Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-Finance | ₹22.3 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹23.9 L+₹1.6 L (7.08%)Rejected-Finance | ₹23.9 L+₹1.6 L (7.08%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹24.0 L+₹1.7 L (7.69%)Rejected-Finance | ₹24.0 L+₹1.7 L (7.69%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹27.9 L+₹5.6 L (25.1%)Rejected-Finance | ₹27.9 L+₹5.6 L (25.1%) | L4 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | AKSHITA ELECTRICAL L1 | Sadh builders L2 | M/S SRIDEVI ENTERPRISES L3 | S J REDDY L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for boring under road manually with labour suitable for inserting 50 to 100 mm bore pipe at a depth 0.75 to 1.0 mtr complete. | 30 | RM | 1,800 ₹54,000 | 2,300 ₹69,000 | 2,500 ₹75,000 | 1,170 ₹35,100 Lowest |
| 2.00 | M&L for cutting the existing hardstanding/PCC/WBM road/rocky surfaces at a depth of not less than 75 cm & 30 cm in width for passing of LT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed. | 30 | RM | 720 ₹21,600 Lowest | 1,400 ₹42,000 | 1,300 ₹39,000 | 1,440 ₹43,200 |
| 3.00 | Excavation in trenches by mechanical or other means n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in hard dense soil old unsv Cables/Pipes incl connected items complete all as specified and as directed. | 342 | Cum | 360 ₹1,23,120 | 450 ₹1,53,900 | 420 ₹1,43,640 | 270 ₹92,340 Lowest |
| 3.01NOTE for Item Nos 1 to 3 : | |||||||
| 3.021) The requirement of JCB (if any) for cutting the hard standing/PCC/WBM road surface or during earthwork is deemed to be included in the unit quoted rates. | |||||||
| 3.032) If any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates. | |||||||
| 3.043) Quoted rate is also deemed to be inclusive of clearing/removing/cutting of vegetation/tree branches/small to medium plantings/bushes etc. so as to facilitate successful completion of the work. No extra/addl payment shall be allowed to the Contr in this regard. | |||||||
| 3.054) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. | |||||||
| 4.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick. | 308 | Cum | 54 ₹16,632 Lowest | 90 ₹27,720 | 85 ₹26,180 | 180 ₹55,440 |
| 5.00 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. | 34 | Cum | 63 ₹2,142 Lowest | 95 ₹3,230 | 105 ₹3,570 | 63 ₹2,142 Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
8 Aug 2026, 6:00 pmClosed
GE (AFA) Hyderabad
GE (AFA) Hyderabad, Dundigal, Hyderabad
REPAIR RENEWALS PERIODICAL MAINT TO LT EXTERNAL ELECTRIFICATION SYSTEM AND ALLIED WORKS IN DOMESTIC
2026_MES_777294_1
8719/E8
Open Tender
Civil Works
Item Rate
330 days
HYDERABAD
As per NIT
5 documents required · 5 mandatory
₹500
Yes
GE (AFA) HYDERABAD
₹40,000
Yes
11 Sept 2026
9 Jul 2026
10 Aug 2026
9 Jul 2026
8 Aug 2026
24 Jul 2026
9 Jul 2026 - 24 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for boring under road manually with labour suitable for inserting 50 to 100 mm bore pipe at a depth 0.75 to 1.0 mtr complete. | 30 | RM | - | - |
| 2 | M&L for cutting the existing hardstanding/PCC/WBM road/rocky surfaces at a depth of not less than 75 cm & 30 cm in width for passing of LT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed. | 30 | RM | - | - |
| 3 | Excavation in trenches by mechanical or other means n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in hard dense soil old unsv Cables/Pipes incl connected items complete all as specified and as directed. | 342 | Cum | - | - |
| 3.02 | 1) The requirement of JCB (if any) for cutting the hard standing/PCC/WBM road surface or during earthwork is deemed to be included in the unit quoted rates. | - | - | - | - |
| 3.03 | 2) If any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates. | - | - | - | - |
| 3.04 | 3) Quoted rate is also deemed to be inclusive of clearing/removing/cutting of vegetation/tree branches/small to medium plantings/bushes etc. so as to facilitate successful completion of the work. No extra/addl payment shall be allowed to the Contr in this regard. | - | - | - | - |
| 3.05 | 4) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. | - | - | - | - |
| 4 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick. | 308 | Cum | - | - |
| 5 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. | 34 | Cum | - | - |
| 6 | M&L for HDPE DWC (Double Wall Corrugated) Pipe of rating 450 N, ISI marked with Min OD 63 mm, Orange colour for LT UG Cable protection with & including Couplers, RR & NFP properties/features confirming to IS 16205 Part 24:2018 & IEC 61386 Part 24:2007 complete all as specified & as directed by the Engr-In-Charge. Make - Supreme (Cable Guard) / Astral (Telerex) or techno-commercially equivalent of Finolex / Polycab. NOTE : Purchase Vouchers & Test Certificates to be submitted in Original to the Engr-In-Charge. | 1,107 | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
TENDERPAGES8719.pdf
Tender Documents • 0.51 MB
BOQ_870535.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .