| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.4 CrAccepted-AOC | ₹55.4 Cr Quoted ₹56.3 Cr | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹61.0 CrRejected-Finance 306 MANISHA BUILDING 75 76 NEHRU PLACE NEW DELHI 110019 | ₹61.0 Cr | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹62.1 CrRejected-Finance 126 A JAIPUR HOUSE AGRA 282010 PH NO 0562 2810176 9897638555 | ₹62.1 Cr | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹62.9 CrRejected-Finance | ₹62.9 Cr | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹56.9 Cr
EMD Value
₹15 L
Closing Date
9 Jan 2020, 6:00 pmClosed
HQ CHIEF ENGINEER BAREILLY ZONE
HQ CHIEF ENGINEER BAREILLY ZONE, SARVATRA BHAVAN, STATION ROAD, BAREILLY, UP,243001
PROVN OF KLP FOR 14 SIGNAL RAGT AT CLEMENT TOWN DEHRADUN
2019_MES_246656_1
CEBZ/T-01/2019-20
Open Tender
Civil Works
915 days
DEHRADUN
The contractor should meet the enlistment criteria of SS class and category a(i) alongwith PQC as per para 8(C) of NIT
9 documents required · 9 mandatory
₹3,000
GE CLEMENT TOWN
₹15 L
Yes
11 Feb 2020
11 May 2019
14 Jan 2020
11 May 2019
9 Jan 2020
23 Dec 2019
11 May 2019 - 28 May 2019
Amount
SCHEDULE 'A' PART-I (BUILDING WORK)
Total amount of SCHEDULE 'A' PART-I (BUILDING WORK) (For details see Schedule 'A' Part-I in PDF folder)
Total amount of SCHEDULE 'A' PART-II A (INTER WATER SUPPLY) (For details see Schedule 'A' Part-II-A in PDF folder)
SCHEDULE 'A' PART-II B (INTER WATER SUPPLY)
S & F chromium plated brass wall mixer 3-in-1 system fancy type with provision for both hand shower and overhead shower complete with all flange ( with hand shower and overhead shower ) screwed down for 15mm bore GI pipe complete all as specified and directed.
S & F Health faucet chromium plated 15mm bore with 1.00 mtr long metallic expendable tube and hanging arrangement complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-III-A (INTERNAL ELECTRIFICATION) (For details see Schedule 'A' Part-III-A in PDF folder)
SCHEDULE 'A' PART-III-B (INTERNAL ELECTRIFICATION)
M & L for point wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded (FRLS) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.2 mm thick pressed steel terminal box for mounting fittings i.e, normal piano switch / sockets & modular switch & sockets incl cover plate with frame and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS copper conductor cable as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed for the following: -
One light point / exhaust fan point / wall mounting fan point controlled by one, one way switch 5/6 Amperes single pole.
one light point controlled by two switches 5 Amps two way single pole.
one fan point controlled by one switch 5 Amps one way single pole.
one three pin 5 Amps socket outlet on independent board.
one three pin 5 Amps socket outlet on same board.
one bell point controlled by one bell push independent.
M & L power point wiring of copper cable FRLS grade,multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of copper cable FRLS grade,multi stranded earth conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.2 mm thick pressed steel terminal box for mounting fittings i.e, normal piano switch / sockets & modular switch & sockets incl cover plate with frame and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 2.50 sqmm size stranded FRLS copper conductor cable as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
M&L sheet metal enclosure with socket 240 Volts, single pole and neutral enclosure with a two pin earth plug top complete with one MCB SP of capacity 20 Amps ,complete all as specified and directed.
M&L for sub main wiring for 32 Amp power points with 2 runs of 4 sqmm FRLS grade insulated unsheathed, single core , multi stranded copper conductor cable 1100 Volts grade, drawn through concealed rigid non-metalic PVC conduit including PVC rigid conduit medium grade of size 25mm and one run of 4 sqmm size PVC insulated copper conductor FRLS grade complete all as specified and directed.(Note. Two run of cable and one earth conductor including conduit shall be measured as one length)
M&L for sub main wiring with 2 runs of 6 sqmm FRLS grade insulated unsheathed, single core , multi stranded copper conductor cable 1100 Volts grade, drawn through concealed rigid non-metalic PVC conduit including PVC rigid conduit medium grade of size 25mm and one run of 6 sqmm size PVC insulated copper conductor FRLS grade complete all as specified and directed.(Note. Two run of cable and one earth conductor including conduit shall be measured as one length)
M&L for load line distribution board double door type, TPN, vertical, 4 way, complete with incomming frame for 4 pole MCCB , including bus bar, neutral link, blanking plates etc complete all as specified and directed.
M&L for load line distribution board double door type, TPN, vertical, 8 way, complete with incomming frame for 4 pole MCCB , including bus bar, neutral link, blanking plates etc complete all as specified and directed.
M&L for sheet metal enclosure for DB's single door 240 V, SPN 2 way complete all as specified and directed.
M&L for sheet metal enclosure for DB's double door 240 V, SPN 4 way with rated 200 Amp bus bar complete all as specified and directed.
M&L for sheet metal enclosure for DB's double door 240 V, SPN 8 way with rated 200 Amp bus bar complete all as specified and directed.
M&L for sheet metal enclosure for DB's double door 240 V, SPN 12 way with rated 200 Amp bus bar complete all as specified and directed.
M&L for sheet metal enclosure for DB's double door 415 V, TPN 4 way with rated 200 Amp bus bar complete all as specified and directed.
M&L for MCCB 415 V, 100 Amps, 16 KA, 4 Pole complete all as specified and directed.
M&L for MCCB 415 V, 150 Amps, 36 KA, 4 Pole complete all as specified and directed.
M&L for MCCB 415 V, 200 Amps, 36 KA, 4 Pole complete all as specified and directed.
M&L for MCB SP 240 Volts, 6 Amps, 'C' series 10KA complete all as specified and directed.
M&L for MCB SP 240 Volts, 10 Amps, 'C' series 10KA complete all as specified and directed.
M&L for MCB SP 240 Volts, 16 Amps, 'C' series 10KA complete all as specified and directed.
M&L for MCB SP 240 Volts, 20 Amps, 'C' series 10KA complete all as specified and directed.
M&L for MCB SP 240 Volts, 32 Amps, 'C' series 10KA complete all as specified and directed.
M&L for MCB SP 240 Volts, 40 Amps, 'C' series 10KA complete all as specified and directed.
M&L for MCB SP 240 Volts, 63 Amps, 'C' series 10KA complete all as specified and directed.
M&L for MCB SPN 240 Volts, 6 Amps, 10KA complete all as specified and directed.
M&L for MCB SPN 240 Volts, 10 Amps, 10KA complete all as specified and directed.
M&L for MCB SPN 240 Volts, 16 Amps, 10KA complete all as specified and directed.
M&L for MCB SPN 240 Volts, 20 Amps, 10KA complete all as specified and directed.
M&L for MCB SPN 240 Volts, 32 Amps, 10KA complete all as specified and directed.
M&L for MCB SPN 240 Volts, 40 Amps, 10KA complete all as specified and directed.
M&L for MCB SPN 240 Volts, 63 Amps, 10KA complete all as specified and directed.
M&L for MCB TPN 32 Amp 10KA complete all as specified and directed.
M&L for MCB TPN 40 Amp 10KA complete all as specified and directed.
M&L for MCB TPN 63 Amp 10KA complete all as specified and directed.
M&L for energy efficient LED light fitting 18/20 Watt,230 Volt of 1200 mm length , 6000-6500 K couler temp ,decorative ultra slim linear LED lighting fixture with extruded policarbonate heat sink, environmental friendly, energy efficient, wall mounted batten integrated electronic driver complete all as specified and directed. Philips Cat No BN021CLED20SPSUCWGR52 C&S Cat Part No LT4F20WLEDT8 / WD LEDCO161820W LED HAVELLS Cat Part No- LUMILINEPLUSB 20WLED 865 SPCSS
M&L for energy efficient LED light fitting 9/10 Watt,230 Volt of 600 mm length , 6000-6500 K couler temp ,decorative ultra slim linear LED lighting fixture with extruded policarbonate heat sink, environmental friendly, energy efficient, wall mounted batten integrated electronic driver complete all as specified and directed. Philips Cat No BN021CLED6500SPSUCWGR51 C&S Cat Part No LTDC121OWLED / WD HAVELLS Cat Part No- LUMILINEPLUSB 10WLED 865 SPCSS
M&L for pendant energy efficient LED light fitting 32 Watt,230 Volt of 1200 mm length , 6000 - 8500 K couler temp , environmental friendly, energy efficient, hanging type batten integrated electronic driver,suspention of 1.5 Mtr is included (02 Nos) complete all as specified and directed. Philips Cat No SM270CLED30SE500PSUWH C&S Cat Part No LTCSP45W LED 2X2 HAVELLS Cat Part No- PLUTONEO4X1PLR30W LED 8575
M&L for surface mounting powder coated white CRCA full glow LED panel 36/40 Watt , 230 Volt, back housing made of CRCA Sheet duly power coated , Acrylic difuser ,6000K of size 600 x 600mm complete all as specified and directed. Make:- C&S Cat Part No LTCSP36WLED2x2 HAVELLS Cat Part No- PLUTONEO 2X2PLR34W LED-8405 Philips Cat No RC380B-LED 30S-6500 G4 L60W60 PSU OD
M&L for recess mounting powder coated white CRCA full glow LED panel 36/40 Watt , 230 Volt, back housing made of CRCA Sheet duly power coated , Acrylic difuser 6000K of size 600 x 600mm complete all as specified and directed. Make:- C&S cat No LTCRP36WLED2x2 HAVELLS Cat Part No- LEDDRIVERCOMBO-TW30V1A-ANA-DIM Philips Cat No RC380B-LED 30S-6500 G4 L60W60 PSU OD
M&L for slim surface mounting square LED panel al. die cast body with premium diffuser full glow LED panel 11/12 Watt , 230 Volt,6000 K of size 140 x 140 mm complete all as specified and directed. Make:- C&S Cat Part No LTRSUR12HPLED SQ / W HAVELLS Cat Part No- EDGEPROSQDLR12WLED8575 Philips Cat No DN096B LED 10S-6500PSUWH
M&L for wall light fixture made up of polycarbonate including 1x10 watt LED lamp, 230 Volt, 6000 K complete all as specified and directed. Make:- HAVELLS Cat Part No- LHDL06160099 Philips Cat No MUZRIS (Single Head)
M&L for Bldg security light fitting LED 45 Watt cast aluminium housing, toughened glass,silicon gaskect, high power LED with lens for uniform distribution pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including suitable size of GI bracket 1.5 Mtr with clamps and bolts complete all as specified and directed. Make - C&S Cat No LTESS18x2.5HPLED/LS Havells Cat Part No EUDURAPE ARLNEOSL 45WLED 75SASYTOPIC
M&L for ceiling fan of 1200 mm sweep 230 Volt,copper wound,white in colour with BEE 5 star rating including suitable size of down rod and flexible wire 2 core of size 23 x .0076" up to the ceiling rose complete all as specified and directed.
M&L for ceiling fan of 1400 mm sweep 230 Volt,copper wound,white in colour including suitable size of down rod and flexible wire 2 core of size 23 x .0076" up to the ceiling rose complete all as specified and directed.
M&L for wall fan 450mm sweep 240 V, single phase,copper wound complete all as specified and directed.
M&L for exhaust fan 250 mm sweep 240 Volt ,copper wound ,non metalic body with plastic louver shutter and brackets, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers including provn of opening of hole on brick wall and grouting nut and bolt of suitable size complete all as specified and directed.
M&L for exhaust fan 300 mm dia sweep 240 Volt,copper wound,900 RPM, heavy duty metalic with louver shutter and brackets fixed outside wall, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers including provn of opening of hole on brick wall and grouting nut and bolt of suitable size complete all as specified and directed.
M&L for exhaust fan 450 mm dia sweep 240 Volt,copper wound,900 RPM, heavy duty metalic with louver shutter and brackets fixed outside wall, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers including provn of opening of hole on brick wall and grouting nut and bolt of suitable size complete all as specified and directed.
M&L for energy meter AC Single Phase Two Wire, static energy Meter with LCD display of Accuracy Class 1.0, 240 V, 50 Hz, 5-30 A ,conforming to IS-13779 and relevant IEC standards,including transparent hinge type meter box made from engineering plastic and required length of single core FRLS grade 6 Sqmm stranded copper wire PVC insulated 1100 Volt grade for connections complete all as specified and directed .
M&L for energy meter AC Single Phase Two Wire, static energy Meter with LCD display of Accuracy Class 1.0, 240 V, 50 Hz, 10-60 A ,conforming to IS-13779 and relevant IEC standards,including transparent hinge type meter box made from engineering plastic and required length of single core FRLS grade 6 Sqmm stranded copper wire PVC insulated 1100 Volt grade for connections complete all as specified and directed .
M&L for energy meter AC Three Phase four Wire, static energy Meter with LCD display of Accuracy Class 1.0, 415 V, 50 Hz, 10-60 A ,conforming to IS-13779 and relevant IEC standards,including transparent hinge type meter box made from engineering plastic and required length of single core FRLS grade 6 Sqmm stranded copper wire PVC insulated 1100 Volt grade for connections complete all as specified and directed .
M&L for energy meter AC Three Phase four Wire, static energy Meter with LCD display of Accuracy Class 1.0, 415 V, 50 Hz, 150/5A CT oprated, including 03 Nos of CT of capacity 150/5 Amps and connected to energy meter conforming to IS-13779 and relevant IEC standards,including transparent hinge type meter box made from engineering plastic and required length of single core FRLS grade 6 Sqmm stranded copper wire PVC insulated 1100 Volt grade for connections complete all as specified and directed .
Total amount of SCHEDULE 'A' PART-IV (SITE CLEARANCE AND EARTH WORK) (For details see schedule 'A' Part-IV in PDF folder)
Total amount of SCHEDULE 'A' PART-V A ( ROAD, PATH, CULVERT AND HARDSTANDING) (For details see Schedule 'A' Part- V A in PDF folder)
SCHEDULE 'A' PART-V B ( ROAD, PATH, CULVERT AND HARDSTANDING)
S & F of single molded twin shank raised pavement markers (cat eyes) made of polycarbonate and ABS molded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 KG tested in accordance to ASTM D 4280 Type H and complying to specifications of category A of MORTH circular No RW/NH/33023/10-97-DO III dated 11.06.1997. The height, width, and length shall not exceed 50mm, 100mm, and 100mm and with minimum reflective area of 13 sqcm on each side and the slope to the base shall be 35 +/- degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2mm and height not less than 30 +/- 2mm) from the body is to be a minimum value of 700 Kgf. Fixing will be by drilling holes on the roads for the shanks to go inside, without nails and using epoxy resin based adhesives as per manufacturers recommendation and complete as directed by Engineer-in-charge. The contractor shall submit 2 years pre qualified waranty certificate from the manufacturer for satisfactory field performance during the time of bid submission. Make - SAFE ZONE, DARK EYE
S & F of round pipe delineators of 75mm dia and 1200mm long with protective mesh fixed on the ground after necessary excavation and earthwork in any type of soil, embedding the delineator on the ground with & including PCC (1:2:4) type B-1 using 20mm graded stone aggregate (minimum PCC block size 200mm x 200mm x 200mm for proper grouting) complete all as specified and directed. Make - SAFE ZONE, DARK EYE
S & F dual directional rumble strips made of ABS (Acrylonitrile Butadiene Styrene) material of size 250mm x 150mm duly reflectorised with highly reflective twelve nos imported glass panels on both side (6x2) and to be fitted with 2 nos steel pin of 120mm x 12mm size and suitably epoxy A&B complete all as specified and directed by Engineer-in-charge. Make - SAFE ZONE, DARK EYE
S & F retro reflective sign board of size 1.20m x 0.90m made up out of stainless steel pipe 35mm dia frame and 2mm thick aluminium sheet, face to be covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type -IV of ASTM-D 01 in blue and silver white or other colour combination including subject matter message (bi-lingual), symbols and borders etc as per IRC:67-2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with sized aluminium alloy rivets @20mm c/c to back support and welded to poles 2.10m high of stainless steel 50mm dia pipe welded with MS base plate of size 100 x 100 x 5mm and grouted in PCC complete all as specified and directed by Engineer-in-charge.
S & F waterproof, energy saving and eco-friendly DHRUV solar road stud made out of aluminium alloy shell powered by solar cells and panels. Ideal signal product for highways, parking lots, roads, and similar isolated or stand alone traffic applications. Technical Specifications:- 1. Aluminium alloy shell, 2. solar panel mono-crystalline solar 2.4V / 0.3 watt, 3. One Ni-Mh or Ni-cd rechargable battery, 4. Six super bright LED's 5. Colour : yellow, red, blue, green, and white, 6. working time : 50 to 60 hours successively after the battery is fully charged, 7. Charging time: five to six hours / day, 8. Solar energy based power source, 9. Brightness sensitive auto-switch, automatically turns on at niht and turns off at drawn , 10. High visibility LEDs help ensure easy and safe night driving, 11. Ideal for highways, parking lots, roads and similar isolated or stand alone traffic applications, 12. Size: 125x125x25 mm with shank of 60mm. complete all as speciifed and directed by the Engineer-in-Charge. Make :- SOLAR DHRUV DA 110.
S & F flexible polycarbonate (virtually unbreakable) reflective type convex mirrors, 1000mm size of mirror, outdoor type, equipped with and including adjustable swivel and mounting bracket for infinite adjustment, body of ABS / fiber / plastic complete with and incl mounting hardware and 76mm stainless steel pipe complete all as speciifed and directed by the Engineer-in-Charge. Make :- GOGIA PLASTICS, SUCCESS UDYOG, SAFE ZONE
Total amount of SCHEDULE 'A' PART-VI A (CABLE NETWORKING) (For details see Schedule 'A' Part-VI A in PDF folder)
SCHEDULE 'A' PART-VI B (CABLE NETWORKING)
M&L for Telephone socket RJ-11 with metal flush box and cover plate complete all as specified and directed.
M&L for TVsocket with metal flush box ith metal flush box and cover plate complete all as specified and directed.
M&L for providing,drawing,connecting and testing of telephone wire 20 pair,0.5 mm dia tinned annealed high conductivity copper conductor with high density polythene insulation,paired,polyster tapped and FR PVC sheathed complete all as specified and directed.
S&F co-axial cable RG-11 complete all as specified and directed..
Total amount of SCHEDULE 'A' PART-VII A (COOLING APPLIANCES) (For details see Schedule 'A' Part-VII in PDF folder)
SCHEDULE 'A' PART-VII B (COOLING APPLIANCES)
Supply and Installation Refrigerator-195 litres non CFC refrigerant type electric driven(single phase) of the following capacity ,frost free,double door BEE 5 star rated complete all as specified and directed. Make:- LG/Samsung/Voltas
Supply and Installation Refrigerator-310 litres non CFC refrigerant type electric driven(single phase) of the following capacity ,frost free,double door BEE 5 star rated complete all as specified and directed. Make:- LG/Samsung/Voltas
S&F automatic operation single phase stablizer,naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 1 KVA complete all as specified and directed.
S&F automatic operation single phase stablizer,naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 2 KVA complete all as specified and directed.
S&F automatic operation single phase stablizer,naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 4 KVA complete all as specified and directed.
S&F water heater storage type,suitable for AC,electric supply,single phase,50 Hz,stainless steel water tank complete of capacity 25 litres complete all as specified and directed.
S&F desert cooler heavy duty electric driven(S.P),230 volts,AC,air flow capacity 3000 Cum/Hr,blade size 406/16 mm ,PVC body,3 speed,1400 RPM,160 watt,45 ltrs water tank cap,motorisedloures movement,top water inlet complete with pump & motor all as directed. Make :- Sumo New and equivelent complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-VIII (MONKEY GUARD FOR PVC WATER TANKS) (For details see Schedule 'A' Part-VIII in PDF folder)
Total amount of SCHEDULE 'A' PART-IX (RETAINING WALL) (For details see Schedule 'A' Part-IX in PDF folder)
Total amount of SCHEDULE 'A' PART-XA (EXTERNAL ELECTRIFICATION) (For details see Schedule 'A' Part-XA in PDF folder)
SCHEDULE 'A' PART-XB (EXTERNAL ELECTRIC SUPPLY)
Supply and install A.C. 3 phase, 200 KVA capacity transformer copper wound, step-down outdoor type, 11000/433 Volts as per IS-1180-part-I:2014 at no load, oil immersed naturally cooled with external cooling tubes/fins core type, Delta connection on primary (HV side) in accordance with vector group DY-11 with neutral brought on secondary (LV side) and having tappings at + 2.5, + 5.0%, + 7.5% be changed by means of hand operated “OFF LOAD” Tap changer gear complete including testing and comperising with followings :-
HT bushing suitable for 11 KV complete with all accessories housing in sheet steel enclosure - 03 nos.
LT bushing suitable for 1100V complete with all accessories housing in sheet steel enclosure - 04 nos.
Oil conservator with filter type drain valve and oil level gauge.
Dehydrating breather with first fill dehydrating agent
Explosive vent.
Thermometer pocket on tank cover.
One number 100mm dial type thermometer, vapour pressure type , having range 0-120 degree centigrade with maximum reading pointer, Max. temperature indicator and resting device.
Rating plate with terminal marking.
Two Nos. earthing, terminals on tank and cover to facilitable fixing of 32mm x 6 mm strip.
Oil level gauge.
Oil drain filter valve.
Lifting lugs.
Oil filter hole with cap /plug with connection complete.
Air release valve plug.
Four plain solid cast steel detachable rollers.
First fill of fresh trams former oil conforming to relevant I.S. and tested upto 40 KV dielectric strength.
Platform of Size 3.5 x 3.5 x 2.0m height from ground level with stairs including excavation, PCC 1:5:10 type E2 in foundation, brick workin CM 1:6, PCC 1:2:4 type B1 in coping, plastering 10mm thick in CM 1:6 on brick/concrete surface and on top covered with GI chain link fencing 1.20m high gate of mesh size 50 x 50mm and GI wire dia 3.15mm incl suitable size of angle Iron, nuts & Bolts etc,
M& L for shiffting /relocated and install , old exsiting , transformer step up/step down, outdoor type complete of capacity 200 KVA including suitable size of PCC foundation
Supply, installing, testing and commissioning of LT distribution panel board Factory made, powder coating ,cubical, outdoor type fabricated with angle iron / flat iron frame work , enclosed with 3.15mm thick sheet steel with independent compartment for each feeder , bus Bar chamber, cable tray for cable entry, 800 Amps capacity, four wire, TPN, with colour indication,Al bus bar 800 Amps capacity mounted on epoxy insulators of 1100 volt grade. Out going of respective capacities . Panel should have front and back openable hinged door for each compartment with locking arrangement and common openable hinged door from rear side, floor mouting type, comprising the adequate arrangement to fix the following incoming and out going MCCBs etc and connecting the cables with the incoming / out going feeders including cable glands and cable lugs,nut bolts and washers complete, all as specified and directed,comprising with the following accessories.
INCOMING
a) MCCB 400 Amps, 4 pole, 25KA/50 KA -01 No;
d) Indicator lamp LED type - 03 Nos.
OUTGOING
a) MCCB 200 Amps, 4 pole, 16 KA -03 No;
b) MCCB 100 Amps, 4 pole, 16 KA -02 Nos;
c) MCCB 63 Amps, 4 pole, 16 KA -01 Nos;
Supply, installing, testing and commissioning of LT distribution panel board Factory made, powder coating ,cubical, outdoor type fabricated with angle iron / flat iron frame work , enclosed with 3.15mm thick sheet steel with independent compartment for each feeder , bus Bar chamber, cable tray for cable entry, 400 Amps capacity, four wire, TPN, with colour indication,Al bus bar 400 Amps capacity mounted on epoxy insulators of 1100 volt grade. Out going of respective capacities . Panel should have front and back openable hinged door for each compartment with locking arrangement and common openable hinged door from rear side, floor mouting type, comprising the adequate arrangement to fix the following incoming and out going MCCBs etc and connecting the cables with the incoming / out going feeders including cable glands and cable lugs,nut bolts and washers complete, all as specified and directed,comprising with the following accessories.
INCOMING
a) MCCB 125 Amps, 4 pole, 25KA/50 KA -01 No;
d) Indicator lamp LED type - 03 Nos.
OUTGOING
a) MCCB 100 Amps, 4 pole, 16 KA -01 No;( for pump)
b) MCCB 63 Amps, 4 pole, 16 KA -01 Nos; (for Chloronum plant)
c) MCCB 63 Amps, 4 pole, 16 KA -01 Nos;( street Light)
d ) MCB 40 Amps, 4 pole, 10 KA -01 Nos;( Blding Light )
Supply, Fabrication, Installation, Testing & Commissioning {CPRI approved} 440V AC LT APFC Panel, indoor/outdoor type, compartmentalized, Modular, Indoor Type in 3.15MM CRCA Sheet of Appropriate Size, Front Operatable Double Doors, Foont & Back Openable only, Dust & vermin proof, cable Entry through 3.15 MM CRCA Gland Plates - Bottom only, Powder Coated after 7-Tank Pre-treatment process - Siemens Grey Shade on Body/Doors & Orange Shade on Mounting/Gland Plates + Incomer Doors, 3Phase HR Sleeved Color CodedAluminium Main Busbar of 200A - 3 Nos with Transparent FRP Covers & on SMC/DMC Supports, 25x3MM Aluminium Earth Busbar running across the whole length of the LT Panel with 2Nos. Studs at both the side-ends, Lifting arrangement/ Hooks at the top, Wiring with Appropriate Size of Copper Industrial Cables, Black Painted Base Frame - 40x40x3MM MS Angle Frame, Cable Glandes brass Crommium plated of different sizessuitabl for incoming & outgoing ACB and MCCB's and fitted with following specified items:-
(i) Rating - 30 kVAr APFC Panel (Without Harmonic Block Reactors) with MCCB 63 Amps, 4 pole, 16 KA -01 Nos;
ii) Capacitors -
a) 440V AC TP MDXL type Heavy Duty low loss Capacitors in Cylindrical/Square body of following ratings:
10kVAr x 2Nos + 5kVAr x 2 Nos. (Schneider/ABB/Siemens Make)
iii) 415V AC TP Microprocessor Based Intelligent PF Correction Relay/Controller 17 Stage with 3CT sensing capability (EPCOS/ Schneider/ABB/Siemens Make)
iv) for 10kVAr Capacitor Banks - 2Nos
v) for 5kVAr Capacitor Banks - 2 Sets
vii) Cooling of Capacitor Banks - 1 Set
viii) Metering - 1Set
Flush Type 96x96MM AC Ammeter (-/5A) & Voltmeter (0-500V) with Inbuilt Sector Switches, LED Display - 1Each, 3 Nos CTs Cast Resin/ Moulded Case 250/5A for Ammeter, 3 Nos CTsCast Resin/ Moulded Case for IMFCR as per the load of Main Transformer Panel, RYB Phases + MCCB On/Off/Trip Indications LED Type, Control Fuses with 4A Glass Carrier Fuses - 35 Nos, CFL 14/15W SP 220V AC for Panel Lighting with door Limit switch - 2Sets, Panel Space Heaters with Thermostats and MCB DP of appropriate rating.
1. All MCCB and MCBs must be fixed vertically in panel.
2. As per CPRI Approved must be write on right top corner with reveted separate plate.
3. A separate locking arrangement (sliding bolt type) must be made in panel.
S&F out door type bus bar chamber,415 volts,out door padestial type,3.15 mm thick factory made ,powder coated of size 750 mmx750 mmx450 mm including space for MCCB 400 to 63 Amps 4 pole with Al TPN bus bar 600 Amps cap complete with locking arrangement.
Supply and fix time switches 415 V three Phase of 20 Amp rating with contractor fitted inside steel enclosure.
S&F Intergral LED street light luminair fitting comprising of epoxy powder coated hsg, enclosed with glass cover in frame 70 watt IP65 protection complete all as specified and directed.
S&F bracket made out of GI tubing, light grade, 50 mm dia, incl clamp,nuts,bolts & washers etc as directed
S&F sheet metal enclosure pole box made SMC/FRP of size 300 x 200x150 mm 415 volts TPN Single door with 20x3 mm Al busbar of suitable size complete with MCB SP 10 Amp with 40 x 5 mm MS clamp,nut,bolts washer etc.
Supply and laying cable XLPE PVC insulated PVC sheathed, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm, 2 core complete all as specified and directed.
All same as above item but 10 sqmm,2 core.
All same as above item but 16 sqmm, 4 core.
All same as above item but 35 Sqmm 3.5 core.
All same as above item but 50 Sqmm 3.5 core.
All same as above item but 70 Sqmm 3.5 core.
All same as above item but 95 Sqmm 3.5 core.
All same as above item but 120 Sqmm 3.5 core.
All same as above item but 185 Sqmm 3.5 core.
All same as above item but 240 Sqmm 3.5 core.
Earthing complete with galvanized mild steel earth plate ( electrode) 600 x 600 x 6.00mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 4 mm dia GI wire as earth wire welded and riveted to earth plate at one end and connected to main switch / control switch of the building at another end GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto main switch / control ofthe building including 20 mm dia bore GI Pipe ' light grade' as water pipe from earth chamber to upper edge of earth plate, all as shown on electriclal plate no 3 of MES schedule 2009 part I (specifications) and connected to main switch board / main DB's / earthing test point, CI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 using 20MM graded stone aggregate as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly reinforced with MS round bars 6 mm dia @ 150 C/c both waysand with 10 mm dia MS bar in lifting handle , excavation earth work including laying the GI pipe concealed in floor / wall all as described in electrical plate no 3 of SSR Part I Notes:- 1) On testing after completion of job, if desired earth resistance (i.e, less than one ohm ) is not obtained, the earthing shall be re done by the contractor without any extra cost of government. 2) Bifurcation of quantities a) External electric supply - 24 b) Internal Electrification - 69
Total amount of SCHEDULE 'A' PART-XI A (EXTERNAL WATER SUPPLY) (For details see Schedule 'A' Part-XI A in PDF folder)
SCHEDULE 'A' PART-XI B (EXTERNAL WATER SUPPLY)
Supply,laying in trenches,jointing and testing of centrifugal cast (Spun) ductile iron(DI) pressure pipes with socket and spigot ends confirming to IS-8329/2000 in lengths 6.0/5.5/4.0 mtrs of classificatio K-9 suitable and including rubber tyton joints(rubber gasket 'D' joint) with cement mortar lining inside the pipe line complete all as specified and directed of the following sizes.
a) 200 mm dia.
b) 150 mm dia.
c) 100 mm dia.
M & L for Cast iron Air release valves with two air out lets, 80mm dia bore and fixing up in rising mains complete all as specified and directed..
Construction of brick massonary valve pit including necessory excavation and earth work,disposal of surplus soil,brick,PCC in foundation,angle iron frame size (40x40x6 mm),hold fast,MS sheet cover 3 mm thick with handle and locking arrangement and cement plaster etc. all as directed of the following sizes:-
a) 1000x1000x1000 mm.
b) 750x750x750 mm.
c) 500x500x500 mm.
(a) From ground level upto a depth of 50 Mtr including making of initial bore well manually.
(b) From 51 Mtr to a depth of 100 Mtr.
(c ) From 101 Mtr. To a depth of 190 Mtr.
Extracing of any size of casing pipe lowered for construction of tube well starting from bottom of bore hole and taking on ground after completion tube well, stacking them complete all as specified and directed. Note:- (a) Casing pipe extracted shall re-main contractor's property as these are brought at site by the contractor for construction of tube well. (b) Depth of extractor shall be measured after cleaning of bore irrespective of and no & size of casing pipe.
Supply and fixing with 250 mm nominal bore housing pipe & lowering in position MS ball plug with strong puling & lifting hook all as specified
Supplying & packing pea gravel of size 3 mm to 10 mm to a packed thickness of 50 mm (approximatly) all as specified & directed.
S&F in position MS Cap with internal thread & locking arrangement suitable for housing pipe of 250 mm nominal bore complete all as specified .
S&F in position MS holding down clamps (set of 2 Nos) made out of 150x15 mm MS flat iron & length upto 1.25 Mtr bent ot shape as specified complete with 4 nos nut, bolts, washers 16 mm dia for holding 250 mm dia housing pipe complete all as specified and directed.
S&F centre made of MS Flat Iron size 40 x 6 mm at an interval of 6m depth for 250 bore pipe complete all as specified and directed by Engineer in charge.
Developing the tube well firstly by means of pumping unit using firstly air compressor unit of asequate capacity not less then 250 PSI hten by over pumping, untill asnd free water is obtained & testing the yield for duration as under:-
(a) With air compressor first 24 hours.
(b) With air compressor 24 hours to 72 hours for tube well..
(c ) Over pumping with help of suitable size of pump & accessories & standby by DG Set in order to ensure continuous pumping fpr 24 hours & yield test by "V" notch method/Orifice method (rate quote will include provision of all T&P required for this test to be provided by the contractor)
Supply sample box of strata sample made out of teak wood planks 25 mm thick size of board 900 mm x 400 mm and 150 mm wide and size of sample bits 100 mm x 100 mm with front provided with glazed hinged dhutterd 900 mm x 400 mm with hasp & dtaples & painted for strata sample asa found while drilling tube well.
M&L foundation casing pipe with PCC brick work and plastring etc. all as specified and directed as under: (a) M&L PCC 1:3:6, 150 mm thick below GL in foundation around casing pipe but excluding ground layer (1.5 M as outer dia) all as specified and directed. (b) M&L brick work as in half brick wall in CM 1:4 in circular shape (2 walls as inner circle & 1 as outer circle , hight of wall 1.3 M above and 0.7 M below ground level) all as specified and directed. (c ) Two nos 80 mm dia GI pipe length 2 Mtr with plug cap to be fixed in open end out side the PCC for refilling of pea gravel
Supply, testing. Installation & commissioning of submerssible pump set three phase of suitable capacity of discharge 570 ltr/minute and head 110 mtr Electric driven suitable for operation AC 415 Volts, 50 Hz.
Supply, Fixing, jointing and testing submersible cable, flat, copper conductor, stranded, PVC insulated and PVC seathed, 1100 Volts, 3 core, 16 sqmm nominal area ISI marked. The cable shall be fixed and lowered with column pipe using suitable mild steel clamps stainless steel bolts, nuts and two numbers washers using two nos clamps for every column pipe of 3.00 Mtr length complete all as specified and directed.
Supply, installation , testing and commissioning vaccume operated cylinder mounted gaseous chlorination plant confirming IS 10553 part -2 having 25 to 500gm/hr of chlorine gas for chlorination of water along with its complete accessories like vaccume regulator with built in safety valve filter, compound press able gauge with silver dia pragm and measuring glass with chlorine does rate adjusting valve of PMMA materials (cnical shaped) with residual pressure preservation feature, ejctor, non-return valve,additional chek valve (Back stop) 5 Mtr quick fixing PE vaccum tubing, mounting spanner, amonia solution, PVC re-inforced pipe ect all as specified and directed.
Supply and transporting chlorine gas cylinder ISI marked dully filled of 100 Kgs capacity with 100 Kgs chlorine gas fitted with chlorine gas valve, cylender cap etc conferming to IS-3196 Part- IV along with permission for filling from CCE Nagpur and manufacturers Hydraulic test certificate complete all as specified and directed.
Supply, jointing and lowering galvanized (Hot Dip) MS ERW type 7.0 mm wall thickness and 10 mm thick flange duly welded column pipe 3.0 Mtr length each complete with rubber gasket nut bolts spring washers bore of colmn pipe 100 mm all as specified and directed.
Supply, fixing and connecting water pressure guage 100 mm dia bursen type with siphon tube connection stainless steel needle valve and welding of suitable size of socking in the delivery pipe for mounting of the above.
Supply and fixing of MS clamps made out of MS flat iron 125 mm wide x 800 mm long 12 mm thick duly ribbid with MS flat iron 50 x 6 mm in center with 4 Nos holes of 18 mm dia, 4 Nos bolts nuts and washers 80 x 15 mm dia stainless steel (suitable for lowering and lifting of pump set) all as specified and directed.
Supply and fixing testing CI Air release valve with double acting air balls for fixing with 80 mm pipe including bolts nuts washers and jointing materials etc all as specified and directed.
Supply, installation , testing and commissioning of LT distribution panel board, factory made, indoor type cubical type, front and rear openable with locking arrangement, fabricated with angle iron frame work enclose with 2 mm thick sheet with independent compartment for each feeder, busbar chamber,cable tray for cable fully comparted type, 400 Amps rating capacity four wire TPN with colour indication, mounted on epoxy insulators of 1100 Volts.Out going respectivew capacity aluminium busbar terminations shall be left at cable alley 01 set at each door for each compartment with locking arrangement and common openable hinged door from rear side floor mounting type including power coated painting conferming to IP-42 protection and as per IS comprising following incomming and outgoing feeders:-
OUTGOING :- 1. MCCB 3 pole 415 volt, 100 Amps rating 25 ka - 01 No 2. MCCB 3 pole 415 volt, 32 Amps rating 10 ka - 02 No 3. Timer switch modular type 230 Volt, 5 Amp including wiring complete Make Legrand Cat part no -04767 Astrorex - 01 No 4. Internal wiring of panel board with proper size copper conductor including insulating materials. 5. CP Brass cable glands for all incomming and outgoing cables 6. Space for auto transformer starter type 3 phase. :- 01 7. Fully automatic star delta starter (FASD) AC 415 Volt 3 Phase 35 HP 01 Nos 8. Single phase priventer. :- 01 Nos. 9. Cable lugs for all incomming and outgoing cables.
M & L for Cutting of exisiting CI/DI rising main pipe line and connecting tube well line, by inserting CI tee of size 300x300x200 mm dia/bends and sluice valve etc. all as directed. Note :- Sluice valve/Tee/bends etc. shall be paid and measured separately under respective items.
Re laying CI/MS/GI pipe line including cutting , all fittings with spigot and socket ends and lead/tyton / flanged/ welded joints and recovering lead and removing all as specified & directed of the following sizes:- Note:- 1) Excavation and earthwork shall be measured seperately. 2) Old pipe as obtained from dismantling shall be relayed as directed by engineer in charge.
a)200 mm dia.
b) 100 mm dia
c) 80 mm bore.
d) 25 mm bore.
Total amount of SCHEDULE 'A' PART-XII A (AREA ILLUMINATION) (For details see Schedule 'A' Part-XII A in PDF folder)
SCHEDULE 'A' PART-XII B (AREA ILLUMINATION)
S&F LED Flood light 150 Watt with IP 66 Protection complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-XIII (AREA DRAINAGE) (For details see Schedule 'A' Part-XIII A in PDF folder)
Total amount of SCHEDULE 'A' PART-XIV A (FENCING, GATE, AND BOUNDARY WALL) (For details see Schedule 'A' Part-XIV A in PDF folder)
SCHEDULE 'A' PART-XIV B (FENCING, GATE, AND BOUNDARY WALL)
Construction of steel gate 5.50 mtr wide (clear disatance the pillar) 2.10mtr height fabricated with angle , sheet or other section, with gusset plate rails braces, etc including drilling for sheet covering to be prepared for hanging and other fittings with and including necessary excavation and finishing complete as per drg No TD/20 sheet 1/4 to 4/4 all as specified and directed.
Construction of steel gate 1.20 mtr wide (clear disatance the pillar) 2.10mtr height fabricated with angle , or other section, including necessary excavation and finishing complete as per drg No TD/241 of CEBZ all as specified and directed.
Total amount of SCHEDULE 'A' PART-XV A (SEWAGE DISPOSAL) (For details see Schedule 'A' Part-XV A in PDF folder)
SCHEDULE 'A' PART-XV A (SEWAGE DISPOSAL)
M&L for Construction of Septic Tank 150 users with brick masonry, PCC in foundation 1:4:8, floor, cover slab, including sludge chamber, CI vent pipe, CI cowl inlet and outlet pipe, RCC baffle wall and all necessary earthwork complete all as specified and directed.
M & L for Construction of Septic Tank 100 users with brick masonry, PCC in foundation 1:4:8, floor, cover slab, including sludge chamber, CI vent pipe, CI cowl inlet and outlet pipe, RCC baffle wall and all necessary earthwork complete all as specified and directed.
M & L for Construction of Septic Tank 25 users with brick masonry, PCC in foundation 1:4:8, floor, cover slab, including sludge chamber, CI vent pipe, CI cowl inlet and outlet pipe, RCC baffle wall and all necessary earthwork complete all as specified and directed.
M & L Soakage wells excavation in any type of soil foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M-25 Concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25/SFRC cover interconnecting pipes of RCC/DWC complete filed with brick bats of size 3.60m x 3m complete all as specified and directed.
M & L Soakage wells excavation in any type of soil foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M-25 Concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25/SFRC cover interconnecting pipes of RCC/DWC complete filed with brick bats of size 3m x 3m complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-XVI A (SOLAR WATER HEATER) (For details see Schedule 'A' Part-XVI A in PDF folder)
Total amount of SCHEDULE 'A' PART-XVII A (LIGHTNING CONDUCTOR) (For details see Schedule 'A' Part-XVII A in PDF folder)
SCHEDULE 'A' PART-XVII B (LIGHTNING CONDUCTOR)
Earthing complete with galvanized mild steel earth plate ( electrode) 600 x 600 x 6.00mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32x6mm GI strip earthlead welded and riveted to earth plate at one end and connected to main switch / control switch of the building at another end GI earth wire encased in and including 20 mm dia GI 'light grade' as water pipe from earth chamber to upper edge of earth plate, all as shown on electriclal plate no 3 of MES schedule 2009 part I (specifications) and connected to main switch board / main DB's / earthing test point, CI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4type B-1 duly reinforced with MS round bars 6 mm dia @ 150 c/c both ways and with 10 mm dia MS bar in lifting handle , excavation , earth work including laying the GI pipe concealed in floor / wall all as described in electrical plate no 3 of SSR Part I Notes:- 1) On testing after completion of job, if desired earth resistance (i.e, less than one ohm ) is not obtained, the earthing shall be re done by the contractor without any extra cost of government. 2) Bifurcation of quantities a) External electric supply - 44 b) External Water Supply - 02 c) Lightning Conductor - 12 d) Stand by DG Set - 04
SCHEDULE 'A' PART-XVIII (STANDBY DG SET)
Supply ,installation ,commission and testing totally enclosed type (silent operation with canopy,CP CB approved ),static type Diesel Engine driven,Generating set of 100 KVA capacity confirming to BS-2613/IS -4722, 4 wire 50 HZ 415 Volts supply under NTP conditions when running at 1500 RPM complete including Engine Alternator mounted on common base plate of rigid fabricated mild steel base frame all as recommended by manufacturer and having following provisions all as specified and directed . The silent canopy shall be as per the Central Pollution Control Board norms . The silensor canopy shall be manufacturerd by the manufacturer of the engine itself . The make and model of generator set to be installed with engine details ,alternator specifications and specification of silensor canopy shall be got approved from GE before order is placed by the contractor to the manufacturer. (Signal Center=01No )
(A) Alternator:- Alternator shall be of capacity of 100 KVA net out put at work site after considering derating factor as per MSL height and NTP conditions as applicable at power factor .8,AC , 3 phase , 4 wire, AVR system, screen protected . Ball / roller bearing with damp proof copper windings on each pole to base as per IS-1722-1970 complete all as specified .
( B ) Diesel Engine :- Diesel shall be of adequate capacity suitable for above alternator after derating factor as per MSL hight and temperature for work site and as per relevant IS code having provision of coupling shaft to drive the above altemator independtly after considering power losses in all the accessories forming part of the set i.e. couplings any type FIP , water cooler, direct injector ( if provided ), fan etc. Engine should be multistage, vertical multi cylinder water cooled, 4 stroke, direct injection cold starting , RPM 1500, industrrial type standard accessories complete in all respect including all provisions as recommended by manufacture and following provisions complete all as specified and directed. (Note: DG set will be conforming to notification of Min of Environment date 17 may 2002):-
(i) Fly wheel with housing .
(ii) Air cleaner dry type
(iii) Corrosion resisiters.
(iv) fuel filter, Oil filter
(v) FIP system including pump injectors solenoid controls , nozzles, govenors etc
(vi) Radiiator including water pump with fan
(vii) Cylinder with buffers, tail pieces duly insulated with asbestos/ lagging and sufficiently extended to carry exhaust outside the DG Set building.
(viii)Electrically starting system consisting of the follwing items :-
(a) Lead acid battery 12/24 volts , 180 AH = 02 Nos. initially charged Make :- Exide/Prestolite/ AMCO ( Maintenance free type)
(b) Self Starter.
(c)Alternator 12/24 volts DC complete with holding clamp.
(d) Start / Stop push button ,ignition switch with key system.
(e) Battery charging system including regulator and generator / alternator .
(ix) Engine shall be with turbo charger.
(x) Engine protection device against low lubicating oil pressure, high water temperature ,and high oil temperature ,over speeding of engine etc.
(xi) Water temperature gauge, oil temperature gauge, oil puessure gauge ammeter for display charging + Amps etc.
(C) ACCOUSTIC ENCLOSURE FOR DG SET :- Supply and fixing accustic enclosures suitable eof 100 KVA capacity diesel Generator set duly fabricasted of channel and CRCA sheet 16SWG of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers /outlet. ventilation system etc . complete as per manufacturers instructions with wiring and lighting arrangements duly painted of three coats of dulux gloss synthetic enamalled paint over a primer coat or as directed of suitable size all as required at site and comprising of the following :-
(i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section . (ii) Structure heavy duty rectangular MS box channel . (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks . (iv) Out side cover: Made out of CRCA sheet 2 mm thick. (v)Accustic insulation ( side &Top ) sound proofing minerla rock wool slab of density 96Kg/m3confirming to IS 0183 thickness 100mm covered by fire Resistant fiber tissue as per manufacturer recommandation .Test report from original manufacturer to be submittedbefore incorporation in the work for authenticity of material . (vi) Inside cover : CRCA perforated sheet 0.6mm thick powder coated . (vii) Inspection port : Aluminium frame with double wwalled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel .
AMF logic :The AMF panel shall be provided with micro processer based programmable logical control system of Make -C&S (LG) /UTOPIA /SIEMENS. The control system will have the fillowing option:- (a) Start/ stop settings including delay and timing setting duly programmable. (b) programmable timing for idle running . (c) Auto/ manual option for each contractor . (d) Self starting kiks for three times or as per programme . (e) Alarm for any fault with buzzer and indicating lamp . (f) One main supply voltage monitor . (g) One alternator supply voltage monitor . (h) One set of DC control relays and timers. (j) One set of control relays for the automatic control system .
(E) RCC FOUNDATION:- RCC Fuoundation M 20(as per manufacturer design) ,250 mm overall height, 100mm above floor level and 150 mm below floor level of required size. (Make of Engine :-Cummins/Kirloskar/ Ashok leyland /Ruston/Greaves. (Make of Alternator :-Kirloskar/Jyoti/Stam Ford,Alston, Electric, Jyoti .
(F) Acoustic Louvers / Attenuators at Air inlet/outlet :-The acoustic louvers provides excellent sound attenuation and good weather protection. Single blade and chevron blade louvers are manufacturefrom 16 SWG CRCA sheet top section with an acoustic in fill of resin bonded mineral rock wool has a density of 96 Kg/m3 .The under section is formed from 18 SWG CRCA performed sheet after covering with resistance tissues to prevent fire migration or by means of acoustic lined ducts.
(G) FUEL TANK :- One No of sheet metal steel tank of suitable capacity of hold diesel sufficient for 12 hours running at full load, mounted on angle iron frame including the following:- (i) Level indicator to indicate level of diesel in tank. (ii) Drain plug with 2.0 mtrs pipe for draain oil. (iii) fuel strainer. (iv) Pipe for fuel. (v) Air vent. (vi) Mannually operated one no. fuel pump.
(H) INSPECTION PORT :- Aluminium box frame with double welded glass fix type sealed with neoprene rubber gasket, for viewing instrument panel.
(J) VENTILATION :- Forced with suitable fan. (a) supply fan 700mm dia axial flow fan driven by 2 HP 1440 RPM with starter make : KEC/ GEC/ABB. (b) Exhaust Fan 600mm dia axial flow fan driven by 1.5 HP motor 1440 RPM with starter make : KEC/GEC/ABB.
(K) WIRING AND LIGHTING :-PVC copper wire concealed in flexible conduit provided with florescent tube light and MCB. (a) Earthing panel (Neutral body). (b) Control Panel . © Cable leads for batteries. (d) Power cable to euipment. (e) Self Starter
NOTE :- (a) Generating set will be placed on suitable foundation as recommended by manufacturer .and cost thereof shall be included on the prices quoted . (b)Tools shall be supplied as per manufacturer,s instructions and cost thereof shall be included in the price quoted .
Supply ,installation ,commission and testing totally enclosed type (silent operation with canopy,CP CB approved ),static type Diesel Engine driven,Generating set of 62.5 KVA capacity confirming to BS-2613/IS -4722, 4 wire 50 HZ 415 Volts supply under NTP conditions when running at 1500 RPM complete including Engine Alternator mounted on common base plate of rigid fabricated mild steel base frame all as recommended by manufacturer and having following provisions all as specified and directed . The silent canopy shall be as per the Central Pollution Control Board norms . The silensor canopy shall be manufacturerd by the manufacturer of the engine itself . The make and model of generator set to be installed with engine details ,alternator specifications and specification of silensor canopy shall be got approved from GE before order is placed by the contractor to the manufacturer. (Tube well=01No )
(A) Alternator:- Alternator shall be of capacity of 62.5 KVA net out put at work site after considering derating factor as per MSL height and NTP conditions as applicable at power factor .8,AC , 3 phase , 4 wire, AVR system, screen protected . Ball / roller bearing with damp proof copper windings on each pole to base as per IS-1722-1970 complete all as specified .
( B ) Diesel Engine :- Diesel shall be of adequate capacity suitable for above alternator after derating factor as per MSL hight and temperature for work site and as per relevant IS code having provision of coupling shaft to drive the above altemator independtly after considering power losses in all the accessories forming part of the set i.e. couplings any type FIP , water cooler, direct injector ( if provided ), fan etc. Engine should be multistage, vertical multi cylinder water cooled, 4 stroke, direct injection cold starting , RPM 1500, industrrial type standard accessories complete in all respect including all provisions as recommended by manufacture and following provisions complete all as specified and directed. (Note: DG set will be conforming to notification of Min of Environment date 17 may 2002):-
(i) Fly wheel with housing .
(ii) Air cleaner dry type
(iii) Corrosion resisiters.
(iv) fuel filter, Oil filter
(v) FIP system including pump injectors solenoid controls , nozzles, govenors etc
(vi) Radiiator including water pump with fan
(vii) Cylinder with buffers, tail pieces duly insulated with asbestos/ lagging and sufficiently extended to carry exhaust outside the DG Set building.
(viii)Electrically starting system consisting of the follwing items :-
(a) Lead acid battery 12/24 volts , 180 AH = 02 Nos. initially charged Make :- Exide/Prestolite/ AMCO ( Maintenance free type)
(b) Self Starter.
(c)Alternator 12/24 volts DC complete with holding clamp.
(d) Start / Stop push button ,ignition switch with key system.
(e) Battery charging system including regulator and generator / alternator .
(ix) Engine shall be with turbo charger.
(x) Engine protection device against low lubicating oil pressure, high water temperature ,and high oil temperature ,over speeding of engine etc.
(xi) Water temperature gauge, oil temperature gauge, oil puessure gauge ammeter for display charging + Amps etc.
(C) ACCOUSTIC ENCLOSURE FOR DG SET :- Supply and fixing accustic enclosures suitable eof 100 KVA capacity diesel Generator set duly fabricasted of channel and CRCA sheet 16SWG of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers /outlet. ventilation system etc . complete as per manufacturers instructions with wiring and lighting arrangements duly painted of three coats of dulux gloss synthetic enamalled paint over a primer coat or as directed of suitable size all as required at site and comprising of the following :-
(i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section . (ii) Structure heavy duty rectangular MS box channel . (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks . (iv) Out side cover: Made out of CRCA sheet 2 mm thick. (v)Accustic insulation ( side &Top ) sound proofing minerla rock wool slab of density 96Kg/m3confirming to IS 0183 thickness 100mm covered by fire Resistant fiber tissue as per manufacturer recommandation .Test report from original manufacturer to be submittedbefore incorporation in the work for authenticity of material . (vi) Inside cover : CRCA perforated sheet 0.6mm thick powder coated . (vii) Inspection port : Aluminium frame with double wwalled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel .
AMF logic :The AMF panel shall be provided with micro processer based programmable logical control system of Make -C&S (LG) /UTOPIA /SIEMENS. The control system will have the fillowing option:- (a) Start/ stop settings including delay and timing setting duly programmable. (b) programmable timing for idle running . (c) Auto/ manual option for each contractor . (d) Self starting kiks for three times or as per programme . (e) Alarm for any fault with buzzer and indicating lamp . (f) One main supply voltage monitor . (g) One alternator supply voltage monitor . (h) One set of DC control relays and timers. (j) One set of control relays for the automatic control system .
(E) RCC FOUNDATION:- RCC Fuoundation M 20(as per manufacturer design) ,250 mm overall height, 100mm above floor level and 150 mm below floor level of required size. (Make of Engine :-Cummins/Kirloskar/ Ashok leyland /Ruston/Greaves. (Make of Alternator :-Kirloskar/Jyoti/Stam Ford,Alston, Electric, Jyoti .
(F) Acoustic Louvers / Attenuators at Air inlet/outlet :-The acoustic louvers provides excellent sound attenuation and good weather protection. Single blade and chevron blade louvers are manufacturefrom 16 SWG CRCA sheet top section with an acoustic in fill of resin bonded mineral rock wool has a density of 96 Kg/m3 .The under section is formed from 18 SWG CRCA performed sheet after covering with resistance tissues to prevent fire migration or by means of acoustic lined ducts.
(G) FUEL TANK :- One No of sheet metal steel tank of suitable capacity of hold diesel sufficient for 12 hours running at full load, mounted on angle iron frame including the following:- (i) Level indicator to indicate level of diesel in tank. (ii) Drain plug with 2.0 mtrs pipe for draain oil. (iii) fuel strainer. (iv) Pipe for fuel. (v) Air vent. (vi) Mannually operated one no. fuel pump.
(H) INSPECTION PORT :- Aluminium box frame with double welded glass fix type sealed with neoprene rubber gasket, for viewing instrument panel.
(J) VENTILATION :- Forced with suitable fan. (a) supply fan 700mm dia axial flow fan driven by 2 HP 1440 RPM with starter make : KEC/ GEC/ABB. (b) Exhaust Fan 600mm dia axial flow fan driven by 1.5 HP motor 1440 RPM with starter make : KEC/GEC/ABB.
(K) WIRING AND LIGHTING :-PVC copper wire concealed in flexible conduit provided with florescent tube light and MCB. (a) Earthing panel (Neutral body). (b) Control Panel . © Cable leads for batteries. (d) Power cable to euipment. (e) Self Starter
NOTE :- (a) Generating set will be placed on suitable foundation as recommended by manufacturer .and cost thereof shall be included on the prices quoted . (b)Tools shall be supplied as per manufacturer,s instructions and cost thereof shall be included in the price quoted .
Total amount of SCHEDULE 'A' PART-XIX (DEMOLITION / DISMANTLING) (For details see Schedule 'A' Part-XIX in PDF folder)
Bahl Builders Pvt Ltd
RAMJI DAS DHAL CONSTRUCTION PVT LTD
DES RAJ AND SONS BUILDERS PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid