Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.1 L+₹6,543 (0.41%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹16.3 L+₹28,856 (1.80%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹16.9 L+₹85,543 (5.33%)Rejected-Finance | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹34,000
Closing Date
21 Oct 2020, 6:00 pmClosed
Lt Bhamre Kiran S
Garrison Engineer (AF) No.1 Military Engineer Service Air Force Station No.1 Jamnagar 361 003
REPAIR/MAINTENANCE OF FLAME PROOF WIRING IN CERTAIN BLDGS OF TECH AREA AT AF STATION JAMNAGAR
2020_MES_380103_1
8755/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) JAMNAGAR NO.1
₹34,000
Yes
31 Oct 2020
23 Sept 2020
22 Oct 2020
23 Sept 2020
21 Oct 2020
7 Oct 2020
Amount
Taking down carefully aluminum flame proof point wiring complete of any type (surface ERW conduit for light point, fan point, or power point complete with all fitting such as rotary switches, sockets, fan regulators etc complete and making good disturbed surfaces complete all as specified and directed by Engg-in-Charge.
Taking down carefully Flame proof Hanger light fittings of any description from existing position from Hanger/Stores complete all as specified and directed by Engg-in-Charge.
Taking down old sub main wiring including rigid steel conduit with all accessories and removing to and making good disturbed surfaces complete all as specified and directed by Engg-in-Charge.
Material & Labour for point wiring for one light point controlled by one flameproof switch, complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen) cable 1100 volts grade ISI marked drawn and including mild steel ERW conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc complete all as specified and directed by Engg-in-Charge.
All as per item No 04 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke & Halogen, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
Supply and fix in repair Flame proof rotary switch ( Isolator ) rating 16 Amps. Single pole ON /OFF in aluminium alloy LM 6 Construction with one/ 2 nos, 3/4 " ET entries, certified by CMRS , Dhanbad for Group I, IIA, IIB, complete complete all as specified and directed by Engg-in-Charge. Make:- Sudhir Cat No RI/OA/1010-2A or equivalent of make mention in Appx B
Supply and fix in repair Flame proof switch socket combination rating 16 Amps, 250V , Single pole ON /OFF switch and 2P + Earth, Triangle type pins in aluminium alloy socket LM 6 Construction with Plug , certified by CMRS , Dhanbad for Group I, IIA, IIB, complete all as specified and directed by Engg-in-Charge. Make:- Sudhir Cat No SS/OA/1010-1 or equivalent of make mention in Appx B
Supply and fix in repair Flame proof fan regulators in aluminium alloy LM 6 Construction , certified by CMRS, Dhanbad for Group I, IIA, IIB, complete all as specified and directed by Engg-in-Charge. Make:- Sudhir Cat No RI/OA/1010 or equivalent of make mention in Appx B
Supply and fix in repair flame proof and weather proof industrial type DBs with various combination of incoming and outgoing MCB suitable for and including (a) 01 No MCB TPN 63 Amps, C type (incoming) (b) 06 Nos MCB SP 10 Amps C type (c) 2 Nos MCB SP 20 Amps C type including necessary connection complete all as specified and directed by Engg-in-Charge. Make:- Sudhir Cat No MCDB/186 or equivalent of make mention in Appx B
Supply and fix in repair flame proof and weather proof metal clad single pole and neutral with earth enclosure industrial plug and socket with suitable size of MCB SP 6 to 32 Amps C type, in aluminium alloy LM 6 Construction, certified by CMRS, Dhanbad for Group I, IIA, IIB, including necessary connection complete all as specified and directed by Engg-in-Charge.
Supply and fix in repair flame proof and weather proof metal clad triple pole and earth enclosure industrial plug and socket with suitable size of MCB tripple pole 32 Amps C, in aluminium alloy LM 6 Construction , certified by CMRS, Dhanbad for Group I, IIA, IIB, including necessary connection complete all as specified and directed by Engg-in-Charge.
Supply and fix in repair Flame proof Ceiling fan 1200 mm in aluminium alloy LM 6 Construction , certified by CMRS , Dhanbad for Group I, IIA, IIB, including taking down old fan and deposited in Store yard of AGE E&M complete all as specified and directed by Engg-in-Charge. Make:- Sudhir Cat No CF/193 or equivalent of make mention in Appx B
Supply and fix in repair flame proof exhaust fan of size 305 mm (12'') sweep 240 V 50 Hz , 1440 RPM single phase heavy duty complete with louver shutter and flame proof wire from ceiling rose to exhaust fan, including taking down old fan and deposited in Store yard of AGE E&M complete all as specified and directed by Engg-in-Charge. Make: Sudhir cat No EF / 140 or equivalent of make mention in Appx B
S&F in repair flame proof weather proof flood light fitting suitable for & including 90 watt LED chips, in cast aluminium alloy LM 79 construction, including driver, reflector, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed by Engg-in-Charge. Make:- Sudhir Cat No FL/2C/1251 or equivalent of make mention in Appx B
S&F in repair flame proof weather proof flood light fitting suitable for & including 70 watt LED chips, in cast aluminium alloy LM 79 construction, including driver, reflector, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed by Engg-in-Charge. Make:- Sudhir Cat No FL/2C/1251 or equivalent of make mention in Appx B
S&F in repair flame proof weather proof flood light fitting suitable for & including 45 watt LED chips, in cast aluminium alloy LM 79 construction, including driver, reflector, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed by Engg-in-Charge. Make:- Sudhir Cat No FL/A/150 or equivalent of make mention in Appx B
S&F in repair flameproof, weather proof LED tube light fitting, type FLP-WP with LED 1 x 16 / 20 W including integral reflector made of aluminium alloy LM79 , with electronic driver, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed by Engg-in-Charge. Make:- Crompton Cat No EXTN1LT8-16/20 or equivalent of make mention in Appx B
Supply and fix in repair flame proof well glass fitting suitable for & including 40 Watt LED chips with built in electronic driver in aluminium alloy LM 79 construction and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed by Engg-in-Charge. Make:- Crompton Cat No FWL1315-40-CDL/CG or equivalent of make mention in Appx B
Note For BOQ Item No 14 to 18:- 1. All Flameproof LED light procured by the contractor shall pre tested in accordance with LM 79 by manufacturers for individual Flameproof LED products, in their own laboratory accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL) or UL or third party laboratory accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL)........
.....Contractor shall submit documentary evidence obtained from manufacturer of LED light fitting that laboratory in which testing has been carried is accredited by National Accreditation Board for Testing and Calibration Laboratories (NABL) along with sample of LED fitting all as specified under relevant PS clause. 2. All fitting should be Mfg date After July 2017 and their guarantee letter also submit to Engineer in Charge
Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 1.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
S&F in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed by Engg-in-Charge.
Supply and fix MCB’s single pole, 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting complete all as specified and directed by Engg-in-Charge.
Supply and fix MCB’s single pole & neutral, 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting complete all as specified and directed by Engg-in-Charge.
Supply and fix MCB’s single pole & neutral, 40 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCB’s triple pole, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting complete all as specified and directed by Engg-in-Charge.
Supply and fix in repair weather proof & flame proof PVC knob suitable for flame proof DBs/Flame proof Switch rotary as per reqd at site and complete all as specified and directed by Engg-in-Charge.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground.......
.......connected to GI wire 4mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note:-Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length
Sukhi Electricals
SURESH ELECTRICALS
ambika electric co
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .