Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC BIG NO 7 104 MANAKKATTU VAYANAKOM NJAKKAL POST KRISHNAPURAM VIA OACHIRA PANCHAYAT ALAPPUZHA KOLLAM DISTRICT KERALA STATE PIN 690 533 | ALAPPUZHA | KOLLAM | KERALA | 690533 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.4 L+₹93,617 (4.17%)Rejected-AOC 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹27.6 L+₹5.1 L (22.7%)Rejected-AOC | L3 | Rejected-AOC Not Being L1 | |
| 4 | L4₹27.6 L+₹5.1 L (22.9%)Rejected-AOC 22 1755A KANNANKATTU TEMPLE ROAD EDAKOCHI KOCHI 682010 ERNAKULAM KERALA 682010 | ERNAKULAM | KERALA | 682010 | L4 | Rejected-AOC Not Being L1 | |
| 5 | L5₹29.4 L+₹6.9 L (30.8%)Rejected-AOC | L5 | Rejected-AOC Not Being L1 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
14 Dec 2023, 6:00 pmClosed
Yogendra Kumar GE
GE(I)(CG)KOCHI BUILDING NO.22/2614, OPP. SANTHOM CHURCH MUNDAMVELI POST RAMESWARAM KOCHI-682 507
DAY TO DAY MAINT OR EPAIR TO EXTERNAL ELECTRIC SUPPLY, DG SETS, UG HT OR LT CABLES, MAINTENANCE OF DISTRIBUTION TRANSFORMERS, LT OR HT SWITCHGEAR AND PANELS, LIGHTING PROTECTION SYSTEM, SECURITY OR STREET LIGHTS AT CGDHQ-4 AND CGRA RAMESWARAM
2023_MES_628550_1
8902/E8
Open Tender
Civil Works
Works
365 days
FORT KOCHI
As per Tender documents
8 documents required · 8 mandatory
₹500
GE(I)(CG)KOCHI
₹56,000
Yes
24 Feb 2024
16 Nov 2023
21 Dec 2023
16 Nov 2023
14 Dec 2023
30 Nov 2023
16 Nov 2023 - 23 Nov 2023
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and as directed.
Material and labour for providing dry screened river sand as in sand cushioning to under ground cable including punning down of sand by layer complete all as specified and as directed. NOTE: Punned thickness shall be measured and paid.
Supply and laying cable protection cover un- reinforced precast concrete cable covers class LV, type-1 flat size 250mmx150mmx40mm for cable protection complete all as specified laid perpendicular to cable as per directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 185 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 95 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 70 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 50 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 25 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm with all accessories complete all as specified and directed.
Supply and fix cable end for 1.1KV grade cable for indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor of size 70 Sqmm to 95 Sqmm all as specified and as directed.
Supply and fix cable end for 1.1KV grade cable for indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor of size 120 Sqmm to 185 Sqmm all as specified and as directed.
Supply & Fix 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
Material and Labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
Supply & Fix in replacement of MCCB 63 Amps,4 pole, 415 Volt adjustable type with breaking capacity 16 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply & Fix in replacement of MCCB 100 Amps,4 pole, 415 Volt adjustable type with breaking capacity 16 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply & Fix in replacement of MCCB 125 Amps,4 pole, 415 Volt adjustable type with breaking capacity 25 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply & Fix in replacement of MCCB 160 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply & Fix in replacement of MCCB 200 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply & Fix in replacement of MCCB 250 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply & Fix in replacement of MCCB 400 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply and fix in replacement of GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit complete all as specified and directed.
M & L for conducting oil filtration by stream line / Vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer incl routine testing after filtration for any capacity of transformers/AVR/CT/PT units all as directed. (Note : The contractor shall change the filter assy before starting the filtration of transformer / AVR in presence of Engr In charge) Note:- (i) Test results before and after filteration shall be submitted on completion in tripilicate. (ii) Necessary electric for filtration plant shall be issued by department,required length of cable/switch etc shall be arranged by the contractor.
Supply and filling of fresh transformer power oil of BDV not less than 60 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration or for replacement complete including removing of old unservicable transformer oil into conservator tank/body tank of transformer as per IS-335 2018 complete all as specified and diredcted. Note:- 1. The taransformer oil for topping up shall be of Di-electric strength more than 60 KV for 1 miniute at 2.5 mm gap between the two electrodes. 2. Oil shall be supplied at site in sealed barrel.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100 KVA to 500 KVA out door type transformer including taking down u/s from the transformer complete all as specified.
Dismantling old and burntout PT unit 11000/110 volts draw out type epoxy resin cast type taking out contact with lead and bushing from the bus bar and PT, replacing by new one of same model suitable for 11 KV, 630 Amp, 350 MVA VCB incl testing on completion all as directed
Supply, fixing and laying in repair synthetic rubber insulated mat 2.5 mm thick for voltage upto 11 kv (size 2x1m) as per IS-15652-2006 (superseeding IS-5424) suitable for electrical shock safety complete all as specified and directed
Supply and fixing temperature gauge meter suitable for 100KVA to 500KVA outdoor type transformers including taking down unserviceable gauge meter.
M & L for painting the outer surface of the transformer with two coat of greenovoc water based polymer paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 100 KVA to 600 KVA (Indoor/outdoor type).
Material and labour in repair for replacement of brass terminal rod with nuts, bolts washers & bushings suitable for HT side of the transformer of and capacity from 100 KVA to 500 KVA complete all as specified and directed
Material and labour in repair for replacement of brass terminal rod with nuts, bolts washers & bushings suitable for LT side of the transformer of and capacity from 100 KVA to 500 KVA complete all as specified and directed
M&L for replacement off load tap changer for distribution transformer of capacity from 200-500 KVA, comply with IEC 214:1976 and BS: 4571:1970 and shall be suitable for power flow in both the directions. complete all as specified and directed
Supply and fix Plates confirm to FE-410W (GDE-E -250 quality-A) (Plain or chequired) channels, square cut or notched(ordinary and counter sunk with out any attachment complete all as specified and directed.
S & F in repairs transmission class type drop out fuses 11000 volts rating 25-50 amps,outdoor type complete.
Taking down Triple pole mechanism complete from the site, supply and install mechanically operated, mounted on insulator and steel frame,with opertaing mechanism worked from ground level with GI pipe medium grade, for current rating upto 200 Amps and Air break (switch) insulator suitable for HT 11 KV out door type all as directed. Make : Atlas/GEC/Pactil or equivalent
S & F in repairs including testing of air break switch assembly out door type 11 KV supply, 200 Amp incl mounting bracket & post insulator comlete all as directed. Make : Atlas/GEC/Pactil or equivalent
S & F in repairs lightining arrester high tension,expulsion type,transmission class,discharge capacity 65 kilo ams suitable for 11000 Volt supply complete with all fitting suitable discharge capacity including necessary fixing arrangements made out of MS angle/flats,nuts and bolts etc complete all as specified and directed
M & L in repair of Cross arms, bracings, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shapes size as indicated or directed and inclusive of one primer coat, and one under coat and one finished coat of aluminium paint incl dismantling of old unsv complete all as specified.
M & L for carrying out primary & secondary injection test of 11 KV indoor /outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning incl submitting the test report all as directed by Engr in charge. (Note : PIT/SIT for VCB will be carried out and each primary & secondary injection test will be measured as one unit and paid)
M & L for servicing of VCB 11 KV, 630 A , 25 KA, 350 MVA / bus coupler by dismantling cleaning greasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required reassembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning all as directed. Make : ABB /Sneider/L&T. Note : New spares will be measured and paid separately under relavent item of this schedule.
Supply only Vacum Interrupter 12kV (spares) for outdoor/indoor VCB 11 KV, 630 A , 50 KA, 350 MVA as approved by GE agianst Item Ser No. 42. Make : ABB/L&T/Seimens
Supply only Common Truck/ Rack In-Out Machanism (spares) for outdoor/indoor VCB 11 KV, 630 A , 50 KA, 350 MVA as approved by GE agianst Item Ser No. 42. Make : ABB/L&T/Seimens
Supply only VCB VD4 Pole Assembly (spares) for outdoor/indoor VCB 11 KV, 630 A , 50 KA, 350 MVA as approved by GE agianst Item Ser No. 42. Make : ABB/L&T/Seimens
Supply only Spring Charging Mechanism (spares) for outdoor/indoor VCB 11 KV, 630 A , 50 KA, 350 MVA as approved by GE agianst Item Ser No. 42. Make : ABB/L&T/Seimens
Supply only VCB Spring Charging Mechanism (spares) for outdoor/indoor VCB 11 KV, 630 A , 50 KA, 350 MVA as approved by GE agianst Item Ser No. 42. Make : ABB/L&T/Seimens
M & L for servicing of OCB 11 KV, 630 A , 25 KA, 350 MVA / bus coupler by dismantling cleaning greasing the complete OCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required reassembling the OCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning all as directed. Make : Crompton Greves/ABB /Sneider/L&T. Note : New spares will be measured and paid separately under relavent item of this schedule.
Supply only Cluster Contacts for OCB, 11KV (spares) for outdoor/indoor OCB 11 KV, 630 A , 50 KA, 350 MVA as approved by GE agianst Item Ser No. 44. Make : ABB/L&T/Seimens
Supply only 11KV OCB Brass Fixed Moving Contacts (spares) for outdoor/indoor OCB 11 KV, 630 A , 50 KA, 350 MVA as approved by GE agianst Item Ser No. 44. Make : ABB/L&T/Seimens
Supply only Brass Copper Contacts for OCB (spares) for outdoor/indoor OCB 11 KV, 630 A , 50 KA, 350 MVA as approved by GE agianst Item Ser No. 44. Make : ABB/L&T/Seimens
Supply only Trip Coils Closing Coils for OCB Breaker (spares) for outdoor/indoor OCB 11 KV, 630 A , 50 KA, 350 MVA as approved by GE agianst Item Ser No. 44. Make : ABB/L&T/Seimens
Supply only Oil Circuit Breaker starter (spares) for outdoor/indoor OCB 11 KV, 630 A , 50 KA, 350 MVA as approved by GE agianst Item Ser No. 44. Make : ABB/L&T/Seimens
M & L for servicing of LT panel boards/Automatic synchronising panel of any type, capacity and sizes by dismantling/opening the LT panel by dissconnecting all electrical connection and cleaning, greasing, painting, repairing the complete LT panel with attached relays, bus bar, CT/PT etc. and insulation testing, setting the contact gap by measuring as required, repairing/renewel of the hinges, locking arrrangement of the panel, painting of LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun,reassembling the LT panel and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning all as directed. (Note : 1. Petty/small spares required for the smooth functioning of the panel deemed to be included in the quotated rate. 2. Only new major spares shall be measured and paid separately under relavent item of this schedule) and the same as per the direction given by Engr-in -charge.
Supply only On Load switch fuse change over250Amp, 4pole (spares) for outdoor/indoor LT panel boards/Automatic synchronising panel as approved by GE agianst Item Ser No 46 all as specified and as directed.
Supply only 2NO +2NC 185A Double pole power contactor (spares) for outdoor/indoor LT panel boards/Automatic synchronising panel as approved by GE agianst Item Ser No 46 all as specified and as directed.
Taking down existing street light fittings fitted at any type of pole and Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete including connection twin core copper wire drawn through rigid PVC pipe not less than 20 mm dia from junction box to light fitting complete all as specified and directed. Make: Havells Cat part No. ENDURASUNDOWNSL60WLED765PASYBOTG or equivalent in Philips/Bajaj/Surya. Note :-1. Rate of the LED light fitting includes LED light fitting, conncection twin core copper wire of suitable size, rigid PVC pipe not less than 20 mm dia and all accessories required to fit the light at any type of pole. 2. GI bracket is not included in the quotated rate.
Supply and errect steel tubular swaged poles 410 SP – 55, 11 meter long, conforming to IS 2713-1980 and MS tubing as per IS-1161, brought in two pieces welded at site complete with cast iron base plate, finial taper plug, bolts, nuts and screws including two coat of aluminium paint over a coat of primer all as specified and as directed.
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete including necessary form work complete all as specified and as directed.
Material and Labour for Plain Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in foundations filling and mass concrete for stays foundation/ filling and mass concrete and removing and depositing surplus concrete to clear off the site complete all as specified and as directed.
Material and labour for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Material and labour for Loose filling with aggregates of gauge 40 to 80mm in sub-station yard, all as specified and as directed.
M & L for preparation of old surface, cleaning the surface of the Steel tubular swaged poles 11 Mtr long pole structures above the ground level incl coping area and painting with two coats of aluminium paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified and directed by Engr-in charge
Taking down existing unserviceable terminal box and S & F hot pressed moulded SMC junction/terminal box of internal diemension of 200x140x95 mm and hinged door,including 01 No 4 way connector 415 Volt, 63 Amp, made out of polycorbanate or bakelite and 1 No. MCB of 6 Amp with DIN bar,drilling holes for cable connections connecting incomming and or out going cables by providing cable luggs/glands of suitable size fixed on pole by means of clamps made out of MS flat iron of suitable sizes,duly painted with two coats of red oxide zince primer complete all as specifiedand directed. Make : Sintex/L&T/Havells or equivalent
S&F in repair cable route indicator made out of 50x6 mm angle iron 60 mm long embedded in PCC block of suitable size with moulded letter HT cable or LT cable suitable inscribed on cast iron circular plate 8 mm thick 100 mm dia complete including PCC 1:3:6 type C-2(using 40 mm graded aggregate block of 150x150x150 mm size ) all as specified and directed by Engineer - in - Charge.
M & L for removing vegitation, grass, scrubs and bushes growing in Sub station yard along with fancing by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately.
Supply and fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as directed having front area 1.20 Square Metre complete all as specified and directed.
M & L for servicing/repair of the Solar street light fittings fitted at pole by taking down LED light fitting and solar plate fitted at the pole, cleaning of the solar plate, repairing /replacing the defective parts, charging the battery etc. for making the solar light fitting functional complete all as specified and directed. Note :-1. Rate of each job does not include the cost of solar plate and battery. If the same is found defective will be measured and paid separately. 2. Rate of the job inclusive of the cost of replacement minor parts such as cable lugs, cable glands, connection wire, MCB, DB's etc required for the smooth functioning of solar street light.
Periodical maintenance / servicing of Diesel Generator set of 75 KVA capacity installed at CG DHQ-4, Fort Kochi for smooth operation of generator sets and ensuring the serviceablity by renewing the defective spares, settings/ caliberation etc for the following capacity Model/ Make by carrying out inspection /work by an authorised dealer of OEM complete all as specified and directed:- (DG set make:- Engine -Ashok Leyland, Alternator - Kirloskar) Engine Servicing /Gen overhauling :- (a) Checking the lubricant oil, topping up & changing filters if required (b) Checking the lubricant level and replacing if required (c) Checking of alternater, battery charging, fanbelt and adjusting/renewing if required
(d) Checking/adjusting of sensers / controls of the Engine (e) Cleaning the cylinder head, lever, lube oil, gudgen pins etc (f) Draining fuel filter bowels to remove water/sediments and refixing with new gaskets after cleaning/ renewing the filters (g) Checking and tightening all external fasteners and arresting all leakages by renewing deffective nuts bolts washers etc whereever required (h) Checking and arresting leakages by tightening all lube and fuel/ hose connections by renewing defective washers (i) Checking of air filters subject to 250 hrs running or six months whichever is earliest for renewal (j) Cleaning of air filter assembly (k) Renewal of all external rubber parts including radiator hose pipes, sir clips/clamps with nuts bolts etc (l) Arresting all water /lubricant/fuel leakages (m) Checking of all engine parameters and ensuring trouble free performance
(n) Removing US spares and fixing of new spares including testing etc Alternator Servicing :- (a) Checking lubricant in the bearings (b) Checking electrical excitation system and repairing if required (c) Checking alternator insulation values and tightning the electrical connections etc (d) Checking circuits of various connections (e) Cleaning the slip rings/brushes etc (f ) Removing US spares and fixing of new spares including testing etc AMF Panel Servicing :- (a) AMF Panel will be maintained for good operation with the existing components. Any components found defective will be renewed and paid under relevant item of schedule. (b) Removing US spares and fixing of new spares including testing etc
Notes: 1. (a) Spares, lubricant, coolant etc required for engine, main alternator & AMF panel will be measured and paid seperately. (b) Charges for Major repairs / top overhauling of engine, rewinding of alternator, alternator major overhauling due to normal wear & tear will be out of scope of the work. However the damages caused due to negligence of the contractor will be made good without any extra cost by the contractor. Cost of minor spares required for proper operation of DG set and Control panel shall be deemed to be included in the rate quoted. (c) U/s spares shall be measured under Schedule of Credit 2. HPP (N) required at the time of mainteance/testing will be issued by MES. 3. Labour charges for dismantling/taking down and replacement/fixing new parts as and when required.
Same as per item No. 60 but for 160 KVA DG set Greaves Power Location:- CGRA Rameswaram Power House – 02 Nos
Same as per item No. 60 but for 10 KVA DG set Greaves Power Location:- Main office, GE(I)(CG) Kochi
Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for Greaves Power cotton curve of capacity 75 to 250 KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hz complete all as directed by Engr-in-Charge. Make : Kirloskar / Cummins/Crompton Greaves.
Supply only lubrication oil filter element with 'O' ring of Make MICO / Kirloskar / Ruston/Greaves Powe cotton as required at site for 75 KVA capacities of DG Sets all as directed by Engineer-in-Charge.
Supply only lubrication oil filter element with 'O' ring of Make MICO / Kirloskar / Ruston/Greaves Powe cotton as required at site for 160 KVA capacities of DG Sets all as directed by Engineer-in-Charge.
Supply only lubrication oil filter element with 'O' ring of Make MICO / Kirloskar / Ruston/Greaves Powe cotton as required at site for 10 KVA capacities of DG Sets all as directed by Engineer-in-Charge.
Supply only fuel filter element with 'O' ring of Make MICO / Kirloskar / Ruston / Greaves Power cotton as required at site for 75 KVA capacities of DG Sets all as directed by Engineer-in-Charge.
Supply only fuel filter element with 'O' ring of Make MICO / Kirloskar / Ruston / Greaves Power cotton as required at site for 160 KVA capacities of DG Sets all as directed by Engineer-in-Charge.
Supply only fuel filter element with 'O' ring of Make MICO / Kirloskar / Ruston / Greaves Power cotton as required at site for 10 KVA capacities of DG Sets all as directed by Engineer-in-Charge.
Supply only Air filter element inner and outer as required at site with 'O' ring of Make MICO / Kirloskar / Ruston / Greaves Power cotton as required at site for 75 KVA capacities of DG Sets all as directed by Engr-in-Charge.
Supply only Air filter element inner and outer as required at site with 'O' ring of Make MICO / Kirloskar / Ruston / Greaves Power cotton as required at site for 160 KVA capacities of DG Sets all as directed by Engr-in-Charge.
Supply only Air filter element inner and outer as required at site with 'O' ring of Make MICO / Kirloskar / Ruston / Greaves Power cotton as required at site for 10 KVA capacities of DG Sets all as directed by Engr-in-Charge.
Supply and fix in repair of to Radiator of DG Set of rating 75 KVA Capacity complete all as specified and as directed.
Supply and fix in repair of to Radiator of DG Set of rating 160 KVA Capacity complete all as specified and as directed.
Supply only speed sensor for 160 KVA capacity DG Set complete all as specified and as directed.
Supply only Lube oil pressure sensor for 75 KVA Dg Set complete all as specified and directed.
Supply only fuel flow valve for 160 KVA capacity DG Set complete all as specified and directed
Supply only fuel flow valve for 75 KVA capacity DG Set complete all as specified and directed
Removing the old silencer and replace with Retrofitted Emission Control Equipment / Devices (RECD) having a minimum specified Particulate Matter (PM) capturing efficiency of 70%. type approved by one of the five Central Pollution Control Board (CPCB) recognized labs. The emission limits and parameters for DG sets shall be as per CPCB-II norms. The back pressure shall be maintained within prescribed limit by the manufacturer. There should not be any backflow from RECD to engine exhaust system complete all as specified and directed.
Removing the old silencer and replace with Retrofitted Emission Control Equipment / Devices (RECD) of 75KVA DG set having a minimum specified Particulate Matter (PM) capturing efficiency of 70%. type approved by one of the five Central Pollution Control Board (CPCB) recognized labs. The emission limits and parameters for DG sets shall be as per CPCB-II norms. The back pressure shall be maintained within prescribed limit by the manufacturer. There should not be any backflow from RECD to engine exhaust system complete all as specified and directed.
Supply only Speedo meter cable including outer and inner cable complete all as specified and directed.
Supply only in repairs fuel pump kit for DG set 110 KVA capacity all as specified and as directed.
Supply only in repairs fuel pump kit for DG set 160 KVA capacity all as specified and as directed.
Supply only AMF relay and replacement of micropocessor 12V/24V complete all as specified and directed.
Supply only 'V' Belts/pump 'V' belts dynamo 'V' belts for 75 KVA DG set
Supply only 'V' Belts/pump 'V' belts dynamo 'V' belts for 160 KVA DG set
Supply only Flexible over flow pipe steel armoured flexible with suitable end sockets of size 15 mm dia of suitable length and size complete all as specified and directed.
Supply only multi-grade 15W40 lubricating oil for DG Sets as per manufacturer’s recommendations, complete all as specified and directed. Make- IOC, Castrol, Hindustan Petroleum
M&L for distilled water to be filled in batteries all as directed by Engr-in-Charge
Supply only coolant for radiator as per manufacturer’s recommendations, complete all as specified and directed. Make- Castrol, Servo, Cummins
Taking down old Unserviceable self motor of capacity 62.5 KVA to 200 KVA and servcing including replacment of Unserviceable spare aprts Brush, holder, solonoid switch, armature bush, filed coil complete all as specified and directed.
Disconnecting the existing battery of capacity 12V / 180 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new Electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function all as directed by Engineer-in-charge.
Repairs to 24 V battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly, assembly reaffixing to the engine and testing for satisfactory charging of battery all as directed by Engineer-in-Charge.
All as per item No 93 above but of 12 V battery charging alternator complete all as specified and directed.
Supply and fixing anti vibration pads for DG set of capacity 10 KVA complete all as specified and directed.
Supply and fixing anti vibration pads for DG set of capacity 75 KVA complete all as specified and directed.
Repairs to 12/24V self starter by removing, dismantling and taking it to authorised workshop and replacing unserviceable Armature including field coil tapping re-fixing to the engine testing for satisfactory function all as directed by Engineer-in-Charge
Painting of 160 KVA capacity DG set installed at CGRA Rameswaram after preparing the external surface apply one coat of spray painting by superior quality enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed
Painting of 75 KVA capacity DG set installed at CGDHQ-4 after preparing the external surface apply one coat of spray painting by superior quality enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed
Painting of 10 KVA capacity DG set installed at GE Office after preparing the external surface apply one coat of spray painting by superior quality enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed
Periodical maintenance / servicing of Electrical Incinerator of 20 KG/Hr capacity installed at CG DHQ-4, Fort Kochi for smooth operation by dismantling/opening of the incinerator removing defective parts, replace them with the new parts, cleaning of the entire incinerator from inside, repair to blower fan, MCB, tightening all electrical connection, replace cable lugs and cable gland with new one of existing sizes and ensuring the serviceability of the electrical incinerator by testing of the same after repair complete all as specified and directed.
Periodical maintenance / servicing of Electrical Incinerator of 20 KG/Hr capacity installed at CGRA Rameswaram for smooth operation by dismantling/opening of the incinerator removing defective parts, replace them with the new parts, cleaning of the entire incinerator from inside, repair to blower fan, MCB, tightening all electrical connection, replace cable lugs and cable gland with new one of existing sizes and ensuring the serviceability of the electrical incinerator by testing of the same after repair complete all as specified and directed.
Supply only Heating Coil of 30 Kwatt Capacity (spares) for Electrical Incinerator of 20 KG/Hr capacity of exisiting make and model against Item here in above
Supply only Blower fan motor (spares) for Electrical Incinerator of 20 KG/Hr capacity of exisiting make and model against Item here in above
Supply only Automatic Modular Contactors with Manual Override - TP, 63 Amp, 3P (spares) for Electrical Incinerator of 20 KG/Hr capacity of exisiting make and model against Item here in above
Periodical maintenance / servicing of Solar Power Plant (on Grid) of 4 X 10 KWp capacity installed at CGRA Rameshwaram, Kochi for smooth operation of Solar Power Plant and ensuring the serviceablity by renewing the defective spares, settings/ caliberation etc carrying out inspection /work by an authorised dealer of OEM complete all as specified and directed.(Solar Power Panels Make:-Vikram Solar Make of Solar Inverter :- Delta) Solar Panels :- (a) The timely and regular cleaning of solar cells and PV panels. Cleaning of the Soalr Panels shall be done using soft cloth,biodegradable soap, wiper, and a soft bristles brush. Don't use an abrasive sponge or soap to clean the solar panels. (b) Regular maintenance of all thermal-based components. (c) Testing and upkeep of circuits to ensure smooth functioning of the Soalr system.
(d) Checking/adjusting of sensers. (e) Carrying out visual inspections of Solar sysytem fortnightly. (f) Conducting verifications of the PV system operations. (g) Tracing of IV curves and thermal imaging. Controller and inverter (a) Testing and upkeep of circuits to ensure smooth functioning of the Solar system. (b) Check the connections, make sure that they are fixed tightly. (c) Maintain the cleanliness of the air intake filter for the smooth functioning of the inverter. (d) Checking of the error code if any and rectify the same. (e) An electrical inspection to confirm that all the strings of solar array are operating.
(f ) Interior inspection of all devices, boxes, inverters, switches, etc. (g) Infrared inspection of electrical connections looking for loose connections and hot spots. Notes: (i) Spares, wires, nut & bolts etc or any other petty/small parts required for maintenance and servicing of the Solar Plant is inclusive in the quotated rate. (ii) Charges for Major repairs, changing of the solar panel, inverter, changing of the contactor will be out of scope of the work. However the damages caused due to negligence of the contractor will be made good without any extra cost by the contractor. Cost of minor spares required for proper operation of Solar plant and Control panel shall be deemed to be included in the rate quoted.
Schedule of Credit (Minus) Rs.40880.00 NOTE: Bidder shall insert credit amount of Rs. 40880.00 as rate in Green field under Col-13.
Jack Electrolinks Private Limited
Ashbel Engineering Enterprises
sanjay Traders
AB CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .