Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹16.3 L+₹29,478 (1.84%)Rejected-Finance M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | L2 | Rejected-Finance Being Not Lowest |
Tender Value
₹16.3 L
EMD Value
₹32,660
Closing Date
1 Apr 2020, 6:00 pmClosed
GE Lansdowne
Garrison Engineer Distt Pauri Garhwal PIN-246155
Repair / maint of internal and external electrification and external water supply including misc E/M works at Kotdwara under GE Lansdowne
2019_MES_310522_3
8520/E8
Open Tender
Civil Works
Item Rate
180 days
GE Lansdowne
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Lansdowne
₹32,660
21 Aug 2020
18 Mar 2020
3 Apr 2020
18 Mar 2020
1 Apr 2020
19 Mar 2020
Amount
M& L, for earthing with galvanised steel earth plate of size 600 x 600 x 6 mm thick burried directly in ground not less than 2.5 mtr below grond level, earth plate placed on all side with charcoal mixed with salt to a thickness of 150 mm connected by GI earth strip of size 25 x 4 mm thick soldered and revetted to earth plate. GI earth strip will be protected by using 40mm bore GI pipe (light grade ISI marked) from top edge of earth plate to main earth point to be connected and 20mm dia GI watering pipe medium grade ISI marked.with funnel with wire mesh etc. The earthing includes PCC (1:3:6) type C1 using stone agg pit, RCC cover (1:2:4) type B-1 using 20mm graded stone agg and angle iron frame of 25 x 25 x 5mm, all as specified and shown in electrical plate No 3 of SSR Part - I
Dismantling old U/S MCCB any type and S& F MCCB 4 pole ,415 volt, adjustable type 200 Amp breaking capacity 36 KA all as specified and directed .
Dismantling old U/S MCCB any type and S& F MCCB 3 pole ,415 volt, adjustable type 100 Amp breaking capacity 16 KA all as specified and directed .
M&L, for dismantling, detecting the fault and seggregation of LT/HT leg coil from transformer for rewinding LT/HT coil with enamelled insulating copper wire of required gauge including insulating materials of superior quality such as craft paper cotton tapes HT/LT insulation tape varnishes etc so as to meet their original specification including opening and heating as required complete all as specified and directed.
Disconnecting defective transformer indoor/outdoor of any capacity 100KVA to 400 KVA both from HT/LT sides, and then drainage of complete transformer oil, opening of top cover with due care and removal of all HT/LT winding connections from bushing and then lifting of core by means of tripod and chain pulley with due care for inspection and ascertain it’s serviceability state after keeping it aside. Removal of all sludge and unwanted material from tank and core, lowering of core assembly after carrying out required repairs to the winding and core. In case the repairs which are not possible at site then the transformer has to be taken to the work shop for repairs. Note :- (i)The cost of transportation shall be paid separately. (ii)The cost of rewinding shall be paid separately. (iii)The cost of dehydration/filtration & other necessary repair as directed shall be measured & paid for separately under relevant items of Sch’A’ (iv) Any additional transformer oil, if required will be filled by contractor and shall be paid under appropriate item.(v) The cost of assembling after complete repair are included in the rate quoted in this item.
Disconnecting and dismantling burnt Copper bushing and S&F new copper bushing incl insulator LT side suitable for 160 kva transformer capacity installed at any location or as sample complete all as specified and directed by Engineer-in-Charge. Note:- 4 Nos of copper bushing is considered as one set
Disconnecting and dismantling burnt Copper bushing and S&F new copper bushing incl porcelian insulator HT side suitable for 160 kva transformer capacity installed at any loaction or as sample complete all as specified and directed by Engineer-in-Charge. Note:- 3 Nos of copper bushing incl porcelain insulator is considered as one set
Supply and filling transformer oil conforming to IS 335-1993 for topping up of the oil level of trasformer of any capacity of die electric strength 50 KV complete all as specified and directed.
Preparation of old surface of transformer 11KV/433V for painting externally including fins/radiators removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel metallic paint by means of spray gun at site of installation of transformer complete all as specified and directed by engineer in charge suitable for following capacity of transformer up to 200 KVA complete all as specifed and directed.
Dehydration/centrifuging of transformer oil by means centrifuging machine electrically operated at site of installation of transformer in running condition of transformer including testing of transformer oil before and after centrifuging from top and bottom of transformer at 4mm gap the BDV should be 40KV complete all as specified and directed by engineer in charge.
M & L, for tinkaring, welding, denting / Painting to damage door and MS iron framework, inculding hinges of door, nuts, bolts, washers, welding and locking arrangement. Bending cold and hot Driling hole for bolts, in any size as required or directed and inclusive of one primer coat of red oxide primer one under coat and one finishing coat of synthetic enameled paint with existing colour and having letter writing (required instruction) in white/ Red paint, complete and taking out to existing old U/S MCCBs, Bus bar from LT panel carefully and replacement with new one aluminium lugs to incoming and out going LT cable, complete servicing testing and commissioning in all respect al as directed. Note: Excavation work and MCCBs will be measured and paid separately under respective items of this schedule .
Supplying, streching and fixing in replacement of over head ACSR conductor any size ie. weasel,Ferret,and Dog and any type fixing on iron steel tubular pole including binding/jointing the conductor to indulator with and incl 14 SWG binding wire complete all as specified and directed.
M&L, for galvanized steel wire 3.15 mm or4mm dia continous earth wire on pole or guard wire for protecting fallen overhead conductor incuding winding wire of suitable size complete all as specified and directed.
Cutting / trimming of tree branches touching/ embracing HT/ LT OH line in order to maintain clearance of 1.5 Mtr on either side around the conductor complete all as spefified and directed. Note:- All necessary T&P has to be arranged by contractor.
Dismantling insulators any type, any size complete all as specified and directed.
Supply & fixing in replacement pin type porcelain,vitreous, white,brown insulator including one galvanised mild steel spindle , two galvanised iron washer and one galvanised iron nut, 100mm height 65mm dia, 1100V grade complete all as specified and directed by Engr in Charge
Supply & fixing in replacement disc type insulator porcelain various 145 mm height and 255 mm dia ball and socket type white, brown or green two in series as assembly tension with tension clamps for conductor working pressure 11000 volts all as specified and directed.
Dismantling and taking out old unserviceable PCC/Tubular pole and struts of any size including clamps insulators, cross arms etc of any type complete all as specified and directed.
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00 mtr long) complete all as specified and directed. Note:- Required earth work, PCC foundation and pole painting will be paid seperately under relevant items of Sch A
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.00 mtr long) complete all as specified and directed. Note:- Required earth work, PCC foundation and pole painting will be paid seperately under relevant items of Sch A
M&L for refixing of poles in same place or other place as directed after taking out pole from earth, incl transportation if required and refixing to same place or other place as directed incl necessary earth work, coping and fixing of existing over head conductor complete all as specified and directed.
Dismanlting and taking down bend/damaged mild steel work such as cross arms, bracing, supported, clamps & back plates etc
M&L steel work in FE-410-S grade for cross arms, bracing, supported, clamps & back plates fabricted from structural steel section including nuts, bolts, washers, welding. Bending cold and hot Drilling hole for bolts, in any size as dincted or directed and inclusive of one primer coat of red oxide primer one under coat and one finishing coat of paint aluminum grey complete as specified and directed.
M&L for preparation of old treated surface of existing steel tubular poles 8/9 mtr long ( upto 1.20 mtr from coping/ground level(whichever is on upper side)) but incl brackets, clamp cross arms etc with two coat of aluminium paint over one coat of red oxide primer incl writing MES No. complete as specified and directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 Sqmm 3 core complete all as specified and directed.
Supply and fix cable jointing kit end termination for 1.1 KV grade cable complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 300 sqmm, Indoor/Outdoor type complete all as specified and directed.
Taking down of old U/S HT armoured cable and Supply and lay XLPE insulated, screened, PVC bedded, galvanized steel strip or wire axmoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 Sqmm, 3 core complete all as specified and directed.
Disconnecting the unserviceable under ground cable, taking out the same and supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 1554) in trenches / ducts / through GI pipes under roads of size 10 sqmm 2 core complete all as specifed and directed. Note;- The earcth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
All as per item No 28 here in above but Cable of size 25 sqmm 3.5 core complete all as specifed and directed.
All as per item No 28 here in above but Cable of size 70 sqmm 3.5 core complete all as specifed and directed.
Excavation in post holes (or similar holes ) in soft/disintegrated soil each n exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not execeeding 25 cm , watering and removing surplus soil to a distance n exc 50 m and making good surface complete all as specifed and directed.
Excavation in trenches in soft/disintegrated soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/foundation etc complete all as specified and directed.
Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and spread fine river sand in trenches as cushioning to underground cable on top and bottom of cable all as specified (measurement to be taken after punning down).
M&L for cable protection bricks common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches all as specified and directed at site.
Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road etc. for cable protection complete all as specified and directed .
M & L, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in mass concrete/foundation complete all as specified and directed.
M & L PCC 1:4:8, type D2, ( using 40mm graded stone Agg) in foundation and posts including caps and bases all as specified as directed.
S&F in replacement of lightning arresters expulsion type for 11 KV HT complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed.
Disconnecting, dismantling,and taking out of unserviceable Analog type ampermeter from LT panel box and supply and fixing new three phase ampere meter digital type CT operated, of range (0-500 Amps), of size 96x96mm for LT, including necessary control wire connection and necessary thimbles nut bolts etc testing incl cuting if required in existing LT panel complete all as directed.
Disconnecting, dismantling,and taking out of unserviceable Analog type voltmeter from LT panel box and supply and fixing new three phase voltmeter digital type PT operated, of range (0-500 V), of size 96x96mm for LT, including necessary control wire connection and necessary thimbles nut bolts etc incl cuting if required in existing LT panel and testing complete all as specified and directed.
Taking down of old U/S service cable and Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, twin core cable flat or circular 10 Sqmm complete all as specified and directed.
Taking down of old U/S service cable and Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, twin core cable flat or circular 16 Sqmm complete all as specified and directed.
Disconnecting and taking out existing light fitting of any description and in any position on walls or poles complete and Supply, fixing & testing 35 W LED road way light fitting mounting type made out of one piece in pressure die-cast aluminium, alloy powder coated housing enclosed with glass cover in frame fitted luminaries complete with electronic driver and all accessories suitable for & including lamp 35 W with suitable No's of LEDs . The fitting shall IP 65 protection, duly prewired complete with and including connecting the fitting to bus bar box/Main switch with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor copper conductor cable complete all as specified and directed. Make :- Phillips Cat No BRP050 LED 036 CW R1 MF PC S1 PSU GR / Havells/ GE lighting
Disconnecting and taking out existing light fitting of any description and in any position on walls including rusted brackets complete and Supply, fixing & testing 60W LED flood light fitting mounting type made out of one piece in pressure die-cast aluminium, alloy powder coated housing enclosed with glass cover in frame fitted luminaries complete with all accessories and suitable for & including lamp 60 W high power LEDs . The fitting shall IP 65 protection, duly prewired suitable for and including mounting bracket made of MS Angle Iron 40x40x5mm , 900mm long, bent to shape cutting,drilling of holes & welding as required & directed etc fixed/grouted on wall/pole with fastner's nut,bolt washers as required and including painted with two coat of aluminium paint over a coat of red oxide primer with and including connecting the fitting to bus bar box/Main switch with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor copper conductor cable complete all as specified and directed. Make :- Philips cat part no BVP161LED60NW/CW/WW 70W / Havells/ GE lighting
Taking down existing bracket complete and S&F 32 mm dia GI light grade pipe bracket 1.20 m long bent to shape by cutting & welding as required & directed and fixed to pole with two Nos of FI clamps 50x6 mm to be tightened with bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing fiber/plastic KIOSK box complete with housing and one number MCB (including MCB SP 6A), on PCC/Steel tubular pole with the help of FI Clamp 20x4 mm including nuts bolts and washers etc and one coat of red oxide primer and two coat of aluminium paint on MS work. Make of Kiosk box-Sintex/Havells/hensel or equivalent. Make of MCB-Standard/Havells/ or equivalent.
All as per Srl item No. 49 here-in-above but 500 Ltr capacity complete all as specified and directed.
S & F in replacement solar plate collector (FPC) suitable for 1000 Ltr solar water heater system complete all as specified and directed. Make :- TATA BP Solar
S & F in replacement heat exchanger kit suitable for existing solar water heater system complete all as specified and directed.
Disconnecting the existing non functional submersible pump set from electric supply from panel, dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacity & in any position, alongwith existing column pipe 100 mm dia and existing submersible cable of any size from the bore well (approximately 500 feet depth of pump set from GL) and staking the pump and column pipes near by the bore well for inspection complete all as specified and directed . (including notes mentioned here in below in item no 53.01) NOTE : 1. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Number of column pipe may vary from 30 to 50, The existing pipes , screwed and socket joints shall be checked for its serviceability & unserviceable joints alongwith flanges shall be removed from the column pipe by cutting the pipes & making new thread in pipes for fixing of new socket and nut bolt, the cost of same shall be deemed to be included in the quoted rate for above item. However cleaning of pipes if any required shall be measured & paid separately.
Taking out & removing old burnt out windings of the submersible electric motor of capacity 35 HP, Three phase, 415 Volts, 50 Hz, AC supply capacity and rewinding of submersible electric motors with existing size PVC insulated, copper conductor wire including cleaning the slots with carbon- tetra-chloride solution before rewinding ,transportation to site complete all as specified and directed
Lowering down of the submersible pump set of any description and any capacity & in any position, in bore well alongwith column pipe 50mm dia and submersible cable of any size (approximately 500 feet depth of pump set from GL) including making necessary electric connections & testing the pump set after lowering complete all as specified and directed NOTES :- 1. Contractor shall take proper precautions while lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lowering of pump set etc shall be arranged by the contractor at his own cost. 2. Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to column pipes & assembling, jointing and fixing column pipes with MS internally threaded flange welded with column pipe by using 04 Nos 20x3mm MS strips and thereafter jointed with rubber gasket joints and nuts, bolts / pump set at the end / submersible cable and making necessary connections and testing including reconnecting water supply system. The required materials like column pipe /flanges with rubber gasket joints/ submersible cable/ repaired pump sets etc shall be met out with old retrieved materials and additional quantity of column pipe, flanges with rubber gasket joints , submersible cable & straight through joint of cable shall be measured and paid for separately under respective item of this Schedule as “Supply only”, but the rate for its fixing shall be deemed to be included under this item.
Disconnecting and taking up or down old existing GI tubing and connections,including connected fittings/accessories and fixtures of any description/ grade and in any position in trenches/under floors/road / on walls etc and making good the disturbed surface complete all as specified and directed for the following sizes :- 25 mm bore
All as per item No 56 here in above but 40 mm bore complete all as specified and directed
All as per item No 56 here in above but 50 mm bore complete all as specified and directed
Supply, fixing, laying, jointing & testing of galvanised iron water tubing 'medium grade' conforming to IS-1239 with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc as required complete fixed checknuts, caps, plugs etc as required complete fixed to walls and ceilings, laid in trenches/under floor/under road or floors complete all as specified and directed for the following sizes :- 25 mm bore
All as per item No 59 here in above but 40 mm bore complete all as specified and directed
All as per item No 59 here in above but 50 mm bore complete all as specified and directed
Disconnecting and taking out old unserviceable Gate valve/Globe valve and Supply, fixing, jointing and testing, of gun metal globe or gate valve with iron wheel head, both ends screwed for iron pipe, conforming to IS 778 complete all as specified and directed for following bore of pipes :- 25mm bore
All as per item No 62 here in above but 40mm bore complete all as specified and directed
All as per item No 62 here in above but 50mm bore complete all as specified and directed
Supply and fixing test and connecting sluice valve heavy duty 150 mm dia PN 1.6 with brass spindle with two nos of MS flange of 16 mm thick 8 holes with nuts and bolts packing materials complete including cutting the existing watermain for fixing cast iron steel sluice valve and jointing welding complete all as specified and directed
All as per item No. 65 here in above but 100 mm dia complete all as specified and directed
All as per item No. 65 here in above but 80 mm dia complete all as specified and directed
Disconnecting and removing old existing non functional electric motor, of following capacity of booster pump / centrifugal pump of any description and in any position, dismantling and strip opening of the motor, for carrying out repair/ servicing /overhauling mechanically and electrically, cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, ie bearing,connecter, fan blade, nuts and bolts etc with and including removing the old existing burnt windings, cleaning the slots & rewinding of the following capacity motor, operating on 415 V, 3 Phase, 50 Hz AC supply with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) The windings of motor including windings wire and connected material is deemed to be included in above quoted rates. Motor of capacity 5 HP operating on 415 V, 3 Phase, 50 Hz AC complete all as specified and directed.
All as per item No 68 here in above but Motor of capacity 1 HP operating on 415 V, 3 Phase, 50 Hz AC complete all as specified and directed.
Disconnecting /Dismantling all connections and taking out old Pebbles/granulars etc including depositing the same to a distance upto 300 mtr where directed. and S&F multigrade filtration media for Mode No -MGF 1400, Dia-1400 mm, Height-1875mm of following sizes type and size: 1-3/4" Pebbles-125 mm height
All as per item No 70 here in above but 3/4- 1/2" Pebbles-100 mm height complete all as specifed and directed.
All as per item No 70 here in above but 1/2-1/4" Pebbles-100 mm height complete all as specifed and directed.
All as per item No 70 here in above but 1/4-1/10" Pebbles-100 mm height complete all as specifed and directed.
All as per item No 70 here in before but Graded Mesh Sand(6-14 & 15-30) -925 mm height
Disconnecting /Dismantling all connections and taking out old Pebbles/granulars etc including depositing the same to a distance upto 300 mtr where directed. and S&F Activated carbon & filtration media for Model No - ACF 1600, Dia - 1600mms , Height-1875mm of following sizes typeand size: 1-3/4" Pebbles-125 mm height
All as per item No 75 here in above but 3/4- 1/2" Pebbles-100 mm height complete all as specifed and directed.
All as per item No 75 here in above but 1/2-1/4" Coarse silex -100 mm height complete all as specifed and directed.
All as per item No 75 here in above but 1/4-1/10" Fine Silex-100 mm height complete all as specifed and directed.
All as per item No 75 here in above but Granular activated carbon - 850 IV Height - 1000 m complete all as specifed and directed.
Disconnecting, dismantling and taking out the non-functional Air conditioner window type of any description, any make and in any position, 1.5 TR/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with using caustic soda/detergent powder solution, checking serviceability of wiring & parts, painting the bottom with one coat of black synthetic enameled paint, brazing, reassembling and testing of the AC complete all as specified and directed
Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete all as specified and directed. NOTE :- (Applicable for Sch ‘A’ Item No. 81 & 82 (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply & fixing ” under appropriate item of Sch ‘A’. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item
Disconnecting and taking out defective / nonfunctional air filter and Supply & fixing Air filter nylon type suitable for window type/Split A/C complete all as specified and directed. Make – Athlete / John Flower
Disconnecting and taking out existing defective / unserviceable remote control assembly with PCB of any description and in any position of any type of split AC & Supplying & fixing new remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed . (Make : Carrier/Hitachi/LG )
Taking out defective sealed unit compressor of window type AC of capacity 1.5 TR of any make and S&F new compressor of original make in the existing AC, including welding, brazing of gas pipe line, vacuum pressure and testing with charging of Refrigerant Gas and testing & commissioning of AC complete all as specified and directed.
All as per item No 85 here in above but compressor of 2TR capacity AC of any make complete all as specified and directed. Note for item No. 85 & 86 )Refrigerant Gas required for charging of compressor shall be measured separately under respective item of this Schedule.
Supply & charging of refrigerant Gas R-22 Mono chloro difluoro methane (CHCLF2) to make up the required pressure complete all as specified and directed.
Disconnecting, dismantling and taking out the non-functional voltage stabilizer for General servicing and minor repairs AC 230 volts Single Phase 3 to 5 KVA cap. of any make by checking, tightening of electrical connection, replacement of all missing/worn out screws, indicating lamps, checking of electronic circuits to make it functional including replacement of minor defective parts complete all as specified and directed. NOTE :-The replacement of defective / nonfunctional parts shall be measured & paid for separately under appropriate item of Sch ‘A’
Supply & fixing transformer copper wound of voltage stabilizer AC, Single Phase, 230 volts of capacity 5 KVA of approved make complete all as specified and directed. .
All as per Item No 89 here in above but of capacity 4 KVA complete all as specified and directed.
Disconnecting , taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans and air circulating fans etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, Realignment of motor shaft, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction complete all as specified and directed.
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal)as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish incl ball bearing/bushes/hanging assembly if required etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engineer-in-charge for the following Fans:- Rewinding of motor of ceiling fans 1200/1400 mm sweep complete all as specifed and directed.
All as per Srl item No 92 here in above but of Rewinding of motor of exhaust fans of 300 mm sweep.complete all as specifed and directed.
All as per Srl item No 92 here in above but of Rewinding of motor of exhaust fans of 450 mm sweep.complete all as specifed and directed.
Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for ceiling fans of any descriptions & of 1400/1200 mm sweep. complete all as specifed and directed.
Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, socket, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc.
M&L for point wiring concealed type upto wall height and open with conduit after wall height with 1.5sq mm PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl PVC rigid conduit not less than 20mm dia with its accessories with provn of CI/pressed steel terminal switch box and white bakelite plastic laminated top sheet cover and fixed with brass screws cup washer for fixing switches/socket/regulators etc for the following :- One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way (Make of Cable : Finolex/RR Cable/Havells & Make for Conduit : AKG/PRESTOPLAST/PRECISION ): -
All as per serial item No 97 here in above but One 3 pin 5 Amps socket outlet on same board controlled by one, one way 5 Amps piano switch. complete all as specifed and directed.
All as per serial item No 97 here in above but One socket outlet 5/3 pin 5 Amps controlled by one switch on independent board. complete all as specifed and directed.
Material and labour for power point wiring for one 15 Amp switch socket combined outlet point on Independent Board with 2.5 Sqmm PVC insulated unsheathed,stranded copper conductor cable single core 1100V grade with in and including rigid PVC conduit 20mm or higher size medium grade in concealed manner with all PVC conduit accessories with provision of CI/pressed steel terminal switch box & white bakelite plastic laminated top sheet cover fixing with brass screws and cup washers and 1.5Sqmm PVC insulated unsheathed stranded copper single core 1100V grade as earth wire & wire connected with the main earth point all as specified & directed. (Make of Cable : Finolex/RR Cable/Havells & Make for Conduit : AKG/PRESTOPLAST): -
S&F Switch Piano Flush button single pole one way 5 Amp complete all as specified and directed.
S&F socket outlet flush type 3/5 pin 5/6 Amps 230V AC complete all as specified and directed.
S&F switch piano flush single pole one way 15/16 Amps complete all as specified and directed.
S&F socket outlet flush type 5/6 pin 15 Amps 230V AC all as specified and directed.
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting complete all as specified & directed
M&L ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as specified and directed.
S&F MCB DB SPN 4 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed.
S&F MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed.
S&F MCB DB SPN 12 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed.
Supply & fixing MCB , SP, AC, 240 volts of 06 to 40 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply & fixing Isolator, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
S&F LED Tube light fitiing 20 Watt with LED light source with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with complete with all accessories all as specified & directed Make ; Philips Astra Line 20-Watt LED (Cool Day Light) /Havells / Wipro.
S & F LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder Make ; Philips/ Havells / Wipro.
S&F LED down light 6W slim surface mounted round die cast body with premium diffuser to enusre glare free and even distribution of light incl making neccesary connections complete all as specified and directed Make:- Havells comet round LHEAAVP5IL!W006/Philips/Wipro
Supply & fixing House service bracket (hook type complete with 3.0m long G. I. pipe 40mm dia Med. Grade, two nos 90⁰ bends. M.S. hook and stay guy complete all as specified & directed
Dismantling and taking out old burnt/unserviceable sub main wiring incl concealed conduit and S&F sub main wiring concealed type in rigid PVC conduit not less than 20 mm of dia with two single core PVC insulated,unsheathed, multistranded copper conductor cable 6 Sqmm with 4 Sqmm PVC insulated, unsheathed, stranded copper conductor cable as earth wire in new PVC conduit concealed and earth wire connected to common earth point all as specified & directed.
Disconnecting the Refrigerator and strip opening for the checking of the defective parts and fixing of the new parts for proper functioning, re-assembling, refixing and re-connecting the Refrigertaor back to its original location and testing complete all as specified and directed.
Supply and fixing in replacement hermetically sealed or rotary compressor suitable for Refrigerator of capacity 165 Ltrs complete all as specified and directed. Make :- Kirloskar / Complent / Tecumseh.
Supply and fixing in replacement hermetically sealed or rotary compressor suitable for Refrigerator of capacity 310 Ltrs complete all as specified and directed. Make :- Kirloskar / Complent / Tecumseh.
Supply, charge, testing and commissioning R-134(a) gas for Refrigerator of capacity 165 Ltrs / 286 Ltrs / 310 Ltrs of any make complete all as specified and directed.
M&L for replacement of sealed type compressor unit company repaired suitable for 80/100 ltr cooling capacity water cooler fixing in position ,testing of leakage and making necessary connection and testing complete all as specified and as directed.
All as per item No. 121 here in before but 60/80 Ltr cap complete all as specified and directed.
M&L for replacement of new condensing fan motor cap 1/10 HP for water cooler complete all as specified and directed
M&L for replacement of new condensing fan motor cap 1/32 HP for water cooler complete all as specified and directed
Friends fire Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .