Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.2 L+₹1.2 L (14.9%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹8.3 L
EMD Value
₹20,724
Closing Date
9 Apr 2025, 6:00 pmClosed
AEE PWD ELE SUB DVN TVM
PWD ELE SUB DVN TVM
DEPOSIT- Implementation of Plan Scheme Development of Medical College under DME-SITC of 10 KVA UPS in the Principal Office First floor and 5KVA UPS in the Account Section Ground Floor at Govt MCH Tvpm-General Electrical Work
2025_PWD_758341_1
ESDT/ET_3/2025-26
Open Tender
Electrical Works
Item Wise
60 days
PWD ELE SUB DN TVPM
please refer tender documents
6 documents required · 6 mandatory
₹1,830
₹20,724
9 Jun 2025
4 Apr 2025
11 Apr 2025
4 Apr 2025
9 Apr 2025
4 Apr 2025
Amount
SITC of UPS and electrification
OD235161/2024-2025:Supply installation testing and commissioning of 10KVA UPS with 65AH 20 nos SMF battery 60minite backup a) 3 ph to 3 ph b) Input pf : 0.99 @ full load c) Output pf : 1 d) Input voltage range : 305V -485V with cut off e) THD : ≤ 3% f) Overall Efficiency : ≥94% g) Ambient Temperature : 0-40°C h) Generator Compatibility) Pure sine wave j) Battery over charge & under charge cut off. k) 3 year warranty. l) Bypass arrangement. m) Indications : Digital indications of Input V & A, output V & A, Battery charge, Temperature m) EN/IEC 620401 for General Safety compatibility n) EN/IEC 620402 for Electromagnetic Compatibility. o) EN/IEC 620403 for Performance p) EN/IEC 620404 for Environmental Compatibility q) battery : Exide / Panasonic or equivalent
OD234892/2024-2025: Supply installation testing and commissioning of 5KVA UPS wth 42AH 20nos SMF battery etc are following a) 1 ph to 1 ph b) Input pf : 0.99 @ full load c) Output pf : unity d) Input voltage range : 140V -280V with cut off e) THD : ≤ 10% f) Overall Efficiency : ≥87% g) Ambient Temperature : 0-40°C h) Generator Compatibility. i) Pure sine wave. j) Battery over charge & under charge cut off. k) 3 year warranty. l) Bypass arrangement. m) EN/IEC 620401 for General Safety compatibility n) EN/IEC 620402 for Electromagnetic Compatibility. o) EN/IEC 620403 for Performance p) EN/IEC 620404 for Environmental Compatibility q) battery : exide / panasonic or equivalent
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
OD234570/2024-2025:Supply and installation of C R C A sheet steel, minimum thickness 1mm phosphatised and powder coated, dust and vermin proof 4P enclosure on surface /recess for independent mounting of MCB/RCCB/ISOLATOR .
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD235180/2024-2025:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40 amps 2 pole Isolator complete with connections, testing and commissioning etc. as required.
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
OD234569/2024-2025:Supplying and clamping 20 mm sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required
90.6.4.56:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 6 Run
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
SATHEESH KUMAR S (BID ID -2190886)
Bidder Name
SYNERGY POWER TECH
SATHEESH KUMAR S
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1232319.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .