular
Operation Theater Panels (Walls and Ceiling) made out Polyurethane foam injected at
Kg/m3 sandwiched between 0.8 mm thick GP and SP sheet on front side and 0.5 mm GP and
SP/PPGI sheet on back-side. The inner surface walls be fixed to the bricks wall with essential
support. There will be minimum possible cavity/gap in between solid and steel walls and will
be variable to suit the architects lay out for the flush mounting of the equipments. The wall
and ceiling panels must comply with necessary provision of to JIS Z 2801/ISO 22196, BS EN
Rupees Six Thousand Five
Hundred Fifty Only
A2. Any Third-party compliance certificate mandatory. Panel should be covered with
protective sheath of 300 d.f.t Anti-bacterial Paint having undergone Washability/Water
resistance Test JIS K 5663.7.12, permeability test less than 200 unit of permeability, Anti-
bacterial effect against staphyloccoccus aureus, Escherichia coli (via HALO test) and safety
and causative agents such as formaldehyde, toluene, xylene, paradichlorobenzene etc. Third
party (NABL approved Lab) certification for EGP and thickness test certificate to be
submitted at time of supply.
Supply, Installation, Testing and Commissioning of Ceiling Filtration System - The ceiling
filtration system in the surgical theatre should ensure a unidirectional distribution of sterile
air, covering all areas affected by the airflow. It should consist of a laminar flow system
incorporated within a frame made from thick extruded aluminum profiles, complete with a
sealed gasket to prevent leaks. The system should incorporate "H 14" class HEPA filters
positioned in the ceiling plenum. These filters should achieve an MPPS average efficiency
greater than 99.95% and a 3-micron DOP efficiency greater than 99.99%. The filters should
also be designed to handle a final pressure drop of no more than 600 Pa, operate at a
maximum temperature of 60 degrees Celsius, and function effectively within a relative Rupees Three Lac Ninety
humidity range of 40-50%. The filtration ceiling system should be capable of maintaining a Thousand Only
constant airflow velocity of 0.25 m/s at the diffuser. This should be accomplished through the
use of a diffuser or flow equalizer that ensures uniform and constant air distribution over the
entire surface area. The structure holding the filtration system, including the filter frames and
top plenum, should be made from either aluminum or stainless steel. The system should be
CE/UL certified and designed to achieve an ISO 14644/1 classification of ISO 5, with a
bacteriological class of B (5 CFU/m3) and particle decontamination kinetics CP of 5 minutes.
After installation, the system's performance should be validated by a third-party government-
approved environmental lab to ensure compliance with specified standards. A positive
RATE (With 1% L.C.)
SR NO. NBO NO. TOTAL QTY ITEM DESCRIPTION IN FIGURS UNIT AMOUNT
The flooring within the surgical theatre should consist of a minimum of 2mm thick antistatic
seamless PVC, ensuring durability and safety. This floor should be smooth, non-slip, and
made from an impervious material with sufficient conductivity to dissipate static electricity
effectively, yet not so conductive as to risk electric shock to personnel. The PVC used should
be of very high quality, particularly designed for electrostatic charge dissipation, and should
not be less than 2 mm in thickness. The installation process should utilize continuous rolls,
and joints should be seamlessly welded using special PVC thermal welding units with welding
bars of the same color to ensure uniformity and prevent contamination. The sheets should be
highly durable, capable of resisting shocks, indentations, and scratches. The conductive Rupees Four Thousand Two
material should be uniformly impregnated within the PVC as grains to enhance its antistatic Hundred Fifty Only
properties. Additionally, the flooring should be inert to body fluids, chemicals, and
disinfectants, and remain unaffected by temperature variations typical within an operating
theatre. It should efficiently discharge electric charges up to 2 kV, and the electrical resistance
(point to ground) should be maintained within 2.5x10^4 to 5x10^6 ohms, ensuring no buildup
of electrical charge beyond 100 volts. Floor installation should be performed by skilled
workers from accredited agencies authorized by the PVC sheet supplier. The installation
should include a conductive copper grid beneath the PVC sheet, supported by liquid epoxy
compounds to create a uniform and level surface. Copper strips should be made visible by
The door to the surgical theatre should be a hermetically sealed, single sliding door measuring
2.1 meters in height and 1.5 meters in width. The door should be equipped with a controller
capable of being operated by elbow switches, foot switches, and a touchless sensor, providing
multiple, accessible control options. The track for the door should be made from stainless
steel or aluminum, with the running surface for the top rollers angled appropriately to
minimize resistance and facilitate smoother movement. The door leaf should be suspended
using high-quality hard plastic rollers with double bearings at the top. These rollers should run
under the stainless steel or aluminum track to ensure smooth and noiseless operation. The
opening and closing mechanisms of the door should be controlled by a microprocessor for Rupees Two Lac Ninety Five
precise electromechanical movement. The material of the door should be either SMS or HPL, Thousand Only
with a color that matches the interior design. The door should be designed to be strong yet
lightweight for ease of use. In case the automatic mechanism fails, the door should still be
able to open and close effortlessly manually. The handle of the door should be made from
stainless steel with a matte finish and equipped with a high-quality cylindrical or ESPg lock
for security. The door leaf should incorporate a high-quality synthetic rubber gasket with long
durability to ensure hermetic sealing and maintain a 99.99% air tightness at a minimum
pressure of 75Pa. The floor on either side of the door should be perfectly level, with a
maximum permissible difference of +1mm, to avoid any tripping hazards or unsealed gaps.
RATE (With 1% L.C.)
SR NO. NBO NO. TOTAL QTY ITEM DESCRIPTION IN FIGURS UNIT AMOUNT
Supply, Installation, Testing and Commissioning of Membrane-Type Operation Switch and
Communication Controller - The Operation Switch and Comms Controller should encompass
all necessary controls to ensure the proper operation and monitoring of equipment and
services in the operating room (OR). Positioned for optimal visibility in the surgeon's line of
sight and the OT staff, the wall-mounted membrane-buttons should be easily accessible to the
nurse for operation and assistance. In addition to hosting a digital clock and elapsed time
indicator, the panel should feature a medical gas alarm, clearly indicating high and low gas
pressures for each gas service, including vacuum, supported by an audible alarm. The
Operation Switch and Comms Controller should also provide an alarm mute option for fault Rupees One Lac Ninety Five
annunciation, with pressure sensors strategically located near isolation valves. Controls for Thousand Only
general lighting, including ON/OFF and dimming, organized in groups for uniform
illumination, should be present. Furthermore, the panel should facilitate control over operating
lights (major and satellite) and camera functions (on/off and intensity). A hands-free
telephone set with memory should be conveniently situated, and temperature and humidity
controls for the room, linked to the AHU (+/5%) using NO/NC or Chilled Water/Hot Water
Actuator Control Valve (whichever is applicable), should be adjustable from the Operation
Switch and Comms Controller. Real-time indicators, such as a digital room pressure indicator
and HEPA filter bank differential pressure indicator, are essential for monitoring and
In each operating theater, an operating list board should be installed. It should be made of
ceramic with magnetic properties and should be flush with the wall to maintain cleanliness
and ease of use. LED type flat panel X-ray viewing panels should be provided, complying
with relevant electrical safety codes, and mounted flush with the wall to prevent dust
accumulation and microbial growth. The body should be made of extruded aluminum, powder- Rupees Twenty Eight
coated with a bacteria-resistant and disinfectant-resistant finish. The diffuser on the front Thousand Five Hundred Only
panel should provide a uniformly lit screen, and dimming controls should be easily accessible.
Additionally, a proper spring-loaded film clip with rollers should be included to securely hold
and easily remove films without causing scratches.
Supply, Installation, Testing and Commissioning of Double-Bay Scrub Sink - The scrub
station should be compact, designed for use in the OT complex, and facilitate pre-procedural
scrubbing. It should be made from heavy gauge type 304 stainless steel with a minimum
thickness of 1.5mm and feature seamless welded construction polished to a satin finish. The
scrub sink should have a front access panel for easy maintenance of water control valves,
waste connections, stoppers, and strainers. Hands-free operation should be enabled through Rupees One Lac Twenty Six
infrared sensors with programmable adjustments. Thermostatic mixing valve control should Thousand Only
maintain constant water temperature and be located behind the access panel. Timing should be
adjustable to meet individual usage requirements, and units should have reduced anti-splash
fronts. An additional knee/foot-operated switch should also be provided for enhanced
RATE (With 1% L.C.)
SR NO. NBO NO. TOTAL QTY ITEM DESCRIPTION IN FIGURS UNIT AMOUNT
Supply, Installation, Testing and Commissioning of Storage Units - Storage units should be
constructed with same material, as wall and ceiling panels. The shelves, made of glass and,
should be removable for cleaning. The unit should be divided into two or more parts, each Rupees Eighty Five Thousand
with individual glass doors equipped with a high-quality locking system. The overall size of Only
the storage unit should
be approximately 200 cm (H) x 120 cm (W) x 35 cm (D).
Supply, Installation, Testing and Commissioning of Peripheral Lighting - To enhance the
operational environment of each operating theatre, peripheral lighting and clean room
luminaries should be installed, with a minimum of eight units per theatre. These lights should
offer an intensity of at least 500 Lux and be housed in highly specular anodized aluminum
with an optical antiglare system to minimize visual fatigue and glare. Each peripheral light
should measure 2' x 1'. The covers for these luminaries should be constructed from highly
resistant, disinfectant-proof laminated safety glass or acrylic, featuring a stylish, fine-grained
surface that complements the clean and sterile environment of the operating theatre. The body
of the luminaries should be made from sheet steel, perfectly powder-coated to resist Rupees Twelve Thousand
contamination and facilitate easy cleaning, and should be ready for connection either as Only
individual units or within a series circuit. This setup should include digital electronic control
gear utilizing multilamp technology to optimize energy efficiency and light output. The
installation of these luminaries should ensure that the recess frames are gas tight. Each fitting
should be flush with the ceiling and designed to be removable from either the top or bottom
for ease of maintenance. It is crucial that the light fittings are uniformly and aesthetically
distributed across the ceiling to provide consistent illumination throughout the OT, without
interfering with visibility during procedures such as green mode endoscopy. Furthermore, the
peripheral lighting system should conform to IP65 or IP54 international protection ratings,
RATE (With 1% L.C.)
SR NO. NBO NO. TOTAL QTY ITEM DESCRIPTION IN FIGURS UNIT AMOUNT
Supply, Installation, Testing and Commissioning of Electrical Wiring inside OT - Power
distribution within each Operating Theatre (OT) should be handled via distribution boards
located locally to each theatre using Fire Resistance Low Smoke Wiring, layed in PVC
conduits of reputed brand. The sub mains power to these panels should be provided by the
general electrical contractor, and all distribution services within the departments should run
from these panels. The power distribution unit should hold certifications such as EN, CE,
FDA, IEC, and BIS to ensure compliance with international safety and performance
standards. Each wall of the MOT should have a minimum of two hybrid switch sockets
(6/16A) on each wall, in compliance with IEC standards. Light fittings within the clinical Rupees Two Lac Ninety Nine
areas should be recessed LED types equipped with control gear and sealed in accordance with Thousand Only
the IP54 standard. This standard ensures that the fittings are protected against limited dust
ingress and water spray from all directions, suitable for clinical environments. All equipment
should be fully and permanently labeled to clearly identify and describe the function,
operation, and voltage of the apparatus concerned. Upon completion of the electrical
installation, tests should be carried out in accordance with the relevant sections of local wiring
regulations, with results duly recorded. Each OT should have a distribution board (DBs)
installed, with suitable wiring. A separate enclosure should house all high-voltage equipment
to ensure safety and isolation. The remote cabinet should contain operating lamp transformers,
Single-arm surgery/anesthesia pendant designed for Operating Theatres should feature a
compact, modular configuration to meet the precise requirements of hospitals, enabling
customization to suit specific operational needs of both Operating Theatres and Intensive Care
Units. It should be equipped with robust ceiling support capable of mounting a selection of
arms. The extension arm, pivotal for functionality, should allow horizontal movement with a
radius of 800-900mm and provide a level rotation ranging from 0 to 330/340 degrees, with
both the extension arm and terminal box designed to rotate together and independently for
maximum versatility. The pendant should support a net loading capacity of min. 100 kg,
accommodating a variety of medical instruments and devices securely. For medical and Rupees Two Lac Eighty Four
electrical services, it should offer configurations that include at least two oxygen outlets, two Thousand Only
vacuum outlets, one medical air, one medical air at 7 bar, and an optional nitrous oxide outlet
(In-scope of MGPS vendor) Additionally, there should be six main sockets, each capable of
supporting 5 to 15 amps, conforming to universal standards to facilitate the operation of
various medical and electronic devices. In terms of materials and construction, the pendant
should be crafted from high-strength aluminum alloy with a sealed design to enhance
durability and maintain sterile conditions. The arm itself should be made from high-density
aluminum alloy extrusion, ensuring both strength and reliability. Installation of the pendant
should be ceiling-mounted to provide a reliable and firm setup, optimizing space usage in the
Medical Gas Pipe Line Of Required dia for OT oxygen , Vaccum , Air.. Etc reuired
Point(from existing line ) as directed by engineer incharge from Outer Nearest Passage to OT Rupees Three Lac Forty Five
Pendant Rate Including , Alarm , Valve (for all line) , Point ,Flowmeter and Probe . if alredy Thousand Only
then no payment given
RATE (With 1% L.C.)
SR NO. NBO NO. TOTAL QTY ITEM DESCRIPTION IN FIGURS UNIT AMOUNT
AIR HENDALING UNIT Make:KrVelocity: Not More Then 10 mt/second. , Canvass
Connection-Heavy duty, non partical shreding,Fire Retardentuger,Nikotra only , Type:
PLUG,Drirect Driven,Dynamically Balanced Selection of fan-Should run comfortably at
HZ at rated capecity. Motor Make:Siemence,B.B,Crompton,ABB , Type:TEFC, IP:55, Foot
Mounted, VFD compitable and I2 generation Safety: Motor should have interlocked with
AHU Motor door/excess/Fire DamperType-TWO TIRE, Floor Mounted , Inner const.:0.6mm
plain G.I , Outer const.:0.8 mm G.I. Pre coated / Powder coated Thickness of Insulation: Rupees Twelve Lac Thirty
13 14.00 3.00 1237250.00 Seven Thousand Two Hundred Cmt
25mm,PUF injected having density 40 to 42 kg/m3. ,Colour:As approved by CLIENT Fifty Only
CONDENSING UNIT :
Condensing unit for AHU with all assesories and instalation (Copper pipie provide 3 mtr
Only Extra will charged extra) consider 1200 sqfeet insulation and ducting
Double Dome OT Light with Ceiling mounted Double Dome LED OT lights having following
features and enclosed technical specifications, having Mobile App Connectivity, Battery
-Light intensity Ec - 160 000 & 160 000 lux, - Light intensity adjustment - 10 – 100% (using
Digital Capacitive Touch (Fully Remote Controlled) - Color temperature Tc (with adjustment)
-3800 – 4800 K -Light field diameter d10 at Ec - 100 - 150 mm -Working range - 1 m -Color
Rupees Three Lac Ninety Three
14 14.00 3.00 rendering index 93Ra - Focusing Preset: Adjustable - LED Average life - 50000-60000 hrs - 393900.00 Cmt
Thousand Nine Hundred Only
Diameter of Light - not less than 650 mm per dome - Power Consumption - not more than
120W OT Light should be BIS marked; manufacturer should have CDSCO License for this
product under Class A, Compliant to IEC standards such as IEC60601-1:2005+A2:2020, IEC
60601-2-41:201 (Relevant Test Certificates to be submitted with Bid) Clause-wise Technical
Compliance to be
Hatch boxes should be provided in each operating theater to facilitate the safe and efficient
removal of waste materials to the dirty linen area or adjacent corridor. Each hatch box should
be equipped with two doors, operated electrically or motorized, designed such that only one
door can be opened at a time to prevent cross-contamination. UV lighting should be installed Rupees One Lac Sixteen
15 7.00 3.00 to ensure sterilization and should remain on when both doors are closed, automatically turning 116150.00 Thousand One Hundred Fifty Cmt
off when either door is opened. Indicators should be provided on both sides of the operating Only
theater to monitor the door open/close status. The material of the hatch box should also be
SS304 grade stainless steel, with a minimum size of 600mm x 600mm.
Providing and fixing UPS (25KVA) Of Good Quality as directed by engineer incharge Rupees Three Lac Seventy Five
RATE (With 1% L.C.)
SR NO. NBO NO. TOTAL QTY ITEM DESCRIPTION IN FIGURS UNIT AMOUNT
LED type flat panel X-ray viewing panel should be supplied. This should comply with
relevant electrical safely codes. This should be a 2-panel viewing screen. Mounting should be
flush with the wall to avoid dust accumulation and growth or organisms between wall and
panel. Body should be of extruded aluminium powder coated black with bacteria resistant and Rupees Forty One Thousand
disinfectant resistant finish. The diffuser on the front panel should be a uniformly lit screen. Five Hundred Only
Dimming electronic control should be enclosed at the bottom of the cabinet. Proper spring-
loaded film clip with rollers should be provided to hold the films firmly and to remove the
film without scratches
Providing and erecting Approved make Four pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. and above at 415 V . having normal current rating 250A.
with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all Rupees Twenty Thousand
18 3-4-4. 3.00 20946.39 Nine Hundred Forty Six and Cmt
internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. Thirty Nine Paise
housing. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having
breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A.
with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all Rupees Six Thousand One
19 3-4-1. 9.00 6173.12 Hundred Seventy Three and Cmt
internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. Twelve Paise
housing. ICS=100% of ICU only Cat III
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars
with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm
(Rated current / cross section area) duly wrapped with colour insulating tape for phase Rupees One Thousand Nine
20 3-8-2. 3.60 sequence of following current carrying capacity, erected with necessary bus bar supports 1961.42 Hundred Sixty One and Forty Cmt
/insulators, main cable socket to each bar, erected in existing cubical panel with necessary Two Paise
connections.(A) Suitable for 100 Amp. Capacity
(B) Suitable for 200 Amp. Capacity Rupees Three Thousand Two
21 3-8-2. 3.00 3202.71 Hundred Two and Seventy One Cmt
RATE (With 1% L.C.)
SR NO. NBO NO. TOTAL QTY ITEM DESCRIPTION IN FIGURS UNIT AMOUNT
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated
indoor type cubical panel board necessary IP-42 and above protection as per approval from
engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors,
SWG thick CRC M.S.sheet for internal partitions with necessary accesories , supporting
angles/ flats channel including cutting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction of engineer-in-charge with erection
of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper wire /
copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring Rupees Ten Thousand Four
22 3-16-1 3.60 instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of 10468.65 Hundred Sixty Eight and Sixty Cmt
hinged doors, handles with locking arrangement and rubber gasket,heavy duty end terminal Five Paise
connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall
be painted with epoxy powder coating. (The rates excludes the cost of switchgears, bus bars,
inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall
be measured excluding base beams) The panel shall be supplied with following approved
manufacturers with following size.(A) locally fabricated panel board (i) with 350 mm depth
Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe
Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of
corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal
dia of 14 mm with constant ohmic value surrounded by highly conductive compound with
high charge dissipation suitable for following type of applications with chamber and heavy
duty cover (A)(approved make OEM has to submit test certificate including value of earth
resistance of installation duly stamped and signed by agency and officer Incharge has to Rupees Five Thousand Eight
23 3-14-10 6.00 ensure the value of earthing resistane mentioned in test Certificate) & having back filling 5842.85 Hundred Forty Two and Eighty Cmt
compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as Five Paise
per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C)
Back fill Compound :- Earthing compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.[A] For electrical installation up to 440 V
Length of Pipe - 1 Mtr
Back filling compound - 1 Nos. of Bag of 15 Kgs.
Providing and erecting Annealed bare Copper wire 8 to 16 SWG. Rupees Seven Hundred Ninety
Four and Eighty Seven Paise
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe Rupees Two Hundred Twenty
of following size of cables (B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core) and Eighteen Paise
RATE (With 1% L.C.)
SR NO. NBO NO. TOTAL QTY ITEM DESCRIPTION IN FIGURS UNIT AMOUNT
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe Rupees Six Hundred Seventy
at road crossing or floor of following size of cables. (A) 4 core 10 Sq. mm Six and Seventy Paise
Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 digits Rupees One Thousand Two
27 9-2-2. 3.00 LED display, 0 to 750 AC Volts range erected on existing panel board with all connection, 1275.63 Hundred Seventy Five and Smt
wiring etc .with manufacturers calibration certificate. Sixty Three Paise
Supplying and erecting approved make panel mounting type Digital Ammeter having
digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to operate Rupees One Thousand Five
28 9-2-4. 3.00 1558.43 Hundred Fifty Eight and Forty Kg
on 500 Volt AC , erected on existing panel board with all connection, wiring etc .with Three Paise
manufacturers calibration certificate.
Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase AC Supply 500 V Rupees Three Hundred
on existing panel board with necessary connections. Seventeen and Fourteen Paise
Supplying and erecting approved make suitable panel indicator LED type lamp, lens cover, Rupees Forty Three and Forty
complete erected with necessary connections. Three Paise
Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA
Rupees Two Hundred Seventy
31 9-2-7. 9.00 burden erected in existing CRCA box duly secured with insulating materials connected to the
Four and Seventy Two Paise
In words Rupees Rupees Two Crore One Lacs Eighty Four Thousand Six Hundred Nine and Paisa Fourty Three Only
I / We am/are willing to carry out the work at __________________________________________________ % Above / Below
percent ( Should be written in figures and words ) of the Estimated rates mentioned above. Amount of my/our tender works
Estimated Amount put to tender Rs.
Add/Deduct ______________________% above/ below Rs.
In words Rupees
1 All works shall be carried out as per Public Work Department Handbook and other specification of Division or as directed.
2 All the columns in Schedules should be filled in ink and the total of the entries ink last column should be struck by the contractor under his signature
3 Rates quoted include clearance of site ( prior commencement of work and at its close ). In all respect and hold good for work under all condition, site, moisture, weather etc.
4 Serviceable material available ( if any ) after Demolishing / Dismentalling any item should be hand over to the concerned PIU Site Engineer In Charge as per instruction.
Signature of the contractor with Seal Signature of Contracting Authority with Seal
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01 SBD.pdf
02 BOQ.pdf
3 PQ for OT.pdf
3A. Specification.pdf
3B. GTS Ele..pdf
4 GTS Civil.pdf
5 Special Condition Schedule-C.pdf
6 6372 Make List HO 15.10.2025-1.pdf
7 Special Condition for Tender.pdf
8 ijaradar-ok.pdf
9 Standard Specification for Electrical Work-1.pdf
10 Labour Cess - GR - Page-01 (1).pdf
11 Labour Cess - GR - Page-02 (1).pdf
12 Labour Cess - GR - Page-03.pdf
Download all tender documents and submit your bid