1 Providing and erecting XLPE (IS:7098) (1)-88 ISI 680.00 535.00 Mtr
armoured cable multistrand Aluminium conductor
for 1.1 KV. to be laid on wall with necessary clamps
or in existing trench / pipe of following size of cables
(F) 3 1/2 core 120 Sq. mm (70 Sq. mm 1/2 core)
2 Supplying and erecting push button operated fully 2.00 11950.00 Ea.
automatic Star-Delta starter with 3 Nos. of 32A.
rating contactors and 1 No. of directly operated
thermal overload relay having 20-32A range in sheet
steel enclosure for 3 phase 415V. 50 c/s A.C. motors
up to 35 H.P. complete erected on (A) P.W. Block
with necessary connection Cat.III
2A (B) For erection on Angle iron frame add to the 2.00 171.00 Ea.
3 Providing and erecting iron clad cable route marker 56.00 238.00 Ea.
duly marked with ELE. CABLE of size 23 cm. X 12 cm.
Flushed with ground in cement foundation as
directed by Engineer in charge.
4 Solderless crimping type Aluminium lugs conforming 24.00 45.00 Ea.
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut
bolts in an approved manner. (G) 120 Sq.mm.
5 Making trench in soft soil of suitable width of 90 cm 680.00 55.00 Mtr
deep for laying cable or locating the fault all over the
run and back filling the same and making the surface
as normal ground.
6 Providing & laying R.C.C. Hume pipe for cable to be 600.00 293.00 Mtr
laid 90 cm. below ground across the road crossing or
on floor with necessary material in an approved
manner and making the ground as per original. (D)
250 mm dia
7 Providing Approved make Triple Pole Metal Clad 2.00 7933.00 Ea.
Switch Fuse Unit 415/500 V. with HRC fuse of
suitable load and neutral link confirming to IS (a)
8 Supplying KITKAT pattern porcelain cut-out fuse with 6.00 416.00 Ea.
base of following current capacity erected on
existing block board. (vi) 200 A. 500 V.
9 Supplying & erecting earth pit of minimum bore dia. 2.00 4546.00 Ea.
150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I. Pipes
having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having
200-250 Micron galvanising, connection terminal dia
of 12mm with constant ohmic value surrounded by
highly conductive compound with high charge
dissipation suitable for following type of applications
with chamber and heavy duty cover.(A) (approved
make OEM has to submit test certificate including
value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to
ensure the value of earthing resistance mentioned in
test Certificate) & having back filling compound of
(B) Inner chemical (CCM Compound)- Resistivity:
ohm / meter testing as per IEC 62561-2017, Voltage
drop: < 1 volt at no load & dry form, Sulphar content:
<2% (C) Back fill Compound Earthing compound
should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.
(a) For Electrical Installation up to 440V in normal
soilLength of pipe - 1 Mtr Back filling compound -
10 Providing and erecting Mains with ISI marked, 1.5KV 12.00 141.00 Mtr
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated
conforms to IS 694, IEC-227 erected in existing pipe
of following size (Specifically for control panel,
relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and
bolts if required.(g) One wire 16.00 sq. mm
11 Solderless crimping type Copper lugs conforming to 36.00 12.00 Mtr
IS suitable for cable of following size evenly crimped
with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an
approved manner. (C) 16 Sq.mm.
TOTAL RS
I we am/are agree to carried out and complete the above mentioned work at…………………….% (in
words………………………………..………………….Percentage) below/above rates mentioned schedule- B.
Contractor Signature Executive Engineer
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.(NIT).pdf
ADVERTISEMENT.pdf
Electrical Specification.pdf
SBD.pdf
SCHEDULE-B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .