Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.0 L+₹70,212 (4.59%)Rejected-AOC 32 LOOTERY MOHAL ORDERLY BAZAR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 W B | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-AOC High Rate | |
| 3 | L3₹16.0 L+₹73,877 (4.83%)Rejected-AOC | L3 | Rejected-AOC High Rate | |
| 4 | L4₹16.6 L+₹1.3 L (8.42%)Rejected-AOC | L4 | Rejected-AOC High Rate | |
| 5 | L5₹17.1 L+₹1.8 L (11.6%)Rejected-AOC 72 5 53 PIPE ROAD PO BARRACKPORE DIST 24 PARGANAS NORTH PIN 700120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L5 | Rejected-AOC High Rate |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
26 Sept 2020, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIR REPLACEMENT AND MAINTENANCE TO INTERNAL WIRING INCLUDING FITTING AND FIXTURE AT OTM MD ACCN 6 WING UNDER GE AF BARRACKPORE
2020_MES_365741_2
8244/BKP/AF OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
6 Wing AF Barrackpore
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
GE AF Barrackpore
₹30,000
Yes
19 Dec 2020
4 Sept 2020
28 Sept 2020
4 Sept 2020
26 Sept 2020
5 Sept 2020
Amount
Taking down carefully any type point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing ( Except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing.
M&L point wiring(surface type) for using 1.5 sqmm nominal cross sectional area copper conductor mutimultistranded ,PVC insulated unsheathed , FRLS cables in and including PVC casing and caping and fittings, including 1.2mm thick pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multi-multistranded copper conductor , FRLS, green PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. for one light/fan point cntrolled by one number one way switch complete all as specified and directed. (Make:- Finolex/KEI/Havells for copper cable and Make- Presto plast/Plaza for caping casing accessories)
All as per item No. 02 here-in-before but for Bell/Buzzer point controlled by one push button on independent board complete all as specified and directed.
All as per item No. 02 here-in-before but for one five pins 5 Amps switch socket outlet point on independent board complete all as specified and directed.
All as per item No. 02 here-in-before but for one five pins 5 Amps switch socket outlet point on same board complete all as specified and directed.
All as per item No. 02 here-in-before but for one light point controlled by two 2-way switches of 5 amps complete all as specified and directed.
All as per item No. 02 here-in-before but for 15 amps socket outlet with 4 Sqmm Copper incl 4 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
S & F switch piano one way 5/6 amps 240 volts complete all as specified and directed including taking down.
S & F Bell push AC, 50 Hz, 230 Volts, 5 amps complete all as specified including taking down.
S & F Bell Ding Dong AC, 230 Volts, Single pole complete all as specified including taking down.
S & F Switch socket combination two in one 5 pin 5 amps flush type complete all as specifeid including taking down.
S & F Switch socket combination 5 in 1, 5/16 amps flush type complete all as specifeid including taking down.
S & F switch piano flush type 5 amps but 2 way type complete all as specified including taking down.
M & L lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete including taking down. Make- Anchor/SSK/CONA
M & L Ceiling rose, 3 terminals/phase type, fabricated of PVC/Polycarbonate, isolated body complete including taking down. Make-Anchor/SSK/CONA
M&L for Delux stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc all as specified and directed including taking down.(Make- Anchor/Havells)
M & L for point wiring (surface type) with single core PVC insulated and unsheathed stranded copper conductor cable 1100 volts grade of FRLS size 1.5 sqmm in and including PVC caping casing and its accessories with one single core PVC insulated unsheated 1.5sqmm multistranded copper conductor as earth coninuity wire and connected to earth dolly including modular flush metal boxes , inner and outer modular cover platesof suitable size in recess to existing wall surface for one light / fan point controlled by one number one way switch complete all as specified and directed.(Make- Finolex/KEI/Havells for Copper cable and Make- Prestoplast/Plaza for conduit and accessories).
All as per item No. 17 here-in-before but for Bell/Buzzer point controlled by one push button on independent board complete all as specified and directed.
All as per item No. 17 here-in-before but for one five pins 5 Amps switch socket outlet point on independent board complete all as specified and directed.
All as per item No. 17 here-in-before but for one five pins 5 Amps switch socket outlet point on same board complete all as specified and directed.
All as per item No- 17 here in before but for one light point controlled by two way switches of 5 amps complete all as specified and directed.
All as per item No. 17 here-in-before but for 15 amps socket outlet with 4 Sqmm Copper including 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
M & L for point wiring (concealed type) in wall/roof/ceiling surface etc, suitable for modular plates including necessary cutting/chessing etc and making good the disturbed surface with single core , multistranded PVC insulated copper conductor cable 1100 volts grade fo FRLS size 1.5 sqmm in and including 20mm dia heavy duty rigid non metalic PVC conduit and conduit accessories with one single core PVC insulated unsheated 1.5sqmm multistranded copper conductor as earth coninuity wire and connected to earth dolly for fixing of modular flush box, fixed with brass scres and cap washers for one light/fan point controlled by one number one way switch complete all as specified and directed.(Note - Accessories like modular metal boxes, inner & outer plates will be paid and measured separately in respective items of schedule) (Make- Finolex/KEI/Havells for Copper cable and Make- Prestoplast/Plaza for conduit and accessories).
All as per item No. 23 here-in-before but for Bell/Buzzer point controlled by one push button on independent board complete all as specified and directed.
All as per item No. 23 here-in-before but for one five pins 5 Amps switch socket outlet point on independent board complete all as specified and directed.
All as per item No. 23 here-in-before but for one five pins 5 Amps switch socket outlet point on same board complete all as specified and directed.
All as per item No. 23 here-in-before but for one light point controlled by two 2-way switches of 5 amps complete all as specified and directed.
All as per item No. 23 here-in-before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
S & F modular switch 1 way 6 amps, 1 module complete all as directed by Engr-in-charge including taking down.
S & F modular switch 1 way 16 amps, 1 module complete all as directed by Engr-in-charge including taking down.
S & F modular switch 2 way 6 amps, 1 module complete all as directed by Engr-in-charge including taking down.
S & F modular bell push 6 amps, 1 module complete all as directed by Engr-in-charge including taking down.
S & F modular sockets 6 amps, 5 pin shuttered socket with two module complete all as directed by Engr-in-charge including taking down.
S & F modular sockets 6/16 amps, 3 pin combined shuttered socket two module complete all as directed by Engr-in-charge including taking down.
S & F modular fan regulator, step type, 120 watts, W-2 module complete all as directed by Engr-in-charge including taking down.
S & F modular white cover plate with frame, 4 module complete all as directed by Engr-in-charge including taking down.
S & F modular white cover plate with frame, 6 module complete all as directed by Engr-in-charge including taking down.
S & F modular white cover plate with frame, 8 module complete all as directed by Engr-in-charge including taking down.
S & F modular flush metal box 4 module complete all as directed by Engr-in-charge including taking down.
S & F modular flush metal box 6 module complete all as directed by Engr-in-charge including taking down.
S & F modular flush metal box 8 module complete all as directed by Engr-in-charge including taking down.
M&L for modular type Telephone socket including taking down. (Make: Carbtree, Roma, Legrand)
M&L for modular type TV socket including taking down (Make: Carbtree, Roma, legrand)
M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area,FRLS multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete surface/concealed including provision of 1X10.0 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete incl taking down old UNSV sub main all as specified.(Make- Finolex/KEI/Havells for Copper cable and Make- Prestoplast/Plaza for conduit and accessories). ( Note :-1. Extra length of cables/ wire required for connection to MCBs/DB's shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly 2. For Concealed wiring Cutting chases,chipping and plastering mesured and paid seperately under relevant items).
M&L for submain wiring comprising single core ,2 Runs of 6 sqmm nominal cross sectional area,FRLS multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete surface/concealed including provision of 1X6.0 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete incl taking down old UNSV sub main all as specified. (Make- Finolex/KEI/Havells for Copper cable and Make- Prestoplast/Plaza for conduit and accessories)( Note :-1. Extra length of cables/ wire required for connection to MCBs/DB's shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly 2. For Concealed wiring Cutting chases,chipping and plastering mesured and paid seperately under relevant items).
M & L cutting chases, chipping in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as directed by Engr-in-charge.
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete incl taking down UNSV DB and all as specified. (Make- Legrand Cat No- 507811 or equilavent of ABB/siemens)
Supply and fixing Modular type 25 Amps capacity starter type 2 module type for AC and Geyser points with complete and remove the UNSV and all as specified. Note: Modular plate and metal flush box shall me measured and paid separately under relevant items. (Make- Legrand Cat No- 673031 or equilavent of ABB/siemens)
Dismantling of existisng unserviceable MCB distribution board and S&F sheet metal enclosure TPN DB having facility to fix MCCB in incomer and MCBs in outgoing, TPN 4 ways, IP 43 with metal door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. make-Cat No 507745of Legrand or equivalent of ABB/Siemens
Dismantling of existisng unserviceable MCB distribution board and S&F sheet metal enclosure TPN DB having facility to fix MCCB in incomer and MCBs in outgoing, TPN 6 ways, IP 43 with metal door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. make-Cat No 507746 of Legrand or equivallent of ABB/Siemens
Dismantling of existisng unserviceable MCB distribution board and S&F sheet metal enclosure SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 12 ways, metal door IP-43 type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. make- Cat No 507612 of Legrand or equivalent of ABB/Siemens.
Dismantling of existisng unserviceable MCB distribution board and S&F sheet metal enclosure SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 08 ways, metal door IP-43 type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. make- Cat No 507611 of Legrand or equivalent of ABB/Siemens.
Dismantling of existisng unserviceable MCB distribution board and S&F sheet metal enclouser SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 4 ways, IP-43 type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. make- Cat No 507610 of Legrand or equivalent of ABB/Siemens.
M & L for MCCB of 4 pole type, 160 Amps current capacity, thermal magnetic type, 16 KA breaking capacity, 415 Volts complete including taking down old existing unserviceable all as directed by Engr-in-charge.(Make- Legrand Cat No- 420017 or equilavent of ABB/siemens)
S&F MCB SPN, 240 Volts, of 40 to 63 amps current rating, 10 KA breaking capacity Ç'series complete including takind down old UNSV all as directed by Engr-in-charge.(Make- Legrand Cat No- 408618 to 408620 or equilavent of ABB/siemens)
S&F MCB SPN, 240 Volts, of 32 amps current rating, 10 KA breaking capacity Ç'series complete including takind down old UNSV all as directed by Engr-in-charge.(Make- Legrand Cat No- 408617 or equilavent of ABB/siemens)
S&F MCB SP, 240 Volts, of 6 to 32 amps current rating, 10 KA breaking capacity Ç'series complete including takind down old UNSV all as directed by Engr-in-charge.(Make- Legrand Cat No- 408587 to 408595or equilavent of ABB/siemens)
S & F Energy efficient tube light fitting with LED batten type luminaire, extruded aluminium body with completely pre wired with driver internally fixed and decorative caps , 24W, 230V , with connector block, etc., complete with all accessories and connecting up with suitable size, 1.5 sqmm three core copper conductor flexible wire , screws , gutties etc.and removing the UNSV fitting and all as specified and directed. complete. Make-Jaquar Cat No LGLZ01X024XN or equivalent in Philips/Havells
S & F Energy efficient tube light fitting with LED batten type luminaire, extruded aluminium body with completely pre wired with driver internally fixed and decorative caps , 10 W, 230V , with connector blok, etc., complete with all accessories and connecting up with suitable size, 1.5 sqmm three core copper conductor flexible wire , screws , gutties etc.and removing the UNSV fitting and all as specified and directed. complete. Make-Jaquar Cat No LGLZ01X010XN or equivalent in Philips/Havells
M&L for the remove the existing 36/40W tube light fitting and fixing the Energy efficient LED tube rod 20 W , 230V , and necessary internally pre-wired with suitable size copper flexible wire and remove the UNSV choke and starter and including connecting up with suitable size, 1.5 sqmm three core copper conductor flexible wire , screws , gutties etc. all as specified and directed. complete. Make-Jaquar Cat No LTBL01X020XC or equivalent in Philips/Havells
M&L for the remove the existing 28W tube light fitting and fixing the Energy efficient LED tube rod 18 W , 230V , and necessary internally pre-wired with suitable size copper flexible wire and remove the UNSV choke and starter and including connecting up with suitable size, 1.5 sqmm three core copper conductor flexible wire , screws , gutties etc. all as specified and directed. complete. Make-Jaquar Cat No LTBL01X018XC or equivalent in Philips/Havells
M&L in replacement the existing PL-L and fitting RETRO PLL 20 W 4pin with very high efficency suited for installation in existing 36 W PL-L to give glare free light complete all as specified and directedMake-Jaquar Cat No LDZL01X020XC/ Philips/Havells
Supply and fixing Indoor LED recessed mounted fitting in diffused type 36 Watt 2ftx2ft complete with all accessories 3 core copper wire for connection, making good the disturbed ceiling and remove the UNSV fitting and all as specified and directed. Make-Jaquar Cat No LULT01S036XC or equivalent in Philips/Havells
S&F LED Flame proof light fittings fixtures CMRI certified luminaire single tube 1x16 W/20W 4 feet 230 V with bipin holder connector block etc complete with all acessories internally prewired connecting upto 3 core twisted flexible copper conductor cable of suitable size including removing of unserviceable fittings and making good disturbed surface complete all as specified and directed. Model: EXTN1LT8-16/20 of CG or equivallent in Philips/bajaj
S&F LED Flame proof light fittings fixtures CMRI certified luminaire single tube 2x16 W/20W 4 feet 230 V with bipin holder connector block etc complete with all acessories internally prewired connecting upto 3 core twisted flexible copper conductor cable of suitable size including removing of unserviceable fittings and making good disturbed surface complete all as specified and directed. Model: EXTN2LT8-16/20 of CG or equivallent in Philips/bajaj
M&L for PVC insulated Single core 1.5 sqmm 3 core multi strand copper conductor for connection of security light from Junction Box to security light all complete all as specified and as directed including taking down.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI strip upto 7.5m including testing consider in this item).
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or DB's/Indoor type LT PBs or any other indicated situation for loop earthing etc. 32X6 mm galvanised iron or steel strip all as specified and directed.
Earthing complete with GI earth plate electrode 600x 600 x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 m below ground level with the top edge not less than 1.5 m below ground level connected of GI earth wire of 4 sqmm means of bolts, nuts, check nuts and washers and earth strip protected by 40 mm dia GI pipe medium grade and connected to main distribution board/earthing test point incl necessary excavation and RCC M-20 mix, watering pipe funnel, PCC pit complete and frame work complete as shown in electrical plate No.3 of MES Sch `A' Part I complete all as directed by Engineer-in-Charge including taking down.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or DB's/Indoor type LT PBs or any other indicated situation for loop earthing etc. 4mm dia galvanised iron or steel wire all as specified and directed.
S&F Thermoplastic Polystyrene of IP 65, single phase metering cover wall mounted of size 217x253x115 mm with transparent glass and necessary fixing nut ,bolts and clamp for installations of single phase energy meters.Quoted rate includes connection of respective energy meters at specific locations complete all as specified and directed by Engr-In-Charge including taking down. Make- Hensel of RAL 7035
Das and Brothers
BHAUMIK CONSTRUCTION
KAZI ENTERPRISE
PIONEER
BOSE ENTERPRISE INDEX NO.E 106 2010 BKP
VIVEKANANDA TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .