Loading…
Loading…
Tender Value
₹3.1 Cr
EMD Value
₹3.1 L
Closing Date
15 Jun 2026, 6:10 pm
Executive Engineer, Chhotaudepur (R & B) Division, Chhotaudepur
Construction of Veternary Polyclinic Building at Village Dhandhoda (Ground Floor) Ta. and Dist. Chhotaudepur
311076
07 of 2026-27
Open
Civil Works - Buildings
Chhotaudepur
2 documents required · 2 mandatory
₹6,000
Executive Engineer, Chhotaudepur (R&B) Division, Chhotaudepur
₹3.1 L
3 Jun 2026
3 Jun 2026
3 Jun 2026
15 Jun 2026
3 Jun 2026
Name of work :-
Construction of Veternity Polycleanic Building at Village Dhandhoda (Ground Floor) Ta. and Dist :-
Bill of Quantities
(A) Percentage Rate Tender (Up to INR 50 Cr. )
m Item of work Quantity Unit Amount
1 Excavation for foundation upto 1.50 mt depth including sorting out 929.00 Cumt 125.86
and stacking of useful materials and disposing the excavated stuff
all lead and lift. (A) Loose or soft soil.
2 Excavation for foundation 1.50 mt to 3.00 mt depth including sorting 149.10 Cumt 174.56
out and stacking of useful materials and disposing the excavated stuff
all lead and lift.(B) Dense or hard soil
3 Filling in foundation and plinth with sand in layers of 20 cm. Thickness 272.20 Cumt 489.28
including watering ramming and consolidating etc. comp. with all lead
4 Filling foundation and plinth with murrum or selected soil in layer of 20 425.70 Cumt 304.60
cm in thickness including ramming watering and consolidating etc.
complete with all lead and lift.
5 Filling available excavated Earth (Excluding Rock) in trench plinth side 609.00 Cumt 137.47
of foundation . in layer not excluding 20 cm in depth consolidation
each deposited layer by ramming and watering etc. complete
6 Applying general insecticide pest control treatment to floors, 961.30 Sqm 49.25
cupboards etc including labour materials etc. complete. Using
Imidacloprid 20 EC As Per 6113 pests Consentration Weight
percent is recommended on litre chemical emulsion dilute with 39 liter
of water will give. Total dilute concrentration with will be 40 litre
inclusive of one litre chemical emulsion application 0.5 litre chemical
/Sqm of surface is recommended as per I.S.
7 Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand 219.40 Cumt 3245.91
: 6- Crushed stone aggregates 40 mm nominal size) and curing
complete including cost of formwork in (A) Foundation and Plinth
8 Providing and laying controlled cement concrete M.250 and curing 252.10 Cumt 4882.34
complete including the cost of form work with Ply & Cuplock but
excluding the cost of reinforcement for reinforced concrete work in (A)
Foundations, footings and Mass concrete. Footing
9 Providing and laying controlled cement concrete M-250 and curing 48.90 Cumt 8301.19
complete including the cost of form work with Ply & Cuplock but
excluding the cost of reinforcement for reinforced concrete work in (d)
columns Up to Plinth level.
10 Providing and laying controlled cement concrete M-200 and curing 61.70 Cumt 8215.34
complete including the cost of form work with Ply & Cuplock but
excluding the cost of reinforcement for reinforced concrete work in
Columns, pillars posts and struts Ground Floor to First floor
11 Providing and laying controlled cement concrete M-250 and curing 122.70 Cumt 5979.20
complete including the cost of form work but with Ply & Cuplock
excluding the cost of reinforcement for reinforced concrete work in
Ground & Plinth BEAMS
12 Providing and laying controlled cement concrete M.150 and curing 132.20 Cumt 4282.40
complete including the cost of form work with Ply & Cuplock but
excluding the cost of reinforcement for reinforced concrete work in (C)
13 Providing and laying controlled cement concrete M.200 and curing 159.50 Cumt 6690.24
complete including the cost of form work with Ply & Cuplock but
excluding the cost of reinforcement for reinforced concrete work in (C)
Ground floor to First floor Slab
14 Providing and laying controlled cement concrete M.200 and curing 130.90 Cumt 6268.06
complete including the cost of form work with Ply & Cuplock but
excluding the cost of reinforcement for reinforced concrete work in (C)
Ground floor to First floor Beams
15 Providing and laying controlled cement concrete M-200 and curing etc. 19.20 Cumt 6062.02
complete including the cost of form work with Ply & Cuplock but
excluding the cost of reinforcement for reinforced concrete work in (c)
Chhajja for Ground floor to First floor
16 Providing and laying controlled cement concrete M-200 and curing etc. 4.80 Cumt 6428.65
complete including the cost of form work with Ply & Cuplock but
excluding the cost of reinforcement for reinforced concrete work in (c)
Lintel for Ground floor to First floor
17 Providing and laying controlled cement concrete M-200 and curing etc. 2.30 Cumt 7219.48
complete including the cost of form work with Ply & Cuplock but
excluding the cost of reinforcement for reinforced concrete work in (E)
Stair case up to floor two level for Ground floor to First floor
18 Providing and laying controlled cement concrete M-200 and curing etc. 0.30 Cumt 7269.97
complete including the cost of form work with Ply & Cuplock but
excluding the cost of reinforcement for reinforced concrete work in
RCC Vertical and horizontal wall for Ground floor to First floor
19 Providing and laying controlled cement concrete M-200 for RCC work 23.50 Cumt 6762.96
and curing complete including the cost of form work with Ply &
Cuplock but excluding the cost of reinforced concrete work in coping
on Ground Floor to First floor
20 Providing TMT Bar FE 500D reinforcement for R.C.C. work including 102274.00 Kg 77.37
bending, binding and placing in position complete up to All floor Level
21 Brick work using common burnt clay building bricks crushing strength 151.30 Cumt 4279.98
not less than 35 kg/sq.cm. in foundation and plinth in cement mortar
1:6 (1 cement : 6 fine sand) (B) Conventional For below plinth
22 Brick work using common burnt clay building bricks crushing strength 309.40 Cumt 4579.34
not less than 35 Kg/Sq.cm. in super structure above plinth level upto
floor two level in cement mortar 1:6 (1cement : 6 fine sand) (B)
Conventional For Ground Floor to First floor
23 Half brick masonry in common brunt clay building bricks having 318.00 Sqmt 696.90
crushing strength not less than 35Kg/Sm. In C.M 1:4( 1cement :
coarse sand) in super structure.(B) Conventional For Ground Floor to
24 Providing 15mm thick mala cement plaster in single coat on Rough 2650.20 Sqmt 179.78
(Similar)side of single or brick walls for interior plastering upto floor
two level and finished even and smooth in (ii) Cement mortar 1:4 (1-
cement :4-sand) including Mala troveled finish with 5mm Groves at
juction of structure member etc complete For .Ground Floor to First
25 Providing 10 mm. Thick Mala cement plaster in single coat for 1188.80 Sqmt 162.61
plastering on ceiling and soffits of stairs and finished even and
smooth in : (I) Cement mortar 1:4 (1 cement : 4 sand) including Mala
troveled finish with 5mm Groves at juction of structure member etc
complete For .Ground Floor to First floor
26 23 mm Thick sand faced cement plaster with Gutka Finish on walls 2017.20 Sqmt 353.98
upto height 10 meters above ground level consisting of 18 mm Thick
backing coat of c.m. 1:3 (1 cement : 3 sand) and 5 mm Thick finishing
coat of c.m. 1:1 (1 cement : 1 sand) with 10x5mm Groves at juction of
structure member etc. comp.etc. complete.
27 Providing and fixing 150 mm Wide approved quality chicken wire mesh 605.00 Sqmt 52.52
at junction of brick work and RCC work or two dissimilar surfaces, at all
heights fixed by nails, rowal plugs or tag by cement mortar 1:3 before
applying the plaster, including curing, scaffolding all complete as
28 Providing throating or plaster drip and moulding to R.C.C. Chhajja. 289.00 Rmt 44.07
29 Applying two coats of (white cement based) or (acrylic lappy (putty)) 3940.50 Sqmt 40.59
and two coats of primer of approved brand and manufacture on new
wall surface to give an even shade including thoroughly brushing the
surface free from mortar dropping and other foreign matter and sand
papered smooth.
30 Wall painting (Three coats) with plastic emulsion paint of approved 2751.70 Sqmt 128.38
brand and manufacture on undecorated wall surface to give an even
shade including one Coat water based Primer and throughly brushing
the surface free from mortar droppings and other foreign matter and
sand papered smooth.
31 Wall painting (Three coats) with plastic emulsion paint of approved 1188.80 Sqmt 134.04
brand and manufacture on undecorated ceiling surface to give an even
shade including including one Coat water based Primer and throughly
brushing the surface free from mortar droppings and other foreign
matter and sand papered smooth.
32 Providing One Coat of Alkali Resistant Primer on exterior wall surface 2017.20 Sqmt 40.40
of approved brand after thoroughly brushing surface to remove all
dust and remains of loose powdered material etc. copm. for all height
33 Wall Painting (Two coats) with weather proof acraylic emulsion paint 4031.20 Sqmt 122.14
of approved brand and manufacture and of required shade on exterior
wall surface to give an even shade over of approved brand after
thoroughly brushing surface to remove all dust and remains of loose
powdered material etc. copm. for all height
34 Providing and laying water proofing treatment by conventional 944.00 Sqmt 922.13
method including cleaning the slab surface by wire brush as directed
including provding first layer of C.M. 1:4 of 40 mm thickness mixed
with water proofing compound at rate prescribed by manufacturer,
including putting of brick bats of average thickness 40 mm Well
immerssed in water laid uniformly on first layer of mortar including
applying cement slurry @ rate of 0.08 bag/sqm. on fixed layer of brick
bats including maintaining necessary slope, in second layer 40 mm
thick C.M 1:4 mixed with water proofing compound as directed,
including finishing smooth with cement slurry as directed complete.
35 Providing and fixing window having extruded aluminum Colour 38.60 Sqmt 1821.03
anodized section Horizontal Three Track member size 95mmx
24.10mm x 1.17mm,@ Wt.0.738 Kg/mt and Vertical member of size
92mm x 31.75mm x 1.50mm @Wt. 1.06 Kg/mt, with Three Glass
shutters of horizontal member size 40mm x 18mm x 1.29mm (@ wt.of
0.456Kg/mt), vertical member of size 40mm x 18mm x 1.29mm (@
wt.of 0.456Kg/mt) with 5 mm thick Transparent Float glass with
powder coated aluminum fittings & fixtures and Lock Strip
transparent silicon sealant glass fixing to frame as per details etc
36 complete for window.
Providing and W1,W2
fixing window having extruded aluminum Colour 21.60 Sqmt 1966.47
anodized section Horizontal Two Track member size 95mmx 24.10mm
x 1.17mm,@ Wt.0.738 Kg/mt and Vertical member of size 92mm x
31.75mm x 1.50mm @Wt. 1.06 Kg/mt, with Two Glass shutters of
horizontal member size 40mm x 18mm x 1.29mm (@ wt.of
0.456Kg/mt), vertical member of size 40mm x 18mm x 1.29mm (@
wt.of 0.456Kg/mt) with 5 mm thick Transparent Float glass with
powder coated aluminum fittings & fixtures and Lock Strip
transparent silicon sealant glass fixing to frame as per details etc
complete for window. W3
37 Providing & Fixing in position standard extruded approved colour 4.40 Sqmt 2050.30
anodised Aluminum Ventilator with outer frame 65 x 25 mm Stander
Box Frame(of Jindal Section No.4605,@ Wt 1.094 kg/Rmt ) with 3mm
thick bajari Figured Glass fixed to alluminium strip blade fixed or
louvers adjestable ventilation including all required materials, fixtures,
fastenning, labours and equipments as per detailed drawing as
directed. For V1
38 Providing & Fixing in position standard extruded approved colour 8.10 Sqmt 1811.94
anodised Aluminum Ventilator with outer frame 65 x 25 mm Stander
Box Frame(of Jindal Section No.4605,@ Wt 1.094 kg/Rmt ) with Wire
Mesh Jali ventilation including all required materials, fixtures,
fastenning, labours and equipments as per detailed drawing as
directed. For V
39 Providing and fixing rolling shutters of approved make made of 80 mm 42.80 Sqmt 3554.40
wide M.S. laths 1.25mm thick inter-locked together through their
entire length and jointed together at the ends by end locks mounted
on specially designed pipe shaft with bracket plates, guide channels
and arragements for inside and outside locking with push-pull
operation including the cost of hood cover and spring etc. complete.
(B) Shutters having width below 3.5 Mt
40 Providing and fixing in position collapsible steel shutters with vertical 342.00 Kg 67.67
channel 20 x 10x 2 mm braced with flat iron diagonals 20 x 5 mm size
with top and bottom rails of T_rin 40 x 40 x 6 mm with 38 mm dia,steel
pulleys complete with bolts,nuts,locking arrangements,
stoppers,handles including applying priming coat with two coats of
enamel paints etc. Complete.
41 Providing and fixing M S angle openable Double Shutter grilled Door 723.00 Kg 105.04
having 65 MM. x 65 MM x 6 MM size M.S. angled welded togather to
make a box frame and 20mm dia M.S. bars to be fixed with it by
drilling hole in the angle section and welded at 10 cm C/C approx
including anodized iron fixtures & fastenings including primer coat of
approved quality and two coats of oil paint etc., complet as per detail
drawing as directed.
42 Providing and fixing Glass Door of 3.00 x 2.85m of Double shutter 9.00 Sqmt 4098.58
16mm toughen glass with Floor Spring and Pivot with fixed side panels
and Fixtures and Required Fitting material and labour etc. complete as
per the drawing, detail specification or instruction of engineer in
charge. Door shall be providing with Floor spring Heavy duty and 60cm
long stainless steel handle and necessary Locking system of Godrej, S.S
fixtures & fastenings etc. directed by engineer in charge D
43 Providing and fixing 38 mm thick flush door Double shutter, solid core 20.20 Sqmt 4270.28
with Flushed Door Having Decorative 1mm thick laminates on both
sides & 12 mm T.W.Beading Around the Door and stainless steel
handle, S.S. Aldrop ,S.S. Handle ,S.S. Stopper and necessary Locking
system or S.S hinges ,S.S fixtures & fastenings etc directed by engineer
in charge D1,D2
44 Providing and fixing 38 mm thick flush door Single shutter, solid core 42.00 Sqmt 3748.11
with Flushed Door Having Decorative 1mm thick laminates on both
sides & 12 mm T.W.Beading Around the Door and stainless steel
handle, S.S. Aldrop ,S.S. Handle ,S.S. Stopper and necessary Locking
system or S.S hinges ,S.S fixtures & fastenings etc directed by engineer
45 Providing and fixing 35 mm thick water proof flush door Single shutter, 14.10 Sqmt 2955.26
solid core with Flushed Door Having Decorative 1mm thick laminates
on both sides & 12 mm T.W.Beading Around the Door and stainless
steel handle, S.S. Aldrop ,S.S. Handle ,S.S. Stopper and necessary
Locking system or S.S hinges ,S.S fixtures & fastenings etc directed by
engineer in charge D4 & D5
46 Providing and fixing 90 cm & 105 cm high Stainless steel railing made 80.60 Sqmt 3886.48
from anticorrocive 304 grade S S pipe of 50 mm dia (16Gauge) as hand
rail with S S 304 grade Baluster of 38 mm dia (16Gauge) as a vertical
support fixed in RCC slab at 0.30m c/c including Four horizontal S S
pipes of 16 mm dia (16Gauge) at eqal distance fixed including The
Provisions in Nation Building Code 2016, part,Annex:B-6.2 with
baluster ,accesies as per detailed drawing as directed etc. complete.
47 Providing and fixing 316 grade S S hollow pipe Hand railing into 10cm 25.70 Kg 563.58
thick & 100cm Hight RCC wall @ on top 50 mm dia (16Gauge)
horizontal pipe and vertical support railing with all material , laboure
charges and accessories requirement as directed by Engineer-in-
charge etc. complete.
48 Providing and laying machine cut Mirror polished Granite stone 188.70 Sqmt 2188.67
18mm thick finished treads , risers and Skirting in full length with
Polished Edges & Anti Skid Groove with 1cm projecting, nozing in
tread laid over 20 mm (av.) thick bases of cement mortar 1:6 (1-
cement : 6-coarse sand) jointed with grey or colour cement slurry
including rubbing and polishing etc. complete
49 Providing and laying Soluble Salt Vitrified Tiles of 8 & 10mm thick, 60 x 314.30 Sqmt 1531.82
60 cm in flooring, treads of steps and landing laid on a bed of 20 mm
(average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on
new surface or fixing on existing flooring by adhesive material and
jointed with color cement slurry including finised with flush pointing &
cleaning the surface etc. complete for Colour and Shade approved by
Engineer-In-Charge
50 Providing and laying Soluble Salt Vitrified Tiles Tiles of 8 & 10mm thick, 27.70 Sqmt 1592.40
60 x 60 cm in Dado, Skirting, treads of steps and landing laid on a bed
of 12 mm (average) base of cement mortar 1:3 ( 1 cement: 3 coarse
sand) on new surface or fixing on existing flooring by adhesive material
and jointed with color cement slurry including finised with flush
pointing & cleaning the surface etc. complete for Colour and Shade
approved by Engineer-In-Charge
51 P & L 60x60 cm Hand Dressed Rough Kota Stone slab 30 mm thick 694.80 Sqmt 1121.80
flooring over 20 mm (average)thick base of cement mortar 1:6 (1-
cement 6-coarse sand) or L.M 1:1.5 (1 Lime putty : 1.5 coarse sand laid
over and jointed with grey cement slurry mixed with pigment to match
the shade of slab including rubbing and polishing etc.complete
52 P & L 60x60 cm Hand Dressed Rough Kota Stone slab 25 mm thick in 41.10 Sqmt 1205.60
riser of steps,skirting dedo and pillars laid on 10 mm thick cement
mortar 1:3 (1-cement 3-coarse sand) and jointed with grey cement
slurry mixed with pigment to match the shade of slab including
rubbing and polishing etc.complete
53 P & L 30x30 cm. Coloured Ceramic Anti-Skid Textured Tiles 6 mm thick 29.90 Sqmt 1070.50
in flooring treads of steps and landing laid on a bed of 12 mm thick
cement mortar 1:3(1-cement:3-coarse sand)finishing with flush
pointing in colour cement slurry etc. complete. Colour and Shade
approved by Engineer-In-Charge
54 P & L 30x45 cm. Coloured Glazed Tiles 6 mm thick in skirting risers of 251.90 Sqmt 1523.67
steps and dedo on 10 mm thick cement plaster 1:3 (1-cement:3coarse
sand) and jointed with colour cement slurry
55 Providing and laying water proofing treatment with broken china 944.00 Sqmt 779.70
mosaic flooring for terrace using 12mm to 20mm of broken piece of
ceramic glazed tiles (or more colour directed ) to be laied over cement
mortar bedding of cm 1 : 3 (1 cement 3 sand ) to blain or slope and to
be tempered to bring mortar ceramic up to surface with using white
cement and colour pigment including rounding of junction extending
them up to 15cm along the wall and caring with bends any patten or
design on per drawing and clennig by using oxalic acid etc. Completed
56 Providing and fixing pre-cast Rubber Dye inter locking concrete block 196.90 Sqmt 707.55
60mm thick with grade of concrete M300 Pg.Noumatic
compressed/Vibrated mechanically and as per approved design
confieming to IS 15658: 2006 including 35 mm Sand layer for levelling
and filling the joint with sand in proper line and level as per guidelines
of IRC : SP 63-2018 etc complete.
57 Providing and fixing Mirrar polished 18 mm thick Granite stone in 185.30 Sqmt 2298.76
Single piece with edge finished and polished of approved quality in
clading on Cill & Jambs and around the doors/ windows/ ventilation
with 12 mm thick cement motor CM (1:4) and fixing with cement slurry
& adhesive including moulding of exposed edges as directed by
engineering in charge etc. complete.
58 Providinfg and fixing Safty grills of required pattern for windows/ Door 1360.80 Kg 116.15
using necessary 12mm M.S Round/ Square bar /M.S angle/ M.S pipe,
M.S flats and other structural steel at required spacing including
cutting, welding and fabriction etc. including one coat of primer of
approved quality and two coats of oil painting as per detail drawing etc
59 Providing erecting and fixing double coated Syntex PVC. (ISI) water 10000.00 Litre 3.95
tank of required capacity each with all necessary fittings and
connection etc. complete on terrace.
60 Providing laying and jointing in true line and level 50mm dia. U.P.V.C. 60.00 Rmt 195.67
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing of pipe and joints and
fixing the same with adhesive solvent, including cost of all materials.
61 Providing laying and jointing in true line and level 40mm dia. U.P.V.C. 50.00 Rmt 148.12
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing of pipe and joints and
fixing the same with adhesive solvent, including cost of all materials.
62 Providing laying and jointing in true line and level 25mm dia. U.P.V.C. 70.00 Rmt 91.84
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing of pipe and joints and
fixing the same with adhesive solvent, including cost of all materials.
63 Providing laying and jointing in true line and level 15mm dia. U.P.V.C. 70.00 Rmt 72.65
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing of pipe and joints and
fixing the same with adhesive solvent, including cost of all materials.
64 Providing, laying and jointing in true line and level 160 diametre 345.00 Rmt 834.38
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and
other end socketed with rubber ring, & fittings conforming to ISI 14735-
1999 of approved make for drainage system pipe line, pipe shall be
jointed with each other with rubber lubricant, pipe shall be fixed on
wall using of PVC clamp of the size 160 mm diametre x 210 mm length
x 196 mm heigh at every 2000 mm center to center or shall be
concealed in walls as directed including necessary fittings such as
bends, shoes etc. including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all materials.
65 Providing laying (to level or slopes) and jointing reinforced concrete 80.00 Rmt 678.03
Light duty non-pressure pipes I.S. class NP2 of the following internal
diameter with collars and butt ends prepared for collar joints including
testing of joints complete.(D) 300mm
66 Providing, laying and jointing in true line and level 110 diametre 25.00 Rmt 897.79
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and
other end socketed with rubber ring, & fittings conforming to ISI 14735-
1999 of approved make for drainage system pipe line, pipe shall be
jointed with each other with rubber lubricant, pipe shall be fixed on
wall using of PVC clamp of the size 110 mm diametre x 149 mm length
x 145 mm heigh at every 2000 mm center to center or shall be
concealed in walls as directed including necessary fittings such as
bends, shoes etc. including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all materials.
67 Providing, laying and jointing in true line and level 75 mm dia. UPVC 25.00 Rmt 765.58
SWRType B pipe conforming to IS 13592-1992 with one end plain and
other end socketed with rubbering and fitting conforming to ISI 14735-
1999 of approved make for drainage system pipe line, pipe shall be
jointed with each other with rubber lubricant, pipe shall be fixed on
wall using of PVC clamp at every 2000 mm c/c or shall be conceled in
walss as directed including necessary fittings such as bends, shoes etc.
including testing of pipes and joints and jointed with adhesive solvent
cement including cost of all materials.
68 Providing and fixing in PVC SWR cowel went 75mm dia to pipes.(B) 5.00 No 15.15
69 Providing and fixing in PVC SWR cowel went 110mm dia to pipes.(B) 5.00 No 27.27
70 Providing and fixing MS Z clamp on Wall or celling for Pipe Fitting 173.00 No 70.70
including all type necessary fittings and accessory etc. completed as
per directed engineer in charge.
71 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm 20.00 No 600.23
diameter with jali of the following nominal diameter of self cleansing
design with C.I scread down or hinged grating including the cost of
cutting and making good the walls.
72 Providing and fixing wash down water closet dual flushing system type 5.00 No 4141.00
(European type W C pan) with integral P and S trap including jointing
the trap with soil pipe in cement mortar 1:1 (1 cement five sand)
including providing and fixing plastic seat cover for wash down WC
with CP brass hinges and rubber buffers back plastic seat and 60 cm
long Heavy Duty Jet Spray including half turn flush cock dual flushing
system including cutting holes in walls and making good the same
connection the flush bend with cistern and closet vitreous china.
73 Providing and fixing ball cock of approved. quality as directed.(A) 2.00 No 189.84
Copper Metal (ii) 50mm dia.
74 Providing and fixing washbasin with single hole for pillar tap with C.I. 5.00 No 1486.04
or M.S. brackets painted white including sutting holes and making
good the same but excluding fittings.(A) Vitreous China:(ii) Flat Back
washbasin 550 mm x v 400mm size. (i) In white colour.
75 Providing and fixing C.P. brass waste for washbasin or sink. (A) 32mm 17.00 No 67.91
76 Providing and fixing M.I. fisher union for washbasin or sink. (A) 32mm 17.00 No 78.75
77 Providing and fixing 600mm x 450mm bevelled edge mirrror of 5.00 No 859.41
superior glass mounted on 6mm thick A.C. sheet or plywood sheet and
fixing to wooden pluge with C.P. brass screws and washers.
78 Providing and fixing C.P. brass towel rail comlete with C.P. brass 5.00 No 616.42
brackets fixed to wooden plugs with C.P. brass scews (B) 600mm x
79 Providing and fixing screw down bib taps of following size.(A) Brass 22.00 No 186.83
screw down bib tap polished bright. (i) 15mm dia.
80 Providing and fixing pillar tap, capstan head, screw down high pressure 17.00 No 308.73
with screws, shanks and back nuts. (i) 15mm dia.
81 Providing and fixing brass screw down stop tap.(A) 15mm dia. 20.00 No 205.83
82 Providing and fixing brass screw down stop tap.(C) 25mm dia. 5.00 No 220.82
83 Providing and fixing Gun metal check or non-return fullway wheel 5.00 No 663.43
valve.(E) 40mm dia.
84 Providing and fixing S.W. gully trap with C.I. grating brick masonry 6.00 No 1246.92
chamber and water tight C.I. cover with frame of 300mm x 300mm size
(inside) with standard weight (i) Square mouth traps (B) 150mm x
100mm size P or R type
85 Constructing brick masonry chamber for underground C.I. Inspection 5.00 No 3196.65
chamber and bends with briocks having croshing strength not less
than 35Kg. Cm2 in C.M. 1:5 precast RCC cover 455mm x 610mm intenal
dimensions with frame (R.C.C. top slabe with 1:2:4 mix (1-cement :2-
coarse sand :4-graded stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3
finished smooth with a floating coat of neat cement on walls and bed
concrete etc. complete (i) Inside dimensions 455mmx 610mm and
450mm deep for single pipe line.
86 Constructing brick masonry chamber for underground C.I. Inspection 5.00 No 3905.67
chamber and bends with briocks having croshing strength not less
than 35Kg. Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x
610mm intenal dimensions total weight of cover with frame to be not
less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C.
top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm
thick with cement mortar 1:3 finished smooth with a floating coat of
neat cement on walls and bed concrete etc. complete.(i) Inside
dimensions 500mmx 700mm and 450mm deep for single pipe line.
87 Extra over items for every additional depth of 0.1M. of part thereof 3.00 No 242.39
beyond 450mm depth for Brick masonry chamber.(i) for 455mm x
88 Extra over items for every additional depth of 0.1M. of part thereof 3.00 No 264.86
beyond 450mm depth for Brick masonry chamber.(i) for 500mm x
89 Providing cement vata (10cm x 10cm size) quarter round in cement 168.40 Rmt 24.28
mortar 1:1 including neat cement finishing watering etc. Complete
90 Providing and fixing Urinal or approved quality including conecting the 3.00 No 1074.86
Urinal with waste pipe , tap etc. complete.(A) White earthenware flat
back or corner type size 430mm x 260mm x 350mm.
91 Providing and fixing MS Ladder of required pattern with MS 100.00 Kg 115.14
flats(30x3mm) or round or square bars (12mm) at required spacing &
with round headed bolts and nuts or screws or welding including
primer coat of approved quality and two coats of oil paintas as
directed by engineer in charge
92 Providing and fixing polished 18 mm thick black granite with Edges 1.40 Sqmt 2061.41
finished and double side polished of approved quality in between
urinal and fixing with cement slurry & adhesive including moulding of
both exposed edges as directed by engineering in charge etc.
93 Providing and fixing 0.45 meter wide sand which type wash counter 0.60 Sqmt 3287.55
platform including supplying and fixing granite stone of 18 mm thick
mirror polished on top and side posiition and vertical strip at front
with cement slurry & adhesive including moulding of both exposed
edges over 25 mm thick kotah stone platform fixing in top and sides
and itermediates supports fixing with cement mortar and adhesive and
finishing with C.P. brass waste , M.I. fisher union,pillar tap,Rubber plug
all material and labour and assessories complete etc.
94 Constructing Sandwitch Platform of 18 mm thick Polished Black 21.00 Sqmt 2740.13
Granite at top and 25 mm thick Kota stone slab one side polished at
bottom with cementing Materials / adhsives including makeing
necessary grooves in walls with Vertical sandwich two Kotastone
mm support every 60 cm centre to centre or as required including all
labour material of approved quality incl. full moulded round front
edge granite strip of one side polished and jointed with grey cement
slurry including rubbing and polishing etc. complete for all floors
95 Providing and fixing in position 300 mm high, 150 mm wide 150.00 No 707.00
English/Gujrati letters made from 1.0 mm thick stainless steel sheet as
directed by Engineer in charge with all necessary tools & plants etc.
96 Providing and fixing of Ridge flashing for roof panel shall be made out 133.70 Sqmt 867.39
of 0.5 mm thick pre coated GI sheet . The Precoated sheet shall be of
minimum 240 mpa steel grade confirming to IS 14246:1995 and shall
have zinc coating of minimum 120 gsm as per IS:277:1992 , 5-7
microns epoxy primer on both side of the sheet and polyester top coat
15-18 micron. The PPGI Sheet shall have plastic protective guard film
of minimum 25 microns to avoid scratches during transportation. The
ridge shall be fixed to the steel members by pop rivet or self
drilling/self stitching fastners @ maximum 450 mm c/c along length of
capping/flashing etc complete.
97 Steel work, welded in built up sections framed work including cutting, 2673.00 Kg 91.08
hoisting, fixing in position and applying a priming coat of read lead
paint & two coat oil paint. (A)In beams and joists, channels angles
Tees, flats, with connecting plates or angle cleats as in main and cross
beams. Hip and jack rafters, purlins conneted to common rafters and
98 Providing and Fixing 15 mm thick 300 mm x 300 mm Tactile Warning 7.20 Sqmt 1228.16
Tiles (Attention Tiles i.e. Tactile Warning Surface Indicator {TWSI}) of
Johnsan Endura Tac Button Yellow Plus or equvqlent make in flooring
laid on 20 mm thick cement mortar 1:6 (1 cement : 6 coarse sand) on
new surface and jointed with cement slurry including finished with
flush pointing & cleaning the surface for all floors as per detailed
drawing etc. complete as directed by Architect or Engineer in charge.
Thse tiles shall be Anti Skid, Chemical Resistant, Fade Proof, Frost -
Heat & Weather Proof, High Flexural Strength, Highly Durable, Stain
Resistance . All Tactile Warning Tiles meet the specific size and
dimension standards as required by ISO/FDIS
99 Providing and Fixing a set of wall mounted 38 mm dia U shaped 1.00 Per 2555.30
horizontal stainless steel collapsible grab bar , 38mm vertical stainless Set
steel fixed grab rail of grade SS 304 from round pipe supported and
mm dia 8 mm thick SS 304 base flange on wall including anchor
fasteners, nuts, accessories as per detailed drawing etc. complete as
directed by Architect or Engineer in charge.
100 Providing upto floor two level precast cement concrete jali or grill 1:2:4 101.50 Sqmt 759.59
mix (1- Cement : 2- coarse sand : 4-graded stone aggregate 6mm
nominal size) reinforced with 1.6 mm dia. Mild steel wire including
roughening,cleaning, fixing and finishing in cement mortar 1:3 and
curing complete. (C) 25mm thick
101 Providing and laying and fixing 50 mm thick expansion joint by hydro 19.10 Sqmt 1491.03
cell semi rigid UV resistance with high performance laminated closed
cell polythene foam joint filler in sheet foam as directed, etc.
102 Applying and providing Expansion joint sealing System on 100 mm vide 19.10 Sqmt 4772.00
joint including cleaning of exansion joint by mechanical means
provision of adhesive and flexible membrane with required bond
length as per menufracturer specification and 4mm thick alluminium
strip covering with one side sloted and bolted with suitable system,
inclusive of all manpower, machinery and material as per specification
and as directed.
103 Providing and filling the expansion joint by Thioflex 600 polymer or 19.10 Sqmt 515.39
equivalent confirm to BS 4254-1983 as per required shade and
manufactured specifi-cation by making groove of 50 mm x 12.5 mm
lather by cutting or by repairing groove and removing mortar drop or
any other foreign materials including applying primer and filling
required size (oversize of joint PU foam etc. complete.
104 Providing and fixing 25 cm Wide & 3mm thick exterior composite panel 19.10 Sqmt 1054.34
on existing expansion joint horizontally & vertically with all material,
hardware, acessories & fittings etc completed.
105 10mm Rebar, excluding bar. It should minimum 100mm embedded in 80.00 Nos 114.13
concrete, drill dia. Should be minimum 18mm for rebar, material
should be used Will Fischer FISV 360 or equievalent. (Pull out strength
check should be given by contractor as per technical specifications)
106 Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working 280.00 Rmt 339.05
pressure poluthene pipes of the following outside Dia. Low densidy,
complete with special falnge compression type fittings, wall clipsetc.
including making good the wall ceiling and floor.(G)110 mm
107 Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working 50.00 Rmt 689.83
pressure poluthene pipes of the following outside Dia. Low densidy,
complete with special falnge compression type fittings, wall clipsetc.
including making good the wall ceiling and floor.(G)160 mm
108 Providing junction for rain water juncton chamber of size 4.00 No 6613.48
0.60x0.60x0.75m with excavation of size 1.96x1.96 m & 0.15m thick
c.c.1:2:4 bed concrete including brick masonary wall in CM 1:6 of
0.75m height & 0.23m thick with 15mm thick cement plaster inside &
outside & 1.06x1.06 RCC (1:2:4) slab of thickness 0.15m with CRS steel
and 0.60mx0.45m cast iron manhole cover with frame weight not less
than 35 kg as per directed by Engineer-in-charge
109 Providing Filter chamber of Brick work in C:M 1:6 of size 2.06mx1.20m 1.00 No 19572.79
x1.20m & excavation dimension of 2.82mx 1.96x1.35m including C.C
1:2:4 bed concrete of 0.15m thick including brick work in c.m 1:6 for
23cm thick wall including 15mm thick cement plaster inside & outside
with cement slurry & 10cm thick RCC 1:2:4 top cover with frame of
minimum weight of 35 kg & filling filter material kapchi in layers (25-
40mm & 10-20mm) & BT metal 40mm & sand as per directed by
Engineer-in-charge.
110 Drilling in soil with lowering of pipes concrete sealing including gravel 30.00 Rmt 545.40
packing clay breaking and development of bore with air compressor by
required capacity vertical test etc. complete including the cost of
benimeter 250mm dia.
111 Supplying slotted PVC pipes of approved quality at site of work 30.00 Rmt 555.50
confirming to IS. 1239/1974 180mm dia.
112 Constructing brick masonry chamber for underground C.I. Inspection 1.00 No 7180.44
chamber and bends with briocks having croshing strength not less
than 35Kg. Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x
610mm intenal dimensions, total weight of cover with frame to be not
less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C.
top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm
thick with cement mortar 1:3 finished smooth with a floating coat of
neat cement on walls and bed concrete etc. complete.(iii) Inside
dimensions 600mm x 850 mm and 450mm deep for pipe lines with
three or more inlets.
113 Box cutting the road surface to proper slope and camber for making a 164.00 Cumt 112.02
base for road work including removing the excavated stuff and
depositing on the road side slope as directed upto 50Mt.lead.
114 Construction of granular sub-base 150 mm thick by providing coarse 55.00 Cumt 1282.70
graded machine crushed B.T. material satisfying MOST specification of
grading I (B.T. stone aggregate 53 mm to 26.5 mm 35 %, 26.5 to
mm - 45 % and 2.36 mm below - 20 % )including spreading in uniform
layer with motor grader on prepared surface, mixing by mix in place
method with rotavator at OMC and compacting with vibratory roller to
achieve the desired density etc. complete.
115 Providing and laying wet mix macadam base course 200 mm thick 73.00 Cumt 1335.22
using machine crushed B.T. chips as per required gradation mixing with
required optimum quantity of water, conveying the mix to site of
work, spreading in to grade and camber with mechanical paver and
consolidation each layer with vibratory roller including cost of material
labour plant and equipment etc. complete.
116 Providing and laying controlled cement concrete M.150 and curing 44.00 Cumt 3898.54
complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in (A) Foundations and
117 Providing &laying ave. 200 mm thick M-250 grade of controlled 73.00 Cumt 5826.69
cement concrete including dressing sub base providing and laying
micron thick LDPE memberance over prepared sub base providing and
mixing recron 3s fiber at 875 gm/cmt. of concrete placing the concrete
and leveling with surface vibrator finishing the surface with power
floater and trowel light brooming on the surface as directed including
Providing and filling exparsion joint having size 20 mm x 115 mm &
filling the expansion joint having size 20 mm x 20mm by using cloper -
200 as per manufacturer's specification and making construction joint
having size 10 mm x 10mm by using concrete cutter machine etc.
Providing and fixing pre-cast concrete kerb stone of gray cement based 140.00 Rmt 374.92
concrete block 30cm length,30cm height and 15cm thick of M250
grade concret as per approved design and including excavation for
fixing in proper line and level,filling the joint with C:M 1:3
(1cement:3fine sand) etc complete.
119 Providing, laying (to level or slopes) and jointing reinforced concrete 47.00 Rmt 659.99
Light duty non-pressure pipes I.S. class NP3 of the following internal
diameter with collars and butt ends prepared for collar joints including
testing of joints complete. (i) 300mm
120 Clearing and grubbing road land including uprooting rank vegetation 0.62 Hrct 28455.10
grass bushes, shrubs, sapling and trees girth up to 300 mm removal of
stumps of trees cut earlier and disposal of unserviceable materials (C)
By mechanical means in area of light jungle
121 Earthwork for embankment including breaking clods, dressing with all 6655.00 Cumt 173.31
lead and lift (excluding watering and consolidation)(E) From Borrow
area within 3.0 Km. lead
122 Rolling of earthwork in layers with power roller including filling in 6655.00 Cumt 23.18
depressions which occur during the process and Watering of earth
work as directed.
123 Excavation for foundation up to 1.50 Mt. Depth including sorting out 108.00 Cumt 160.89
and stacking of useful materials and dispossing on the excavated stuff
upto 50 M. lead ( B ) Dense Or Hard soil
124 Providing and laying cement concrete 1 : 4: 8) (1 cement : 4 coarse 36.00 Cumt 2781.12
sand : 8 stone aggregate 40 mm nominal size ) and curing complete
excluding cost of formwork in foundation and plinth.
125 Providing and laying weep hole in Aburtments, and returns by using 47.00 Nos 88.76
A.C. pipe of 100mm including laying in proper grede and jointing the
completed as per detailed specification.
126 Providing and fixing decorative entrance gate made out of cast iron 480.00 Kg 124.23
and various mild steel tabular section combination , the Ornamental
entrance gate should be fixed at compound wall including pattern and
die making , cutting , welding , grinding, fabrication , fixing in position
at compound wall with necessary pedestal, bearing block and other
locking arrangement. The entrance gate should be painted with two
coats of priming coat of paint, and two coat of oil paint etc complete.
As per detail design and instruction of architect.
127 Providing and fixing concertina coil fencing with punched tape 60.00 Rmt 349.46
concertina coil 600 mm dia 10 mt openable length having 50 no
rounds per 6 mt length, upto 3mt height of wall with angle iron (50mm
x50mm x5mm) requird shaped As per Directed Engeenier in charge.
placed 2.4mt or 3.00mt apart and with 4 horizontal R.B.T. reinforced
barbed wire(3 mm) , stud tied with G.I. staples and G.I. clips to retain
horizontal, including necessary bolts or G.I.barbed wire tied to angle
iron, all complete as per direction of Engineer-in-charge, with
reinforced barbed tape (R.B.T.)/Spring core (2.5 mm thick) and weight
43.478 gm/meter at compound wall for ESR M4/ intakewell.
128 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 213.00 Pt. 485.81
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length , in below type of pipe
erected with 6A Modular type switch / bell push & accessories and
earth continuity of following type, erected on PVC / Metallic/Wooden
box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling rose /
H.D.Connector as directed.(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling complete Cat. III
129 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm 57.00 Pt. 674.68
(Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length, in below type of pipe erected
with 6A Modular type switch and hum free EME step type electronic
fan regulator mounted and accessories with earth continuity of
following type erected on PVC / Metallic/Wooden box, single
mounting base frame covered with textured/metallic/white front
plate modules erected on / in wall / ceiling as per pipe erected. with
necessary ceiling rose / H.D.Connector as directed. (f) with medium
class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete Cat. III
130 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) 26.00 Pt. 510.05
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate modules
erected on / in wall / ceiling as per pipe erected with following type of
accessories. [I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire
from nearby switchboard/mcb db board (f) with medium class Rigid
PVC pipe and accessories erected concealed in wall/ceiling complete
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) 19.00 Pt. 745.38
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate modules
erected on / in wall / ceiling as per pipe erected with following type of
accessories. [II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu.
Wire from mcb db board. (f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling complete Ca-III
132 Point wiring for on board Looped Plug with 6A Modular type switch & 33.00 Pt. 257.55
5 pin socket erected on PVC / Metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
modules erected on / in wall / ceiling with following type accessories
133 Providing following type of Modular Type Accessories mounted with 16.00 Nos 160.59
PVC / metallic/Wooden box, single mounting base frame covered with
textured / metallic/white front plate , modules erected with necessary
connections as per site situation directed by Engineer In charge.(3)
Two Pin/RJ-11 Telephone Socket[A] For One GangCat.III
134 Providing following type of Modular Type Accessories mounted with 10.00 Nos 25.25
PVC / metallic/Wooden box, single mounting base frame covered with
textured / metallic/white front plate , modules erected with necessary
connections as per site situation directed by Engineer In charge.(7)
Blank Plate Single.Cat-III
135 Providing following type of Modular Type Accessories mounted with 20.00 Nos 160.59
PVC / metallic/Wooden box, single mounting base frame covered with
textured / metallic/white front plate , modules erected with necessary
connections as per site situation directed by Engineer In charge.(8)
Computer RJ-45 socket Cat.III
136 Providing following type of Modular Type Accessories mounted with 10.00 Nos 410.06
PVC / metallic/Wooden box, single mounting base frame covered with
textured / metallic/white front plate , modules erected with necessary
connections as per site situation directed by Engineer In charge.(14)
6A/ 10A/ 16A/ 20A/ 25A/ 32A Double Pole Modular MCB Switch Ca-III
137 Providing and erecting ISI mark Medium class RIGID PVC PIPES of 1110.00 Mtr. 24.24
following size complete to be erected on/in wall or ceiling erected
with necessary PVC fittings & Junction boxes fixed with adhesive
solution & Clamps with following dia of pipes, in approved manner as
directed (a)20 mm
138 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI 795.00 Mtr. 82.82
marked stranded Copper conductor wire in following type of pipe to
be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm
copper conductor FRLS PVC insulated stranded wire of green colour for
earth continuity of following size(A) With medium class Rigid PVC pipe
and accessories(b) 2 wire 2.5 sq. mm
139 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI 40.00 Mtr. 112.11
marked stranded Copper conductor wire in following type of pipe to
be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS
PVC insulated stranded wire of green colour for earth continuity of
following size(A) with medium class Rigid PVC pipe and accessories (a)
2 wire 4 sq. mm
140 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI 140.00 Mtr. 260.58
marked stranded Copper conductor wire in following type of pipe to
be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS
PVC insulated stranded wire of green colour for earth continuity of
following size(A) with medium class Rigid PVC pipe and accessories(h)
4 wire 6 sq. mm
141 Providing and erecting Mains with ISI marked, 1.5KV grade electrolyte 60.00 Mtr. 91.91
multi stranded, annealed copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays, power switchgears,
motor starters & control wiring) with required size of copper lugs, nuts
and bolts if required.(f) One wire 10.00 sq. mm
142 Providing and erecting Mains with ISI marked, 1.5KV grade electrolyte 30.00 Mtr. 236.34
multi stranded, annealed copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays, power switchgears,
motor starters & control wiring) with required size of copper lugs, nuts
and bolts if required.(h) One wire 25.00 sq. mm
143 Supplying and erecting Flexible PVC insulated multi strand multi core 60.00 Mtr. 46.46
1.1 kv grade ISI marked copper wires of following size to be erected as
directed.(e) 1.50 Sq.mm 3 core round PVC sheathed
144 Supplying & erecting approved make Telephone Cable electrolytic 560.00 Mtr. 20.20
copper conductor PE insulation twisted in two pairs, & wrapped with
FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable
for telephone wiring & confirming to C-DOT erected in existing pipe. of
following size of conductors & nos.of pairs. With necessary
connections.[A] Conductor Size 0.5 mm (a) Unarmoured(2) Two Pairs
145 Supplying & erecting approved make LAN cable of following size in 750.00 Mtr. 47.47
existing pipe as per direction[C] CAT -
146 Providing & erecting main Distribution (MDF) indoor type, back 1.00 Nos. 994.85
mounted frame as per DoT standard approved with krone strips(a)
Suitable for 10 pair
147 Providing & erecting Switch board for Computer or electric apparatus 20.00 Nos. 1133.22
consisting of following modular type accessories mounted with PVC /
Metallic concealed/open box with single mounting base frame covered
with textured/metallic /white front plate,modules erected with
necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type Accessories
148 Decorative call bell Ting-tong box type 250 volts complete erected 8.00 Nos. 71.71
149 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 195.00 Nos. 535.30
Watt to 0.5 Watt assembled on single MCPCB, with housing used as a
heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company mark/name 160V to
270V, Power Factor more than 0.95, THD < 15%, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt, LED driver efficiency > 85 % (
fitting required LM-79 & LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges
shown.)(A) Tube Light with integral driver(v) 36-40 Watts, Surge-2 KV,
IP-20, conventional 4 feet Cat-III
150 Supplying and erecting led lamps with following wattage capacity of 4.00 Nos. 112.11
220 to 240 voltage, minimum 15000 burning hours life, 500 V in built-
surge protection,Polycarbonate diffuser, mounting suitable for E14 /
E27 / B22 lamp holders, pf >= 0.5 (A) LED Lamps integral type, with PC
diffuser suitable LAMP holder (ii) 5 to 8 watts Cat-III
151 Replacing old & u/s led streetlights by Supplying and erecting LED 12.00 Nos. 3345.12
street light / Flood light fittings with High power White LEDs wattage
of 3 Watt and above assembled on single MCPCB, efficiency more than
130 lm/w and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded aluminium
with diffuser and Polycarbonate optics/ lenses, with toughened glass
with company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity
ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80 certificates)(old -50 ,new -
20(NOTE: Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)(A) Street Light (IP-65), Surge protection -
4KV integral and ,Light must have 440VAC line supply with over-
voltage protection. (i) above 36 to 48 watts Cat-III
152 Replacing old & u/s led streetlights by Supplying and erecting LED 4.00 Nos. 7266.95
street light / Flood light fittings with High power White LEDs wattage
of 3 Watt and above assembled on single MCPCB, efficiency more than
130 lm/w and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded aluminium
with diffuser and Polycarbonate optics/ lenses, with toughened glass
with company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity
ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80 certificates)(old -50 ,new -
20(NOTE: Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)(B) Flood Light (IP-65), Surge protection -
4KV integral and ,Light must have 440VAC line supply with over-
voltage protection. (iv) above 90 to 120 watts Cat-III
153 Replacing old & u/s led streetlights by Supplying and erecting LED 4.00 Nos. 4819.72
street light / Flood light fittings with High power White LEDs wattage
of 3 Watt and above assembled on single MCPCB, efficiency more than
130 lm/w and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded aluminium
with diffuser and Polycarbonate optics/ lenses, with toughened glass
with company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity
ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80 certificates)(old -50 ,new -
20(NOTE: Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)(C) Post Top Lantern LED fitting comprises
of finish cast aluminum spigot and spun aluminum canopy fixed with
opal polycarbonate, pipe arrangement for vertical mounting driver and
accessories wired upto terminal block.IP 65(ii)32-40W Cat-lll
154 Providing and erecting Approved make Four pole moulded case circuit 1.00 Nos. 8055.76
breaker having breaking capacity ICU of 35 KA. at 415 V. having normal
current rating 125A. with Fixed thermal & magnetic release suitable to
work on A.C.supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III
155 Providing and erecting Approved make Four pole moulded case circuit 1.00 Nos. 8861.34
breaker having breaking capacity ICU of 35 KA. at 415 V. having normal
current rating 125A. with Fixed thermal & magnetic release suitable to
work on A.C.supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in with 16 G.M.S. housing.
ICS=100% of ICU only Cat III
156 Providing and erecting Approved make Four pole moulded case circuit 9.00 Nos. 6173.12
breaker having breaking capacity ICU of 25 KA. at 415 V,having normal
current rating up to 25 A to 100A. with Fixed thermal & magnetic
release suitable to work on A.C. supply 50 c/s. with all internal
connections, spreader tinned copper & complete erected in existing
G.M.S. housing.
157 Providing and erecting Approved make Earth fault Relay suitable to 1.00 Nos. 4983.34
mount with inter connection suitable to following size of moulded
case circuit breaker having CT ratio & MCCB rating as following along
with shunt trip 220V AC. with all internal connections & complete
erected in existing M.S.housing.. (2) 125 A -200 A , CT Ratio 1/200
158 Supplying and erecting triple pole & neutral 440V / 500V panel 1.00 Rmt 1961.42
mounting Copper Busbars with four equal Nos. of electrolyte bus
having current density not more than 1.6 Amp. / sq.mm (Rated current
/ cross section area) duly wrapped with colour insulating tape for
phase sequence of following current carrying capacity, erected with
necessary bus bar supports /insulators, main cable socket to each bar,
erected in existing cubical panel with necessary connections.(A)
Suitable for 100 Amp. Capacity
159 Providing and erecting Miniature circuit breaker single pole 0.5A to 2A 20.00 Nos. 270.68
system and having breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark Cat.III
160 Providing and erecting Miniature circuit breaker single pole 6A to 25A 72.00 Nos. 112.11
suitable to operate on 240 V A.C. system and having breaking capacity
10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI
161 Providing & erecting 240 V MCB double pole switch for motor & 4.00 Nos. 330.27
inductive load (C Curve) having 10 KA breaking capacity & confirms
to IS : 8828 in existing box having following capacity (B) 40 Amp.
162 Providing and erecting Sheet Steel powder coated MCB distribution 4.00 Nos. 2913.85
board - flush / surface mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs should be used of
same company of MCB to be used) suitable for(B) three phase
incoming and single phase horizontal type outgoing Per phase
isolation type (PPI)(b) sheet steel double door(ii)6 way
163 Providing and erecting Approved make RCCBs conforming to IS: 12640 13.00 Nos. 2235.13
and having sensitivity of 30 mA and Short Circuit withstand capacity of
10 KA and suitable for operation on single phase 240 V,50Hz. having
characteristic of quick action & tripping with all advance feature & do
not incorporate any electronic component. for following Max. rating
erected as directed(ii) 40Amps. DP Cat. III
164 Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 30.00 Kg. 77.77
165 Providing and erecting Pipe type earthing having 150 cms.long and 2.5 3.00 Nos. 368.65
cms. dia. galvanised iron pipe with coupling and buch buried in
specially prepared earth pit complete with necessary 8 SWG earth
166 For using salt and charcoal / coke as required for pipe type earthing. 3.00 Nos. 171.70
167 Supplying & erecting earth pit of minimum bore dia.150mm size 2.00 Nos. 4591.46
approved make Earthing Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 50mm having 80-200 Micron galvanising,
Inner pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic value
surrounded by highly conductive compound with high charge
dissipation suitable for following type of applications with chamber
and heavy duty cover. (A)(approved make OEM has to submit test
certificate including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to ensure the
value of earthing resistane mentioned in test Certificate) & having back
filling compound of (a) For Electrical Installation up to 440V in normal
Length of pipe - 1 Mtr
168 Back filling&compound
Providing - 1 Nos proof,
erecting weather Bag of dust
& vermin proof, floor 2.00 Sqmt. 10468.65
mounted front operated indoor type cubical panel board necessary IP-
42 and above protection as per approval from engineer incharge
made from 14 SWG thick CRC M.S. sheet for outer body & doors,
SWG thick CRC M.S.sheet for internal partitions with necessary
accesories , supporting angles/ flats channel including cutting,
bending, drilling, welding, riveting with internal partitions & cable alley
as per requirements & instruction of engineer-in-charge with erection
of supplied switch gears, BUSBARS, suitable size of inter connecting
PVC copper wire / copper-aluminium strips, rubber grommets, rib,
bakelite control fuses/MCB for measuring instruments, earth bus &
earth bolts, foundation flange - bolts-base Plates, sufficient nos. of
hinged doors, handles with locking arrangement and rubber
gasket,heavy duty end terminal connection,danger notice
board,necessary ventilation,earthing strip complete. The Panel shall
be painted with epoxy powder coating. (The rates excludes the cost of
switchgears, bus bars, inter connecting mains & Copper Aluminium
169 Providing , erecting , fabricating the M.S. structure as per requirement 25.00 Kg. 77.77
on site incorporating proper size of M.S. angles,square,round, flats,
bars, channels, sections complete with cutting, welding, grinding &
finishing duly painted with one coat of red oxide with erection on site
as per direction of engineer in charge with necessary grouting,
cementing, plastering & finishing complete.
170 Providing and erecting XLPE(IS:7098) (I)-88 ISI armoured cable 50.00 Mtr. 378.75
multistrand Aluminium conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of following size of cables
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core)
171 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable 450.00 Mtr. 126.25
multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following size of
cables(B) 4 core 6 Sq. mm
172 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable 50.00 Mtr. 140.39
multistrand Aluminium conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of following size of
cables(C) 4 core 10 Sq. mm
173 Making trench in soft soil of suitable width of 90 cm deep for laying 450.00 Mtr. 55.55
cable or locating the fault all over the run and back filling the same
and making the surface as normal ground.
174 Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below 40.00 Mtr. 226.24
ground across the road crossing or on floor with necessary material in
an approved manner and making the ground as per original.(F)
175 Providing & laying approved make Double walled corrugated pipes 410.00 Mtr. 62.62
(DWC) of polyethylene(conforming to IS 14930 II )with necessary
connecting accessories of same material at required depth in existing
trench for laying of cable. below ground / road surface for enclosing
cable (A)50 mm outer dia
176 Providing and, fixing heavy duty flange type brass cable gland with 18.00 Nos. 38.38
rubber ring for PVC insulated armoured cable complete with out going
tails, insulating tape etc for following size of cables.(B) 2 to 4 core 6 Sq.
177 Providing and, fixing heavy duty flange type brass double compression 2.00 Nos. 75.75
type cable gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for following size of
cables.(B) 3 & 1/2 core 35/50 Sq. mm
178 Providing and, fixing heavy duty flange type brass double compression 6.00 Nos. 103.02
type cable gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for following size of
cables.(C) 3 & 1/2 core 70 Sq. mm
179 Solder less crimping type Aluminium lugs conforming to IS suitable for 36.00 Nos. 6.06
cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut
bolts in an approved manner. (A) 1.5/ 2.5/4/6 Sq.mm
180 Solder less crimping type Aluminium lugs conforming to IS suitable for 2.00 Nos. 20.20
cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut
bolts in an approved manner. (D) 35/50 Sq.mm.
181 Solder less crimping type Aluminium lugs conforming to IS suitable for 6.00 Nos. 25.25
cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut
bolts in an approved manner. (E) 70 Sq.mm..
182 Providing & erecting Approved make Ceiling Fan with double ball 57.00 Nos. 1738.21
bearing ISI mark with condenser A.C.230V 50c/s. 1400 mm. sweep
complete, canopy erected on existing hook or clamp with earthing [
Make shall be approved by Engineer in Charge]
183 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. 57.00 Mtr. 108.07
Pipe down rod erected duly painted for fan complete with proper
insulation without leakage and earthing.
184 Supplying & erecting Fan Hook of 10 mm M.S. Round bar grouted in 57.00 Nos. 43.43
RCC slab with Making the site as original.
185 Supplying & erecting approved make low noise decorative exhaust fan 6.00 Nos. 1703.87
having square frame ABS body with inbuilt lowers & square
frame.200mm with 1350RPM Cat.II
186 Supplying and erecting approved make Octagonal pole made from HR 9.00 Nos. 6874.06
sheet steel. The pole should be made as per IS. and shall be coated
with hot dip galvanizing as per IS 2629/2633/4759, suitable suspend
local wind speed with integral Junction box consist of terminal plate of
min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for
MCB Mounting, stud type terminal and arrangement for cable
termination to be erected With Suitable foundation (Included) as per
details given by manufacturer considering site requirement.(D) 5 Mtr.
Long 70 mm Top X 135 mm bottom dia, 3 mm thickness with
200mmX200mmX12mm base plate, 4-M20 Bolts and 600mm long with
necessary G.I. J Bolts .Approx Pole weight 59 kg
187 Supplying & erecting approved make SMC press moulded composite 8.00 Nos. 476.72
FRP. loop-in, loop-out approx. 2mm thick box complete with Bakelite
connector strip 5way(3P+N+E),DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements with mounting
clamp with nuts, bolts & washers suitable for erection on pole with
cable clamps& earth bolt of following size of box.(C)150mm x 125mm x
188 Supplying and erecting Street light pole bracket comprising main B 10.00 Nos. 476.72
Class GI pipe of 4.2 cm/require outside dia. complete with suitable B
Class G.I. sleeve tubing of approx. 45cms.length and suitable for
76.5mm/80mm/require size of pole top having nuts and bolts for fixing
the brackets and having spread of 0.5 mtr. Length with 110 deg.with
vertical plane and suitable welded stiffener reducer and nipple with
check nut complete painted with one coat.of Red oxide / PU base
primer and two coats of Aluminium / PU paint. paint with following
nos of arms.[A] Single Arm bracket 0.5 Mt
189 Supplying and erecting Street light pole bracket comprising main B 3.00 Nos. 622.16
Class GI pipe of 4.2 cm/require outside dia. complete with suitable B
Class G.I. sleeve tubing of approx. 45cms.length and suitable for
76.5mm/80mm/require size of pole top having nuts and bolts for fixing
the brackets and having spread of 0.5 mtr. Length with 110 deg.with
vertical plane and suitable welded stiffener reducer and nipple with
check nut complete painted with one coat.of Red oxide / PU base
primer and two coats of Aluminium / PU paint. paint with following
nos of arms.[B] Double Arm Bracket 0.5 Mtr
190 Supplying & erecting IP 55 grade following size section pillar fabricated 1.00 Nos. 3595.60
from joint less M.S. Sheet with angle iron legs made from jointless M.S.
Angle with cable clamps to be buried in ground to have appropriate
erection to work uniform until erected with cement concrete
foundation and 45 cm high bricks work finishing with plaster etc.
hinged double door internally supported on both side, with internal
and outside looking arrangement with look and keys in duplicate 35 x
35 x 5 mm M.S. Angle of Two Nos. one is welded and other with nut
and bolt for erecting Bakelite sheet. Painting the Section Pillar inside
and out side with three tank powder coated paint. section pillar roof
should be without joint with water leakage proof & tested as per IP
test & followed by IS 2147 of 1962(B) 75 X 60 X 45 cm section pillar
fabricated from 16 Gauge MS Sheet with angle iron legs 45 cm long
made from 35 X 35 X 5 mm thick MS angle.
191 Supplying & erecting approved make Digital time switch having lithium 1.00 Nos. 3168.37
cell 6 years operative and operate battery backup 1 channel day clock
with 14 memory programme, suitable to operate on 240V + 5%, 16A
with, floating contacts Minimum switching setup time 1 minimum &
LCD display. Also comprised permanent ON/OFF switching.
Programming switches & housed in fire proof thermoplastic enclosure
& transparent cover erected as required with necessary connection
erected as directed.
192 Supplying & erecting power contactor ,AC3 duty for time switch 1.00 Nos. 2782.55
complete erected as per direction Cat III (D) 4 pole 440V 40 Amp.
193 SITC of Digital / PCM / TDM EPABX System having SMT design, system 1.00 Nos. 51440.31
with flexible universal slots. Inbuilt Auto attendant facility, Minimum
15 Nos. conference, Analog extension line, Calling GSM, E&M line, PRI
/ EI & VOIP program me through Analog telephone digital key from
Ethernet, public address cord, shall have unrestricted simultaneous
dialing facility, QSIG protocol on PRI, 95 / STD / ISD / Local-Locking,
Class of Service, Quick Dial-Single Digit dialing of any two external
number, Once only ring device, Chairman / Secretary - Do not disturb
Facility, Power Down Mode, Hot Line, Hot Outward Dialing, Day Night
Mode, Auto Call Back, Barge-in, Call Pick Up & Call Transfer, Call
transfer while Ringing with Voice Guide System, (DISA), Caller ID (CLI),
CLI Base ECF, CLI Base routing Internet Ready Port, External Music Port,
Call Budgeting, Call Most Calculation (ASMDR), DID Direct Inverse
Dialing, External Music Input, Fax Homing, Global Directory Printing
with following capacities [[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ][B] No of Extension 24, No of
Junctions 9, 8 Port IP Resource in-built, 4 Port Web base Video
194 Supplying & erecting push button type telephone instrument having 13.00 Nos. 898.90
speaker phone Caller ID & speaker phone with one touch memory
(min.6 nos.)& 99 memories with display system Single line [[Approved
by Competent Authority i.e. not Below the rank of Executive Engineer ]
195 Providing and erecting Inverter based approved make split air- 5.00 Nos. 56353.96
conditioning unit consisting of condensing unit with variable speed fan
motor, inverter type hermetically sealed rotary compressor with
accessories etc. duly connected separately erected evaporating unit
196 Supplying and erecting insulated pair of soft copper tubing open or 35.00 Rmt. 746.39
concealed including power and control cable,necessary PVC drain
pipes for Split AC machine up to 4 TR capacity
197 Supply and Erecting of Static Stabilizer suitable for following capacity 5.00 Nos. 4029.90
of A.C Machine the Stabilizer Must have Minimum Technical
Specification are Input working Single Phase Voltage Range Up to 150V-
280V.50Hz, Output Voltage Range Up to 200V-240V,50Hz,Autoreset
198 Providing & erecting water cooler having storage capacity 150 Ltr. & 1.00 Nos. 55893.40
cooling capacity 150 Ltr.per hour @ an ambient temp of 45˚ C. The
outlet temp. of the water should drop by 15˚C within a hour, The
water cooler should be comprising of hermetically sealed compressor,
fan motor, condensing unit, water tank surrounded by evaporating,
coil, thermostats, relay etc.complete with necessary inlet & outlet
connection. The body of water cooler will be made from Stainless
199 Supplying & erecting reverse osmosis (RO) water purification system 2.00 Nos. 55893.40
with M.S. powder coated pedestal frame, prefilter housing carbon
filter suitable buster DC pump, auto low & high pressure switches with
following size of LPH capacity & erected as directed [C] 50 Ltr / Hr with
150 psi 2 nos booster pump
200 Supplying and erecting horizontal / vertical mounting type storage 1.00 Nos. 11455.42
water heater with copper container housed in M.S./S.S./ABS body
insulated with glass wool/puff complete with heating
elements,adjustable thermostats 300C to 850C, indicating lamp,
safety valve, fusible plug, etc.complete erected with coach bolts, nuts.
washers & cementation (C)25 Ltr. with 2 KW. heating element
Premium Category
201 Supplying and erecting approved make panel mounting type Digital 1.00 Nos. 1275.63
Voltmeter having 3 digits LED display, 0 to 750 AC Volts range erected
on existing panel board with all connection, wiring etc .with
manufacturers calibration certificate.
202 Supplying and erecting approved make panel mounting type Digital 1.00 Nos. 1558.43
Ammeter having 3 digits LED display, external CT operated, calibrated
for 0 to 1000 Amps suitable to operate on 500 Volt AC , erected on
existing panel board with all connection, wiring etc .with
manufacturers calibration certificate.
203 Supplying and erecting Ammeter / Voltmeter selector switch for 3 1.00 Nos. 317.14
phase AC Supply 500 V on existing panel board with necessary
204 Providing & erecting L.T. Current Transformer with bar primary 50/5 1.00 Nos. 274.72
to 1000/5 ratio 15 VA burden erected in existing CRCA box duly
secured with insulating materials connected to the meter
205 Supplying and erecting approved make suitable panel indicator LED 3.00 Nos. 43.43
type lamp, lens cover, complete erected with necessary connections.
206 Providing & erecting open well horizontal mono block pump set with 1.00 Nos. 18746.61
cast iron body, complete for three phase submersible motor
having.[D] For 5 HP 3 phase open well horizontal mono block pump set
suitable for 1350 LPM to 310 LPM @ 10 to 42 Mtr head suitable for
50/65 mm dia delivery pipe.Cat.II
207 Supplying and erecting Direct-on-line, Starter with 15A.rating 1.00 Nos. 2046.26
contractor and with 4-14A. range, directly operated thermal overload
relay in sheet steel enclosure for 3phase 415V.50 c/s. A.C. motor up to
7.5 H.P.complete erected on P.W. Block with necessary connection.
208 Lowering of submersible motor pump set at the depth of following 1.00 Nos. 856.48
,complete with required. Nos. and size of casing pipes erected by
means of proper chain pulley block & pipe wrenches after checking of
threads of each pipe with coupling to take the load of the pump set
and pipe assembly filled up with water (D)For Open well Horizontal
submersible pump set for sump well (i) 1 HP to 5 HP
209 Providing and erecting ISI marked PVC insulated PVC Sheathed Flat 10.00 Mtr. 104.03
flexible Submersible copper cable approved make of following Size.(B)
3 Core x 2.5 Sq. mm.
210 Supplying, & erecting C.I. swing, check type non-return (Reflux) Valve - 1.00 Nos. 1020.10
ISI marked suitable for following size.(A) 50 mm dia.
211 Supplying of following size of HEAVY UPVC column pipe with coupler 10.00 Mtr. 359.56
and wire lock.[B] 50 mm dia
Rupees Three Crore Ten Lakh(s) Thirty Thousand Four Hundred Forty Seven And Paise Forty Only
put to Tender Rs. 31030447.40 put to Tender Rs.
Deduction …………….. % below………………… Add ………… % above Rs. …………….
1 The Contractor shall be exhibit board as per government circular No.BDG/3277/1657 N dated 26/01/1997 S (M.GUJ) with
detailed specification and details of work and amount Involved at site without any payment as directed by Engineer-In-
2 All work shall be carried out as per public work department hand book and other specifications of Division or as directed.
3 All columns in the Schedule should be filled in ink & the total of the entries in the last column should be struck by
Contractor under his sign.
4 Rates quoted include clearance of site (Prior commencement of work and its close) in all respects and hold good for work
under all condition, site, moisture/ weather etc.
5 The Boards stating the detailed specification & detailes of Work shal be provided by the contractor as per Government
Resolution T.No.1890-240- Dtd.18/11/1990 and directed by contractor at his own cost immediately on recommanding the
6 Testing of Material Shall be done as per the statement attached with specification,The material IS Tested in GERI by
Executive Engineer Surat and Bill for the testing charges shall be paid by Executive Engineer,1% of the Amount put to
7 1% of the Construction Cost Shall be deducted from the bill Amount of the contract as per the Buildig and other
Construction works walfare cess at 1996(Labour and Employment Department Letter No CWA-2004-1831-M(3)Dated
9/12/2005 notification Of Labour & Employment department dt.03/01/2005 & Labou & Employment Department Letter
8 In Case of RCC items Where there is a change in Grade of Mix or Change as per Actual Mix design the cost of difference of
Cement Difference shall be deducted from the rate of original item at the rate of star rate mentioned in the tender.
9 Contractor are advised to visit site before loading tender rate.
10 Necessary wiring point and drainage point are installed at Site however any modification in electrical installation and
11 The Rates are inclusive of all the taxes (Excluding GST),Transport Charges,Octroi duty and storage Charges up to date.
12 The materials Covered for wiring should be got approved from the Engineer Incharge of the work.
13 GST and Income tax TDS will be deducted at a source while making payments of bills.
14 GST will be paid extra as per Govt. amendment.
15 The Materials on the work shall have to be used and carried out as specified in technical note.
I/We hereby Declare that I/we have Visited the site and fully Exquisite myself/ourselves with the local situation regarding
materials,Labour and other factors pertaininfg to work before submitting tender.
I/We hereby Declare that I/we have carefully Studied the condition of Contracts,Detailed Specification and other tender
Document of this work and agree to execute the same accordingly.
Signature of Bidder Deputy Executive Engineer
Dist ( R & B ) Sub-Division
Executive Engineer Executive Engineer
Vadodara Elect.(R&B) Divison Chhotaudepur ( R & B ) Division
Vadodara Chhotaudepur
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
E-Tender Notice.pdf
SBD Book Vet Polyclinic.pdf
BOQ - Vet Polyclinic.pdf
Specifications.pdf
Building-Specification Booklet.pdf
GRs.pdf
Drawings.pdf
Download all tender documents and submit your bid