Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC PARUTHIYEZHATHU HOUSE MULAVUKAD P O NORTH ERNAKULAM 682 504 | ERNAKULAM | KERALA | 682504 | ₹7.7 L Quoted ₹7.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹8.4 L+₹58,940 (7.50%)Rejected-Finance EDALAKADU THABORE P O MOOKANNOOR ERNAKULAM DIST KERALA 683 577 | MOOKANNOOR | ERNAKULAM | KERALA | 683577 | ₹8.4 L+₹58,940 (7.50%) | L2 | Rejected-Finance Other than lowest tenderer |
| 3 | L3₹8.7 L+₹80,626 (10.3%)Rejected-Finance | ₹8.7 L+₹80,626 (10.3%) | L3 | Rejected-Finance Other than lowest tenderer |
| 4 | L4₹9.1 L+₹1.2 L (15.4%)Rejected-Finance 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | ₹9.1 L+₹1.2 L (15.4%) | L4 | Rejected-Finance Other than lowest tenderer |
| 5 | L5₹9.1 L+₹1.3 L (16.1%)Rejected-Finance | ₹9.1 L+₹1.3 L (16.1%) | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹9.3 L
EMD Value
₹18,500
Closing Date
5 Apr 2024, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
SPECIAL REPAIRS FOR IMPROVEMENT OF ELECTRICAL ROOM WITH REPLACEMENT OF SWITCH GEARS, EARTHING ETC. AT SMA RAMESWARAM UNDER GE FORT KOCHI
2024_MES_645281_1
8995/E8_GE_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
FORT KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹18,500
Yes
11 Sept 2024
6 Mar 2024
12 Apr 2024
6 Mar 2024
5 Apr 2024
22 Mar 2024
Amount
Taking down carefully copper/aluminium point wiring (light ,fan,socket or power) complete (fittings such as switches, ceiling roses, pendants regulators sockets etc to be measured separately) removing materials from site taken as credit and making good the disturbed surfaces all as specified and as directed
Taking down ofcarefully by unscrewing from boards /outlet boxes ,fittings and fixtures such as switches , sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc for reuse at site or taken as credit and making good the disturbed surfaces all as specified and as directed
M & L for point wiring in and including rigid non metallic PVC casing and caping ISI marked of suitable dia, with 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw, cup washer & including PVC insulated & unsheathed stranded FRLS copper condutor of 1.5 Sqmm as continuous earth wire complete for one light point controlled by one switch, all as specified as directed.
-Ditto- all as per item No.3 but for one 5 Amps socket outlet point 3 pin on same board alongwith other switches.
M & L for point wiring in and including rigid non metallic non metallic PVC casing and caping , ISI marked of suitable dia, with 4 Sqmm PVC insulated unsheathed FRLS stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw , cup washer & including PVC insulated & unsheathed stranded FRLS copper condutor of 4 Sqmm as continuous earth wire for 15 Amps socket independent complete all as specified as directed.
M & L switch flush type single pole, one way, 5 Amps, all as specified and directed.
M & L switch socket combination 3 pin 5 Amps flush type, all as specified and directed.
M & L switch socket combination 3 pin 15 Amps and 3 pin 5 Amps flush type, all as specified and directed.
M & L ceiling rose three terminals 230 V (ISI marked) surface bakelite comlete all as specified and directed.
Supply and fix of LED Tubelights of 20W(+/- 10% Tolerance) with PVC body linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection, powerfactor>0.95,THD</=10%, rated life of 50,000 hours, system efficacy greater than or equal to 125 lm/w, including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 2 Year Warranty for the fixture shall be provided by the contractor). Note: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc as required at site is deemed to be included in the rate(Sample shall be approved by the engineer in charge).
S&F three pole and neutral enclosure with a three pin and earth plug and socket complete with one triple pole MCB 32 amps capacity and taking down existing u/s item all as specified and as directed.
M&L Sub main wiring with 4 runs of 6 sq mm single core, multistranded PVC insulated unsheathed FRLS cable 1100 volts grade with copper conductor, drawn in and including pvc casing and caping of suitable size, conduit fittings and accessories concealed in wall/roof/floor with one run of 6 sq mm PVC insulated unsheathed FRLS copper conductor cable as earth continuity conductor and connecting to common earth dully all as specified. Note : Four single cable run of 6 sq mm and one run of 6 sq mm earth wire and conduit measured as one unit length).
M&L Sub main wiring with 4 runs of 4 sq mm single core, multistranded PVC insulated unsheathed FRLS cable 1100 volts grade with copper conductor, drawn in and including pvc casing and caping of suitable size, conduit fittings and accessories open in wall/roof/floor with one run of 4 sq mm PVC insulated unsheathed FRLS copper conductor cable as earth continuity conductor and connecting to common earth dully all as specified. Note : Four single cable run of 4 sq mm and one run of 4 sq mm earth wire and conduit measured as one unit length).
M&L Sub main wiring with 2 runs of 6 sq mm single core, multistranded PVC insulated unsheathed FRLS cable 1100 volts grade with copper conductor, drawn in and including pvc casing and caping of suitable size, conduit fittings and accessories open in wall/roof/floor with one run of 6sq mm PVC insulated unsheathed FRLS copper conductor cable as earth continuity conductor and connecting to one run common earth dully all as specified. (Note:Two single cable run,one run earth wire and conduit measured as one unit length).
M&L Sub main wiring with 2 runs of 4 sq mm single core, multistranded PVC insulated unsheathed FRLS cable 1100 volts grade with copper conductor, drawn in and including pvc casing and caping of suitable size, conduit fittings and accessories open in wall/roof/floor with one run of 4 sq mm PVC insulated unsheathed FRLS copper conductor cable as earth continuity conductor and connecting to one run common earth dully all as specified. (Note:Two single cable run, one run earth wire and conduit measured as one unit length).
S&F in repairs SPN distribution board factory made double door flush type all as per IS 8623 made from sheet metal duly powder coated 12 way to be fixed flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge.
S&F in repairs SPN distribution board factory made single door flush type all as per IS 8623 made from sheet metal duly powder coated 4 way to be fixed flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge.
S&F in repairs TPN distribution board factory made single door flush type all as per IS 8623 made from sheet metal duly powder coated 8 way to be fixed flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge.
S&F in repairs TPN distribution board factory made single door flush type all as per IS 8623 made from sheet metal duly powder coated 4 way to be fixed flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB TPN 32 Amp, 415 volts of 10 KA rupturing capacity, c-curve type as out going including taking down of existing unserviceable all as specified.
S&F in repairs MCB SPN 40 Amp, 240 volts of 10 KA rupturing capacity, c-curve type as out going including taking down of existing unserviceable all as specified.
S&Fin repairs MCB SP 32 Amp, 240 volts of 10 KA rupturing capacity, B-curve type including taking down of existing unserviceableall as specified.
S&F Sheet metal enclosure of minimum size 60x25x15 cm suitable for accomodating and including MCCB of 160 Amps 16 KA capacity including taking down existing enclosure complete all as specified and as directed. Note : Rate of the MCCB is deemed to be included in the quoted rate.
Taking down of submain wiring of any size with conduit complete all as specified and as directed
Supply and laying synthetic rubber insulated mats 2 mm thick for voltage upto 3.3 K for electrical purpose as per IS15652-2006 (superseding IS 5424)suitable for electrical shock safety including taking down of existing mat complete all as specified and as directed.
M&L for painting on old inner/outer surfaces LT panel by spray paint after scrubbing painting of indoor panel of size up to 2m x 1.5mx.2m and painting the cleaned surface with synthetic enamel paint of existing colour to achieve good finish by applying two coats of paints by spray painting machine carefully after disconnection of power supply and covering the meters, indicators and switches to prevent from fall of paint drop on them and removing burned old wirings, rewelding of any detached portions from the panel , over all inside cleaning of the panels complete all as specified and as directed. Note: Rate deemed to be inclusive of cleaning floor of machine room for laying of mat and proper layout of hanging cables in the electrical room etc
Supply, fabricating, fixing in repairs the CRCA sheet metal of any thickness for the body/door of the LT Panel of required size & chequred plate including the cutting /removing of the existing unserviceable part , making the appropriate hole for proper cable entry/exit and with proper fasteners required as per site requirement all as specified and directed.
M&L for painting on old surfaces chequred plate/panels by spray paint after cleaning strains and grease/oil spots with sand paper & thinner and painting the cleaned surface with synthetic enamel paint of existing colour to achieve good finish by applying two coats of paints all as specified and as directed
S&F 3P module DIN ,24 hours program, back up of Hrs , current capacity 16 to 20 Amps with suitable contactor and MCB including suitable size metal enclosure and taking down of old timer switch all as specified and as directed
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI strip 32x6mm mm by means of bolts, nuts , check nuts and washers of GI and GI tubing 40 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I including taking down old materials of earthing all as specified and directed by the Engineer in Charge.
Sreema Enterprises
AB CONSTRUCTIONS
St George Engineering Works
Super Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .