| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC C 3 SHAHDANA COLONY BAREILLY 243005 | BAREILLY | BAREILLY | UTTAR PRADESH | 243005 | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹36.2 L+₹21,768.60 (0.61%)Rejected-Finance | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹37.9 L+₹2.0 L (5.54%)Rejected-Finance | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹38.8 L+₹2.8 L (7.82%)Rejected-Finance 160 PREM NAGAR BAREILLY | L4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L5₹39.5 L+₹3.6 L (9.93%)Rejected-Finance 113 SURESH SHARMA NAGAR NEAR S S V ENTER COLLEGE BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹48.6 L
EMD Value
₹97,200
Closing Date
28 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
SPECIAL REPAIR TO JCO/OR MD ACCN NO. 61/A to 61/D AT IBGH AREA, SPECIAL REPAIR TO JCO/OR MD ACCN NO. T-43/1, 2 AND 3 AT IBGH AREA OF MH BAREILLY AND PROVISION OF COOLER STAND AT MAP ACCN OF JRC UNDER AGE B/R - II OF GE (WEST) BAREILLY.
2023_MES_630174_1
8162/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE WEST BAREILLY
₹97,200
Yes
30 Jan 2024
28 Nov 2023
30 Dec 2023
28 Nov 2023
28 Dec 2023
16 Dec 2023
Amount
S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks, cooler stand and similar work conforming to Fe-290 Grade E-165 complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Cutting holes in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required exc. half brick but not exc. one brick thick wall complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying 2 mm thick wall care putty and two coat of acrylic distemper / distemper oil emulsion (OBD) over new plastered wall surfaces over a coat of primer of any description complete all as specified and directed.
M&L Two coats of cement based paint on new plastered wall surfaces over a coat of 2 mm thick wall care putty of any description including preparation of surfaces over a coat of primer complete all as specified.
S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane including Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
Demolition of reinforced cement concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking up or down 15 mm bore steel water tubing and connection complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connection complete all as specified and directed.
Dismantling of water tank exc. 500 Litre but not exc. 1000 Litre capacity complete all as specified and directed.
Dismantling of corrugated or semi corrugated asbestos cement sheets in roof covering complete all as specified and directed.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafter, purlins where connected to common rafters, running rails, guides for sliding doors fixed with angle cleat and other connecting plates conforming to Fe-290 Grade E-165 complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based Semi-Corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for E-board false ceiling consisting of powder coated GI wall angle, main T and Cross T of 25mm x 25mm x 1.40 mm thick grid frame work, joist, angle / Tee as directed and mild steel wire hook not less than 6mm dia with arrangement for adjusting height of ceiling and including provn of 4mm thick E-classic board in pnel of size 600 x 600mm with necessary off cut including dismantling of existing false ceiling and taking down and refixing of electric fitting carefully complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile, including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.36 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile, including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
All as per S.No 23 above but on vertical surfaces including 10mm thick in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for glazed ceramic coloured tiles 450 mm X 350 mm X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile including rendering 10 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and fair complete all as specified and directed.
M & L for 18 – 20 mm thick machine cut black granite stone slab as in floor, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the slab including necessary cutting, grinding, rubbing, polishing rounding to exposed edges including rendering 10 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and fair complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
M & L for providing reinforced cement concrete, type A-1, 1:1.5:3 (using 20 mm graded stone aggregate) (nominal mix) as in lintel / roof beam and chajja, slab supported on walls, landing, balconies, shelves, including bonding agent, complete all as specified and directed.
M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in fair finished surface of concrete complete all as specified and directed
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on other than fair faces of brick work or stone masonry surfaces with cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth using water proofing compound without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid separtely as "Supply only".
S & F of 1.25 mm thick pressed steel frame of size 105 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc. complete all as specified and directed.
S & F of 1.25 mm thick pressed steel frame of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete all as specified and directed.
S & F of 30 mm thick flush shutter solid core construction with block board core and plywood face panels commercial type on both faces complete all as specified and directed.
S & F of 30 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, without sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule 2009, part – I (Specifications) complete all as specified and directed.
S & F of stainless steel wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F of 140 mm size (Overall length of cover plate) floor door stopper of brass body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
S & F Solid PVC Door frame of size 50mm x 95mm made out of 5mm thick single side Prelam PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification complete all as specified and directed.
S & F of 30 mm thick (style thickness) factory made solid panel PVC shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded single side prelam PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and single side prelam PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of single side prelam PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable side feathered edge beading and joined together with solvent cement as per specification and drawing given on MES schedule Part – II (2020) complete all as specified and directed.
S & F steel windows / ventilators with pressed steel frame (size 95 x 45 x 1.25mm) side hung shutters including box type hinges with steel handle and steel peg stay with glazed openable shutter with glazing bar (open outside) and wire gauged openable shutter without glazing bar (open side) dovetailed or welded complete all as specified and directed. and all as sper TD drg No TD/088 dated 07 Jan 2022. Note (i) Two Shutters i.e, wire gauged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit. (ii) Rate for filling PCC in frame deemed to be included in quoted rates. (iii) MS Grill shall be measured and paid seperately under relevant item of BOQ.
S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
S & F of 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S & F of 150 mm long anodised aluminium handle, cast type complete all as specified and directed.
S & F of 100 mm long Stainless steel butt hinges, medium weight cold rolled complete all as specified and directed.
S & F of 300 mm mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete all as specified and directed.
S & F of 300 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed.
S & F of 1000 Litre capacity rotational moulded polythene white in colour in triple layered water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part-I and hoisted, fixed in position complete all as specified and directed.
S & F of 20 mm bore ball brass valves, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed.
S & F of 15 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S & F of 20 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S & F in repairs vitreous chinaware coloured wash hand basin with pedestal of size 55 x 45 x 82 cm complete including fancy pillar tap, CP waste coupling, waste pipe, complete fixing arrangement and cutting for and pinning in wall and making good complete all as specified and directed.
S & F in repair 125 mm size brass chromium plated shower rose with or with out swivel joint including fixing to steel pipe or union complete all as specified and directed.
S & F in repairs 15 mm bore fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F in repair 15 mm bore fancy type brass, chromium plated angle valve screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F of 60 cm long sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 120 mm wide with chromium plated bracket guard and railing complete all as specified and directed.
S & F in repairs 20 mm bore gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F in repairs 15 mm bore fancy type, chromium plated stop valve, with long shank and cup (Concealed Type) cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with 'P' or 'S' trap size 100mm dia front or back inlet including lime concrete bedding complete all as specified and directed.
S & F in repairs PVC low level white flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, brass screws, handle etc and S & F of 32 mm dia PVC flush pipe of suitable length and making all connection and making good disturbed surface complete all as specified and directed.
S & F in repairs 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors or walls complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors or walls complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F in repairs Stainless steel plate rack of size (90 x 80 x 25) cm with 1.0 mm thick sheet including taking out existing wooden plate rack complete all as specified and directed.
S & F in repair 0.8mm thick stainless steel kitchen sink size 590 x 460 x 230 mm undermount, single bowl (size 540 x 410 x 230 mm) including waste pipe and SS coupling, washers, etc, complete with all necessary fittings complete all as specified and directed.
S & F in repair 20mm dia stainless steel 1.0mm thick fancy type curtin dropery rod with decorative design matching brackets as approved and knobs (lattu) or end bracket as required including fitting with 80mm long SS screw with 75mm long wooden gitty of appropriate cross section in each and end & intermediate complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L for preparation of new or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over a coat of white wash complete all as specified and directed.
M & L for complete removal of existing treatment on walls, etc including cleaning of mortar drops, fungus efflorescent salts etc and prparation of old plastered surfaces and applying two coats of cement base paint over a coat of white wash complete all as specified and directed.
M & L for preparing newly plastered wall surfaces and applying two coats of oil bound distemper over 1mm thick wall care putty complete all as specified and directed.
M & L for complete removal of existing treatment on walls, etc including cleaning of mortar drops, fungus efflorescent salts etc and prparation of old plastered surfaces and applying two coats of oil bound distemper over 1mm thick wall care putty complete all as specified and directed.
S & F in repair stainless steel of AE - SI 316 grade tubular towel ring including repair of CP brass bracket complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
M & L 5 mm thick cement plaster on fair faces of brick work or concrete in ceiling with cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M & L for 18 – 20 mm thick machine cut Kota stone slab as in flooring over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in cement mortar complete all as specified and directed.
M & L for providing plain cement concrete type B-0, 1:2:4, (using 12.5 mm graded stone aggregate), as in copings, roof surface, chajja, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for providing plain cement concrete, type E-2, 1:5:10 (using 40 mm graded stone aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases), mass concrete for sunken slab complete all as specified and directed.
Providing water Proofing Treatment to RCC sunken slab as specified and directed as under:- (a) Cleaning the exsiting RCC sunken slab and vertical wall / RCC beam and hacking the surface. (b) 15mm thick plastering over the floor & vertical surface in CM 1:4 mixed with liquid water proofing compound @ 200ml per 50 Kg of cement trowelled to even and smooth finish without using extra cement. (Water Proofing compound shall be measured and paid seperately) (c) Filling the sunken portion with water for 72 hours and carrying out the ponding test (Any leakage / seepage noticed shall be repaired). (d) Applying two coats of elastomeric acrylic water proofing coating. Make Dr Fixit of Pidilite or equivalent per Sqm in each coat with roller application) (Note;- Each Coat of elastomeric acrylic compound requires 6-8 hrs to dry up itself second coat shall be applied on getting the first coat completely dried up)
Supply only liquid water proofing compound complete all as specified.
M & L for 25 mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in sub floor of floor finishes, finished even and rough complete all as specified and directed.
S & F of 35 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, without sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule 2009, part – I (Specifications) complete all as specified and directed.
S & F Solid PVC Door frame of size 50mm x 47 mm made out of 5mm thick single side Prelam PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification complete all as specified and directed.
S & F of 30 mm thick (style thickness) factory made solid panel PVC shutter made of one side prelam PVC sheet and other side decorative sheet instead of plain sheet consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded both sides prelam PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and both sides prelam PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of both sides prelam PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable side feathered edge beading and joined together with solvent cement as per specification and drawing given on MES schedule Part – II (2020) complete all as specified and directed.
S & F of factory made steel ventilator fixed top fixed type with glazing bars including one shop coat of red oxide zinc chromate primer complete all as specified and directed.
S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
S & F in repairs factory made PVC cupboard frame of size 75mm x 40mm with a wall thickness of 5mm, made out of extruded 5mm thick plain / prelam PVC sheet of density 600 Kg/Cbm, having bottom width of 50mm and thickness 10mm. All four frame lengths reinforced with 15mm x 15mm MS Square tubes of 19 gauge thickness throughout the frame and mitre cut at two corners adjointed with two nos of 15mm long brackets of 10mm x 10mm MS square tubes. The door frame shall be fixed to the wall using 8/100 long MS Screws through the frame by using PVC fastners. A minimum of 4 nos screws to be provided for each vertical member and minimum of 2 nos of screws to be provided for horizontal member etc complete all as specified and directed by engineer in charge and as manufacturer specification and drawings.
S & F factory made PVC cupboard flush type shutter of 30mm thick consisting of frame made out of MS tubes 19 gauge thickness and size 19mm x 19mm for stiles and rails. The inside panel shall consist of 20mm thick multi chamber hollow PVC section of 1mm wall thickness, bonded using solvent cement / cynoacrylate adhesive with 5mm thick plain / prelam PVC sheet, on both side of inside panel including necessary items to fix the shutter to frame such as 100mm stainless hinges, 100mm long handles made of anodised aluminium and magnetic ball catch for each pair of shutter. All four edges of the panle to be sealed with lipping of 10mm thick and 20mm wide PVC sheet baton (made by sticking 2 nos PVC foam sheet of 5mm thickness using PVC solvent cement adhesive) complete all as specified and directed.
S & F PVC boards 19/20mm thick any color / prelaminated as in cabinets including shelves and shutters, fixed with screws and adhesive as per direction of engineer in charge and manufacturer instructions including piano hinges, mgnet catcher, handles, etc complete all as specified and directed.
S & F 200 long stainless steel glossy finish handles with SS screw, complete all as specified and directed.
S & F hydraulic concealed hinge with clip on installation and integrated silent system, opening angle not less than 100 degree, for shutters thickness 15-24mm full overlay type shutters, hinge cup 35mm dia including necessary arrangement with SS screw complete all as specified and directed. Make Hettich Cat No Onsys 44471 Product Code 928143200 / Kaff Nickel Plated SC hinge 100 degree code No KHSC-0/ Godrej Product Code 6933 / Baan code LKYAHCHR4
Dismantling of water tank exc. 250 Litre but not exc. 500 Litre capacity complete all as specified and directed.
M & L for 18 – 20 mm thick machine cut black granite stone slab as in window cill, riser of steps, and urinal partition wash basin platforms, skirting, dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the slab including necessary cutting, grinding, rubbing, polishing rounding to exposed edges including rendering 10 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and fair complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed.
S & F in repair fancy type brass chromium plated soap dish of size 160 x 160 x 90mm complete all as specified and directed.
Demolition and breaking up drain pipes of 100 mm bore (salt glazed stoneware, AC or reinforced concrete) set in cement mortar complete all as specified and directed.
S & F glass corner shelf in bathroom 225 x 225 mm width chromium brackets and fixed with screwed in bathroom corners complete all as specified and directed.
Cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, lintels, shelves etc, and cutting chases for concealed water tubing or concealed conduit wiring etc, and making good on brick walls, cutting exc. 10 cm & not exc. 20 cm in girth complete all as specified and directed.
M & L for preparing newly plastered or undecorated wall surfaces and applying two coats of oil bound distemper with airless electric sprayer including preparation of surfaces over 1mm thick wall care putty complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparing old plastered or undecorated wall surfaces and applying two coats of oil bound distemper with airless electric sprayer including preparation of surfaces over 1mm thick wall care putty complete all as specified and directed.
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any portion from top of roof of building, cleaning surface of roof, with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified and directed.
M & L for 25 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in sub floor of floor finishes, finished even and rough complete all as specified and directed.
Supply and providing water proofing treatment with polymeric standard water proofing membrane 3mm thick having 10 years guarantee for water tightness complete all as specified and directed and described as under:- (a) Preparation of RCC roof surface and applying one coat of polymeric modified bitumen 85/25 @ 1.2 Kg/Sqm over a coat of polymeric primer @0.30 Kg/Sqm including cleaning surface, all as per manufacturers instructions. (b) Supply & Providing APP based polymeric membrane minimum weighng 3.5 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150 gm / sqm) land on primed surface by forced / torch application of membrane with 10cm overlaps as required thereof, complete all as specified and directed. Make IWL Hyperlas Polyster (M/s IWL), Super Thermolay (M/s STP Limited), Torch Sheild AP by pidilite Industries.
M & L for providing and injecting chemical for post construction ATT along the external wall below concrete or masonry apron using chemical emulsion at the rate of 2.25 litre per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
M & L for providing and injecting chemical for post construction ATT of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M & L for 80 mm thick, M-40 grade machine pressed pre-cast concrete interlocking paver block confirming to IS 15658-2006 with grey cement and pigment in any shape and size, laid dry over sand cushioning including 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed.
M & L for providing pre-cast cement concrete in door or window cills, lintel, Kerb, Mud Stops, bressumers, bed plat, apex stone, pintle blocks, bonders (For stone masonry) and similar items with plain faces including chamfers, weathering, throating etc. in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate and setting in cement mortar 1:6 complete all as specified and directed.
M & L for cement concrete tiles 20cm x 20cm x 20mm thick, machine pressed, set jointed and pointed in cement slurry in roof, and cut and polished complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in hard / dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L sand Cushioning laid in trenches for laying of LT UG Cable complete all as specified and directed.
M & L bricks commom burnt clay building bricks, sub class B bricks for LT UG cable protection complete all as specified and directed.
S & F GI tube light grade of dia 40mm with all fittings and fixed complete for protection of LT UG cables laid to walls or in floors or alog with poles, etc complete all as specified and directed.
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm, 4 core. complete all as specified and directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) any type (batten, surface conduit or concealed conduit) complete with fittings such as switches, ceiling roses, pendants, sockets, lamp holders, wooden / PVC blocks etc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairs and white / colour wash etc. complete all as specified and directed.
Taking down carefully by unscrewing from main switch boards / cut out boxes / MCB DBs including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed.
Taking down carefully sub main wiring including all accessories including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed.
S & F of point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (HR & FR) drawn into and including PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size solid copper conductor cable as in earth wire and connecting all metal parts, to common earth dolly complete all as specified and directed.
All as per item No. 129 hereinbefore but wiring for one 3 pin 5 Ampere socket outlet point on the same board, controlled with other switches complete all as specified and directed.
All as per item No. 129 hereinbefore but wiring for two way switch on independent board, controlled with other switches complete all as specified and directed.
All as per item No. 129 hereinbefore but wiring for bell buzzer point on independent board or on same board, controlled with other switches complete all as specified and directed.
All as per item No. 129 hereinbefore but wiring for light point controlled by two toway switches complete all as specified and directed.
All as per item No. 129 hereinbefore but wiring with using cable 2.50 Sqmm size and earth wire of PVC insulated (Green colour) 1.50 Sqmm size solid copper conductor cable for one 3 pin socket outlet, 15 Amperes on independent board complete all as specified and directed.
Supply and fixing of switch piano flush button single pole one-way 6 Ampere complete all as specified and directed.
Supply and fixing of shuttered socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed.
Supply and fixing of switch piano flush button single pole one-way 15 Ampere complete all as specified and directed.
Supply and fixing of shuttered socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed.
Supply and fixing of bell push button type single pole one-way 5 Ampere complete all as specified and directed.
Supply and fixing of single phase call bell ‘DING DONG’, AC 230 volts single pole fixed over and including pressed steel sunk box of size 175 X 100 mm duly covered with 3 mm thick bakelite sheet complete all as specified and directed.
S & F of ceiling rose three phase, PVC / polycarbonate isolated body complete all as specified and directed.
S & F in replacement electronic type fan regulator 230 volts, step type, socket type, hum free 100 / 300 watt capacity complete all as specified and directed.
S & F of lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed.
S & F surface mounting LED light fitting aluminium extruded T-5 batten, 10 watt 2 feet, including all accessories prewired complete all as specified and directed.
S & F surface mounting LED light fitting aluminium extruded T-5 batten, 20 watt 4 feet, including all accessories prewired complete all as specified and directed.
S & F LED lamp, 12 watt 230 volt AC, integrated circuit rechargable type complete all as specified and directed.
S & F security light fitting, LED type, 20 watt, 6000K, pressure die cast housing with prismatic ploycarbonate diffuser & indivudual LED as light source with integrated electronic driver complete with GI Pipe mounting bracket of size 25/32mm dia and 1.20m long fixed to wall with and including nut, bolts, and GI clamps of size 50 x 6mm as required including two coats of synthertic enamel paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed.
M&L for sub main wiring with two single core 4.0 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. ( Note :- Two runs of 4.0 sqmm (FRLS), one run of 4.0 sqmm (FRLS) copper conductor and one run of PVC conduit shall be measured as one unit length)
M&L for sub main wiring with two single core 6.0 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 6.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. ( Note :- Two runs of 6.0 sqmm (FRLS), one run of 6.0 sqmm (FRLS) copper conductor and one run of PVC conduit shall be measured as one unit length)
Taking down carefully by unscrewing from point wiring connection, ceiling fan, including sealing the cable ends, dismantling of fan blades and keeping the same in safe custody and hanging of ceiling fan after re-fixing fan blades in existing position and making electric connection with 0.50 Sqmm size flexible wire copper conductor three core of suitable length complete all as specified and directed.
Taking down carefully exhaust fan with lovers from existing site and carry out servicing by opening the motor, removing / cleaning the dust from complete body, oiling greasing complete including one coat of smoke grey enamel paint in complete fan and lovers, cutting of wall in appropriate size for fixing of exhaust fan and making good the surfaces of wall and make the fixing arrangement with grouting four Nos fully threaded bolts on wall or as required at site complete all as specified and directed.
Taking down carefully geysers of any make and capacity, dismantling the same for inspection, taking out all unserviceable and brunt spare parts, de scaling and cleaning of tank thoroughly with washing compound or liquid solution, applying one coat of milky white synthetic enamel paint with sprayer after preparation of surface, writing work as per existing pattern with black synthetic enamel paint and re-fixing of geysers at its original position complete all as specified and directed. NOTE: - Spare part shall be measured and paid separately in respective items of this schedule.
Taking down electric meter carefully and refixing the same after building repair, including the same fixed on new laminated sheet as required at site complete all as specified and directed.
S&F MCB TPN 63 Amp 415 volt, 10KA, 'C' curve suitable to fix in the DB complete all as specified and directed by the Engr-in-Charge.
S&F MCB SPN 40 Amp 240 volt complete all as specified and directed by the Engr-in-Charge.
S&F MCB single pole 6 to 32 Amp 240 Volt 'B' curve 10 KA complete all as specified and directed by the Engr-in-Charge.
Supply and fix flush sheet metal enclosure TPN DB 4 way with double door protection, IP-42, 415 Volt, 3 Phase, 4 wire system, detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links complete including taking down old unsv all as specified and directed.
Supply and fix flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links complete including taking down old unsv all as specified and directed.
Supply and fix flush sheet metal enclosure SPN DB 4 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links complete including taking down old unsv all as specified and directed.
S & F Meter Box flush on wall of suitable size as existing space made out of CRCA sheet of 2mm thick indoor type totally enclosed weather, dust and cermin proof with front opening hinged door and locking arrangement with angle iron frame alround panel body duly grouted on wall, having inner shell for fixation of TPN 8 way and space for fixing single phase KWH meter of suitable capacity 04 Nos, Copper lugs, spacers, Mounting channel, rubber gasket, locking knobs, hylem sheet, PVC shrinkable connections, suitable compartments, and epoxy powder spray painted with one coat of primer complete including taking down existing Meter Box complete all as specified and directed. Note All Connection with wiring with 6Sqmm PVC Insulated Single core Multistranded drawing through PVC flexible conduit and conected with appropriate size copper thimbles.
Material & Labour for earthing complete including taking out old unsv and replace with galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe 'light grade' as water pipe from earth chamber and including excavation and earth work, PCC 1:3:6 type C1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced all as specified
Taking down carefully service connections of any description from pole, wall or service brackets etc, including making good disturbed surfaces to mtch with the existing surface complete all as specifie and directed.
NOTE- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
JAI SRI RAM ASSOCIATE
REHAN CONSTRUCTIONS
Builders Harpal
M/S Harshri Nath Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .