Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 6 573D BHASKARA BUILDING NADAKKAVU P O UDAYAMPEROOR ERNAKULAM KERALA 682307 | ERNAKULAM | KERALA | 682307 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
22 Feb 2022, 6:00 pmClosed
Manager Subcontract
KEL Kochi
ELECTRIFICATION WORKS OF TRANSFORMER PLANT,KEL, MAMALA
2022_KEL_473931_1
KRO/ BDC/1038/2022
Open Tender
Electrical Works
Item Rate
90 days
KEL Kochi
As per NIT
5 documents required · 5 mandatory
₹2,950
₹50,000
Yes
3 Mar 2022
10 Feb 2022
24 Feb 2022
10 Feb 2022
22 Feb 2022
10 Feb 2022
10 Feb 2022 - 22 Feb 2022
Amount
SWITCH BOARD
SB - 1 (Main Panel)
Supply, installation, testing & commissioning of cubicle type
Switch Board Panel suitable for 415 V, 3 Phase, 4 wire,
50 Hz AC supply system having sufficient front surface area
fabricated in compartmentalised design from CRCA sheet
steel of 2mm thick for frame work and covers, 3mm thick
for gland, plates cleaning & finishing complete with 7 tank
process for powder coating in approved shade, having 800
Amps capacity extensible type TPN Aluminum alloy bus
bars of high conductivity, DMC / SMC / FRP bus bar
supports, with short circuit withstand capacity of 31 MVA
for 1 Sec., bottom base channel of MS section not less than
100 mm x 50 mm x 5 mm thick, fabrication shall be done in
transportable sections, entire panel shall have a common
copper earth bar of size 32 mm x 6 mm at the rear with
2 Nos. earth stud, solid connections from main bus bar to
switch gears with required size of AL. bus bars and control
wiring with 1.5 sq. mm. PVC insulated FRLSH copper
conductor cables, cable alleys etc. The panel shall conform
to Electrical Inspectorate standards and it shall only be
manufactured after getting approval from the Electrical
Inspectorate and the consultant.
Busbar
1 Runs of 100 x 12mm AL.Busbar for each Phase
1 Runs of 63 x 12mm AL.Busbar for Neutral
EB Side
1 Nos - 800A 36kA 4P Microprocessor based MCCB with
ROM and Spreader
1 Set - RYB Indication lamps with Control MCBs
3 Nos - 800/5A CL:1, 10VA CT
1 Nos - Digital Multifunction Meter measuring V, A, F,
KWH, KVA, PF with Control MCBs
DG Side
1 Nos - 400A 36kA 4P Microprocessor based MCCB with
ROM and Spreader
1 Set RYB Indication lamps with Control MCBs
3 Nos - 400/5A CL:1, 10VA CT
1 Nos - Digital Multifunction Meter measuring V, A, F,
KWH, KVA, PF with Control MCBs
Interlock
Castle Key Interlock - 2 Lock with one Key
Surge Protection Device
2 Nos - 8 Module DIN Rail Mounting Type 1 + Type 2 /
Class 1 + class II 100kA SPD on the incoming side of EB
Supply and DG Supply with all necessary accessories etc.
complete as required. The connections to RYB Phases,
Neutral and Earth shall be done using 16 Sq.mm Single Core
Flexible Copper conductor cables with less than 0.45m in
length.
Outgoings
1 Nos - 630A 36kA 4P Microprocessor based MCCB with
ROM, Spreader Digital Multifunction Meter measuring V, A,
F, KWH, KVA, PF with Control MCBs and CTs
3 Nos - 400A 36kA 4P Thermal magnetic type MCCB
having 70 to 100% setting provision with ROM, Spreader,
Digital Multifunction Meter measuring V, A, F, KWH,
KVA, PF with Control MCBs and CTs
2 Nos - 320A 36kA 4P Thermal magnetic type MCCB
having 70 to 100% setting provision with ROM, Spreader,
Digital Multifunction Meter measuring V, A, F, KWH,
KVA, PF with Control MCBs and CTs
2 Nos - 250A 36kA 4P Thermal magnetic type MCCB
having 70 to 100% setting provision with ROM, Spreader,
Digital Multifunction Meter measuring V, A, F, KWH,
KVA, PF with Control MCBs and CTs
SUB SWITCH BOARDS
SSB - 1 (Plant - Right Side)
Supply, installation, testing & commissioning of cubicle type
Sub Switch Board Panel suitable for 415 V, 3 Phase, 4 wire,
50 Hz AC supply system having sufficient front surface area
fabricated in compartmentalised design from CRCA sheet
steel of 2mm thick for frame work and covers, 3mm thick
for gland, plates cleaning & finishing complete with 7 tank
process for powder coating in approved shade, having 400
Amps capacity extensible type TPN Aluminum alloy bus
bars of high conductivity, DMC / SMC / FRP bus bar
supports, with short circuit withstand capacity of 31 MVA
for 1 Sec., bottom base channel of MS section not less than
100 mm x 50 mm x 5 mm thick, fabrication shall be done in
transportable sections, entire panel shall have a common
copper earth bar of size 25 mm x 6 mm at the rear with
2 Nos. earth stud, solid connections from main bus bar to
switch gears with required size of AL. bus bars and control
wiring with 1.5 sq. mm. PVC insulated FRLSH copper
conductor cables, cable alleys etc. The panel shall conform
to Electrical Inspectorate standards and it shall only be
manufactured after getting approval from the Electrical
Inspectorate and the consultant.
Busbar
1 Runs of 63 x 10mm AL.Busbar for each Phase
1 Runs of 40 x 10mm AL.Busbar for Neutral
Incomer
1 No - 400A, 36kA 4P Thermal Magnetic type MCCB
having 70 to 100% setting provision with ROM, Spreader &
Stunt Release
1 Set - RYB Indication lamps with Control MCBs
3 Nos - 400/5A CL:1, 10VA CT
1 Nos - Digital Multifunction Meter measuring V, A, F,
KWH, KVA, PF with Control MCBs
1 Nos - Earth Leakage Relay with CBCT
Outgoings
1 Nos - 200A 25kA 4P Thermal magnetic type MCCB
having 70 to 100% setting provision with ROM & spreaders
2 Nos - 160A 25kA 4P Thermal magnetic type MCCB with
having 70 to 100% setting provision with ROM & spreaders
2 Nos - 125A 25kA 4P Thermal magnetic type MCCB with
having 70 to 100% setting provision with ROM & spreaders
3 Nos - 100A 25kA 4P Thermal magnetic type MCCB with
having 70 to 100% setting provision with ROM & spreaders
1 Nos - 80A 25kA 4P Thermal magnetic type MCCB with
having 70 to 100% setting provision with ROM & spreaders
SSB - 2 (Plant - Left Side)
Supply, installation, testing & commissioning of cubicle type
Sub Switch Board Panel suitable for 415 V, 3 Phase, 4 wire,
50 Hz AC supply system having sufficient front surface area
fabricated in compartmentalised design from CRCA sheet
steel of 2mm thick for frame work and covers, 3mm thick
for gland, plates cleaning & finishing complete with 7 tank
process for powder coating in approved shade, having 400
Amps capacity extensible type TPN Aluminum alloy bus
bars of high conductivity, DMC / SMC / FRP bus bar
supports, with short circuit withstand capacity of 31 MVA
for 1 Sec., bottom base channel of MS section not less than
100 mm x 50 mm x 5 mm thick, fabrication shall be done in
transportable sections, entire panel shall have a common
copper earth bar of size 25 mm x 6 mm at the rear with
2 Nos. earth stud, solid connections from main bus bar to
switch gears with required size of AL. bus bars and control
wiring with 1.5 sq. mm. PVC insulated FRLSH copper
conductor cables, cable alleys etc. The panel shall conform
to Electrical Inspectorate standards and it shall only be
manufactured after getting approval from the Electrical
Inspectorate and the consultant.
Busbar
1 Runs of 63 x 10mm AL.Busbar for each Phase
1 Runs of 40 x 10mm AL.Busbar for Neutral
Incomer
1 No - 400A, 36kA 4P Thermal Magnetic type MCCB
having 70 to 100% setting provision with ROM, Spreader &
Stunt Release
1 Set - RYB Indication lamps with Control MCBs
3 Nos - 400/5A CL:1, 10VA CT
1 Nos - Digital Multifunction Meter measuring V, A, F,
KW, KVA, PF with Control MCBs
1 Nos - Earth Leakage Relay with CBCT
Outgoings
1 Nos - 200A 25kA 4P Thermal magnetic type MCCB
having 70 to 100% setting provision with ROM & spreaders
2 Nos - 160A 25kA 4P Thermal magnetic type MCCB with
having 70 to 100% setting provision with ROM & spreaders
2 Nos - 125A 25kA 4P Thermal magnetic type MCCB with
having 70 to 100% setting provision with ROM & spreaders
3 Nos - 100A 25kA 4P Thermal magnetic type MCCB with
having 70 to 100% setting provision with ROM & spreaders
1 Nos - 80A 25kA 4P Thermal magnetic type MCCB with
having 70 to 100% setting provision with ROM & spreaders
SSB - 3 (Testing)
Supply, installation, testing & commissioning of cubicle type
Sub Switch Board Panel suitable for 415 V, 3 Phase, 4 wire,
50 Hz AC supply system having sufficient front surface area
fabricated in compartmentalised design from CRCA sheet
steel of 2mm thick for frame work and covers, 3mm thick
for gland, plates cleaning & finishing complete with 7 tank
process for powder coating in approved shade, having 630
Amps capacity extensible type TPN Aluminum alloy bus
bars of high conductivity, DMC / SMC / FRP bus bar
supports, with short circuit withstand capacity of 31 MVA
for 1 Sec., bottom base channel of MS section not less than
100 mm x 50 mm x 5 mm thick, fabrication shall be done in
transportable sections, entire panel shall have a common
copper earth bar of size 25 mm x 6 mm at the rear with
2 Nos. earth stud, solid connections from main bus bar to
switch gears with required size of AL. bus bars and control
wiring with 1.5 sq. mm. PVC insulated FRLSH copper
conductor cables, cable alleys etc. The panel shall conform
to Electrical Inspectorate standards and it shall only be
manufactured after getting approval from the Electrical
Inspectorate and the consultant.
Busbar
1 Runs of 75 x 12mm AL.Busbar for each Phase
1 Runs of 50 x 12mm AL.Busbar for Neutral
Incomer
1 Nos - 630A 36kA 4P Microprocessor based MCCB with
ROM, Spreader & Shunt Release
1 Set - RYB Indication lamps with Control MCBs
3 Nos - 630/5A CL:1, 10VA CT
1 Nos - Digital Multifunction Meter measuring V, A, F,
KW, KVA, PF with Control MCBs
1 Nos - Earth Leakage Relay with CBCT
Outgoings
1 Nos - 400A 25kA 4P Thermal magnetic type MCCB
having 70 to 100% setting provision with ROM & spreaders
1 Nos - 200A 25kA 4P Thermal magnetic type MCCB
having 70 to 100% setting provision with ROM & spreaders
1 Nos - 160A 25kA 4P Thermal magnetic type MCCB with
having 70 to 100% setting provision with ROM & spreaders
2 Nos - 125A 25kA 4P Thermal magnetic type MCCB with
having 70 to 100% setting provision with ROM & spreaders
3 Nos - 100A 25kA 4P Thermal magnetic type MCCB with
having 70 to 100% setting provision with ROM & spreaders
SSB - 4 (Lighting)
Supply, installation, testing & commissioning of cubicle type
Sub Switch Board Panel suitable for 415 V, 3 Phase, 4 wire,
50 Hz AC supply system having sufficient front surface area
fabricated in compartmentalised design from CRCA sheet
steel of 2mm thick for frame work and covers, 3mm thick
for gland, plates cleaning & finishing complete with 7 tank
process for powder coating in approved shade, having 250
Amps capacity extensible type TPN Aluminum alloy bus
bars of high conductivity, DMC / SMC / FRP bus bar
supports, with short circuit withstand capacity of 31 MVA
for 1 Sec., bottom base channel of MS section not less than
100 mm x 50 mm x 5 mm thick, fabrication shall be done in
transportable sections, entire panel shall have a common
copper earth bar of size 25 mm x 6 mm at the rear with
2 Nos. earth stud, solid connections from main bus bar to
switch gears with required size of AL. bus bars and control
wiring with 1.5 sq. mm. PVC insulated FRLSH copper
conductor cables, cable alleys etc. The panel shall conform
to Electrical Inspectorate standards and it shall only be
manufactured after getting approval from the Electrical
Inspectorate and the consultant.
Metering
4 Nos - Busbar Provision for fixing CTs
1 Nos - Provision for fixing Three Phase Energy Meter
Fuse & Neutral Link
3 Nos - 250A Bakelite/Open Type Fuse with HRC Fuse of
Suitable Rating
1 Nos - 250A Neutral Link
Busbar
1 Runs of 50 x 10mm AL.Busbar for each Phase
1 Runs of 32 x 10mm AL.Busbar for Neutral
Incomer
1 Nos - 250A 25kA 4P Thermal magnetic type MCCB
having 70 to 100% setting provision with ROM, Spreader &
Shunt Release
1 Set - RYB Indication lamps with Control MCBs
3 Nos - 250/5A CL:1, 10VA CT
1 Nos - Digital Multifunction Meter measuring V, A, F,
KW, KVA, PF with Control MCBs
1 Nos - Earth Leakage Relay with CBCT
Outgoings
1 Nos - 125A 36kA 4P Thermal magnetic type MCCB
having 70 to 100% setting provision with ROM, Spreader,
Digital Multifunction Meter measuring V, A, F, KWH,
KVA, PF with Control MCBs and CTs
3 Nos - 100A 36kA 4P Thermal magnetic type MCCB
having 70 to 100% setting provision with ROM, Spreader,
Digital Multifunction Meter measuring V, A, F, KWH,
KVA, PF with Control MCBs and CTs
3 Nos - 80A 36kA 4P Thermal magnetic type MCCB
having 70 to 100% setting provision with ROM, Spreader,
Digital Multifunction Meter measuring V, A, F, KWH,
KVA, PF with Control MCBs and CTs
2 Nos - Street Light Cubicle with 40A 30mA 4P RCCB,
40A 4P MCB, 40A 3P Contactor, 24Hour Timer Switch,
Push buttons, ON (Green) - OFF (Red) Indication lamps
with Control MCBs, etc.complete as required with Digital
Multifunction Meter measuring V, A, F, KWH, KVA, PF
with Control MCBs and CTs
DISTRIBUTION BOARD
Supply and fixing of following ways surface / recess
mounting, vertical type, 415 V, TPN MCCB distribution
board of sheet steel, dust protected, duly powder coated,
inclusive of 200A tinned copper bus bar, common neutral
link, earth bar, din bar for mounting MCBs (But without
MCBs (But without MCBs and incomer) as required.
8 Way , Double Door
6 Way , Double Door
Supply and fixing of following ways surface / recess
mounting, vertical type, 415 V, TPN MCB distribution board
of sheet steel, dust protected, duly powder coated, inclusive
of 200A tinned copper bus bar, common neutral link,
earth bar, din bar for mounting MCBs (But without MCBs
and incomer) as required.
8 Way (8 + 24), Double Door
6 Way (8 + 18), Double Door
4 Way (8 + 12), Double Door
Supply and fixing of following way, horizontal type three
pole and neutral, sheet steel, MCB distribution board, 415V,
on surface/recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder
coated including earthing as required. (But without MCB/
RCCB/Isolator)
8 Way (8 + 24), Double Door
6 Way (8 + 18), Double Door
4 Way (8 + 12), Double Door
Supply and fixing of following way, single pole and neutral,
sheet steel, MCB distribution board, 240V, on surface /
recess, complete with tinned copper bus bar, neutral bus
bar, earth bar, din bar, interconnections, powder coated
including earthing etc. as required. (But without MCB/RCCB
/Isolator)
16 Way, Double Door
Supply and fixing following rating and breaking capacity and
pole MCCB with thermal magnetic release having 70 to 100%
setting provision and terminal spreaders in the distribution
board including making connections, etc. complete as
required.
80A to 100A 25kA 4P MCCB
Supply and fixing following rating, four pole, (three phase
and neutral), 415V, Residual Current Circuit Breaker
(RCCB), having a sensitivity current 30 mA in the existing
MCB DB complete with connections, testing and
commissioning etc. as required.
Supply and fixing following rating, double pole, (single
phase and neutral),240V, Residual Current Circuit Breaker
(RCCB), having a sensitivity current 30 mA in the existing
MCB DB complete with connections, testing and
commissioning etc. as required.
Supply and fixing 5A to 32A rating, 240/415V, 10kA, "C "
Curve, miniature circuit breaker suitable for inductive load
of following poles in the existing MCB DB complete with
connections, testing and commissioning etc as required.
Single Pole
Double Pole
Triple Pole
40A to 63A Triple Pole
MCB DUMMY
Supply and fixing single pole blanking plate in the existing
MCB DB complete etc. as required.
ISOLATOR
Supply and fixing following rating, four pole, 415V,
isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
100A 4P Isolator
63A 4P Isolator
40A 4P Isolator
25A 4P Isolator
Supply and fixing following rating, double pole, 240V,
isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
63A 2P Isolator
40A 2P Isolator
METAL ENCLOSURE
Supply and fixing Sheet Steel enclosure on surface / recess
having provision to fix MCB/Isolator complete with
connections, testing and commmissioning etc. as required.
INDUSTRIAL SOCKET
Supply and fixing 32A, 415V, TPN Industrial type socket
outlet, with 4 pole and earth, metal enclosed plug top along
with 30A/32A, 'C Curve', TP MCB, in sheet steel enclosure,
on surface or in recess, with chained metal cover for the
socket outlet and complete with connections, testing and
commissioning etc. as required.
Supply and fixing 20A, 240V, SPN Industrial type socket
outlet, with 2 pole and earth, metal enclosed plug top along
with 20A, 'C Curve', SP MCB, in metal sheet enclosure, on
surface or in recess, with chained metal cover for the
socket outlet and complete with connections, testing and
commissioning etc. as required.
DOL STARTER
Supplying, installation, testing & commissioning of DOL
Starter Switch Panel enclosure suitable for 5HP to 10HP
compressor complete with all accessories including 4P
Power Contactor, Overload Relay, ON-OFF Push Buttons,
etc. complete with wiring in duly powder coated sheet steel
enclosure.
LT CABLES
Supply, laying, testing and commissioning of PVC 1.1 KV
grade XLPE insulated armoured Aluminium cables of the
following sizes and laying in earth excavated trenches,
clamping in built up trenches, trays, racks, risers, trusses,
walls etc using heavy duty Aluminium Flat or heavy duty GI
spacer saddles of which spacing of clamps not exceeding
40cm and pulling through pipes including all minor civil
works.
3.5C x 400 Sq.mm Al. cable
3.5C x 300 Sq.mm Al. cable
3.5C x 240 Sq.mm Al. cable
3.5C x 185 Sq.mm Al. cable
3.5C x 150 Sq.mm Al. cable
3.5C x 120 Sq.mm Al. cable
3.5C x 95 Sq.mm Al. cable
3.5C x 70 Sq.mm Al. cable
3.5C x 50 Sq.mm Al. cable
3.5C x 35 Sq.mm Al. cable
4C x 25 Sq.mm Al. cable
4C x 16 Sq.mm Al. cable
4C x 10 Sq.mm Al. cable
4C x 6 Sq.mm Al. cable
2C x 10 Sq.mm Al. cable
2C x 6 Sq.mm Al. cable
4C x 2.5sq.mm Copper Armoured cable
2C x 2.5sq.mm Copper Armoured cable
4C x 1.5sq.mm Copper Armoured cable
2C x 1.5sq.mm Copper Armoured cable
GLANDING AND TERMINATION
Supply and making end termination with brass compression
gland and alluminium lugs for following size of PVC
insulated and PVC sheathed/ XLPE Aluminium conductor
cable of 1.1 KV grade as required.
3.5C x 400 Sq.mm Al. cable
3.5C x 300 Sq.mm Al. cable
3.5C x 240 Sq.mm Al. cable
3.5C x 185 Sq.mm Al. cable
3.5C x 150 Sq.mm Al. cable
3.5C x 120 Sq.mm Al. cable
3.5C x 95 Sq.mm Al. cable
3.5C x 70 Sq.mm Al. cable
3.5C x 50 Sq.mm Al. cable
3.5C x 35 Sq.mm Al. cable
4C x 25 Sq.mm Al. cable
4C x 16 Sq.mm Al. cable
4C x 10 Sq.mm Al. cable
4C x 6 Sq.mm Al. cable
2C x 10 Sq.mm Al. cable
2C x 6 Sq.mm Al. cable
4C x 2.5sq.mm Copper Armoured cable
2C x 2.5sq.mm Copper Armoured cable
4C x 1.5sq.mm Copper Armoured cable
2C x 1.5sq.mm Copper Armoured cable
GLAND EARTHING
Supply and providing gland earthing using Aluminium or
Copper strip / shim / wire using copper sockets etc.
complete as required conforming to Electrical Inspectorate
Standards.
3.5C x 400 Sq.mm Al. cable
3.5C x 300 Sq.mm Al. cable
3.5C x 240 Sq.mm Al. cable
3.5C x 185 Sq.mm Al. cable
3.5C x 150 Sq.mm Al. cable
3.5C x 120 Sq.mm Al. cable
3.5C x 95 Sq.mm Al. cable
3.5C x 70 Sq.mm Al. cable
3.5C x 50 Sq.mm Al. cable
3.5C x 35 Sq.mm Al. cable
4C x 25 Sq.mm Al. cable
4C x 16 Sq.mm Al. cable
4C x 10 Sq.mm Al. cable
4C x 6 Sq.mm Al. cable
2C x 10 Sq.mm Al. cable
2C x 6 Sq.mm Al. cable
4C x 2.5sq.mm Copper Armoured cable
2C x 2.5sq.mm Copper Armoured cable
4C x 1.5sq.mm Copper Armoured cable
2C x 1.5sq.mm Copper Armoured cable
LT CABLE JOINT
Supplying and making straight through joint with heat
shrinkable kit including ferrules and other jointing materials
for the following size of PVC insulated and PVC sheathed /
XLPE aluminium conductor cable of 1.1KV grade as
required.
3.5C x 400 Sq.mm
3.5C x 95 Sq.mm
EARTHING
Supply and providing earthing with CI earth plate 1200mm x
1200mm x 12.6mm thick electrode including accessories,
and providing masonary enclosure with cover plate having
locking arrangement and watering pipe of 2.7 meter long
etc. with charcoal/coke and salt as required conforming to
relevant IS and Electrical Inspectorate standards etc.
Supply and providing earthing with CI earth plate 600mm x
600mm x 6mm thick electrode including accessories,
and providing masonary enclosure with cover plate having
locking arrangement and watering pipe of 2.7 meter long
etc. with charcoal/coke and salt as required conforming to
relevant IS and Electrical Inspectorate standards etc.
EARTHING CONDUCTORS
Supply and providing the earth conductors of the following
sizes and laying in earth excavated trenches, clamping in
built up trenches , walls, trays, racks, risers, trusses, etc
using heavy duty Aluminium Flat or heavy duty GI spacer
saddles of which spacing of clamps not exceeding 90cm
without making holes in the earthing conductor and pulling
through pipes including all minor civil works. All the joints
should be properly tinned and connections should only be
done using SS Nut and Bolts with double washers etc as
required.
25 x 6 mm Copper Strip
25 x 3 mm Copper Strip
8 SWG Copper Wire
10 SWG Copper Wire
MS STRUCTURALS
Supply, fabrication and installation of cable tray and supports
using M.S angles and plates of adequate size painted with
one coat of Zinc chromate primer and two coats of black
enamel paint.
Supply, fabrication and installation of Panel Board mounting
supports using C Channels of adequate size painted with two
two coat of Zinc chromate primer and two coats of black
enamel paint.
Supply, fabrication and installation of checkered plates of
6mm thickness to use above the cable trenches duly
supported with channels and duly painted with two coat of
Zinc chromate primer and two coats of black enamel paint.
and as required.
PIPES FOR CABLE PROTECTION
Supply and laying of the following size medium class GI
pipe in ground/wall/ceiling complete with fittings.
50mm dia
80mm dia
100mm dia
150mm dia
Supply and laying of the following size DWC HDPE pipe
ISI marked along with all accessories like socket, bend,
couplers etc. conforming to IS 14930, Part II complete
with fitting and cutting, jointing etc. in the existing trench,
complete as required.
63mm dia
90mm dia
120mm dia
160mm dia
200mm dia
POINT WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed medium
class PVC conduit, with modular switch, modular plate,
suitable GI box / surface box and earthing the point with
1.5 sq.mm FRLS PVC insulated copper conductor single
core cable etc. as required.
Group C
Wiring for twin control light point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable in surface
/recessed medium class PVC conduit, 2 way modular
switch, modular plate, suitable GI box / PVC surface box
and earthing point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point / fan point /
exhaust fan point / call bell point (without independent
switch etc.) with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed medium
PVC conduit, and earthing the point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable etc. as
required.
Group C
Supply and fixing two module stepped type electronic fan
regulator on the existing modular plate switch box including
connections but excluding modular plate etc. as required.
Supply and fixing suitable size GI box /PVC surface box
with modular plate and cover in front on surface or in
recess including providing and fixing 3 pin 5/6 A modular
socket outlet and 5/6 A modular switch, connections etc. as
required.
Supply and fixing suitable size GI box /PVC surface box
with modular plate and cover in front on surface or in
recess including providing and fixing 2 Nos. 3 pin 5/6 A
modular socket outlet and 2 Nos of 5/6 A modular switch,
connections etc. as required. (For light plugs to be used in
non residential buildings).
Supply and fixing suitable size GI box /PVC surface box
with modular plate and cover in front on surface or in
recess including providing and fixing 3 Nos. 3 pin 5/6 A
modular socket outlet and 2 Nos of 5/6 A modular switch,
connections etc. as required. (For light plugs to be used in
non residential buildings).
Supply and fixing suitable size GI box / PVC surface
box with modular plate and cover in front on surface or in
recess, including providing and fixing 6 pin 5/6 & 15/16 A
modular socket outlet and 15/16 A modular switch,
connections etc. as required
Supply and fixing suitable size GI box / PVC surface
box with modular plate and cover in front on surface or in
recess, including providing and fixing 2 Nos of 6 pin 5/6 &
15/16 A modular socket outlet and 15/16 A modular switch,
connections etc. as required
Supply and fixing following size/ modules, GI box / PVC
surface box along with modular base and cover plate for
modular switches in surface or in recess etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
12 Module
Supply and fixing following modular switch/socket on the
existing modular plate and switch box including connections
etc. as required.
Telephone socket outlet
TV antenna socket outlet
Data socket outlet
Supply and fixing 3 pin, 5A ceiling rose on the existing
junction box/wooden block including connections etc. as
required
Supply and fixing modular blanking plate on the existing
modular plate & switch box excluding modular plate as
required.
CIRCUIT WIRING
Wiring for circuit / submain wiring along with earth wire
with the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface / recessed medium
class PVC conduit as required.
2 x 1.5 sqmm + 1 x 1.5 sq.mm earth wire
2 x 2.5 sqmm + 1 x 2.5 sq.mm earth wire
2 x 4.0 sqmm + 1 x 4.0 sq.mm earth wire
2 x 6.0 sqmm + 1 x 6.0 sq.mm earth wire
4 x 6.0 sqmm + 2 x 6.0 sq.mm earth wire
4 x 10.0 sqmm + 2 x 6.0 sq.mm earth wire
TELEPHONE, TV & DATA WIRING
Supply and drawing following pair 0.5mm dia FRLS PVC
insulated annealed copper conductor, unarmoured telephone
cable in the existing surface/recessed PVC conduit as
required.
Supply and drawing co-axial TV cable RG-6 grade, 0.7mm
solid copper conductor PE insulated, shielded with fine
tinned copper braid and protected with PVC sheath in the
existing surface/recessed PVC conduit as required.
Supply and drawing of UTP 4 pair CAT 6 LAN Cable in the
existing surafce/recessed PVC conduit as required.
1 run of cable
SUPPLY AND LAYING OF CONDUITS
Supply and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of
recessed conduit as required.
STREET LIGHTING
Supply, installation, testing & commissioning of 9 meter high
hot dip galvanised Octagonal poles with double arm bracket,
155mm bottom dia and 70mm top dia made up of 3mm thick
sheet along with base plate of size 250 x 250 x 16mm.
Supply, installation, testing & commissioning of 8 meter high
hot dip galvanised Octagonal poles with double arm bracket,
130mm bottom dia and 70mm top dia made up of 3mm thick
sheet along with base plate of size 200 x 200 x 16mm.
Supply, installation, testing & commissioning of 7 meter high
hot dip galvanised Octagonal poles with double arm bracket,
130mm bottom dia and 70mm top dia made up of 3mm thick
sheet along with base plate of size 200 x 200 x 12mm.
Supply, installation, testing & commissioning of the following
Watts Graphite grey powder coated pressure die-cast
aluminium housing with weatherproof gasket for LEDs and
control gear compartments, pressure die-cast aluminium
frame with heat resistant toughened clear glass fixed with
SS screws. LEDs shall provided with secondary lens optics
to get optimum optical performance. The drivers used shall
be specially designed to have built-in surge voltage, open /
short circuit protections.Internal surge of 5 KV and External
surge protection of 10 KV provided for additional safety.
Luminaire shall have CCT of 5700, CRI >70, IP 66
protection, IK 07, PF>.95, THD <10%,operating voltage
range of 150 - 300v AC, and 120 Lumesn/watt efficiency
with a lumen package of 12000
Foundation
Providing required RCC foundation for Street Light Pole
after excavating of the soil to the required depth. The
concrete mix for PCC shall be in M:15 Grade (1:2:4) and
that of RCC shall be in M:20 Grade (1:1.5:3). The contractor
shall submit the drawings of the foundation to the Engineer/
Manager in charge and Consultant for getting approval
before the commencement of work or the work shall be
executed as per the drawings given to the contractor.
SUPPLY OF LIGHT & OTHER FITTINGS
Supply and providing the following fittings and items at site
Battern/Angle Holder
LED Bulb (up to 12W)
Industrial type LED Tube Set of 1 x 20W with Tube
Industrial type LED Tube Set of 2 x 20W with Tube
2 x 2 (2 Feet x 2 Feet) LED Light
120W LED Highbay Light
100W LED Flood Light
50W LED Flood Light
26W/28W BLDC Ceiling Fan of Sweep 1200mm with
Remote
High Speed Metal Type Exhaust Fan of Sweep 225mm
High Speed Shutter Type Exhaust Fan of Sweep 200mm
High Speed Shutter Type Exhaust Fan of Sweep 150mm
INSTALLATION OF LIGHT & OTHER FITTINGS
Installation, testing and commissioning of PVC battern /
angle holder fitting complete with all accessories directly on
ceiling/wall, including giving connections etc. as required.
Installation, testing and commissioning of pre-wired,
flourescent fitting/compact flourescent fitting of all types
complete with all accessories and tube/lamp etc. directly on
ceiling/wall, including connections with 1.5 sq.mm FRLS
PVC insulated, copper conductor, single core cable and
earthing etc. as required.
Installation, testing and commissioning of 2 x 2 (2 Feet x
2 Feet) LED Ceiling light fittings complete with all
accessories directly on the ceiling by cutting the ceiling
including giving connections etc. as required.
Installation, testing and commissioning of 120W LED
Highbay light fittings complete with all accessories directly
on ceiling, including giving connections etc. as required.
Installation, testing and commissioning of 100W LED Flood
light fittings complete with all accessories directly on wall/
piller/ceiling, including giving connections etc. as required.
Installation, testing and commissioning of 50W LED Flood
light fittings complete with all accessories directly on wall/
piller/ceiling, including giving connections etc. as required.
Installation, testing and commissioning of ceiling fan,
including wiring the down rods of standard length (up to
30cm) with 1.5 sq.mm FRLS PVC insulated, copper .
conductor, single core cable etc. as required
Installation of exhaust fan in the existing opening, including
making good the damage, connection, testing,
commissioning etc. as required.
up to 450mm sweep
FAN ROD
Supply and fixing extra down rod of 10cm legnth G.I pipe
15mm dia, heavy guage including painting etc. as required.
(Note: More than 5cm length shall be rounded to the
nearest 10cm and 5cm or less shall be ignored).
Supply and fixing extra down rod of 20cm legnth G.I pipe
15mm dia, heavy guage including painting etc. as required.
(Note: More than 5cm length shall be rounded to the
nearest 10cm and 5cm or less shall be ignored).
DISMANTLING
Labour charges for the dismantling of existing Main Panel
Board (MSB), tracing the existing cables, disconnecting and
dismantling the existing cables and connections, providing
temporary connection arrangements to existing cables if
necessary etc. complete as required.
Labour charges for the dismantling of existing 105KVAR
APFCR Panel Board, tracing the existing cables,
disconnecting and dismantling the existing cables and
connections, providing temporary connection arrangements
to existing cables if necessary etc. complete as required.
Labour charges for the dismantling of existing Lighting Panel
Board, tracing the existing cables, disconnecting and
dismantling the existing cables and connections, providing
temporary connection arrangements to existing cables if
necessary etc. complete as required.
Labour charges for the dismantling of existing any other
Switch Board/Sub Switch Board Panel, tracing the existing
cables, disconnecting and dismantling the existing cables and
connections, providing temporary connection arrangements
to existing cables if necessary etc. complete as required.
Labour charges for the dismantling of all existing DB's,
Wiring Switch Boards, Ceiling Fans, Wall Fans, Exhaust
Fans, Tube & other Light Fittings, Conduits, Wires, Ceiling
Roses etc. tracing of existing wirings, providing temporary
connection arrangements if necessary etc. complete as
required.
SAFETY EQUIPMENTS
Supply and fixing MV danger notice plate of 200 mm x
150mm, made of mild stee,l at least 2mm thick and vitreous
enameled white on both sides and with inscriptions in signal
red colour on front side as required.
Supply and fixing 2Kg Dry Chemical Powder (DCP) type
fire extinguisher complete with Gun Metal cap, hose with
squeeze grip nozzle, wall fixing brackets conforming to
BIS: 2171 and with ISI mark
Supply and fixing safety instruction chart in word duly
framed in good frame work as required.
Supply and providing a set of 2 Nos. 9.5 Litre capacity GI
bucket painted in post office red colour with prior coat of
red oxide paint and written with white paint "FIRE" and
mounted on MS angle iron frame with bracket of
appropriate size and capacity including filling sand etc.
Supply and providing First Aid Box as approved by St.John
Ambulance Brigade / Indian Red Cross conforming to
Supply and fixing laminated shock treatment chart duly
mounted on a good frame work
Supply and providing electrical grade rubber mat of size
2m x 1m having 12mm thickness in front of panels and
DBs conforming to IS 15652 : 2006 standard.
Supply and providing electrical grade rubber mat of size
2m x 1m having 6mm thickness in front of panels and
DBs conforming to IS 15652 : 2006 standard.
Supply and providing tested industrial safety helmet
conforming to IS 2925 : 1984
NAMING FOR IDENTIFICATION
Painting letters or figures of 2.5cm/4.5cm sizes with enamel
paint as identification mark to Panel boards, DBs etc as
required.
EARTH EXCAVATION AND BACK FILLING
Excavation of all types of soils for the laying of XLPE
insulated power cable, GI / HDPE / RCC Pipes, Earthing
Copper conductors to the required width and depth up to
1.2m and back filling after providing sand cushioning and
protective covering by laying bricks breadth wise above the
cable. The supply of sand and bricks will come within this
scope. The trench dimensions and specifications shall be as
per the Electrical Inspectorate, KSEB & CPWD standards.
Excavation and Back Filling
Supply and laying of Bricks
Supply and filling of sand
DOCUMENTATION
Preparation of drawings and getting approval from Electrical
Inspectorate. (*All Statutory fees shall be remitted by the
Client / Consumer or it shall be reimbursed on the
submission of supporting documents).
Submission of completion report, arranging Inpsection and
obtaining Sanction Order from Electrical Inspectorate .(All
Statutory fees shall be remitted by the Client / Consumer
or it shall be reimbursed on the submission of supporting
documents.).
Excluding GST
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of installation, testing and commissioning cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD/Irrigation Dept. specification and direction of Engineer at site.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
Push Button- L&T, Schneider, Rishabh
Detailed list of brand/make of Electrical items enclosed.
Detailed list of brand/make of Electrical items enclosed.
JOSPOWER CONROLS
YOOSAF K A
BPE BHARATH POWER ENGINEERS PVT LTD
ZEUS ELECTRIC CONTROLS
Shine Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .