Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.7 L+₹861.28 (0.02%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹35.0 L+₹35,558.66 (1.03%)Rejected-AOC VILL SINGIMARI PO KALAIGAON DIST UDALGURI ASSAM | L3 | Rejected-AOC L3 |
Tender Value
₹34.7 L
EMD Value
₹69,311
Closing Date
14 Feb 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Addl. Chief Engineer cum Director, PWD, BTC
O/o the Addl. Chief Engineer cum Director, PWD BTC, Kokrajhar.
Infrastructure Development at Tangla Higher Secondary School in Udalguri Dist. under SOPD fund for the financial year 2021-22.
2022_BTC_24206_1
ACE-35/TECH/UDL(RB)/IFB/18-19
Open Tender
Civil Works
Works
120 days
Udalguri Dist.
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,050
Principal Secretary, BTC, Kokrajhar
₹69,311
Yes
12 Apr 2022
3 Feb 2022
14 Feb 2022
3 Feb 2022
14 Feb 2022
3 Feb 2022
3 Feb 2022 - 14 Feb 2022
180 days
Amount
2.8: Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil
11.2.: Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
4.1.: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5: 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 20 mm nominal size)
5.22.: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4 Hot rolled deformed bars
FORM WORK 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.
5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.3: Suspended floors, roofs, landings, balconies and access platform
5.2.: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-11): 3 graded stone aggregate 20 mm nominal size)
5.2.: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
6.1.: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand).
2.27. : Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
4.10: Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
6,13 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand).
10.14: Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, ......Engineer-in-charge: 10.14.3 Profile E 10.14.3.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
10.11: Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
9.48 : Providing and fixing M.S. grills of required pattern in frames of windows etc. with M. S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding
11.5 62mm thick cement concrete flooring with concrete hardener topping, under laying 50mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layers 12mm thic cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening comound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
13.2: 15mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1: (1 cement : 4 fine sand)
9.5: Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1 : Second class teak wood 9.5.1.1: 35 mm thick shutters
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (Zone-III) : 6 graded stone aggregate 20mm nominal size) over 75mm thick bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing the top smooth.
13.41 Distempering with oil bound washable distemper of approved brand nand manufacture to give an even shade : 13.43.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
13.43 Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface: 13.43.1. Water thinnable cement primer
13.45.1: Finishing walls with textured exterior paint of required shade : 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Electrical Work 1.8 :- Wiring for light point/ fan point exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm. Copper conductor single core cable etc. as required. 1.8.1 Group A
1.8.2. Group B
1.14 :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 x 2.5. sq. mm + 1 x 2.5 sq. mm earth wire
1.14.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
1.22 :- Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of plenolic laminated sheet cover in including painting etc. as required. 1.22.2 100 mm x 100 mm x 60 mm deep
1.22.5 180 mm x 100 mm x 60 mm deep
1.22.9 200 mm x 250 mm x 60 mm deep
1.24 :- Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
1.24.4 3 pin 5/6 socket outlet
1.28 :- Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.2 3 Module
1.28.5 8 Module
1.28.6 12 Module
1.29 :- Supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A. socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
1.33 :- Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.34 :- Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.41 :- Installation, testing and commissioning of pre-wired, fluorescent fitting /compact fluorescent fitting of all types complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.45 :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on the fan etc. as required.
2.3 :- Supplying and fixing following way, single pole and neutral, shee steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 2.3.1 6 way, Double door
2.10 :- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
2.12 :- Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1 40A
5.2. Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking. Arrangement and watering pipe eat. With charcoal/ coke and salt as required.
5.17 :- Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
7.1:- Laying of one number PVC insulated and PVC sheathed / XL power cable of 1.1 KV grade of following size direct in gro including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.1 Upto 35 sq. mm
MR-1:- Supplying with including fitting fixing Of ceiling fan etc. as directed by the Deptt.
MR-3:- Supplying with including fitting fixing of LED Tube light etc. as directed by the Dept.
MR- Supplying with including fitting fixing of LED Bulb 9 Watt. Etc. as directed by the Deptt.
MR - :- Supplying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminium conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium wire for single core up to 70 sq. mm balance Aluminium strip, Glavanised wire for cables up to 2 x 10 sq. mm, 3 x 10 mm, 3 x 10 sq. mm, 4 x 6 sq. mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (Part-1) 1988 armored U.G. cable as specified and directed by the deptı. (Havells, RR, or equivalent make as approved by this Deptt.) 4.00 sq.mm 2 Core U.G. Cable Considering 100 Mtr. Length.
MR-14 :- Supplying and fitting fixing 2 H.P. Single phase Centrifugal Mono block Pump set sync speed 2900 rmp. Model No. KDS 213with DOL Starter Control & switch gear (1 BCH/L&T/Siemens/ equivalent make). With all accessories complete as required and as directed by the department.
MR-:- Supplying with fitting and fixing single phase service connection with tested Digital type energy meter including load Security Labour charge, Nuts & bolt, GI wire.
MADAN DEBNATH
PANKAJ DEBNATH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .