| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹13.9 L+₹68,306.50 (5.17%)Rejected-Finance 205L MODEL TOWN LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹14.1 L+₹85,563.50 (6.47%)Rejected-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹14.9 L+₹1.7 L (12.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹14.9 L+₹1.7 L (13.0%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
4 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA
COMPREHENSIVE REPAIR TO SERVICES SUCH AS DRAIN HARD STANDING PATH UNDER AGE BR SAMBA AT MIL STN SAMBA
2023_MES_630723_1
GE/SMB/T-59/2023-24
Open Tender
Civil Works
Item Rate
90 days
SAMBA
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹40,000
Yes
5 Feb 2024
6 Dec 2023
6 Jan 2024
6 Dec 2023
4 Jan 2024
22 Dec 2023
6 Dec 2023 - 9 Dec 2023
Amount
Demolition of brick work or stone masonry, built in cement mortar incl all quoins, arches pillars etc but excluding ashlar facing, dressed stone work and precast concrete articals,complete all as specified and as directed.
Demolition of plain cement concrete in ground floors or above ground floor and paving n.exc 15 cm thickness (Below or above ground level), Complete all as specified and as directed .
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth: for foundation etc or for shafts,wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in any type of soil, complete all as specified and directed.
PCC 1:3:6 Type C-2 ( using 20mm graded crushed stone aggregate) for foundation of surface channel and drains, complete all as specified and directed.
Brick work with old size sub class 'B' burnt bricks having crushing strength not less than 75 Kg/Sqm, straight or curved on plan exc. 6 m mean radius built in CM 1:4 as in brick edging, complete all as specified and directed.
Brick work with old size sub class 'B' burnt bricks having crushing strength not less than 75 Kg/Sqm, straight or curved on plan exc. 6 m mean radius built in CM 1:4 as in brick edging but except brick, complete all as specified and directed.
Brick work with old size sub class 'B' burnt bricks having crushing strength not less than 75 Kg/Sqm, straight or curved on plan exc. 6 m mean any radius half brick wall built in CM 1:4, complete all as specified and directed.
Flush pointing to brick massonry in CM 1:4, complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete with fair finished, complete all as specified and directed.
All as per srl item No 9 above but Add or deduct extra 25 mm girth or part therof over or under 30 cm, complete all as specified and directed.
Precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates as in landings, cover slabs (for man holes) etc. and in similar works including chamfers, throating setting in CM 1:6 and necessary form works,Complete all as specified and as directed .
Reinforced concrete pipes 300 mm dia, class NP2, laid and jointed with collars, complete all as specified and directed.
Cement concrete type D-2, 1:4:8(40mm graded crushed stone aggregate) as in foundations,filling and mass concrete, sub base floor, complete all as specified and directed.
Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates as in copings, kneelers, apex stones, bed plates, etc. and in similar works including weathering,slightly rounded or chamfered angles and throating and necessary form works,Complete all as specified and as directed .
Taking down cement plaster on brick/concrete or stone walls, ceiling, etc, including raking out joints, hacking for key, scrugbbing down with water etc, complete all as specified and directed.
Rendering 10 mm thick cement plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement ,complete all as specified and directed.
Rendering 15 mm thick cement plaster in cement mortar 1:4 on brick work or store masonry surfaces and finished even and smooth without using extra cement ,complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Pre-polished chequered cement concrete tiles of size 20 cm x 20cm x 25 mm thick / 25 cm x 25 cm x 25 cm thick, set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 20 mm thick cement screed bed in CM 1:6 complete all as specified and as directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 60mm thick, M-35 grade (Medium Traffic), in paths and hardstanding,with grey cement and pigment, laid tightly over & including 50 mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm, hard & dence soil, complete all as specified and directed.
Removng excavated material (soil) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point,complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc, complete all as specified and directed.
Mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets or ms round bar etc(for securing wire mesh etc.) including all necessary drilling, bolting etc., and similar work conforming to Fe-290 Gde E-165, Complete all as specified and as directed .
Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framwork of water tanks and similar work conforming to Fe.290. Gde-E-165, complete all as specified and directed.
Preparation of new or previously untreated surface of steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Cement concrete 100 mm thick , Type B-2 1:2:4 using 40 mm graded crushed stone aggregate as in apron, complete all as specified and directed.
Cement concrete 50 mm thick , Type B-2 1:2:4 using 40 mm graded crushed stone aggregate as in floor / apron etc., complete all as specified and directed.
Polycarbonate sheet of thick not less than 2 mm and applying self adhesive reflective tape / sheet background of approved tint / colour as in cautionary / sign boards, fixed in repairs, complete all as specified and directed.
Self adhesive retro reflective tape of approved tint / colour for writing alphabets / numbers / letters/ arrows etc. as in cautionary / sign boards/ DTGM boards, complete all as specified and directed. Note- Qty shall be measured based on length / width and height of letters cut from a square / rectangular sheet.
Self adhesive reflective tape background including preparation of surfaces as taking down of existing self adhesive reflective tape background including alphabets / numbers / letters in DTGM / cautionary boards / sign boards, complete all as specified and directed. Note- Alphabets / Numbers/ Letters/ Arrows etc shall be measured and paid separately.
Replacement of existing sign board of size exc. 0.30 sqm but n.exc. 0.75 sqm with following specification or as directed. : (a) Main frame for sign board shall be made of aluminium square / rectangular hollow section not less than 63.50 mm x 38.10 mm x 1.20/1.21 mm including supply and fix of polycarbonate sheet of size exc 0.30 sqm and n.exc. 0.75 sqm both side of aluminium frame. (b) The height of bottom side of board shall be minimum 450mm above ground level or as per user requirment and the board shall be fixed minimum 300 mm below ground level with PCC 1:4:8 Type D-1 using 20 mm graded crushed stone aggregate. (c) The numbers / letters/ digit/ sign/ lines/ arrows etc made of retro reflective tape having reflective tape background shall be fixed over 2 mm thick polycarbonate sheet of approved colour and as directed. Note - Before procurment / supply, sample of board shall be produced by the contractor for approval of GE.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
s k construction co
M/s Sahib and Company
BALI ENTERPRISES
M/S NAGAR BUILDERS
M/S RAJESH SHARMA & CO.
M/S BAWA TRADING CO
THAKUR BUILDERS AND CO
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .