Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57,200Admitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹60,234.50+₹3,034.50 (5.31%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance | |
| 3 | L3₹60,316+₹3,116 (5.45%)Admitted-Fee/PreQual/Technical/Finance | L3 | Admitted-Fee/PreQual/Technical/Finance | |
| 4 | L4₹63,865.44+₹6,665.44 (11.7%)Admitted-Fee/PreQual/Technical/Finance | L4 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | V N RAJENDRA KUMAR L3 | Ismail L4 | VINOD KUMAR P S L1 | MUHAMMED HANEEFA L2 |
|---|---|---|---|---|---|---|---|
| 1.00Supply and Work Charges | |||||||
| 1.00 | 100.98.233:Supply of PVC Pipe, 10kg/cm2, 50mm Dia. | 100 | metre | 66 ₹6,600 | 68.54 ₹6,854 | 70 ₹7,000 | 65 ₹6,500 Lowest |
| 1.00 | 15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road | 1 | sqm | 370 ₹370 | 389.1 ₹389.1 | 2,500 ₹2,500 | 367.5 ₹367.5 Lowest |
| 1.00 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. | 46 | cum | 562 ₹25,852 | 595 ₹27,370 | 550 ₹25,300 Lowest | 562.5 ₹25,875 |
| 1.00 | 100.9.5:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 50 mm nominal outside diameter pipes. | 100 | metre | 47 ₹4,700 Lowest | 49.8 ₹4,980 | 50 ₹5,000 | 47 ₹4,700 Lowest |
| 1.00 | 100.60.1.3.2:Providing 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. | 2 | no | 6,036 ₹12,072 | 6,783.21 ₹13,566.42 | 3,500 ₹7,000 Lowest | 6,037 ₹12,074 |
| 1.01 | 100.60.3.1.2:Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads, and excluding cost of materials etc., and as per the directions of the department officers. | 10 | metre | 150 ₹1,500 | 159.75 ₹1,597.5 | 20 ₹200 Lowest | 150 ₹1,500 |
| 1.01 | 100.60.12.4.1:Providing 15mm PVC Tap in the water meter assembly for 20mm connection, using 25mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. | 2 | no | 566 ₹1,132 | 599.01 ₹1,198.02 | 500 ₹1,000 Lowest | 566 ₹1,132 |
| 1.01 | 100.98.442:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Large Orifice Type S2, Size 20mm. | 1 | no | 1,493 ₹1,493 Lowest | 1,577.66 ₹1,577.66 | 2,000 ₹2,000 | 1,493 ₹1,493 Lowest |
| 1.01 | 100.60.11.2.1:Providing 20mm (3/4 inch) GM Check Valve in the water meter assembly for 20mm connection, using 25mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers. | 2 | no | 615 ₹1,230 | 692.22 ₹1,384.44 | 500 ₹1,000 Lowest | 615 ₹1,230 |
Tender Value
₹67,753
EMD Value
₹1,694
Closing Date
22 Sept 2026, 3:00 pmClosed
T.K. Jithesh, Executive Engineer
PH Division, Sulthan Bathery
DEPOSIT-(25-26)(Police) - WSS to Mananthavady, Edavaka and Nallornadu villages-Providing water connection to Upper Subordinate Police Quarters at Payode-Pipeline Work
2026_KWA_870174_1
WRD/KWA-CE(NR)/TR11/4873/2026
Open Tender
Civil Works - Water Works
Item Rate
Payode
Please refer Tender documents.
9 documents required · 9 mandatory
₹660
₹1,694
24 Sept 2026
15 Sept 2026
23 Sept 2026
15 Sept 2026
22 Sept 2026
15 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply and Work Charges | |||||
| 1.001 | 100.98.233:Supply of PVC Pipe, 10kg/cm2, 50mm Dia. | 100 | metre | - | - |
| 1.002 | 15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road | 1 | sqm | - | - |
| 1.003 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. | 46 | cum | - | - |
| 1.004 | 100.9.5:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 50 mm nominal outside diameter pipes. | 100 | metre | - | - |
| 1.005 | 100.60.1.3.2:Providing 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. | 2 | no | - | - |
| 1.006 | 100.60.3.1.2:Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads, and excluding cost of materials etc., and as per the directions of the department officers. | 10 | metre | - | - |
| 1.007 | 100.60.12.4.1:Providing 15mm PVC Tap in the water meter assembly for 20mm connection, using 25mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. | 2 | no | - | - |
| 1.008 | 100.98.442:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Large Orifice Type S2, Size 20mm. | 1 | no | - | - |
| 1.009 | 100.60.11.2.1:Providing 20mm (3/4 inch) GM Check Valve in the water meter assembly for 20mm connection, using 25mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers. | 2 | no | - | - |
stage.html
html • 0.02 MB
finance_1474338.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1474338.xls
BOQ • 0.31 MB
BIDDOC.pdf
Tender Documents • 0.88 MB
Epayment.pdf
Other Document • 0.23 MB
Affidavit.pdf
Other Document • 0.24 MB
Integritypact.pdf
Other Document • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .