Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | ₹20.9 L | L1 | Accepted-AOC SINCE L1 ACCEPTED |
| 2 | L2₹21.2 L+₹24,145 (1.15%)Rejected-AOC | ₹21.2 L+₹24,145 (1.15%) | L2 | Rejected-AOC SINCE L2 REJECTED |
Tender Value
₹21.4 L
EMD Value
₹50,000
Closing Date
22 Jun 2020, 6:55 pmClosed
Executive Engineer, H E Electrical Division
Executive Engineer, Harbour Engineering Electrical Division, Kamleswaram. Thiruvananthapuram
Fisheries _ National Fish Seed Farm at Neyyar_Phase 3 Development_ Providing blower power supply to Ornamental Fish Farm
2020_HED_364230_1
04/HEED/2020-21/S
Open Tender
Electrical Works
Item Rate
90 days
At Neyyar Dam in Thiruvananthapuram
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,332
online
₹50,000
Yes
29 Sept 2020
12 Jun 2020
25 Jun 2020
12 Jun 2020
22 Jun 2020
12 Jun 2020
Amount
Fabricating, supplying, conveying, lifting and erecting tubular post of overall height of 7m using 6m 80mm and 1.5m 50mm Heavy G.I. Pipe with suitable mounting pipe for fixing led fitting with socket diameter 32-40 mm having ISI mark and of approved quality as per the drawing, erected on a RCC 1:2:4 foundation in 3 Nos well steining of 0.3m depth and 0.6m dia. with muffing of 0.45x0.45m with height 1.0 m. The post shall be erected on 4 numbers of 20 mm dia GI foundation bolts of length 2.0 m having 100mm long standard thread with a 20 mm thick GI flange suitable for 80mm C class pipe at the bottom of the post and 80 D flange on the muffing with 4 nos of 20mm bolt holes and 3Nos of 20mm nuts per bolt. The bottom of the post shall be provided with suitable size stiffner pieces.The post is to be painted with two coats of best quality industrial epoxy paint of approved colour over two coats of industrial epoxy primer . Muffing to be plastered using cement mortar 1:4, 12mm thick colour washing 2 coats using approved colour etc. complete.All GI pipe sections to be used for the fabrication of the post shall be of TATA/ZENITH/APOLLO make.All steel items shall be dip galvanised.
Conveyance, installation, testing and commissioning of departmentally supplied flood light luminaire with lamp on the existing tubular post of height upto 8m from ground level.
Wiring for light point/ fan point/ exhaust fan/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required(Group C)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required .25 mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 X 4.0 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 5 X 4 sq. mm
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supply and fixing brass batten / angle holder including connection etc as required
Supply and fixing 7/9 W LED lamp OSRAM / Philips or equivalent
Supplying 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 840 T8 API Philips or equivalent
Supplying LED luminaire Philips WT 201 C LED 20S - 6500 PSU L 120 IP 65 or equivalent
Supply of SID or equivalent make Street light luminaire, 20W LED, IP66 optical & control gear compartment, die cast aluminium painted housing,anti UV Polycarbonate protector with in built lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy > 105 Lumen/W at Ta 25⁰C. Lifetime residual flux @ Tq 35⁰C @ 50,000 hours = 70%, Ta = 50⁰C, in built surge protection of 4kV (in Differential and Common mode), Power Factor > 0.95, Colour Rendering Index > 70 and Cool white light (5700⁰K).
Supplying modular family street light luminaire KESElec City or equivalent 40W CW LED,an IP66 LEdSafe® optical compartment,a separate IP66 control gear compartment and extruded aluminium painted housing, a toughened glass protector,permanently sealed with a robotically dispensed silicone sealant,closed at one end by an end cover and the other end by a frame and door assembly (to access control gear) both made of injection moulded polycarbonate,a removable control gear plate,safety plug and socket system,high pressure die cast aluminium painted mounting spigot suitable for horizontal mounting (Ø32-42mm) with tilt flexibility of ± 10 degrees, with lensoFlex2® technology,PMMA lenses with wide photometry for increased pole spacing,System efficacy= >90 lumen/watt, Driver efficiency >= 85%, K 07 impact resistance , driver operating voltage 140 V to 277 V, lifetime residual flux @ Tq 35º @50,0000 hours =70%,Ta = 55º,surge protection of 10Kv ( in differential and common mode),Power factor ≥0.90,colour rendering index≥70 and neutral white light (4,100ºK- 5600ºK).
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for LED Lamps including connection etc as required.
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required
Supply, fabrication, conveyance and fixing 40 mm dia B class GI pipe bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
Supply of single phase , 230V ,50W,1400 rpm, 300 mm sweep heavy duty exhaust fan ( Almonard or equivalent) in metal frame Category B ,
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Supplying, fabricating , erecting and commissioning floor mounting, fully compartmentalised, dust and vermin proof cubicle MAIN panel board of size 1250 x 1450 x 250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality epoxy paint over two coats of epoxy primer, having one vertical bus bar chamber, three vertical and one horizontal cable alley having front openable bolting type cover with cable entry provisions, bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom. The panel should have 75x40x6mm MS channel provided at the bottom as support and comprising the following. Incomer:- 125 A, 4 pole,415V, AC 23A duty on-load Change Over Switch with handle, Incoming:- 125A, 35kA FP MCCB setted to 100A and rotory drive kit including BUC handle and shunt release with auxiliary contact- 1No, Outgoings:- 63 AFP MCCB 25 KA setted to 50A - 2Nos with rotary handle , 40 A FP MCCB 16 KA setted to 32A - 1No with rotary handle and 32 A two way All switches and MCCB should be of panel mounting and conforming to IS:13947part III (L&T/SIEMENS/Legrand) disconnectable type neutral link suitably connected, 40 A TP MCCB 16 KA setted to 32A - 2Nos with rotary handle and 32 A two way disconnectable type neutral link suitably connected, Busbar Chamber: Busbar chamber with 38X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming and is also to be carried out using 25x3mm PVC insulated Copper strips supported using epoxy insulators and outgoing with suitable rated copper conductor as required. Protection :- ELR with CBCT current setting 0.03A to 1A with time setting - 1 No Din Rail Surge Protection Device (3+1) Class B&C/ Type 1&2 Tested as per IEC 61643 Part 11:2016 . Total Impulse current-75 (L-N)/100 (N-PE)kA (10/350µ sec) & Total Max Discharge current 195 (L-N)/ 130 (N-PE)kA (8/20µ sec), Voltage protection level <1.5 kV. The Surge Protection Devices should have TOV withstand for 120 Min : 442 V(L-N)& TOV withstand for 200 msec: 1200V (N-PE) . with out Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT & the Protection Modes for : L & N to PE . Short- Circuit Current rating (Isccr) – 50 kA/50 Hz . Back up fuse required more than 315AgG/gL. Health Status Indication required in all cartridge. Total Response time <200 nano sec . Make : Raycap / Erico / Weidmuller.Interconnection with dedicated MCCB with suitably rated copper conductor with copper terminals. Metering and Indication:- Panel surface mounting 96 Sq.mm,LED Multi-function meter with three line display to read V,A,,kVA,kVAr,PF & F with RS485 communication port of make SCHNEIDER or equivalent suitable for 415V,50Hz- 2No,RS 485 to ethernet converter-1 No, SMP power supply- 1 No, 100/5 A Tape wound CT 3 Nos , and 2A SP MCB C Curve -9Nos ,Phase indication lamp - 3 Nos 63A two way disconnectable type neutral link inside the cubicle. The panel board should have hinged shutters and quarterturn key lock for OLCOS/ MCCB cubicles,meterchamber and front openable bolted type busbar covers,cablechamber and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 38x3 mm copper strip with two earthing points at bottom side. (Panel drawing attached with the schedule)
Supplying, fabricating , erecting and commissioning floor mounting, fully compartmentalised, dust and vermin proof cubicle panel board of size 1400 x 1750 x 250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality epoxy paint over two coats of epoxy primer, having one vertical bus bar chamber, three vertical and one horizontal cable alley having front openable bolting type cover with cable entry provisions, bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom. The panel should have 75x40x6mm MS channel provided at the bottom as support and comprising the following. Incomer:- 63 A, AC 23-A, 4 pole on-load Change Over Switch in open Execution--1 Number., Incoming:- 63A, 25kA FP MCCB setted to 50A and rotory drive kit including BUC handle and shunt trip coil - 1 No, Outgoings:- 40 A FP MCCB 25 KA - 2Nos with rotary handle., 25 A TP MCCB 16 KA setted to 20A - 4Nos with rotary handle and 32 A two way disconnectable type neutral link suitably connected.,All switches and MCCB should be of panel mounting,Ics= 100% Icu and conforming to IS:13947part III (L&T/SIEMENS/Legrand), Busbar Chamber: Busbar chamber with 25X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming and is also to be carried out using 25x3mm PVC insulated Copper strips supported using epoxy insulators and outgoing with suitable rated copper conductor as required. Protection :- ELR with CBCT , 3 Phase 4 wire Under & Overvoltage relay (Auto/ manual reset ,Trip time and Power on delay 1 - 10 sec) OV / UV - adjustable and Reverse phase sequence relay and phase sequence relay ,2 NO+2 NC Auxiliary relay with 230 V Ac coil including giving interconnection with suitably rated PVC insulated copper wire with terminals. Metering and Indication:-Panel surface mounting 96 Sq.mm LED Multi-function meter withRS 485 Communication port three line display to read V,A,,kVA,kVAr,PF and frequency of make SCHNEIDER or equivalent suitable for 415V,50Hz- 2Nos, 60/5 A Tape wound CT 3 Nos , and 2A SP MCB C Curve (Cat B)-7Nos and a 63A two way disconnectable type neutral link inside the cubicle. The panel board shall have hinged shutters with quarter turn type lock and key arrangement for OLCOS/ MCCB cubicles and front openable bolted type busbar covers and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 25x3 mm copper strip with two earthing points at bottom side. (Panel drawing attached with the schedule)
Supply, conveyance and fixing 40 A-50A, 25 kA (Ics=100%Icu), 3 pole, MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL & SC conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required
Supply and fixing IP 65 outdoor installation CAPE 9 module( Model No Aki 09) 200x200x122mm Thermoplastic polycarbonate MCB distribution board with PE + N Terminals on the surface using suitable size stainless steel screws.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, 25A residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40A, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing four pole, 415 volts, 40A isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing 0.3 m , 20 mm X 3 mm copper strip on surface or in recess for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq.mm and Upto 95 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle).
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq.mm and Upto 95 sq. mm (clamped with 25x3 mm Flat clamp)
Supply of 4 core 6 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 4 core 4.0 sq mm PVC insulated and PVC sheathed armoured copper Power cable
Supply of 4 core 10 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 4 core 16 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 4 core 25 sq mm PVC insulated and PVC sheathed armoured aluminium cable
Supply of 4 core 50 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 3 core 2.5 sq mm PVC insulated and PVC sheathed submersible copper cable
Supply of 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper Power cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. up to 4C x 10 sq.mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C X 25 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C X 50 sq. mm (35mm)
Supplying and making end termination nickel plated single compression brass cable gland for 4 core 4 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Supplying and making end termination nickel plated single compression brass cable gland for 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Supply of 50/38mm (OD/ID) Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to under ground power/communication/ OFC / Signal cable conforming to IS 14930 Part - II,
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metre.
Providing and fixing10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 8 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and laying bare earthing copper conductor 8 SWG laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in Ordinary soil).
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Supply and fixing Thermoplastic polycarbonate Cable Junction Boxes IP 65 for outdoor applications ( with knock outs for cable entry )) suitable for cable sizes 16 sq.mm ,182 X 180 X 111 mm CAPE model No TKPC1818 -11m withTerminals or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required.
Supply and installation of wall mounting cubicle type dust and vermin proof CAPE make CA63a , 540x270x205mm IP66,IK 10 Glass fibre reinforced polyester enclosure including supply and fixing 63A , 25kA FP MCCB, with rotary handle, 3 Nos phase indication lamp and 3 Nos 2A SP MCB including wiring using 2.5 sq.mm wire for control wiring .
Supplying and fixing surface/ recess mounting, vertical type, 415 volts,Dust and waterproof ,IP66 Hensel make or equivalent FPVN 0412 opaque door 4 way 4 + 12 VTPN distribution board of poly carbonate inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision for MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) as required .
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supply and fixing cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi2410 Hensel make thermoplastic box fixing the following items, including giving connection using 2.5 sq.mmpvc insulated copper wire ,drilling necessary holes for termination as well as entry and exit of cable,terminating the earthwire in the earthstrip etc complete.All the bolt nut & washer shall be brass. Legend Plate Danger,415V ,100x75mm - 1No16mm dia LED type Phase indication lamp and motor ON & Trip indication (Red ,Yellow & Green),MPR 302 BE 040 L&T make motor protection Relay with inbuilt earth fault protection - 1 Nos,32A two way disconnectable type neutral link-1 Nos,20A 415V AC ELMEX Connecter DIN Rail - 5 Nos,Tri[ple Pole Motor Protection Circuit Breaker for 3 HP motor 6.3 A rating Instantaneous Tripcurrent 82 A -1 Nos, 3 phase,415V, 1 KVAR, ISI marked heavy duty Power factor improvement Capacitor with test certificate
Supply and fixing cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi2410 Hensel make thermoplastic box fixing the following items, including giving connection using 2.5 sq.mmpvc insulated copper wire ,drilling necessary holes for termination as well as entry and exit of cable,terminating the earthwire in the earthstrip etc complete.All the bolt nut & washer shall be brass.Legend Plate Danger,415V ,100x75mm - 1No,16mm dia LED type Phase indication lamp and motor ON & Trip indication (Red ,Yellow & Green) ,MPR 301 BE 020 L&T make motor protection Relay with inbuilt earth fault protection - 1 Nos, 32A two way disconnectable type neutral link-1 Nos , 20A 415V AC ELMEX Connecter DIN Rail - 5 Nos, Tri[ple Pole Motor Protection Circuit Breaker for 2 HP motor 4 A rating Instantaneous Tripcurrent 52 A -1 Nos, 3 phase,415V, 1 KVAR, ISI marked heavy duty Power factor improvement Capacitor with test certificate
Supplying metal grilled louvers suitable for 300 mm sweep heavy duty exhaust fan
Supply and fixing IP 65 outdoor glass fibre reinforced polycarbonate CAPE 3 module 100x150x96mm MCB distribution board with PE + N Terminals on the surface using suitable size stainless steel screws.
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
Providing and fixing B class G.I. pipes with ISI mark complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
Supply installation testing and commissioning 50KW/63 KVA, Three phase Diesel Generating Set with CPCBII approved acoustic enclosure comprising of: Cummins / Kirloskar , Radiator Cooled Diesel engine 1500 RPM, complete with standard accessories. Coupled to Stamford / Kirloskar Alternator rated at 50KW/63 KVA at 415 Volts mounted on Channel Iron Base Frame complete with Fuel Tank, Standard manual Control System, residential Silencer and Battery.Leading ,fixing of DG Set on foundation,allgining,setting ,tesing ,commissioning of DG Set at available load, including HS Diesel for 1 Hr, First Fill of Diesel, preparing documentation, arranging inspection and getting approval from Electrical Inspectorate including statutory fees (Fees applicable only for the DG set) to KSEB/Electrical Inspectorate.
Making thermal insulation on exhaust piping (using glass wool & Aluminium cladding)
Making thermal insulation on exhaust piping (using glass wool & Aluminium cladding)
gnarakkal brothers
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_514438.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .