Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹39,960Qualified Make: KEI
Model: KEI COPPER WIRE 1.5 Sqmm per 90mtr. 11004727 JONAPUR VILLAGE SOUTH WEST DELHI DELHI 110047 | SOUTH DELHI | DELHI | 110047 | Make: KEI
Model: KEI COPPER WIRE 1.5 Sqmm per 90mtr. | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
11 Sept 2018, 8:00 pmClosed
power cord-Flexible electric cable Heating cables or Wire cotton Power for Heater
power cord- Flexible electric cable Heating cables or Wire cotton Power for Heater
power cord-Flexible electric cable Heating cables or Wire cotton Power for Heater Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 360 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable
IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * 1/14 CM/L No 2832257 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC
Elastomer Type of sheath Elastomer PVC
Elastomer Sheated No Yes
No Outer cover material Braided Non braided
Braided No. of cores 2 2
3 Conductor material Copper * Size of the conductor 1.5 sqmm * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 90 mtr * Cable bundle weight (kgs) 2 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number PWPL/FR-LF/510098B * Test Report Date 13/02/2018 * Name of Lab POLYCAB WIRES LTD * Address of the lab DAMAN * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103
Garrison Engineer Khumbathang
8 Mtn Div C/O 56 APO 360 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 90 ) Technical Specifications * As per GeM Category Specification 2/14 Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable
IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 8738194 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC
Elastomer Type of sheath PVC PVC
Elastomer Sheated Yes Yes
No Outer cover material Non braided Non braided
3 Conductor material Copper * Size of the conductor 6 * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 90 * Cable bundle weight (kgs) 5 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number 1385-2007-AQ-IND-RAV REV.02 * Test Report Date 12.12.2000 * Name of Lab DET NORSKE VERITAS * Address of the lab NEW DELHI * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103
8 Mtn Div C/O 56 APO 90 40 3/14 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 180 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable
IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 8158075 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC
3 Conductor material Copper * Size of the conductor 2.5 sqmm * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 90 mtr * Cable bundle weight (kgs) 2.5 kg * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number 78921 * Test Report Date 02.02.2010 * Name of Lab NABL Testing laboratory * Address of the lab Delhi * * Bold specifications are the golden parameters. Consignees and Quantity 4/14 S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103
8 Mtn Div C/O 56 APO 180 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 180 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable
IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 7525273 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC
3 Conductor material Copper * Size of the conductor 1 SQMM * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 100 * Cable bundle weight (kgs) na * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * 5/14 Test report number 0059687 * Test Report Date 15.02.2016 * Name of Lab BIS * Address of the lab Delhi * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103
8 Mtn Div C/O 56 APO 180 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 90 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable
3 Conductor material Copper * Size of the conductor 1.5 sqmm * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 100 * 6/14 Cable bundle weight (kgs) na * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number 0059687 * Test Report Date 15.02.2016 * Name of Lab BIS * Address of the lab Delhi * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103
8 Mtn Div C/O 56 APO 90 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 270 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable
3 Conductor material Copper * 7/14 Size of the conductor 1 * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 90 * Cable bundle weight (kgs) 1 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number 8158075 * Test Report Date 20.06.2017 * Name of Lab BUREAU OF INDIAN STANDERD * Address of the lab JAIPUR * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manoj Kumar 194103
GE Kargil C/O 56 APO 29 40 2 Narendra Kumar 194103
8 Mtn Div C/O 56 APO 241 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 270 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable
IS:9968 (Pt-1&2) for elastomer insulated cable 8/14 BIS Marked Yes * CM/L No 7306463 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC
3 Conductor material Copper * Size of the conductor 1.5SQMM * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 100 * Cable bundle weight (kgs) 7.5 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number 13703061 * Test Report Date 27/11/17 * Name of Lab FINOLEX CABLE LTD * Address of the lab KOTI NAGAR HYDERABAD * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manoj Kumar 194103
8 Mtn Div C/O 56 APO 241 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power 9/14 For Heater ( 90 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable
IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 9675508 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC Type of sheath PVC PVC
Elastomer Sheated No No Outer cover material Non braided Non braided
Braided No. of cores 2 2 Conductor material Copper * Size of the conductor 2X1.5 * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 100 * Cable bundle weight (kgs) 1.5 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number ATCC2015051406 * Test Report Date 14/05/2015 * Name of Lab AMIT TEST AND CALIBRATION CENTRE * Address of the lab 19/168
SARAI ROHILLA
OLD ROHTAK ROAD
DELHI * * Bold specifications are the golden parameters. Consignees and Quantity 10/14 S.No. Consignee Address Quantity Delivery Days 1 Manoj Kumar 194103
GE Kargil C/O 56 APO 15 40 2 Narendra Kumar 194103
8 Mtn Div C/O 56 APO 75 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 90 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable
IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 9516787 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC
3 Conductor material Copper * Size of the conductor 1.5 SQMM * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 100 * Cable bundle weight (kgs) 2.0 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC Yes * 11/14 accridiated laboratory to prove conformity to the specification Test report number 2655059/694-2010 * Test Report Date 01/11/2017 * Name of Lab BUREAU OF INDIAN STANDARDS * Address of the lab Manak Bhawan prithviraj road
C- scheme-Jaipur 302005 * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manoj Kumar 194103
GE Kargil C/O 56 APO 44 40 2 Narendra Kumar 194103
8 Mtn Div C/O 56 APO 46 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 180 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable
IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 3760869 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC
Elastomer Sheated No No Outer cover material Braided Non braided
3 12/14 Conductor material Copper * Size of the conductor 0.75 sqmm * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 90 * Cable bundle weight (kgs) 12 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number CLS1A 16 03 94957 001 * Test Report Date 14-03-16 * Name of Lab TUV SUD * Address of the lab PSB Singapore * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103
8 Mtn Div C/O 56 APO 180 40
576199
GEM/2018/B/81734
power cord-Flexible electric cable Heating cables or Wire cotton Power for Heater ,power cord-Flex
40 days
Ladakh; Kargil
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| power cord-Flexible electric cable Heating cables or Wire cotton Power for Heater | - | - | - |
| power cord- Flexible electric cable Heating cables or Wire cotton Power for Heater | - | - | - |
| power cord-Flexible electric cable Heating cables or Wire cotton Power for Heater Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 360 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable | - | - | - |
| IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * 1/14 CM/L No 2832257 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC | - | - | - |
| Elastomer Type of sheath Elastomer PVC | - | - | - |
| Elastomer Sheated No Yes | - | - | - |
| No Outer cover material Braided Non braided | - | - | - |
| Braided No. of cores 2 2 | - | - | - |
| 3 Conductor material Copper * Size of the conductor 1.5 sqmm * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 90 mtr * Cable bundle weight (kgs) 2 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number PWPL/FR-LF/510098B * Test Report Date 13/02/2018 * Name of Lab POLYCAB WIRES LTD * Address of the lab DAMAN * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103 | - | - | - |
| Garrison Engineer Khumbathang | - | - | - |
| 8 Mtn Div C/O 56 APO 360 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 90 ) Technical Specifications * As per GeM Category Specification 2/14 Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable | - | - | - |
| IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 8738194 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC | - | - | - |
| Elastomer Type of sheath PVC PVC | - | - | - |
| Elastomer Sheated Yes Yes | - | - | - |
| No Outer cover material Non braided Non braided | - | - | - |
| 3 Conductor material Copper * Size of the conductor 6 * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 90 * Cable bundle weight (kgs) 5 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number 1385-2007-AQ-IND-RAV REV.02 * Test Report Date 12.12.2000 * Name of Lab DET NORSKE VERITAS * Address of the lab NEW DELHI * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103 | - | - | - |
| 8 Mtn Div C/O 56 APO 90 40 3/14 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 180 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable | - | - | - |
| IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 8158075 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC | - | - | - |
| 3 Conductor material Copper * Size of the conductor 2.5 sqmm * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 90 mtr * Cable bundle weight (kgs) 2.5 kg * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number 78921 * Test Report Date 02.02.2010 * Name of Lab NABL Testing laboratory * Address of the lab Delhi * * Bold specifications are the golden parameters. Consignees and Quantity 4/14 S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103 | - | - | - |
| 8 Mtn Div C/O 56 APO 180 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 180 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable | - | - | - |
| IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 7525273 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC | - | - | - |
| 3 Conductor material Copper * Size of the conductor 1 SQMM * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 100 * Cable bundle weight (kgs) na * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * 5/14 Test report number 0059687 * Test Report Date 15.02.2016 * Name of Lab BIS * Address of the lab Delhi * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103 | - | - | - |
| 8 Mtn Div C/O 56 APO 180 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 90 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable | - | - | - |
| 3 Conductor material Copper * Size of the conductor 1.5 sqmm * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 100 * 6/14 Cable bundle weight (kgs) na * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number 0059687 * Test Report Date 15.02.2016 * Name of Lab BIS * Address of the lab Delhi * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103 | - | - | - |
| 8 Mtn Div C/O 56 APO 90 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 270 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable | - | - | - |
| 3 Conductor material Copper * 7/14 Size of the conductor 1 * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 90 * Cable bundle weight (kgs) 1 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number 8158075 * Test Report Date 20.06.2017 * Name of Lab BUREAU OF INDIAN STANDERD * Address of the lab JAIPUR * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manoj Kumar 194103 | - | - | - |
| GE Kargil C/O 56 APO 29 40 2 Narendra Kumar 194103 | - | - | - |
| 8 Mtn Div C/O 56 APO 241 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 270 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable | - | - | - |
| IS:9968 (Pt-1&2) for elastomer insulated cable 8/14 BIS Marked Yes * CM/L No 7306463 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC | - | - | - |
| 3 Conductor material Copper * Size of the conductor 1.5SQMM * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 100 * Cable bundle weight (kgs) 7.5 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number 13703061 * Test Report Date 27/11/17 * Name of Lab FINOLEX CABLE LTD * Address of the lab KOTI NAGAR HYDERABAD * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manoj Kumar 194103 | - | - | - |
| 8 Mtn Div C/O 56 APO 241 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power 9/14 For Heater ( 90 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable | - | - | - |
| IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 9675508 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC Type of sheath PVC PVC | - | - | - |
| Elastomer Sheated No No Outer cover material Non braided Non braided | - | - | - |
| Braided No. of cores 2 2 Conductor material Copper * Size of the conductor 2X1.5 * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 100 * Cable bundle weight (kgs) 1.5 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number ATCC2015051406 * Test Report Date 14/05/2015 * Name of Lab AMIT TEST AND CALIBRATION CENTRE * Address of the lab 19/168 | - | - | - |
| SARAI ROHILLA | - | - | - |
| OLD ROHTAK ROAD | - | - | - |
| DELHI * * Bold specifications are the golden parameters. Consignees and Quantity 10/14 S.No. Consignee Address Quantity Delivery Days 1 Manoj Kumar 194103 | - | - | - |
| GE Kargil C/O 56 APO 15 40 2 Narendra Kumar 194103 | - | - | - |
| 8 Mtn Div C/O 56 APO 75 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 90 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable | - | - | - |
| IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 9516787 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC | - | - | - |
| 3 Conductor material Copper * Size of the conductor 1.5 SQMM * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 100 * Cable bundle weight (kgs) 2.0 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC Yes * 11/14 accridiated laboratory to prove conformity to the specification Test report number 2655059/694-2010 * Test Report Date 01/11/2017 * Name of Lab BUREAU OF INDIAN STANDARDS * Address of the lab Manak Bhawan prithviraj road | - | - | - |
| C- scheme-Jaipur 302005 * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manoj Kumar 194103 | - | - | - |
| GE Kargil C/O 56 APO 44 40 2 Narendra Kumar 194103 | - | - | - |
| 8 Mtn Div C/O 56 APO 46 40 Power Cord-Flexible Electric Cable Heating Cables Or Wire Cotton Power For Heater ( 180 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Conformation of cable to IS: 694 for PVC insulated cable IS: 694 for PVC insulated cable | - | - | - |
| IS:9968 (Pt-1&2) for elastomer insulated cable BIS Marked Yes * CM/L No 3760869 * CONSTRUCTIONAL Working voltage Upto 1100V * Type of insulation PVC PVC | - | - | - |
| Elastomer Sheated No No Outer cover material Braided Non braided | - | - | - |
| 3 12/14 Conductor material Copper * Size of the conductor 0.75 sqmm * Type of conductor Stranded * Type of service General * Type of flexible cord Unkinkable * Length of cable in a bundle (meter) 90 * Cable bundle weight (kgs) 12 * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification Yes * Test report number CLS1A 16 03 94957 001 * Test Report Date 14-03-16 * Name of Lab TUV SUD * Address of the lab PSB Singapore * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar 194103 | - | - | - |
| 8 Mtn Div C/O 56 APO 180 40 | - | - | - |
Exempted
11 Sept 2018
6 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_576199.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .