Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC | L1 | Accepted-AOC lowest tender | |
| 2 | L2₹38.9 L+₹2.2 L (5.84%)Rejected-Finance KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹39.5 L+₹2.7 L (7.36%)Rejected-Finance 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹40.8 L+₹4.0 L (10.8%)Rejected-Finance NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L4 | Rejected-Finance Other than lowest tender | |
| 5 | L5₹42.7 L+₹5.9 L (16.0%)Rejected-Finance THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L5 | Rejected-Finance Other than lowest tender |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
17 Jun 2021, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services, Garrison Engineer (Naval Services), Kataribagh, Naval Base Post, Kochi, 682 004.
SPECIAL REPAIRS FOR REPLACEMENT OF BER COOLING APPLIANCES UNDER INS GARUDA AND PROVISION OF AIR CONDITIONER FOR RED FORCE AT MWC (K) AND ASW SCHOOL AT NAVAL BASE KOCHI
2021_MES_447559_1
8807/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
KOCHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹66,000
Yes
22 Jul 2021
1 Jun 2021
19 Jun 2021
1 Jun 2021
17 Jun 2021
4 Jun 2021
2 Jun 2021 - 3 Jun 2021
Amount
Dismantling and taking down window AC of any capacity comprising of all connected accessories from existing locations and deposit to MES Store Yard.
Material & Labour for closing the existing opening (Opening of size not less than 0.6X0.4X0.23 metre) with brick masonry at the removed locations of window ACs, plastering, painting as matching to the existing surfaces complete all as directed by EIC.
Dismantling and taking down split ACs with and including dismantling of three core copper cable, connecting MCB boxes, copper piping etc, complete making good disturbed surfaces as matching to the existing surfaces complete all as specified and directed
Supply, installation, testing and commissioning of split air conditioning unit 2 TR capacity Inverter type complete with cordless remote control, minimum 3 star labeled, five year warranty on ind00r and outdoor PCBs, Ten year warranty on compressor, eco friendly refrigerant gas, 6000 Kcal / Hr, 50 Hz, 240 volts, air cooled copper condenser with all accessories varied speed including fixing the outdoor unit with suitable stand as site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection, including suction and discharge copper pipes with refrigerant including with nitrile rubber insulation and control cable from indoor to outdoor as required at site, Power cabling from Isolator/ Enclosure to unit, first charging of refrigerant gas, drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified.
Supply, installation, testing and commissioning of split air conditioning unit 1.5 TR capacity Inverter type complete with cordless remote control, minimum 3 star labeled, five year warranty on ind00r and outdoor PCBs, Ten year warranty on compressor, eco friendly refrigerant gas, 4500 Kcal / Hr, 50 Hz, 240 volts, air cooled copper condenser with all accessories varied speed including fixing the outdoor unit with suitable stand site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection, including suction and discharge copper pipes with refrigerant including with nitrile rubber insulation and control cable from indoor to outdoor as required at site, Power cabling from Isolator/ Enclosure to unit, first charging of refrigerant gas, drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified
Supply, installation, testing and commissioning of water cooler with inbuilt purifier ozone based technology cooler stainless steel body cold, hot and normal water output most superior water purification technology ozonisation, based on microprocessor , controlled electronic system industrial model with dispenser to ensure the precise operation 90 Lt/ Hr dispensing capacity and steel storage tank and connecting up including taking down the existing old unserviceables cooler from existing location transporting and depositing to MES store yard complete all as specified and directed
Supply and install refrigerators, electric driven single phase, single door, digital inverter compressor of energy efficient capacity 240 liters, 240 volt AC with minimum 3 star rated including testing and commissioning and taking down the existing old unserviceable unit from existing location, transporting and depositing to MES store yard complete all as specified and directed.
Supply, installation, testing and commissioning of deep freezer, electric driven single phase, digital inverter compressor of energy efficient capacity 300 liters, 240 volt AC with minimum 3 star rated including taking down the existing old u/s unit from existing location, transporting and depositing to MES store yard complete all as specified and directed.
Supply and fixing copper refrigerant piping of both sizes for suction line 5/8" and 1/4" for discharge including thermal insulation class ‘O’ nitrile rubber insulation density 45- 55 kg/m³, for suction/ discharge line, beyond standard length provided with original units by the manufacturer. Notes: i) This item shall be measured for the quantity used at site for Serial item No. 4 & 5 for beyond the length provided by OEM. ii) One run of both 5/8" & 1/4" pipes along with insulation shall be measured as one length.
Material & Labour for sub main wiring with 2 runs of 4 Sqmm PVC insulated FRLS multi stranded copper conductor cable including suitable size PVC conduit with one run of 4 Sqmm PVC insulated FRLS cable as earth continuity wire complete all as specified and as directed. Note: Three runs of 4 Sqmm and one run of PVC conduit shall be measured as one length.
Material & Labour for sub main wiring with 2 runs of 2.5 Sqmm PVC insulated FRLS multi stranded copper conductor cable including suitable size PVC conduit with one run of 2.5 Sqmm PVC insulated FRLS cable as earth continuity wire complete all as specified and as directed. Note: Three runs of 2.5 Sqmm and one run of PVC conduit shall be measured as one length.
Supply & Fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amp, 240 volts 10 KA, C curve and plug to with male ended portion complete all as specified and directed.
Supply & Fix MCB SP, 6 to 32 Amp, C curve, 240 Volt, 10 KA complete all as specified and directed.
Supply & Fix Voltage stabilizer suitable for Inverter Split air conditioner for automatic operation single phase naturally air cooled, copper wounded indoor type & designed for input variation between 140V to 280V with output voltage stabilized at 230 with accuracy ± 2.5% and of capacity suitable for 1.5 TR AC complete all as specified and directed.
Supply & Fix Voltage stabilizer suitable for Inverter Split air conditioner for automatic operation single phase naturally air cooled, copper wounded indoor type & designed for input variation between 140V to 280V with output voltage stabilized at 230 with accuracy ± 2.5% and of capacity suitable for 2 TR AC complete all as specified and directed.
Supply, installation, testing and commissioning of Walk - in cold room for Medical Storage of nominal size 15' X 08' X 09' (in feet) consisting of capacity refrigeration 15000 BTU/ Hr with 2 ºC room temperature and 38 ºC ambient temperature with having of refrigeration unit (indoor and outdoor) working at 230 Volt single Phase, 50 HZ, eco friendly refrigerant for the Cold room consisting of Dimensions 15 x 09 x 08 feet (external), inside room Temp +2 to +8 ºC, for storage - medicines, PUF panel Thickness of insulation 60mm thick, Lamination of panels for wall (Pre fabricated) modular PUF panels & ceiling- SS 304 grade inside and outside (lamination thickness 0.5mm), Corner panel- 04 No of corner panel for wall insulation, Floor insulation- 60mm PUF panel with 1.2 mm aluminum chequered plate, Flush type self-closing swing door with SS/ SS lamination 60mm thick 34”x 78” clear opening including with accessories- Anti- condensation door heater, pad lock, position seal closure, human safety release knob, aluminium kick plate on both side, Compressor type- hermetic reciprocating, Evaporator body- Stainless steel (304 grade), with Digital controller Temperature range- (-) 40 ºC to (+) 80 ºC, Thickness of insulation- 60mm with 40Kg/M3 density, Lamination of panels for wall & ceiling- SS 304 grad inside and outside (Lamination thickness 0.5mm),Lock arrangement- CAM lock with metal plunger, including all kind of electrical connecting cables, MCBs, electric DBs ,PCC foundations, addition/alteration of existing room/walls (if required) as per OEM recommendations shall be provided for entire completion, complete all as specified and directed.Make: Bluestar/bitzer/voltas
MS BUILDERS
AR Traders
Glacier Cooling Solutions Private Limited
Green Ray Enterprises
AISWARYA ENTERPRISES
SHAIJAL T M
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .