| 1 | L1₹2.3 CrAccepted-AOC OLD AIRFIELD ROAD RAWALPORA WANBAL SRINAGAR 190005 J K | SRINAGAR | SRINAGAR | J K | 190005 | ₹2.3 Cr Quoted ₹2.4 Cr | L1 | Accepted-AOC Being Lowest L1 |
| 2 | L2₹2.4 Cr+₹7.2 L (3.05%)Rejected-AOC | ₹2.4 Cr+₹7.2 L (3.05%) | L2 | Rejected-AOC Other than Lowest that is L2 |
| 3 | L3₹2.6 Cr+₹22.9 L (9.66%)Rejected-AOC BANPUR BATWARA SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | ₹2.6 Cr+₹22.9 L (9.66%) | L3 | Rejected-AOC Other than Lowest that is L3 |
Tender Value
Refer Docs
EMD Value
₹3.0 L
Closing Date
20 May 2022, 6:00 pmClosed
Chief Engineer 31 Zone
HQ Chief Engineer 31 Zone, Pin- 914631 C/o 56 APO
PROVN OF TECH ACCN AT RAMPUR
2022_MES_505601_2
PROVN OF TECH AREA AT RAMPUR
Open Tender
Civil Works
Lump-sum
900 days
Rampur
As per NIT
12 documents required · 12 mandatory
₹2,000
Yes
GE 969 EWS
₹3.0 L
Yes
21 Jun 2022
19 Apr 2022
23 May 2022
19 Apr 2022
20 May 2022
3 May 2022
19 Apr 2022 - 30 Apr 2022
Amount
Note: (i) Please refer Schedule 'A' Notes given on serial page No. 22 to 29 of tender documents. (ii) Item from Srl No. 3 to 5 of this document shall be Part-VIII (Miscellaneous Items of Works) of BOQ (iii) Unless otherwise specified, earth work and excavation shall be measured and paid separately for Sch 'A' Part II to VI and VIII (iv) This schedule 'A' Part-VIII (Miscellaneous items of Works) is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 30
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 32
Lump sum price worked out by the contractor for ROAD, PATH AND CULVERT WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 35
Lump sum price worked out by the contractor for AREA DRAINAGE listed in Schedule 'A' Part-IV brought forward from serial page No. 36
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 39
Lump sum price worked out by the contractor for SITE CLEARANCE & EARTH WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 40
Lump sum price worked out by the contractor for DEMOLITION AND DISMANTLING WORKS as listed in Schedule 'A' Part-VII brought forward from serial page No. 41
INTERNAL ELECTRIFICATION WORKS
Supply and fixing LED tube light fittings 1 x 18W, 220V, AC Box type with driver/holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose with and including hanging chain or hook fitted on two round blocks/fixing arrangements on struss/roof/wall complete all as directed.
Supply and fixing MCB SPN, 6-32 Amp, 240volt, 50Hz, AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' curve, 10KA bearing capacity and terminal box suitable upto 16Sqmm cable, confirming to IS/IEC 60898-1 & IS/IEC 60947-2 complete all as directed.
Supply and fixing MCB SPN, 63 Amp, 240volt, 50Hz, AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' curve, 10KA bearing capacity and terminal box suitable upto 35Sqmm cable, confirming to IS/IEC 60898-1 & IS/IEC 60947-2 complete all as directed.
Supply and fixing MCB SP, 6-32 Amp, 240volt, 50Hz, AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' curve, 10KA bearing capacity and terminal box suitable upto 16Sqmm cable, confirming to IS/IEC 60898-1 & IS/IEC 60947-2 complete all as directed.
Supply and fixing MCB SP, 63 Amp, 240volt, 50Hz, AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' curve, 10KA bearing capacity and terminal box suitable upto 16Sqmm cable, confirming to IS/IEC 60898-1 & IS/IEC 60947-2 complete all as directed.
Supply and fixing MCB TPN, 32 Amp, 415volt, 50Hz, AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' curve, 10KA bearing capacity and terminal box suitable upto 25Sqmm cable, confirming to IS/IEC 60898-1 & IS/IEC 60947-2 complete all as directed.
Supply and fixing MCB TPN, 63 Amp, 415volt, 50Hz, AC, made from moulded self-extinguishing thermostat plastic and suitable for 'C' curve, 10KA bearing capacity and terminal box suitable upto 25Sqmm cable, confirming to IS/IEC 60898-1 & IS/IEC 60947-2 complete all as directed.
Supply and fixing LED street light fitting, 25 watt, 230 volt, AC outdoor type with high pressure die cast aluminium housing and heat resistance complete with driver, lamp, bracket/clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connection wire of 1.50mm sqmm 3 core from ceiling rose to light fitting complete all as directed.
Supply and fixing LED luminaire 600 x 600mm, 36 watt, 220Volt, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connection up with driver with three core flexible copper conductor cable of suitable size complete all as directed.
Supply and fixing high bay LED light, 150 watt, 230 volt, AC, outdoor type with high pressure, die cast, aluminium housing and heat resistance complete with driver, made suitable arrangement to fix light from roof/truss with GI bracket/clamp and nuts & bolts with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connection up with driver with three core flexible copper conductor cable of suitable size complete all as directed. MAKE : Havells CAT Part No. GAZELLAHBP 150WLED857PBOTG or equivalent to Phillips/CG
Supply and fixing ceiling fan, 1200mm sweep, energy saving, 5 star, metal body including connection wire of 1.5sqmm 3 core from ceiling rose to fan in flexible conduit complete with hanging arrangement by GI hook fitted to ceiling truss by means of nuts, bolts and washers complete all as directed.
Supply and fixing wall mounted air circulator 600mm sweep, heavy duty, including connection wire of 1.5sqmm 3 core from ceiling rose to fan in flexible conduit complete all as directed. MAKE : Havells Model No. : TURBO or equivalent in CG/Bajaj
'Supply and fixing sub main wiring with two runs of single core FRLS PVC insulated multi-stranded copper conductor 4 Sqmm and one run of 4 Sqmm for earth continuous earth wire including 20mm dia PVC conduit medium grade ISI marked with all accessories complete all as specified and directed. Note : Three runs of PVC cable 4 sqmm & one runs of PVC Conduit will be considered as one unit.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x6 mm thick buried directly in gound (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron earth lead 4mm dia by means of bolt, nuts check nuts and washers of galvanised iron and 4 mm dia GI earth wire protected by provn of GI light grade pipe 15mm bore upto 7.5mtr including provision of concrete pit in PCC (1:2:4) type B-1 ( using 20 mm graded crushed stone aggregates ) with 40mm thick cover of RCC (1:2:4) reinforced with XPM (Weight not less than 4kg/Sqm) and frame of angle iron 25x 25x3mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and excavation/earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No 3 of SSR -2009 Part -I and connecting to earth test point all as specified or indicated including testing on completion, complete all as specified and directed. Note : The quoted rate of earthing shall be deemed to include cost of 7.5 m long galvanised wire 4 mm dia and GI light grade protection pipe 15 mm bore and GI medium grade 20 mm bore watering pipe. Any variation in length shall be adjusted through deviation order.
EXTERNAL ELECTRIC SUPPLY WORKS
M & L for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Note: (i) Measurement shall be taken only after punning down sand cushioning.
Supplying, transporting to site, erecting and fixing in poistion steel tubular swaged poles complete with MS base plate of size 300 x 300 x 6mm continuously welded to pole, finial taper plug, bolts, nuts & screws as specified type 410 SP- 55 (11 metres long) including two coats of black bituminous paint internally throughout and externally upto embedded portion and including applying two coats of synthetic enamel aluminium paint over a coat of red oxide primer with black and white strip of 30 cm each upto 1.5 m height and two coats of aluminium paint over a coat of red oxide primer externally on remaining exposed surface after errection in position including preparation of surface, complete all as specified and directed. Note:- Necessary earth work , PCC coping will be measured and paid for separately.
M&L Earthling complete with galvinised steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level , connecting to galvanised iron earth strip 32x6 mm, by means of bolt nuts , check nuts and washer of galvanised iron and GI strip protection by light grade GI pipe 40 mm dia upto 7.5 mtr including provn of concrete pit in PCC (1:3:6) type C-1 using 20 mm graded stone aggregates, with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 , funnel with wire gauge (0.68mm) 8 mesh per liner inch ,80 mm thick RCC pit cover 320mmx320mm of concree (1:2:4) type B-1 using 20 mm aggregate reinforced with XPM jalli and charcoal dust and common salt all as in shown in electrical plate No-03 of MES SSR Pt-I and specified including provision of earth lead strip protected by 40 mm dia light grade GI Pipe and watering pipe shall be 20 mm dia medium grade and including all excavation and earth work and connecting the earthing to and earthing test point/ Transformer neutral / body / LT panel etc. and testing on completion , complete all as specified and directed Note: The unit quoted rate of earthing shall be deemed to included cost of 7.5 M long GI earth strip 32x6 mm and protection pipe of 40 mm bore light grade, GI 20mm dia medium grade watering pipe. Any variation in length shall be adjusted through deviation order.
Material and labour for sub class 'B' bricks laid dry and perpendicular to the axis of the cable in trenches as cable protection complete all as specified and directed.
Supply and fixing 32 Amp, TP (3P + E) sheet metal earth plug and socket DBs for 3 phase power supply complete all as specifeid and directed.
Supply, installation, testing and commissioning of copper wound transformer, step down, 160 KVA, outdoor type, complete with standard fittings, HT, 11 KV, 3 phase, LT 433 volts, 3 phase 4 wire with core type copper wound oil immersed, naturally cooled, ON AN with external cooling tubes/fins, delta connected on primary side (HV) and star connected on secondary side (LV) having tapping at 0 ±2.5% and ±5% and ±7.5% on HV side to be changed by means of hand operated off load tap changer /gear switch handle shall be provided with the locking arrangement alongwith top position indicator : -
(a) HT insulator with brass bushing at primary side (b) One cable box on LVB side consisting of four numbers procelain bushing with rods complete with nuts and washers with two numbers cable glands suitable for reception/taking out of XLPE insulated heavy duty armoured cable including glands, joint and jointing material complete. (c ) Oil conservator with filter type drain valve and oil level gauge (d) De-hydrating breather with first fill of silica gel (e) Explosive vent (f) Thermometer pocket on tank cover (g) One number 100mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celcious (h) Two earthing terminal on tank cover to facilitate fixing of 32x6mm GI earth strip for earthing (j) Rating plates and terminal making plates (k) Oil level gauge (l) Oil drain filter valve (m) Lifting lugs (n) Oil filling hole with cap/plug (o) Four plain solid cast steel detachable rollers (p) Extra bushing for neutral outside LT Box (q) First filling of new tranformer oil IS-335/93 (fourth revesion) marked filtered and tested upto 50KV die electric strength at 2.5mm air gap between testing electrodes. All as per IS-1180 (Part-I) 2014 with maximum total loses as per energy efficiency level-2.
Material and labour for installation, commissioning & testing of LT panel board (Main Panel) outdoor type fabricated out of 3.15mm thick CRCA sheet, dust proof, totally enclosed metal clad, double door type accessible from front and rear side both with locking arrangement, 3 phase 1.5sqmm single core copper wire system at AC 440Volt, 50Hz, with colour coated aluminium bus bar of rated current capacity 400 Amp complete applied with two coats of anti corrosion primer and mounted on angle iron of size 50x50x6mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories: -
EOT CRANE WORKS
Designing, Supply, installation, testing, Trials and commissioning of EOT Crane indoor type 2 Ton Capacity with minimum 16 Metre span (Centre to centre spacing of RCC brackets) , lifting height 6metre, alongwith double cross girder for short travel, steel girder for long travel ,power supply system for crane with web angles with the following specifications complete all as specified and directed: -
GENERAL SPECIFICATIONS: - (a) Type of Crane : Double Girder (b) Span : 16 metre (c ) Lifting Height : 6 metre (d) Speed (MH) : 3 (MPM) (e ) Speed (CT) : 16 (MPM) (f) MH motor type : Squirel cage (g) MH motor pole : 4 pole (h) MH motor insulation class - F class (j) CT motor type - Squirrel cage (k) CT motor pole - 4 pole (l) Control : Pendant controlled (m) Class of Duty : M 2 S 2 E 2 (n) Power supply : 415/110V
(o) Speed (LT) (mpm) : 2-20 through VVVF Drive (p) MH motor KW : 1.50 (q) MH motor no. of starts/Hrs : 150 (r) MH motro qty : 01 (s) CT motor KW : 0.25 (t) CT motor no. of starts/Hrs : 150 (u) CT motor CDF : 40% (v) CT motor qty : 01 (w) CT motor insulation class : F (x) CT motor Duty : S4 (Crane only) (y) LT motor type - Squirrel cage
(aa) LT motor KW : 0.55 (ab) LT motor pole : 04 pole (ac ) LT motor no. of starts/Hrs : 150 (ad) LT motor CDF : 40% (ae ) LT motor qty : 02 (af) LT motor insulation class : F (ag) LT motor Duty : S4 (Crane only) (ah) Brake type (MH) : AC EHT (aj) 2nd Brake type (MH) : AC EHT (ak) Wire rope dia (MH) : 8mm (al) Construction/strength : 6x36/1770 N/MM² - Ungalvanised (am) Type (Steel/fibre core) : Steel (an) Factor of safety of wire rope : minimum 6 (ao) Number of Falls (MH) : 04
(ap) Limit Switches (MH) : Rotary/Gravity (aq) Limit Switches (CT) : Two way lever type (ar) Limit Switches (LT) : Two way lever type (as) Gear box type : Helical hardened Gear Box with input Profile Ground (at) Material of Gears and Pinion : Low Carbon Alloy Steel (au) Hardness of Gears and Pinion : 55-60 HRC (av) Rope Drum Type : Seamless Pipe (aw) Rope Drum Material : ASTMA 1106 Gr A/B (ax) Wheels Type : Double Flanged (ay) Material of Wheels : En8/En9/CssMn75
(aaa) Hardness of wheels : 300-350 BHN (aab) CT Rail Size : 40 x 40mm sq bar (aac ) CT Wheel Dia (mm) : 160 (aad) CT Wheel Qty : 04 (aae ) LT Wheel Dia (mm) : 160 (aaf) LT Wheel Qty : 04 (aag) CT wheel load (T) : 0.79 (aah) LT Wheel load (T) : 3.78 (aaj) LT Rail width (mm) : 63 (aak) LT Rail length : 2 x 40 = 80 metre (aal) Crane weight (Ton) (Approx ) : 10.28 (aam) LT DSL Type : Shrouded Bus Bar GI (aan) LT Wheel Base (mm) (Approx) : 2700
(aao) Bay Length (M) : 40metre (aap) Incoming isolator provided at floor level (aaq) Emergency switch on corners of Girder : on all 04 corners (aar) MH Hook Type : C shank type confirming to IS 15550 (aas) Safety latch : Provided (aat) Couplings : Geared type (aau) Bridge Girder : Box Section (aav) Control Panle : IP 54 rated (aaw) Painting : Epoxy based paints (aax) Cables : Copper conductor EPR (rubber) (aay) Maintenance Cabin : Provided. Notes:- (i) The contractor wil submit Technical data and design drawing before starting the work for approval from the Accepting Officer. (ii) The rates quoted shall demmed to include steel girder for cross run and long run. (iii) Contractor should submit the test report as per IS-3177-1999 after installation from authorised Govt agency.
M/S KASHCON CONSTRUCTION CO
M/S SUHEEL CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .