CWE Hills Dehradun
HQ Commander Works Engineers Hills Mall Road Dehradun Cantt Dehradun 248003 Tele 01352757790
ADDITION ALTRATION CUM SPECIAL REPAIR TO OTM ACCN AT RAIWALA MIL STATION
2021_MES_457954_2
86321/RWL/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I Raiwala
Class B Cat a i
6 documents required · 6 mandatory
₹1,000
AGE I Raiwala
₹2.1 L
14 Sept 2021
23 Jul 2021
19 Aug 2021
23 Jul 2021
17 Aug 2021
5 Aug 2021
23 Jul 2021 - 27 Jul 2021
Amount
Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding, safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
M&L 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with liquid water proofing compound (as per manufacture direction and paid separately) over and incl one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/ mortar to old surface as per manufacturer direction and finishing the surface even and smooth(without using extra cement) as in roof padding /sunken floor to receive water proofing treatment complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding, safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note:- 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
Supply only SBR Latex liquid polymer of approved make complete all as specified & directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia complete all as specified & directed.
All as per item no-5 above but 20 mm dia complete all as specified & directed.
All as per item no-5 above but 25/32 mm dia complete all as specified & directed.
M&L for cutting chases on brick or concrete surface for concealed water tubing or / similar work of girth n.exc 10cm including making good of disturbed surfaces with PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) complete all as specified and directed.
M&L for Mild steel galvanized steel tubing of 15 mm bore (ISI Marked) with screwed socket joints as in concealed pipe work , medium grade, together with all fittings heavy grade (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy grade (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed.
M&L for Mild steel galvanized steel tubing of 25 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy grade (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed.
M&L for Mild steel galvanized steel tubing of 32 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy grade (ISI Marked) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed.
S & F in repair 15 mm dia Gun Metal, globe or Gate Valve (ISI Marked) Class 150 with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified & directed.
S & F in repair 20 mm dia Gun Metal, globe or Gate Valve (ISI Marked) Class 150 with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified & directed.
S & F in repair 25 mm dia Gun Metal, globe or Gate Valve Class 150 with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified & directed.
S & F in repair 32 mm dia Gun Metal, globe or Gate Valve Class 150 with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified & directed.
S & F in repairs 15 mm bore fancy type Stop valves, chromimum plated with long shank and cup (concealed type) (ISI Marked) screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified & directed. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S & F in repairs 15 mm bore fancy type Stop valves, chromimum plated with long shank and cup (concealed type) (ISI Marked) screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified & directed. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S & F in repairs 15 mm bore fancy type angle Stop valves, chromimum plated screwed down high pressure with crutch or butterfly handle (ISI Marked) screwed both ends for iron pipe or for unions complete all as specified & directed. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S & F in repairs 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, (ISI Marked) screwed for iron pipe complete all as specified & directed.Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S&F brass chromium plated towel Rail 20 mm dia, D-type, 600 mm long fixed with and including Chromimum plated brass screws and wooden plastic cleats complete all as specified & directed. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S & F in repairs (ISI Marked) Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified & directed. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S & F Glass shelf with Sheet Glass shelf assembly, consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified & directed.
S&F for PVC Connections 15mm size with PTMT nuts of length 300 mm (ISI Marked) complete all as specified & directed.
S&F for PVC Connections 15mm size with PTMT nuts of length 600 mm (ISI Marked) complete all as specified & directed.
S&F for Brass CP urinal spreader fixing with 15 mm dia pipe complete all as specified & directed. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S&F in repair Wash basin of size 550x400mm vitreous china (flat back type) any size (ISI Marked) incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fittings complete all as specified & directed.
S & F in repair for Grating , stainless steel with / without hole, round 125 mm dia chromoum plated Complete all as specified and directed
S&F in repairs 10 liter capacity PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), low level , white, with inlet ball valve, float and handle including brackets and flush pipe suitable for indian Type WC of polyethylene of low or high density or PVC 32 mm dia for low level cistern complete all as specified & directed.
S&F in repairs Vitreous china Squatting pan , 'Orissa pattern, (ISI Marked) of size 580x440 mm white, with integral foot rest excluding flushing cistern and flush pipe including connection to trap, to flushing pipe and anti-syphonage pipe, etc complete including making good to floor complete all as specified & directed.
S&F in repairs Vitreous china wash down water closet pan (padestral pattren) (ISI Marked) white, excluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete all as specified & directed.
S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including connection to flushing pipe and outgoing pipe, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; flush pipe, grating and Union for discharge pipe complete all as specified & directed.
S&F 32 mm dia low density polyethylene pipe (LDPE) of pressure rating @ 6Kgf per Cm Square fixed to walls, ceilings or in floors etc complete all as specified & directed.
S&F Rotational moulded polyethylene water storage tank 2000 liters capacity, white two layer (ISI Marked) construction (cylindrical vertical with closed top), hoisted & fixed in position including all fittings complete all as specified and as directed.
S&F 25mm dia ball valve (ISI Marked) high pressure PTMT with epoxy coated aluminium rod & high pressure plastic ball screwed for iron pipe and fixed complete all as specified and as directed.
S&F in repair 25mm dia ball valve (ISI Marked) high pressure PTMT with epoxy coated aluminium rod & high pressure plastic ball screwed for iron pipe and fixed in repair
Dismantling of cast iron or reinforced concrete drain pipes up to 100mm dia alongwith fittings and accessories, jointed in cement mortar and taking out of wall, floor and trenches if required complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes (ISI Marked) single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes (ISI Marked) single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes (ISI Marked) single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes (ISI Marked) single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) bends (ISI Marked) of any radius complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) bends (ISI Marked) of any radius with access door complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) bends (ISI Marked) of any radius complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) bends (ISI Marked) of any radius with access door complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) junction single (Single `T') (ISI Marked) equal or unequal with access door complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) junction single (Single`T') (ISI Marked) equal or unequal with access door complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) branch piece double (duuble `Y') (ISI Marked) equal or unequal with access door complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) Vent Cowl (ISI Marked) complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) P Trap (ISI Marked) complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) floor Trap (ISI Marked), plain with grating inclding jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) Multi floor trap (ISI Marked) including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm PVC (SWR) WC connector with lip ring complete all as specified and as directed.
S & F PVC (SWR) reducers (ISI Marked) of size 110 mm x75 mm complete all as specified and as directed.
S&F in repair stack clamps out of 50mmx 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to walls or roof for 100 mm pipe, complete all as specified and directed.
S&F in repair stack clamps out of 50mmx 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to walls or roof for 75 mm pipe, complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD all as specified and directed.
M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8 mm thick, as in dado etc incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and as directed. Note:- Shade of the tiles including Colour, design and pattern shall be got approved by AGE (I).
M&L for Non- skid coloured ceramic tiles of any design and pattern, area of each tile exceeding 0.11 Sqm but n.exc 0.18 Sqm ,7 to 8mm thick, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I)
Demolition of lime concrete in floors and paving exe 15 cm thick above ground floor (sunken floor) including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any othet loose material and removing the demolished material outside the MOD land complete all as specified and directed.
M&L for Concrete angle-fillets provided with a radiaus of 75mm to 100 mm at junctions between roofs/chhajja/ sunken floor and vertical faces of walls (parapet, pillar for tank staging and other similar situations) to ease up about corners.with cement concrete 1:2:4 type B0 (Using 12.5mm stone aggregate) mixed with SBR Latex liquid polymer (mixed as per manufacture instructions & will be paid under relivent item of Sch A) including using form work (straight or curved) as required complete as per direction by Engr-in-Charge (Note :- The work is required to be carried out upto double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers. The rates quoted shall deemed to be included for these items.)
Providing and application two coat of acrylic polymer modified cementitious flexible waterproof coating of approved make on horizontal and vertical surface of sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge. Note:- Ponding test after water proofing coating willl be done for 48 Hrs and payment shall be relised to contractor when no leakage/sepage is noticed.
M&L for 15 mm thick cement plaster in CM 1:4 on floor and wall surface of sunken portion with polymer modified repair mortar mixed with SBR Latex liquid polymer ( mixed as per manufacture direction and paid separately).Complete all as specified and directed
M&L for providing 40 mm dia GI pipe spout projecting at least 300 mm beyond outer face of wall complete all as specified & as per direction of Engr-in-charge
M&L for lean concrete 1:5:10 type E2 (using 40 mm graded stone aggregate) as in filling of sunken portion complete all as specified and directed.
M&L for 30 mm thick PCC 1:2:4 Type B-0, (using 12.5 mm graded stone aggregate) as in floor mixed with SBR Latex liquid polymer mixed as per manufactur direction and paid separately under relevent item of Sch A complete all as specified & directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each complete all as specified & directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm but not exceeding 4.0 Sq.m each complete all as specified & directed.
Taking down chowkhats or frames incl shutter (without taking off shutter) of any description n.exe 1.5 Sqm each and refixing in the other opening including providing new MS holdfast , repairing of steel shutter hinges by welding, tightening and making good joints of frame incl replacement of required hardware complete all as specified and directed
Taking down shutter of any description exc 1.00 sqm and not exc 2.00 sqm each and refixing of shutters in other opening of any descrption after easing and adjusting , repairing , tightening the joints of frame of shutter .Complete all as specified and directed
Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each complete all as specified & directed.
S&F for steel windows with side hung shutters (glazed and gauged shutter both) including box type hinges with steel handle, Z section handle and steel peg stay complete with glazing bars, dovetailed or welded including a shop coat of red oxide zinc chrome primer complete all as specified and directed. Note:- Measurements shall be taken and paid compositly for frame, glazed and gauged shutters. Grill shall be measured and paid seperately under respective item of Sch A. No extra claim shall be entertained on this ground.
Providing and fixing windows & ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated(PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 74 X 60mm outer frame , Mullion 72 x 49mm, Glazed shutter 48 x 22mm, Flymesh 41 x 22mm, Beading with round ends for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . Glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat.Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm . Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screws after drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows. . Windows to be procured from any of the below mentioned companies- i)_Ashwani and sons, 1246/2 Meerut Road,Morta, Murad nagar-201003 ii)TATA Steel-Mumbai iii)Jindal,2-32,Gurgaon, Haryana-122001 iv) Ashish Industries, R-4/66, Raj Nagar, Ghaziabad , Ph-9891542779
S&F 1.25 mm thick pressed steel frame of size 105 x60 mm for doors with one or more rebated including necessary fixing lungs, hinges, lock, strike plates etc complete all as specified and directed.
S&F 1.25 mm thick pressed steel frame of size 125 x 60 mm for doors with one or more rebated including necessary fixing lungs, hinges, lock, strike plates etc complete all as specified and directed.
M & L for PCC 1:3:6 type C-0 (using 12.50 mm thick graded stone agg) for filling the core of pressed steel door /window frames complete all as specified and directed.
S & F 2nd class hard wood 35 mm thick glazed and skeleton shutters open rebated and prepared to rceieve glass, gauze,etc. (with sash bars), edges of framing and sash bar moulded, fitted with cut and mitred moulded beads for securing glass/gauze,etc, size of members of shutters as specified in SSR Part-1, Section 8, clause 8.24 (a) etc complete all as specified and as directed.
M&L for 35mm thick, factory made, flush shutters, solid core construction, with block board core and decorative face veneer on both side incl 12 mm thick teak wood lipping alround complete all as specified and directed.
M&L 18 mm thick , prelaminated medium density fibre (MDF) , interior grade, prelaminated one side with decorative choice lamination and other side balancing white with lamination fixed with screw to timber/ steel frame work as in CB shutter, shelves etc with PVC liping on all exposed edges on same texture and shade, stainless steel cleat of suitable size will be use to fix the shelves of CB and cabinets complete all as specified and directed.
S&F Fibre glass Reinforced Plastic (FRP) Door Frames shall be three lagged of cross section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness. The laminate door frame moulded with fire retardant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass from all sides.MS stay shall be provided at the bottom to steady the frame complete all as specified and directed. Make:- M/s Ashwini and Sons Murad nagar, TATA FRP Doors Mumbai, AGEWS Ahemdabad Gujarat, Ashish Industries Ghaziabad.
S & F for FRP paneled door shutter FDR Door shutter shall be 30mm thick glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacturer. Made with fire retardant grade unsaturated polyester resin moulded to 3mm thick FRP laminat for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP panels. complete all as specified and directed. Make: - M/s Ashwini and Sons Murad nagar, TATA FRP Doors Mumbai, AGEWS Ahemdabad Gujarat, Ashish Industries Ghaziabad
S&F Stainless steel butt hinges of size 100mm.(ISI Marked) complete all as specified and directed.
S&F Aluminium anodized barrel tower bolt of size 12mm dia and 300 mm length of extruded section (ISI Marked) complete all as specified and directed.
S&F Aluminium anodized barrel tower bolt of size 12mm dia and 200 mm length of extruded section (ISI Marked) complete all as specified and directed.
S&F in repair Aluminium anodized barrel tower bolt of size 12mm dia and 200 mm length of extruded section (ISI Marked) and fixed complete all as specified and directed.
S&F Extruded Aluminium alloy handles,fabricated type, anodised 100 mm long, (ISI Marked) complete all as specified and directed.
S&F in repair Extruded Aluminium alloy handles ,fabricated type, anodised 100 mm long, (ISI Marked), complete all as specified and directed.
S&F Extruded Aluminium alloy handles,fabricated type, anodised 150mm long, (ISI Marked) complete all as specified and directed.
S&F in repair Extruded Aluminium alloy handles,fabricated type, anodised 150 mm long, (ISI Marked), complete all as specified and directed.
S& F Aluminium alloy anodised sliding door bolt, of size 16 mm dia and 300mm length, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy (ISI Marked) complete all as specified and directed.
S&F in repair Aluminium alloy anodised sliding door bolt, of size 16 mm dia and 300mm length, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy, (ISI Marked) complete all as specified and directed.
S&F in repair hasp and staples , (ISI Marked) size 100mm, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed.
S&F 300 mm , MS ordinary rat tail rod pattern springs (ISI Marked) including roller and plate , door spring fixed to door shutter complete all as specified and directed.
S&F Floor door stopper (ISI Marked) of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm complete all as specified and directed.
S&F in repair Stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples, complete all as specified and directed.
S&F Stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples fixed to door/window shutter complete all as specified and directed.
S&F in repair for high strength Aluminium rod with powder coated paint, 25mm dia with fixing brackets and decorative type knobs both side of each rod ,complete all as specified and directed. Note:- Measurement will be taken between end point of knobs and rates of knob shall be included in unit rate quoted by the contractor.
S&F aluminium peg set of 6 pegs, 300 mm long, complete all as specified and directed.
S&F plain mild steel wire 4mm dia, galvanised class 3, fixed with GI pipes along with straining and necessary fittings in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes, etc complete all as specified and directed.
S&F mild steel adjustable hook both side (min 250 mm to 300mm), solid body, fixed to walls with suitable fastener for fitment of steel wire hanging lines complete all as specified and as directed by Engr-in -Charge.
Dismantling mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F Glazing with plain sheet glass, ordinary quality, 4 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane complete all as specified and directed.
S&F Glazing with figured glass (Frosted), pin head type, 4 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames glazed with putty or fixed with beads or from metal frames including punching or drilling out old glazing pins /spring clips and providing and fixing new one complete all as specified and directed.
M&L Preparation of New wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint (any tint) Ist quality over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width & girth not otherwise described and applying two coat of synthetic enamel paint Ist quality over a coat of red oxid primer complete all as specified and directed.
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated wood and wood based sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) Ist quality complete all as specified and directed.
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated steel sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) Ist quality complete all as specified and directed.
Cleaning of storage water storage tank of RCC/PVC of exc 1000 but n. exc 2000 Ltrs capacity staged over RCC roof/floor slab or similar place inside /outside buildings by removing float valves, inlet and out lets carefully, thoroughly cleaning the entire surface (internal & external), mouth of pipes etc scrubing bleaching powder, to make the tank totally dirt free and finally cleaning the water tank with fresh water till water becomes clear to the entire satisfaction of Engineer-in-charge and as specified in particular specifications and refixing of float valves, inlet and outlet complete all as specified and directed by Engineer-in –Charge. Note:-The contractor will write date of cleaning with black/white synthetic enamel paint on the the surface of tank in the font of sutable size.
Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specified and directed.
M&L cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) 75 mm thick as in plinth protection surface finished even and smooth without using extra cement including 4 mm thick glass dividing strip of figured glass, pin headed type, 73 mm wide inserted in position complete all as specified and directed.
M&L for Cement Concrete Type C2 1:3:6 (using 20 mm graded stone aggregate) in surface channels and drains incl required form work complete all as specified and directed.
Roughening surfaces of old concrete floor by tucking, picking, sweeping clean and washing down with water to remove dust, etc. to receive the screed layer for laying floor tile complete all as specified and directed.
M & L 18-20 mm thick machine cut kota stone slab flooring over cement screed base laid and incl 20 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing and polishing (mirror polished) complete all as specified and directed.
All as per item No-116 above but makrana white as in strip / border of size 10 cm wide in between and around the marble stone slab flooring complete all as specified and directed.
M & L for 18-20 mm thick machine cut pre polished kota stone slab as in tread / cill in full length in single peace without joint, with groove cutting in triple line of stair width of stair case over and incl 20 MM thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing and polishing incl full round bull nosing complete all as specified and directed.
M & L for 16-18 mm thick machine cut pre polished kota stone slab as in riser of steps, skirting in full length in single peace without joint, of stair width laid over and incl 10 mm thick rendering of CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade including necessary grinding, rubbing and polishing complete all as specified and directed.
M & L of 16-18 mm thick pre polished udaipur green stone (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms , basin counters and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of stone incl full round bull nosing and making hole for gas pipe complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) ,complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L for cutting out bricks, forming toothing for and bonding new into old work and jointing and pointing in CM 1:4 complete.(measured on vertical face in contact with old wall only) complete all as specified and directed.
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed.
M&L rendering 5 mm thick in CM 1:3 in ceiling / Chhajja's finished even and smooth (without using extra cement) complete all as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick work or concrete walls internal surfaces in CM 1:6 finished to even & smooth without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete walls internal surfaces of toilets area with polymer modified repair mortar (SBR Latex liquid polymer will be mixed as per manufactur direction and will be paid separately under relevent item of Sch A) complete all as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick work or concrete walls external surfaces in two layerss first layer of 10 mm in CM 1:6 & 2nd layer of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth without using extra cement complete all as specified and directed. Note:- Integral water proofing liquid will be measured and paid seperately under relevent item of Sch A.
Supply only Integral water proofing liquid ISI Marked as approved . Complete all as specified and directed
M&L rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete walls external surfaces of toilets area and shaft and RCC column with polymer modified repair mortar (SBR Latex liquid polymer will be mixed as per manufactur direction and paid separately under relevent item of Sch A) complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old surface plastered or unplastered and applying two coat of white wash on ceiling complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new surface plastered or unplastered and applying three coat of white wash on ceiling complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper using roller all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge . Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M&L for white washing three coats on walls incl preparation of newly plastered surfaces complete all as specified and directed by Engr In Charge.
M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including cutting reinforcement required to facilitate demolition upto and including on the roof top/mumty/parapet/RCC chajjas, fins, floor, beam & similar suspended work /RCC water tank and removal of debris and rubbish out side MoD land complete all as specified and directed.
S&F factory made, 70mm thick precast steel fibre reinforced concrete (SFRC) of any shape and size, manhole / drain cover (medium duty) provided with handle, incl 8mm dia MS TMT bar @ 150mm c/c in both ways and 0.8mm thick MS sheet frame epoxy painted provided to manhole /drain cover to prevent from chipping pf edges complete all as specified and directed.
M&L RCC 1:1.5:3 type A1 (using 20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc incl one coat of cement slurry over full thickness of old RCC member admixed with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/ mortar to old surface as per manufacturer direction complete all as specified and directed.
M&L RCC 1:1.5:3 type A1 (using 20 mm graded aggregate) in chajjas/fin/facia and similar work incl one coat of cement slurry over full thickness full thickness of old RCC member admixed with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/ mortar to old surface as per manufacturer direction complete all as specified and directed. Note:- 1. The work is required to be carried out upto double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers. The rates quoted shall deemed to be included for these items.)
M&L RCC 1:1.5:3 type A1 (using 20mm graded aggregate) for beams, cantelever, lintels over 1.50 m span supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etcincl one coat of cement slurry over full thickness of old RCC member admixed with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/ mortar to old surface as per manufacturer direction complete all as specified and directed. Note:- 1. The work is required to be carried out upto double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers. The rates quoted shall deemed to be included for these items.)
M&L for mild steel deformed bars or TMT bars 10mm dia & over, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel deformed bars or TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Formwork with steel props to soffits of suspended slabs such as roof slabs, floor slabs, landings , chajjas, and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
Form work to sides and soffits of floor or roof beam , lintels etc complete all as specified and directed.
M&L for drilling 12 mm dia x 200mm deep in various structrural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive Sika AnchorFix - 2+ Tropical or equivalent of approved make complete all as specified and directed.
M&L for cement concrete type C1, 1:3:6 (using 20 mm graded stone aggregate) in foundation, sub base of flooring/ hard standing/footpath, etc complete all as specified and directed
M&L for PCC 1:2:4, type B0 (using 12.50 mm stone aggregate) as in lintel , cills, steps, plinth course, copings, bed plate, hold fast , kerbs etc incl necessary form work complete all as specified and directed.
M&L for Prepolished chequered cement concrete tiles 300X300X25 mm thick, rubber finished (ISI marked), as in floors laid over 20 mm thick screed bed in cement mortar 1:6 jointed with grey cement slurry mixed with pigment to match the shade of the tiles including removal of old materials from site not exceeding 100 meter, complete complete all as specified and directed
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade Fe-410 gde st- 240 complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa (AZ 150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F expended metal, cut to length , bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm dia or fixing with galvanized steel staples or by welding fixed to steel frame, weight N exe 4 Kg/sqm complete all as specified and directed.
M&L for post construction Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for post construction Anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
M & L for cutting of bushes small trees (Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet between sanitary pioe and wall etc at any height by using herbicide compound for root killer or plant killer and necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and incl material and labour in CM 1:4 mixed with WPC /PCC 1:3:6 type B0 /Bk work in CM 1:4 as required at site complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation in hard/ dense soil and getting out complete all as specified and directed.
Demolition and breaking up drain pipes , 150 mm dia (Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar and removing unserviceable material outside of A1 defence land complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description & any position and not otherwise specifically provided for and removing unserviceable material outside of A1 defence land complete all as specified and directed.
M&L Concrete bed to drain pipe 150 mm dia incl. packing under and haunching against the sides of pipe in PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) complete all as specified and directed.
S & F 150 mm bore reinforced concrete Soil pipe , c;lass NP2, laid and jointed in floors or trenches complete all as specified and directed.
Returning filling in including spreading, levelling , watering and well ramming n exc. 25 cm in layers (Soil) complete all as specified and directed.
Removal of excavated surplus (soils) at a distance exc. 1.5 Km but n. exc 5.0 Km complete all as specified and directed.
Taking down carefully burnt and unserviceable point wiring, copper/ aluminium for light, fan, socket, power) complete including switches, ceiling roses , pendants, regulators , sockets etc and removing materials to store and making good the disturbed surfaces of walls, floors etc complete all as specified & directed.
Taking down service/sub main wire of any size fixed n any positon, comlete all as specified and directed.
M&L Point wiring with 1.5 Sqmm (Nominal area) FRLSH PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor in and including concealed rigid PVC conduit(ISI marked) medium grade of size not less than 20 mm dia including accessories incl cutting chases , making surface good etc along with contineous earth wire 1.5 Sqmm FRLSH PVC insulated , unsheathed stranded copper conductor cable and connected to common earth dolly, with and including 1.6mm cadmium plated sunk MS pressed steel terminal boxes with 3.0 mm thick hylum sheet cover ISI marked fixed with brass screw complete with all accessories. Make of PVC pipe:-Finolex,RPG,ESS ESS Kay complete all as specified & directed for the following.
All as per Item No -167 above description for One light /ceiling fan /exhaust fan point controlled by one no of one way 5/6 switch complete all as specified and directed.
All as per Item No -167 above description One 5 pin 5/6 Amps socket outlet point on independent board controlled by one, one way switch single pole 5/6Amps complete all as specified and directed.
All as per Item No -167 above description but on the same board with other switches /socket complete all as specified and directed.
All as per Item No -167 above description but controlled by two way point wiring controlled by 02 Nos of two switch with cables 1.5 sq mm size in PVC conduit complete all as specified and directed.
M&L Point wiring with 2.5 Sqmm (Nominal area) FRLSH PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor in and including concealed rigid PVC conduit(ISI marked) medium grade of size not less than 20 mm dia including accessories incl cutting chases , making surface good etc along with contineous earth wire 2.5 Sqmm FRLSH PVC insulated , unsheathed stranded copper conductor cable and connected to common earth dolly, with and including 1.6mm cadmium plated sunk MS pressed steel terminal boxes with 3.0 mm thick hylum sheet cover ISI marked fixed with brass screw complete with all accessories for 16 Amp power point on independent board complete all as specified & directed for the following. Make of PVC pipe:-Finolex,RPG,ESS ESS Kay
S&F switch piano 230 volts, AC, flush type single pole, one way 5/6 Amps ISI marked complete all as specified and directed of Anchor Cat part no HSN8536/14111 or of Cona cat part no HSN 8536/7021 or equivalent in Havells.
S&F switch piano 230 volts, AC, flush type single pole, two way 6 Amps ISI marked complete all as specified and directed of Anchor Cat part no HSN8536/ 14112 or of Cona cat part no- HSN 8536/7006 or equivalent in Havells.
S&F switch piano flush type white /ivory finish 15/16 Amps single pole one way ISI Marked 50 Hz complete all as specified and directed of Anchor Cat part no HSN 8536 or of Cona cat part no-HSN 8536/7081 or equivalent in Havells.
S &F socket out let 2 pin 5/6 Amps & 3 pin 5/6 Amps flush type ISI Marked 50 Hz complete all as specified and directed of Anchor Cat part no-HSN8536/14302 or of Cona cat part no- HSN 8536/7021 or equivalent in Havells.
All as per item no-176 above but of 5/6 pin 15/16 Amps ISI Marked 50 Hz complete all as specified and directed of Anchor cat part no- HSN 8536/14307 or of Cona cat part no-HSN8536/7091 or equivalent in Havells.
S&F ceiling rose surface Bakelite AC ISI Marked 50 Hz 220/240 volts 3 terminals complete all as specified & directed of Anchor Cat part no HSN 8536/39072 or of Cona cat part no HSN 8536/2116 or equivalent in Havells.
S&F LED tube light batten 20 watts 4 fts polycarbonate housing, translucent diffuser with LED light source , 2200 lumen, natural white ,surge protection range 2KV, voltage protection range 120-280 VAC , 2 years warranty ,system efficacy not less than 110 Lm/watt for the fitting , power factor>0.95 total harmonic distortation<20% , colour rendering index >80, coefficient colour temp 6500 K, fixed on site with all accessories all as specified and directed. Make Shakti cat part No SZSLBMX020 or equivalent in Havells , wipro or bajaj LM79 and LM80 reports to be produced . BIS certification must .
S& F double door sheet metal enclosure for DB , 04 way , SPN, with 200 Amps rated bus bar , 240 Volts suitable for housing MCBs and isolator and making good for disturbed surface with existing etc complete all as specified & directed.
S& F double door sheet metal enclosure for DB , 08 way , SPN, with 200 Amps rated bus bar , 240 Volts suitable for housing MCBs and isolator and making good for disturbed surface with existing etc complete all as specified & directed.
S&F 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, ISI marked, 230 Volts, 50 Hz in the MCB DB and connecting the cable with suitable size of copper lugs Complete with connection testing and commissioning complete all as specified & directed.
S&F 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and Neutral current carrying capacity 40 AMP, ISI marked, 230 Volts, 50 Hz in the MCB DB and connecting the cable with suitable size of copper lugs Complete with connection testing and commissioning complete all as specified & directed.
S& F MCB DB VTPN sheet steel powder coated double door, 6 way , 415 Volts, ISI marked, 50 Hz with insulated vertical phase bus bars, neutral bars with shrouds, earth bars, sticking saddles, cement spill protector, color coded interconnecting wire set cable, blanking plates and circuit identification lables with provision for 01 No of 3 Pole MCCB as incomer and 18 Nos MCB SP as outgoing complete all as specified and directed by Engr-in-Charge. Note:- MCCBs and MCBs measured and paid separately under relevent item of Sch A.
S&F TPN MCCB 63 Amp, 50 Hz, 415 V , ISI marked 50 Hz with rupturing capacity 25 KA complete all as specified & directed.
M & L for sub main wiring with two run of 4 Sqmm (nominal cross sectional area ) of single core unsheathed PVC insulated FRLS-H cable 1100 Volts grade multi stranded copper conductor drawn through & including non metallic rigid PVC conduit of size 19/20 mm or higher dia with & including necessary conduit accessories concealed/surface (only on roof & colomn) type including 4.0 Sqmm PVC insulated FRLS-H cable 1100 Volts grade multi stranded copper conductor as earth wire connected to common earth dolly complete all as specified & directed. Note:- Two runs of pahse and neutral wire and one run of earth wire with PVC conduit will be measured as one unit.
M& L, for earthing with galvanised steel earth plate of size 600 x 600 x 6 mm thick burried directly in ground not less than 2.5 mtr below groud level with top edge of earth plate not less than 1.5 meters below ground level connected by 4 mm dia GI wire as earth lead by means of brass nuts and bolt, thimbles, check nuts, washers surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate including concrete chamber of PCC 1:3:6 type C1 using 20 mm graded stone aggregate, with fair finish, inetrnal surface of concrete chamber shall be given internal dia 300mm X 300mm , 15 mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320 x 320 x 80 mm size (1:2:4) type B1 using 20 mm graded stone aggregate, adequate quantity of common salt, charcoal etc all, as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified incuding and provision of GI strip upto 7.5 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, Medium grade, including all excavation and earth work and connecting the earth strip to an earthing test point/panel including testing on completion complete alll as specified and directed by Engr-in-charge Note:- (1) RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 Kg/Sqm in lieu of CI cover (2) Cost of addtional GI wire more than 7.5 mtr will be measured and paid seperately under relevant item
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
S & F Batten Holder mounted on wall ISI marked all as specified and directed.
S&F exhaust fan, steel body, metal ventilation, double ball bearing AC single Phase. 230V 900 rpm of size 300m,sweep with, blades, and frame and louvers with necessary core cutting of any type wall bricks or stone wall complete and making surface good and necessary wiring and connection complete all as specified and directed by Engr-in-Charge.
Material and labour for fixing or passing through pipe, laid in trenches, fixed on wall, LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 25 sqmm 4 core with required aluminium cable lugs, lugs should properly crimmping with crimpping tools, heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirement all as specified and directed. by Engr-in-charge. Note:(i)GI tubing required shall be measured and paid separately under relevant item of sch as supply only, (iii) Heat shrink sleeve of 25mm long on HS joint for colour indication shall deemed to be included on the quoted rate.
Excavation in trenches not exceeding 1.5 mtr wide and not exc.1.5 mtr in depth for poles /laying of electric underground cables and GI tubing (where provided for protection of cables) and getting out trimmimg the sides, forming bottom surface to required level in any type of soil complete all as specified and directed.
M&L for fine dry sand cushing for under ground cable by providing layers of sand 8cm deep before laying and 15cm deep after laying the cable including streching the cable complete all as specified and directed .Note :- Punned (consolidated ) thickness of sand will be measured .
M&L for cable protection bricks common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches all as specified and directed at site.complete all as specified and directed.
M&L for road cutting and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) of 150mm X 100mm inrespect of width and thickness complete all as specifed & as directed by Enger -in- charge.
Supply only GI tubing light grade 40mm bore, ISI marked, for cable protection complete all as specified and directed.
Supply and fix LED street/security light fitting 20W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts AC, 50 HZ, consisting of reflective lens wired with approximate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level > 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiency > 120 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700 K- 6500 K including fixed on wall with 02 Nos MS clamp made out of 40 x 6 mm F1 and bracket made out of 32 mm dia light grade GI pipe not less than 0.9 mtr long bend to shape including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volta grade all as specified and as directed by Engr-in-Charge Make : shakti Cat Part No : SZPSLPM020/ ENDURAPEARLSL20W of HEVELLS/eauivalant Model in Bajaj/CROMPTON. Note :- (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 & LM 80 report from any NABL approved laboratory. (iii) The fitting should have BIS, CRS (iv) Connection to luminaire shall be done with suitable PVC connector within the bracket/luminaire end.
Sahil Builders
M/s Kuldip Singh Sethi
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .