Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC 512 CHITTILAKATTU IRIPANAM TRIPUNITHURA ERNAKULAM KERALA 682309 | ERNAKULAM | KERALA | 682309 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.9 L+₹90,760 (15.2%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.3 L+₹2.3 L (38.4%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹10.2 L+₹4.3 L (71.5%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
Closing Date
13 Sept 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sunilkumar K A
Deputy General Manager (Projects and Planning), FACT (Cochin Division), Ambalamedu Ernakulam
Instrumentation Maintenance Assistance in Acid area at FACT-CD, Ambalamedu
2021_FACT_645196_1
04028/2021-2022/E23898
Limited
Miscellaneous Works
Item Rate
365 days
AMBALAMEDU
This tender is issued on limited tender basis from the registered bidders of FACT (CD) (list CDN105,CDN106,CDN111)
4 documents required · 4 mandatory
₹0
Exempted
9 Oct 2021
27 Aug 2021
14 Sept 2021
27 Aug 2021
13 Sept 2021
27 Aug 2021
180 days
Assistance for Instrumentation Maintenance Work in FACT–CD Acid area
pH meter checking The work includes removal of pH sensor from line, cleaning of sensor as per standard procedure, calibration checking of pH sensor as per procedure using standard buffer solutions after connecting with transmitter. All materials for the job will be provided by FACT free of cost.
Removal and Refixing of Temperature Elements with Thermowells/Thermowell pockets: The work includes removal of Thermowell-element assemblies/Thermowell pockets (Flange size upto size 1.5 inch, length upto 1500mm) for inspection, refurbishing the fittings, leak checking, minor welding if required for leak proofing and fixing back with proper gaskets, nuts and bolts. Note: All materials required for the work will be provided by FACT free of cost.
SO2 Stack Analyser Calibration checking: Work includes Calibration checking of SO2 Stack Analyser in Sulphuric Acid Plant as per standard procedure using the Zero and Span Gas cylinders provided. Prior to the Calibration check, the Sample handling system components to be checked of any leaks and purging/clearing any dirt/Acid accumulations inside any of the components. All materials for required for the work will be supplied by FACT as free issue. The work shall be carried out according to the instruction from the shift-In-Charge.
Removal and Refixing of Instruments from Process Line/Vessel: The work includes removal of Pressure, Level transmitters/switches, Level gauges and Pressure gauges (End connection flange size upto 4", rating up to 150#), Magnetic/Mass flowmeters, Control valves etc (flange size upto 1", rating upto 150#) from plant site, transporting them to Instrumentation lab / workshop for inspection/repairs etc., bringing back to site and fixing back in position, at site with proper gaskets, bolts & nuts, ensuring leak proof connection. Note: All materials required for the work will be provided by FACT free of cost.
Cell cleaning and Calibration checks- Ammoniacal Nitrogen analyser: Work includes Calibration checking of Ammoniacal Nitrogen Analyser in Effluent Treatment Plant as per standard procedure using Standard Buffer Solutions. Prior to the Calibration check, the sensor cells to be removed from the Drain channel and cleaned thoroughly. All materials for required for the work will be supplied by FACT as free issue. The work shall be carried out according to the instruction from the shift-In-Charge
Cell cleaning and Calibration checks- Flouride analyser: Work includes Calibration checking of Flouride Analyser in Effluent Treatment Plant as per standard procedure using Standard Buffer Solutions. Prior to the Calibration check, the sensor cells to be removed from the Drain channel and cleaned thoroughly. All materials for required for the work will be supplied by FACT as free issue. The work shall be carried out according to the instruction from the shift-In-Charge.
Refurbishment of Float & Rope for Tank Level Measurement: The work includes refurbishment of float and rope type level indicators of various storage tanks with new rope and float as required. The scope of work includes fabrication of float and accessories, transportation of all necessary items from Stores / Workshop to site, and installation as per instructions from the Engineer-in-Charge. Note: All materials required for the work will be provided by FACT free of cost.
Fabrication and Fixing/Mounting of Instrument stanchions: The Work includes fabrication of instrument stanchion (size 50 NB, SCH80 MS pipe, length approx. 130cm) with base plate of size 225mm X225mm X 6mm and fixing the stanchion using anchor bolts or welding on "I" beam / Channels. Note: All materials required for the work will be supplied by FACT as free issue.
Fabrication and Fixing/Mounting of field Instrument supports: The work includes fabrication of instrument supports (size 50 NB, SCH80 MS/SS pipe,"L"shape size 300X 200mm approx) and fixing the support using anchor bolts or welding on "I" beam / Channels. Note: All materials required for the work will be supplied by FACT as free issue.
LAYING STAINLESS STEEL TUBE-6&8MM The work includes laying of 6mm/8mm SS pneumatic tubing between air headers, air filter regulators, I/P Converters etc of control valves located at the plant site. The tubing will involve providing standard SS fittings from air header to control valve accessories as required. Ends shall be connected at air header tapings, air filter regulator or I/P Converter. Sharp bends shall be avoided and proper support shall be given using clamps for the pneumatic tubing. All materials required for the work will be supplied by FACT as free issue.
Impulse line Tubing for Transmitters up to 12mm SS: The work includes laying of the SS tubes/pipes(sizes 12mm) on angle supports, clamping, interconnection with suitable fittings, termination of tube at both the ends, providing of SS identification tags wherever necessary and pressure testing from the instrument 1st isolation valve to flow/pressure transmitter, Level instruments etc. Sharp bends shall be avoided and proper support shall be given using clamps for the pneumatic tubing. Note: All materials required for the work will be supplied by FACT as free issue
FIXING OF ENCLOSURE GRP,FIELD INST The work includes fixing of FRP/ GRP diagonal enclosure of size 450X400X400 (W X D X H) approx for existing field instruments. The enclosure shall be fixed using mounting brackets/ U clamps, nuts and washers (SS 304 material) on 2" pipe/ pedestal/angles. All materials required for the work will be supplied by FACT as free issue.
FIXING OF CANOPY GRP,FIELD JB The work involves fixing of FRP/ GRP canopies of size 550X 450X 325mm (W X D X H) approx for existing junction boxes. The canopies shall be fixed using mounting brackets/ U clamps, nuts and washers (SS 304 material) on 2" pipe/ pedestal/angles. All materials required for the work will be supplied by FACT as free issue.
FIXING OF CANOPY GRP,FIELD INST The work includes fixing of FRP/ GRP canopies of size 360 X 445 X 370mm (W X D X H) approx for existing field instruments. The canopies shall be fixed using mounting brackets/ U clamps, nuts and washers (SS 304 material) on 2" pipe/ pedestal/angles. All materials required for the work will be supplied by FACT as free issue.
Fabrication and Fixing of Ladder ype Aluminum Cable tray (250mmto 400mm): Aluminum Angles and Flats (for carrying out this work) will be supplied by FACT free of cost. The scope of work includes transportation of all necessary items (including free supply items from FACT) from Lab / Stores to site. The work also includes Fabrication of ladder type cable racks of sizes 25cm to 40cm using Aluminum angles (65x65x6mm or 50X50X6mm) and their erection. Aluminum flats of size 50X8mm shall be used as cross bars and shall be provided at intervals of 50cm(for horizontal run) by drilling two numbers of holes at each end and fixing it with fasteners [fasteners (SS bolt, SS nut and SS washers to be supplied by contractor (M8X40mm) and two washers]. The cross bar shall be provided at 30cm intervals for vertical run of the trays. Fixing of the rack to the existing structures shall be using suitable MS angle welded supports or using proper anchor bolts, wherever required and as decided by the Engineer-in-Charge. The work shall include painting of MS supports with two coats of anti-corrosive epoxy paint (grey colour) over two coats of suitable primer. Epoxy paint and primer shall be provided by FACT.
Laying of Signal/Power Cables - 1 Pair/1 Triad/2 Triad/3 Core: The work includes transportation of cables to site, Installation of signal/ power cables-1 pair/1 triad/2 Triad/3 Core with wires of size 0.5/1/1.3/2.5 SQMM by laying on new/existing cable tray/rack/clamping on the wall/structure/routing through GI pipe/trenches. The cables are to be laid from junction boxes to field instruments. Dressing of cables in racks shall be using Aluminum strips of size 20x5mm at intervals of min. 1 meter on horizontal runs and 30 cm on vertical runs. The scope of work includes fixing identification tags on both end of the cables before entering the instruments, junction boxes or control room. The tags may be tied to the cable using SS wires. The aluminum flat strips shall be fixed using M6X40 SS Fasteners. The supply of fasteners and SS wire as detailed above is in the scope of contractor. Note: Cables and identification tags will be supplied by FACT free of cost.
Laying of Signal/Power Cables - 12 Pair/20 Pair/24 Core: The work includes transportation of cables to site, Installation of signal/ power cables-20 pair/12 pair/24 core with wires of size up to 2.5 SQMM by laying on new/existing cable tray/rack/clamping on the wall/structure/routing through GI pipe/trenches. The cables are to be laid from junction boxes to Junction Boxes/DCS Control Room. Dressing of cables in racks shall be using Aluminum strips of size 20x5mm at intervals of min. 1 meter on horizontal runs and 30 cm on vertical runs. Clamping of cables on structure shall be by welding and fixing suitable cleats. The scope of work also includes fixing identification tags on both end of the cables before entering the instruments, junction boxes or control room. The tags may be tied to the cable using SS wires. The supply of fasteners and SS wire as detailed above is included in this item. Note: Cables and identification tags will be supplied by FACT free of cost.
Dressing and Arranging of existing Cables on Prefabricated Aluminum Trays of size upto 200mm: The work includes removal of cables of various sizes from MS/Aluminum slotted trays, and arranging and Dressing of the cables in Angle/Ladder type Aluminum cable racks using SS wire/Aluminum Flat strips(20x5mm) at intervals of min. 50cm on horizontal runs and 30 cm on vertical runs. The aluminum flat strips shall be fixed on the Aluminum angle tray using M6X40 SS Fasteners. Supply and installation of all other items required for the completion of work like SS wire, nuts, bolts, washers etc., and transportation of removed cables to scrap yard are also included in this item. Note: The rate shall be for dressing of cables of various sizes (up to 4-5 branch/multicore cables) on unit length of cable tray.
Dressing and Arranging of existing Cables on Prefabricated Aluminum Trays of size Above 200mm: The work includes removal of cables of various sizes from MS/Aluminum slotted trays, and arranging and Dressing of the cables in Angle/Ladder type Aluminum cable racks using SS wire/Aluminum Flat strips(20x5mm) at intervals of min. 50cm on horizontal runs and 30 cm on vertical runs. The aluminum flat strips shall be fixed on the Aluminum angle tray using M6X40 SS Fasteners. Supply and installation of all other items required for the completion of work like SS wire, nuts, bolts, washers etc., and transportation of removed cables to scrap yard are also included in this item. Note: The rate shall be for dressing of cables of various sizes (up to 4-5 branch/multicore cables) on unit length of cable tray.
Signal/Power Cable Glanding (1/2") : The work includes transportation of all necessary items to site, Glanding of signal and power cables of size 1 Pair/1 Triad at junction boxes and field using double compression/single compression glands of size 0.5 inch. The glanding shall be done with good workmanship, and securing of glands shall be proper and tight. Stripping of insulations from wires shall be done without nicking the conductor. Standard stripping tools of proper design shall be used for carrying out the work. Note: Cable glands will be supplied by FACT free of cost.
Signal/Power Cable Glanding (1.25-1.5") : The work includes transportation of all necessary items to site, Glanding of signal and power cables of size 20Pair 12 Pair/24 Core at junction boxes using double compression/single compression glands of size 1.25 inch and 1.5 inch. The glanding shall be done with good workmanship, and securing of glands shall be proper and tight. Stripping of insulations from wires shall be done without nicking the conductor. Standard stripping tools of proper design shall be used for carrying out the work. Note: Cable glands will be supplied by FACT free of cost.
Supply of Unskilled Labor (8HR SHIFT BASIS) : Charges for providing services of the following category of workers with tools on 8 hour shift basis (mandays) for attending works including installation/ repair/calibration/commissioning assistance for FACT during execution of the contract. The type of work includes re-routing, dressing and clamping of existing cables (various sizes – 20pair,12 pair, single pair etc), existing pneumatic tubes (sizes up to 12mm), from damaged cable trays onto new cable trays, and removal of existing cable trays, removal and re-rolling of old cables for disposal, cleaning of instrument panels, control valves, covering with polythene sheets for protection etc and transportation of instruments (including control valves, flow meters, transmitters etc. and materials from site to Lab/workshop/scrap yard as required. The charges shall include supervision of the workmen.
Supply of Skilled Instrument craftsmen (8HR SHIFT BASIS) : Supply of skilled Instrument craftsman for attending miscellaneous instrumentation works viz. assisting instrument technician in doing preventive maintenance, installation of new instruments, providing instrument tags and cable tags through punching on aluminum strips and tying on cables, junction boxes etc with SS ties as per the instrument list provided by instrumentation dept. Cable glanding and termination in instrument and junction box. Replacement of damaged mounting brackets, manifold, bolts/ nuts of instruments, isolation valves and fitting, other revamp works, including minor welding works etc with new items supplied by FACT. Providing service such as transporting of equipment/ instrument cable/ valves/ transmitters, cleaning of control panels/ marshalling boxes/ local panel instruments/ field equipment/ instruments, re-rolling and shifting of cables, scrap materials and E-waste removal from field/ workshop/ control room to warehouse/ store yard/ scarp yard and vice-versa. They shall work on 8-hour shift basis as directed by Engineer in charge. They shall be minimum ITI/ITC Instrumentation/Electronics or equivalent NCTVT with relevant experience -apprenticeship / job experience etc.
HASSAN MM
BABY B
Inkal Ventures
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_679143.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .