Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.1 CrAccepted-AOC OLYMPIA PLATINA PLOT NO 33B SOUTH PHASE GUINDY CHENNAI 600032 | CHENNAI | CHENNAI | TAMIL NADU | 600032 | ₹2.1 Cr Quoted ₹2.2 Cr | 1 | Accepted-AOC L1 bidder |
| 2 | 2₹2.4 Cr+₹23.1 L (10.7%)Rejected-AOC NO 523 3 AVINASHI ROAD NAVA INDIA COIMBATORE TAMIL NADU 641028 | COIMBATORE | TAMIL NADU | 641028 | ₹2.4 Cr+₹23.1 L (10.7%) | 2 | Rejected-AOC L2 bidder |
| 3 | Rejected-Technical 5C OXFORD BUSINESS CENTER SREEKANDATH ROAD RAVIPURAM ERNAKULAM KERALA 682016 | ERNAKULAM | KERALA | 682016 | - | - | Rejected-Technical Rejected as the firm does not meet the PQ criteria |
Tender Value
₹1.9 Cr
EMD Value
₹50,000
Closing Date
17 Apr 2023, 5:00 pmClosed
Chief Engineer (IT,CR and CAPs)
Chief Engineer (IT,CR and CAPs), 8th Floor, Vydyuthi Bhavanam, Pattom, Thiruvananthapuram - 695004
Providing comprehensive Facility Management Services (FMS) with Annual Maintenance Contract (AMC) for the physical infrastructure of the Data Centre and Disaster Recovery Centre of KSEBL
2023_KSEB_569233_1
CE(ITCR CAPS)/ITCSD/DCDR PhyInfra/13/dtd 25.3.23
Open Tender
Miscellaneous Works
Item Wise
1095 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,900
Yes
₹50,000
Yes
31 Oct 2023
27 Mar 2023
19 Apr 2023
27 Mar 2023
17 Apr 2023
29 Mar 2023
27 Mar 2023 - 30 Mar 2023
FMS for the Data Centre for 3 years
FMS Charges for Physical Infrastructure of Data Centre for the 1st Year
FMS Charges for Physical Infrastructure of Data Centre for the 2nd Year
FMS Charges for Physical Infrastructure of Data Centre for the 3rd Year
FMS for the DR Centre for 2 years
FMS Charges for Physical Infrastructure of DR Centre for the 1st Year
FMS Charges for Physical Infrastructure of DR Centre for the 2nd Year
Description of Work / Item(s)
Comprehensive AMC for the following Data Centre physical infrastructure componets for a period of 3 years.
250 kVA Diesel Generator Set
DG Set AMF Panel
Comfort Air Condition (CAC)- 10TR VRF Unit with indoor units as mentioned in Annexure-1 table -6 of the tender document
Comfort Air Condition (CAC)- 12TR VRF Unit with indoor units as mentioned in Annexure-1 table -6 of the tender document
Comfort Air Condition (CAC)- 16TR VRF Unit with indoor units as mentioned in Annexure-1 table -6 of the tender document
Main LT Panel with 2 Incomers and 1 Bus Cupler
Automatic Fire Supression system along with its accessories and power supply.
Fire Detection system along with its accessories and power supply.
Smoke Detection system (VASDA) along with its accessories and power supply
Automatic water leak detection system along with its accessories.
Comprehensive AMC for the following DR Centre physical infrastructure componets for a period of 2 years.
320 kVA Diesel Generator Set with ATS panel
Comfort Air Condtion (CAC)- 8.5 TR and its indoor Split Air Condtion Units (2 Nos of 1.5 TR).
Main LT Panel with 4 Incomers and 1 Bus Cupler
CCTV based video surveillance system along with its accessories and power supply
Fire suppression system along with its accessories and power supply.
Fire Detection system along with its accessories and power supply.
Smoke Detection system (VESDA) along with its accessories and power supply
Security , access control system and public address system along with its accessories and power supply.
Automatic water leak detection system along with its accessories.
Building Management System along with its accessories and power supply
Description of Work / Item(s)
CCTV Supply, Installation, testing & commissioning of new CCTV cameras in place of the existing Dome and PTZ cameras with the following components and specifications.
IP based Dome camera :Max. 2megapixel (1920 x 1080) resolution, 2.8mm lens Max. 30fps@all resolutions (H.264) H.264, MJPEG codec supported, Multiple streaming Day & Night (ICR), WDR (120dB) Tampering, Motion detection microSD/SDHC/SDXC memory slot (Max. 32GB), PoE Hallway view, IR viewable length 30m IP66 and IK10
IP based Dome camera :Max. 2megapixel (1920 x 1080) resolution 3.2-10mm lens Max. 30fps@all resolutions (H.264) H.264, MJPEG codec supported, Multiple streaming Day & Night (ICR), WDR (120dB) Tampering, Motion detection microSD/SDHC/SDXC memory slot (Max. 32GB), PoE Hallway view,IP 66 , IK10 IR viewable length 30m
NVR: 32 CH Network Video Recorder, Up to 32CH 32 megapixel supported H.265, H.264, MJPEG codec supported 400Mbps network camera recording Max. 8HDDs, e-SATA storage supported . NVR must be loaded with 32 TB Usable with Raid 5 configuration .Hard disk should be 7200 RPM HDMI Supported Raid 5/6 Support . With N+1 redundency Support. Digital Video Management Software for seamless integration wih third party application for unlimited Management Server/Recording server/Client PC for centralise monitoring, recording and video management with 32 Camera licenses and with 5 client licenses.
32'' LED Monitor
Desktop PC Intel Core i5 12th Gen CPU, 16GB RAM, 512GB SSD, 21” or above LED HD Display, USB Keyboard & mouse, Gigabit Ethernet integrated, Windows 10 Pro OS, 3 year warranty
48 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); 250 W POE Budjet
Control cables,conduits and accessorie required for the required for the installation of thencameras
ACCESS CONTROL SYSTEM Supply, Installation, testing & commissioning of new Access Control system in place of the existing one with the following components and specifications.
IP Controller for one or 2 doors (depending on configuration) 4 Monitored or Unmonitored Inputs 2 Relay Outputs 4 Open-collector Outputs 1 general-purpose FLN bus to connect to IPM, OPM and 8IO devices Capacity for 500,000 users Maximum 5 cards per user offline event buffer with up to 200,000 events Anti-passback -Power supply unit with 7AH Battery
Fingerprint Biometric Reader with smart card reader
iclass Smart Card Reader
Smart Card
Electromagnetic lock - 600 lbs with ZL / UL bracket, as required - Single Leaf Voltage Input : 12 VDC / 24 VDC Current Draw : 12V / 500mA ; 24V / 250mA (±5%) Holding Force : Up to 600 lbs (272 kg)
Electromagnetic lock - 600 lbs with ZL / UL bracket, as required - Double Leaf Voltage Input : 12 VDC / 24 VDC Current Draw : 12V / 500mA ; 24V / 250mA (±5%) Holding Force : Up to 600 lbs (272 kg)
Resettable Emergency Release Switch
Stainless Steel Exit Switch
Magnetic Contact
Access Control Software Anti-passback 3 wrong PIN mode Time scheduling Manual system override capabilities Enrolment reader support Multi-user, multi-tasking environment Note: The server for loading the software will be provided by KSEBL.
Desktop PC Intel Core i5 12th Gen CPU, 16GB RAM, 512GB SSD, 21” or above LED HD Display, USB Keyboard & mouse, Gigabit Ethernet integrated, Windows 10 Pro OS, 3 year warranty
Server Operating System License.
Cable/Strand/PVC pipes etc required for installation and commissioning of the access control system
Integrated Software for BMS & FAS( Graphic Software)
Building management software shall include alarm handling, scheduling, trending, reporting engine, database system, system activity log, historical data management, real time vector graphics, system backup and restore, HTML based documentation and help .Grahical user interface based software as per IO summary, 1 Client station. The software should intergrate BMS ,CCTV and Access Control system . The software should include license for intergration of 32 camera and 16 door
Third Party Integration: The Protocol Integrator/ Convertor shall be Capable to Integrate Open protocol systems on BACnet /Modbus/LONWORKS/M-Bus/J-Bus Protocol Made avaliable on IP, or on serial RS 485 / 232 interface. (Separate Integrator for each system)
Integrator for PAC for Server room (25 Soft Points considered for each PAC Unit ) on MODBUS RTU PROTOCOL.
Integrator for ENEGEY METERS(15Soft Points considered for each Energy Meters ) on MODBUS RTU PROTOCOL.
Integrator for UPS ( 25 Soft Points considered for each UPS ) on MODBUS RTU PROTOCOL.
Integrator for DG ( 25 Soft Points considered for each DG ) on MODBUS RTU PROTOCOL.
Integrator for Fire ( 60 Soft Points considered for each Panel ) on MODBUS RTU PROTOCOL.
Direct Digital Controllers: BACnet/IP Bacnet/IP - 32 Bit DDC Controllers with I/O points as per enclosed IO List, inbuilt real time clock, Battery backup. The controllers shall be capable of standalone operation with real time clock and historical database. The DDC's shall be capable of peer to peer communication without help of system interface controller or PC. The DDCs shall be with suitable IP 54 enclosure complete with all wiring and accessories . BTL Approved . Each DDC Should have minimum 20MB Memory Space. (DDC BMS Room)
Room Temerature and RH sensor with Display
Desktop PC Intel Core i7 12th Gen CPU, 32 GB RAM, 512GB SSD, 21” or above LED HD Display, 4 GB Graphics Card, USB Keyboard & mouse, Gigabit Ethernet integrated, Latest Windows Professional OS, 3 year warranty
Control cables and accessories required for the insatllation and commissioning of the BMS system
Description of Work / Item(s)
Top Containment- Installing Top Containment Using 25mm x 50mm hollow pipes with 25mm x 25mm 'L' section black matt powder coating with 3 mm Polycarbonate and its accessories as per specification mentioned in Detailed scope of work Section 6.1
Double leaf Sliding Door with Door Closer-Double leaf sliding door made of 4mm thick polycarbonate solid sheet with all side frames made of aluminium and powder coated black matt finish. (1200 W x 2100 H) and its accessories as per specification mentioned in Detailed scope of work Section 6.1
Description of Work / Item(s)
Extended Warranty for the CCTV system and its accessories as mentined in the specification of the tender document for the 4th year
Extended Warranty for the CCTV system and its accessories as mentined in the specification of the tender document for the 5th year
Extended Warranty for the Access Control System and its accessories as mentined in the specification of the tender document for the 4th year
Extended Warranty for the Access Control System and its accessories as mentined in the specification of the tender document for the 5th year
Extended Warranty for the BMS System and its accessories as mentined in the specification of the tender document for the 4th year
Extended Warranty for the BMS System and its accessories as mentined in the specification of the tender document for the 5th year
Description of Work / Item(s)
Amount
Total Amount (BoQ1+BoQ2+BoQ3+ BoQ4+BoQ5)
Netcon Technologies India Pvt Ltd
Netcon Technologies India Pvt Ltd
Vertiv Energy Private Limited
Vertiv Energy Private Limited
Netcon Technologies India Pvt Ltd
Netcon Technologies India Pvt Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .