Loading…
Loading…
Tender Value
₹2.8 Cr
EMD Value
₹2.9 L
Closing Date
26 Mar 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of "V/N" or "V" whichever is less where V= advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited , the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure -VI B, along with copies of Audited Balance sheet duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited balance sheet.
For electrical works, the contractor should have a valid electrical contractor license from the concerned statutory authority of any state of India. The electrical license should be in the name of the firm's or in the name of any authorized person of the tenderers firm. It must be ensured that the validity of electrical license should be valid during the entire contract period duly renewing at appropriate time for extending validity. If the tenderer hired the electrical license, authorization of the same should be submitted. 2) In case of other than Company/ Proprietary firm, Annexure - V(A) shall also be submitted by each member of a Partnership Firm/ Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. as the case may be. Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self-attested /digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document.
13 conditions · 1 needing a document upload
All the tenderers/Contractors have to deposit full bid security as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards . All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded failing which offer will be summarily rejected.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract, with all correction slips up-to- date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions of contract , General Instructions and conditions , explanatory notes of schedule of work and Annexures.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
Manual submission of bid security cannot be entertained/Considered and hence no need of uploading the scanned copy of financial instruments
Whether GST registration available or not?
The contractor has to submit the EPF Code as per the EPFO Act and also has to submit a statement in this regard before signing the contract agreement.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The bidder has to fill in his quoted rate against each item in the Bid rate / Unit rate column. The bidding rate is Rs./ unit, the bidder has to quote his rate for the individual item only
Subsequent to the enforcement of GST Act, the modifications to Para-(a),clause 6, part I of Indian Railways Standard General condition of contract, July 2014 vide Railway Board letter No: 2017/CE/CT/4/GST(a) of 23/6/2017 is as detailed below: Clause No.6 - Care in submission of Tenders: (a)(i) Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer. (ii) Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017 (CGST)/ Integrated Goods and Services Tax Act, 2017 (IGST)/Union Territory Goods and Services Tax Act, 2017 (UTGST)/respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates. iii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to Railway immediately after the award of contract, without which no payment shall be release to the contractor. The contractor shall be responsible for deposition of applicable to the concerned authority. iv) In case the successful tenderer not able to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority. The contractor is liable to pay the taxes as stipulated in the GST Act and Rules and also should furnish the details of GST to deduct from the contractor's bill.
Trivandrum Division: Creation of basic carriage & wagon maintenance at Irumpanam
V-EG-OT-34-2025-2026
V-EG-OT-34-2025-2026
Open
Works - General
270 Days
Thiruvananthapuram, Kerala
₹0
₹2.9 L
26 Mar 2026
2 Mar 2026
12 Mar 2026
89 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,63,73,061 | ||
| — | 1500.00 | — | — | ||
| Transportation & clamping of single run of LTUG cable of size 4 core 35 sq.mm on the building wall /roof structure with suitable size GI fixing hardware and stainless steel nuts/bolts (Cable will be supplied free departmentally at TVC. The vehicle for transportation shall be arranged by Rly.) The loading/unloading is under the scope of contractor | — | — | — | 99,000 | |
| — | 1.00 | — | — | ||
| Fabrication, supply, erection, testing and commissioning of powder coated indoor type cubicle panel made up of 14 SWG sheet and fitted with 4 Nos. 600A capacity copper bus bars 1 No. 400A 36kA 4 pole MCCB as incomer, 2 Nos. 250A 25kA 4 pole MCCBs, 4 Nos. 125A 25kA 4 pole MCCBs and 3 Nos. 63A 25kA 4 pole MCCBs as outgoing with individual chamber for bus-bars and each MCCB including interconnections by adequate size copper complete with multifunction meter, CTs, PT, indication lamps etc. and connection of UG cable. The MCCBs shall be IS/IEC certified | — | — | — | 2,70,878 | |
| — | 1.00 | — | — | ||
| Fabrication, supply, erection, testing and commissioning of outdoor, double door, plinth mounted panel having suitable canopy for protection of the outdoor panel from rain water all made of 10 SWG MS sheet and fitted with 4 Nos. 400A capacity copper Bus bars, 1 No. 250A 25kA 4 pole MCCB as incomer, 7 Nos. 125A 25kA 4 pole MCCBs, 2 Nos. 100A 25kA 4 pole MCCBs and 2 Nos. 63A 25kA 4 pole MCCBs as outgoing including construction of suitable PCC plinth for mounting the panel in the yard & interconnections by adequate size insulated copper wire and connection of UG cables. The MCCBs shall be IS/IEC certified | — | — | — | 2,59,774 | |
| — | 42.00 | — | — | ||
| Supply & erection of OHE portal structure confirming to relevant RDSO Drawing/ Specification for making lighting gantry. Materials for the portal structure are to be procured from RDSO approved suppliers. A sketch showing the details of gantry such as clear span, height from rail level, spacing of proposed lighting gantries between tracks based on the site conditions at Irumpanam (IPN) yard etc. are to be submitted by the contractor for approval of competent authority before ordering the materials for procurement. | — | — | — | 68,72,838 | |
| — | 163.00 | — | — | ||
| Foundation for OHE portal structure in ordinary soil as per relevant RDSO/RE drawing. | — | — | — | 18,33,587 | |
| — | 6000.00 | — | — | ||
| Fabrication, painting, supply and stacking of Steel ladders for lighting gantry portal uprights as per Drawing No. E/CN/ERS/SK/2021/03/R1 | — | — | — | 9,60,000 | |
| — | 6000.00 | — | — | ||
| Leading to site and erection of steel ladders | — | — | — | 1,50,000 | |
| — | 864.00 | — | — | ||
| Fabrication, transportation, supply and stacking of brackets for fixing handrail support consisting of 750mm long 75 x 40x 5mm channel, 750mm long 50x 6mm angle and 40mm dia 1.5 m long B class GI pipe with "T" at top. The brackets shall be fixed at the top of OHE portal boom as detailed in Drg. No. E/CN/ERS/SK/2021/4 | — | — | — | 21,60,000 | |
| — | 864.00 | — | — | ||
| Supply of 16mm dia Hot dip galvanised 120mm long (2 Nos) and 170mm long (2 Nos.) J bolts and other fixtures as detailed in the drawing No. E/CN/ERS/SK/2021/4 and fixing of brackets above the lighting gantry portals | — | — | — | 8,64,000 | |
| — | 1300.00 | — | — | ||
| Supply and fixing of 25mm B class GI pipe as hand rail in already erected brackets at the top of the OHE portal boom and in ladders. The fixing of pipes in ladders shall be by welding | — | — | — | 4,55,000 | |
| — | 3500.00 | — | — | ||
| Supply & fixing of 3mm thick Aluminum chequered sheet on the top of OHE portal boom using suitable GI nuts and bolts | — | — | — | 8,92,500 | |
| — | 3605.00 | — | — | ||
| Excavation of cable trench 0.3 m wide x 1.0 m deep in ordinary soil, back filling of the excavated cable trench (after laying cable), ramming & consolidation properly | — | — | — | 17,08,770 | |
| — | 8.00 | — | — | ||
| Excavation of cable trench 0.3 m wide x 0.1 m deep in tarred/concreted surface, back filling of the excavated cable trench (after laying cable), ramming & consolidation properly | — | — | — | 15,672 | |
| — | 8.00 | — | — | ||
| Concreting the top portion of the cable trench excavated in tarred/concreted surface to a depth of 10.0 cm, using 1:3:6 mix with M sand | — | — | — | 22,104 | |
| — | 437.00 | — | — | ||
| Excavation of cable trench 0.3m wide x 1.0 m deep under/side of railway tracks, duly removing stone ballast, back filling of the excavated cable trench (After laying of cable with HDPE pipe), ramming & consolidation properly and providing back the removed stone ballasts (The work should be carried out very carefully since space constraints and care should be exercised to protect signal cables) | — | — | — | 5,32,266 | |
| — | 1500.00 | — | — | ||
| Supply, transportation loading/unloading and stacking double walled corrugated HDPE Pipe confirming to IS 16025 Part-24 having minimum inner dia of 32mm | — | — | — | 60,000 | |
| — | 1500.00 | — | — | ||
| Leading to site and laying of 32mm dia DWC HDPE pipe in the excavated cable trench | — | — | — | 15,000 | |
| — | 9000.00 | — | — | ||
| Supply and laying of HDPE Pipe 50 mm dia, pressure rating up to 4 PN (Material grade PE 63) as per IS 4984/1995 in the excavated cable trench and threading of 4 core 35 sqmm LTUG cable through the pipe (Cable will be supplied free departmentally at TVC. Transportation shall be arranged by Rly. Loading/unloading shall be under contractor's scope) | — | — | — | 14,04,000 | |
| — | 2400.00 | — | — | ||
| Supply and laying of HDPE Pipe 110mm dia, pressure rating up to 4 PN (Material grade PE 63) as per IS 4984/1995 in the excavated cable trench/duct etc. and threading of LTUG cable of size 4 core 185 sqmm and termination at either ends duly crimped & provided with aluminum sockets (Cable will be supplied free departmentally at TVC. Transportation shall be arranged by Rly. Loading/unloading shall be under contractor's scope) | — | — | — | 11,80,800 | |
| — | 84.00 | — | — | ||
| Supply of weather proof IP 66 protected polycarbonate cable junction box of minimum size 225x295x122 mm similar to Hensel model No. KF 3500H or similar complete with 3 Nos. of 16A porcelain fuse units fixed on 3mm thick hylum sheet including cable termination | — | — | — | 4,20,000 | |
| — | 84.00 | — | — | ||
| Fabrication and supply of suitable GI brackets and fixing of the above weather proof polycarbonate box in the portal uprights including all accessories | — | — | — | 42,000 | |
| — | 568.00 | — | — | ||
| Supply of weather proof IP 66 protected polycarbonate cable junction box for outdoor cable termination with terminals and 6A fuse unit of minimum size 100x100x70 mm similar to Hensel model No. KF 0400G with suitable cable glands/grommets for termination of cables up to 4 sqmm and fixing the same in GI brackets | — | — | — | 3,69,200 | |
| — | 568.00 | — | — | ||
| Fabrication and supply of suitable GI brackets and fixing of above weather proof polycarbonate box having minimum size of 100x100x70mm with all accessories and fixing the same on portal uprights/gantry boom/masonry plinth/cut rail post | — | — | — | 1,13,600 | |
| — | 1.00 | — | — | ||
| Supply & fixing of 2 Nos. 32A ON delay timer, 2 Nos. OFF delay clock type timer, 4 Nos. 32A 3 pole contactors and SP MCBs for bypassing each timer all in a 14SWG MS sheet enclosure including cable connections for operation of 30% and 70% yard lights | — | — | — | 12,319 | |
| — | 10.00 | — | — | ||
| Supply, transportaion & stacking of 433V/43V 3 Phase 3KVA Aux. transformer with 3 phase 440V input in primary side and three numbers of 24V AC supply on secondary side each phase is having 1KVA capacity, all enclosed in 10SWG CRCA sheet steel double door enclosure with canopy for protection from rain water & having provision for cable termination cabinet equpped with four numbers of copper bus bars on incoming side for termination of UG cable and separate cabinet for outgoing side equipped with switching & fuse protection for each phase with supporting steel frame work and LED power supply indication for both incoming and outgoing side for providing supply to the 24V AC LED fittings for bogie examination lights as per the explantory notes to this schedule | — | — | — | 5,00,000 | |
| — | 10.00 | — | — | ||
| Supply of supporting box type angle frame work fabricated with 50X50X6mm MS angle frame work (approximately 75cm height) with suitable canopy for protection of the transformer box from rain water and having painting with two coats each of zinc rich primer and aluminum paint and erection, testing & commissioning for the LV transformer with the angle frame work in the catwalk pillars or already constructed masonry plinth or cut rail post with necessary clamps/cantilever support | — | — | — | 70,000 | |
| — | 43.00 | — | — | ||
| Construction of masonry plinth of suitable height above ground level using 1:3:6 concrete mix with M sand (height appx. 0.6 Metre above ground level based on site conditions) suitable for fixing LV auxiliary transformer/24V LED fittings for underframe examination as per the requirements at site | — | — | — | 1,18,809 | |
| — | 184.00 | — | — | ||
| Fixing of 200W flame proof IP65 protected LED type flood light fitting including supply connection (fitting will be supplied departmentally) | — | — | — | 1,84,000 | |
| — | 72.00 | — | — | ||
| Fixing of 120W flame proof IP65 protected LED type flood light fittings including supply connection (fitting will be supplied departmentally) | — | — | — | 72,000 | |
| — | 500.00 | — | — | ||
| Fixing of 24V AC, 30W flame proof IP66 protected LED fittings including supply connection(fitting will be supplied departmentally) | — | — | — | 4,25,000 | |
| — | 7000.00 | — | — | ||
| Supply and fixing/laying of 25mm dia CPVC pipes in portal uprights/gantry boom/catwalk structure/catwalk pillars | — | — | — | 9,10,000 | |
| — | 3000.00 | — | — | ||
| Supply & drawing/threading of PVC insulated copper cable of size 4.0 sq.mm six runs through the CPVC pipe fixed in catwalk structure/catwalk pillars/cut rail post/DWC HDPE pipe laid in the cable trench including termination in a standard manner as required at site | — | — | — | 11,16,000 | |
| — | 4000.00 | — | — | ||
| Supply & drawing/wiring including termination of 4 runs of 2.5 sq.mm PVC insulated single core multi stranded copper wire through CPVC pipe fixed along portal uprights/gantry boom/catwalk pillars/catwalk structure including termination in a standard manner as required at site | — | — | — | 19,20,000 | |
| — | 30.00 | — | — | ||
| Provision of earthing arrangements as per Drg No. V/E.G/362 and connecting with earthing terminals by means of 2 runs of 6 SWG G.I wire | — | — | — | 1,70,490 | |
| — | 516.00 | — | — | ||
| Supply and fixing of cable glands suitable for 4 core 35 sq mm cable and termination using aluminum socket duly crimped | — | — | — | 1,49,124 | |
| — | 10.00 | — | — | ||
| Supply and fixing of cable glands suitable for LTUG cable of size 4 core x 185 sqmm and termination using aluminum socket duly crimped | — | — | — | 5,130 | |
| — | 4.00 | — | — | ||
| — | — | — | 2,31,220 | ||
| — | — | — | 4,060 | ||
| — | 5.00 | — | — | ||
| — | — | — | 1,52,160 | ||
| — | 10.00 | — | — | ||
| Supply & fixing of 50 Watts flame proof LED flood light luminaire having 72 months warranty inside the above metal box using suitable clamps and angles and supply connection by two core/single core PVC insulated copper wire through PVC flexible pipe Note: 75% payment only will be released after erection. Balance 25% will be released @ 5% per annum till the completion of 5 years warranty period | — | — | — | 75,000 | |
| — | — | — | 14,19,650 | ||
| — | 130.00 | — | — | ||
| Supply and fixing of cable glands suitable for LTUG cable of size 4 core x 120 sqmm and termination using aluminum socket duly crimped | — | — | — | 52,520 | |
| — | 4.00 | — | — | ||
| Transportation, cutting, erection and painting of cut rail post 2.5m long (2m above grounds level after erection), black painting of the coping etc. (Rail post will be supplied departmentally) | — | — | — | 19,200 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS2ofGCC
ATTACHMENT
Correctionslip3.pdf
ATTACHMENT
CorrectionslipNo5.pdf
ATTACHMENT
CorrectionslipNo6ofGCC2022.pdf
ATTACHMENT
ACS7ofGCC
ATTACHMENT
GCCCorrectionslip8.pdf
ATTACHMENT
GCCCorrectionslip9.pdf
ATTACHMENT
Annex.VIB.pdf
ATTACHMENT
Earthing.pdf
ATTACHMENT
RollinginexaminationVE.31.21-22.pdf
ATTACHMENT
Explanatorynote.pdf
ATTACHMENT
steelladder.pdf
ATTACHMENT
lightingportal.pdf
ATTACHMENT
portableweldingmachinetappingpoint.pdf Portable welding tapping point
ATTACHMENT
Annex.VA.pdf
ATTACHMENT
AnnesureIII.pdf
ATTACHMENT
ACS-10.pdf
ATTACHMENT
ACS2023.pdf
ATTACHMENT
GCCApril-2022withACS_1.pdf
ATTACHMENT
portableweldingmachinetappingpoint.pdf
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.2022.pdf
ATTACHMENT
CorectionslipNo7-2022-CE-I-CT-GCC-2022-POLICY-Pt.Idated25.09.2024.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .