| 1 | L1₹35.0 LAccepted-Finance RZ M 21 NAND BLOCK MAHAVIR ENCLAVE PALAM NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹35.0 L | L1 | Accepted-Finance L1 |
| 2 | L2₹35.8 L+₹77,238 (2.20%)Accepted-Finance | ₹35.8 L+₹77,238 (2.20%) | L2 | Accepted-Finance L2 |
| 3 | L3₹36.3 L+₹1.2 L (3.54%)Accepted-Finance | ₹36.3 L+₹1.2 L (3.54%) | L3 | Accepted-Finance L3 |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-G.S.T. SEPRATE NOT SUMBITTED AND STAMP DUTY ARTICAL NOT 4 SUMBITTED |
| Sl No | Description | Qty | Unit | JAI SAI ENGINEERING L1 | M/s A S Electrical & Power Controls L3 | SAHANIYA ELECTRICALS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable etc. as required. | 81 | Point | 1,293 ₹1,04,733 Lowest | 1,350 ₹1,09,350 | 1,320 ₹1,06,920 |
| 2.00 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required | 27 | Each | 419 ₹11,313 Lowest | 450 ₹12,150 | 429 ₹11,583 |
| 3.00 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 22 | Nos. | 516 ₹11,352 Lowest | 550 ₹12,100 | 528 ₹11,616 |
| 4.00 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 Amodular switch, connections etc. as required. (For light plugs to be used in non residential buildings). | 24 | Nos. | 596 ₹14,304 Lowest | 620 ₹14,880 | 609 ₹14,616 |
| 5.00 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. | 30 | Nos. | 641 ₹19,230 Lowest | 670 ₹20,100 | 655 ₹19,650 |
| 6.00 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.20mm | 40 | Nos. | 195 ₹7,800 Lowest | 240 ₹9,600 | 200 ₹8,000 |
| 7.00 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 module | 8 | Nos. | 262 ₹2,096 Lowest | 280 ₹2,240 | 268 ₹2,144 |
| 8.00 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. | 100 | Nos. | 49 ₹4,900 Lowest | 70 ₹7,000 | 51 ₹5,100 |
| 9.00 | WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring along with earth wire with the following size of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5sq. mm +1 x1.5 sq mm earth wire. | 170 | Meter | 204 ₹34,680 Lowest | 225 ₹38,250 | 209 ₹35,530 |
| 10.00 | WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring along with earth wire with the following size of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5sq. mm +1 x2.5 sq mm earth wire. | 225 | Meter | 241 ₹54,225 Lowest | 275 ₹61,875 | 247 ₹55,575 |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
27 Mar 2026, 12:00 pmClosed
As Per Tender Notice
As Per Tender Notice
Electrical maintanance work of State Tax Training and Maintenance Institute building at Dehradun
2026_RES_93071_1
RWD_EM_53_2026
Open Tender
Electrical Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,950
EE E/M RWD DEHRADUN
₹97,000
6 Apr 2026
12 Mar 2026
27 Mar 2026
12 Mar 2026
27 Mar 2026
12 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable etc. as required. | - | Point | 1,321.92 | - |
| 2 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required | - | Each | 429.83 | - |
| 3 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | - | Nos. | 528.05 | - |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 Amodular switch, connections etc. as required. (For light plugs to be used in non residential buildings). | - | Nos. | 609.14 | - |
| 5 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. | - | Nos. | 655.1 | - |
| 6 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.20mm | - | Nos. | 200.95 | - |
| 7 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 module | - | Nos. | 268.53 | - |
| 8 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. | - | Nos. | 51.36 | - |
| 9 | WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring along with earth wire with the following size of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5sq. mm +1 x1.5 sq mm earth wire. | - | Meter | 209.96 | - |
| 10 | WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring along with earth wire with the following size of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5sq. mm +1 x2.5 sq mm earth wire. | - | Meter | 247.8 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_110152.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.20 MB
BOQ_110152.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .