GE 871 EWS
GE 871 EWS PIN 913871 C/o 871 EWS
COMPREHENSIVE MAINTENANCE OF MISC E M SERVICES TO ELECTRIC NETWORK SYSTEM OF ZONE III AT JOSHIMATH UNDER GE 871 EWS
2022_MES_568206_1
8713/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Joshimath
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹21,300
Yes
17 Feb 2023
9 Dec 2022
17 Jan 2023
9 Dec 2022
11 Jan 2023
23 Dec 2022
Amount
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 3.0 mtr in depth for foundation. (Laying of under ground cables) in hard dense soil complete all as directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M&L for providing new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable all as specified and directed.
M & L Foundation for steel tubular poles of concrete 15 cm Depth in bottom of Pit for bed concrete (1:4:8) Type D-2 using 40 mm graded aggregate for foundation of poles including necessary frame work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
M & L Foundation for steel tubular poles of PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete including necessary frame work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
Coping for, steel tubular poles (1:2:4) Type B-1 using 20 mm graded aggregate for coping of poles including necessary farm work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
Supply, laying, jointing & testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 120 sqmm 3.5 core all as per IS , specified & directed. NOTE for item Nos 10 to 16 : Excavation & earth work and cable protection such as bricks and GI pipes shall be measured and paid for separately under relevant item of schedule.
Supply, laying, jointing & testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 70 sqmm 3.5 core all as per IS , specified & directed.
Supply, laying, jointing & testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 50 sqmm 3.5 core all as per IS , specified & directed.
Supply, laying, jointing & testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 35 sqmm 3.5 core all as per IS , specified & directed.
Supply, laying, jointing & testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 25 sqmm 3.5 core all as per IS , specified & directed.
Supply, laying, jointing & testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 16 sqmm 4 core all as per IS , specified & directed.
Supply, laying, jointing & testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 10 sqmm 3 core all as per IS , specified & directed.
Supply and fix in replacement of light grade Galvanised mild steel pipe 80mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable portion. NOTE for item Nos 17 to 19 : Excavation & earth work shall be measured and paid for separately under relevant item of schedule.
Supply and fix in replacement of light grade Galvanised mild steel pipe 50mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable protection .
Supply and fix in replacement of light grade Galvanised mild steel pipe 40mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable protection .
Supply and fix in replacement of 1100 Volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular of size of aluminum conductor 6 sq mm stranded conductor including taking down old unserviceable cable all as specified and directed.
Supplying, erecting and fixing in replacement of steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & white paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in white paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type/size complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Supply and fixing LED Street light fittings 60 watt 230V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection type complete all as specified and directed.
Supply and fix in replacement LED Flood light fitting 100 watt energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 , suitable for general purpose lighting etc complete fixed bracket made out by GI pipe (light grade) of suitable size and MS clamp and nut bolts washers etc complete and connected with twin core cable 4 sqmm from flood light to fittings connector all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge. NOTE :- GI earth wire and protection pipe beyond 7.5 mtr will be measured and paid separately. (Note : 1. If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost paid by Dept.)
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as directed. Note :- (a). The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b). Prooning of all tree branches up to 6 inches girth in one tree shall be measured as one Job. (c). Contractor will employ sufficient labour to complete the job with in time as directed. (d). Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e). Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply . However full assistance will be provided by MES staff. (f). The contractor will provide proper tools and safety devices to his staff for prooning of trees.
M & L for Re-stretching of loose over head ACSR conductor of any type/GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire all as specified. ( Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge) . Note:- Five lines together will be measured as one span from pole to pole.
M & L for Painting to poles (9/11 mtr long) including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5mtr height complete, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed
Supply, fixing in replacement, connecting and testing of MCCBs in existing LT panel box / feeder pillar boxes of capacity 160 Amps 4 pole breaking capacity 25 KA with thermal as well as magnetic balance adjustable type complete all as specified and directed.
Ditto- all as per Item No 28 but 63 Amps and 16 KA.
Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and material and labour for PCC 1:2:4 type B1,20mm graded stone aggregate of size 600X600X300mm including form work and plastering and two coat of white wash complete all as specified and directed.
M&L in replacement for earthing complete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6.30 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead incased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg)duly reinforced with mild steel round bars 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work including laying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion..NOTE :- GI earth wire and protection pipe beyond 7.5 mtr will be measured and paid separately. (Note : 1. If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost paid by Dept.)
S&F in replacement of Pole box size 400 x 250 x 150 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 6 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp 02 Nos with nuts, bolts and washers complete all as specified and directed. Make : HPL, C&S, Gaurav
M&L for LT Straight through joint kit for 120 Sqmm size including dismantling of existing complete all as specified and directed by Engr- in-charge.
Supply and Replacement in repair of Stay assembly complete with accessories i.e stay plate 300mm x 300mm x 6mm, galvanized thimbles, G.I. stay wire 7/4 SWG, loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No.1 on Ser Page No.19-47 of MES Schedule Part-I complete. Note : Stay clamp, excavation and earth work and concrete for stay pit and insulator shall be measured and paid for separately.
Supply and replacement in repair of broken earth pit of size 350x350x350 mm made of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site with testing result. complete all as specified and directed.
Supply & fix in replacement, testing, commissioning of LT panel board of size 1.0x0.80x0.30 Mtr, weather proof, outdoor type powder coated, double door shutter, made out of CRCA sheet 3 mm thick outer and 2.00 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed Aluminium bus bar chamber including necessary insulator suitable for 3 phase, 4 wire 50 Hz AC, CPRI approved including PCC block type 0.20 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc.The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron ). The LT panel shall comprises of the following:-
(a) Aluminium bus bar capacity 400 Amps for Phase-R-Y-B-3 Nos & neutral -1 No
(b) MCCB Four Pole 25 KA 160 Amps- 1 No(I/C)
(c) MCCB Four Pole 16 KA 63 Amps - 1 No(O/G)
(d) MCCB TP 16 KA 40 Amps - 1 No(O/G)
(e) MCCB DP 16 KA 40 Amps - 8 Nos(O/G)
(f) MCB DP 10 KA 20 Amps - 01 No(O/G)
(i) complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder
(a) Aluminium bus bar capacity 400 Amps for Phase-R-Y-B-3 Nos & neutral -1 No ( Including provision for 10 Nos of outgoing
(b) MCCB Four Pole 25 KA 100 Amps - 1 No(I/C)
(e) complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp.
(a) Aluminium bus bar capacity 400 Amps for Phase-R-Y-B-3 Nos & neutral -1 No ( Including provision for 8 Nos of outgoing
(b) MCCB Four Pole 16 KA 63 Amps - 1 No(I/C)
(e) complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp for R,Y & B.
Supply and fix in replacement of old unserviceable lugs after cutting the worn out /faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable 3.5 core upto 50 Sqmm including necessary connection complete all as specified and directed.
All as per item No 39 above but aluminium lugs of size 70 to 120 Sq mm.
Supply and fix in repair of aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rowel plugs etc for conductor for roof and fixed on wall upto test point all as specified.
Supply and fix in replacement of galvanized iron strip 32 x 6 mm fixed with saddles & fixing screws, PVC dash fasteners, insulators fixed from test point to earth on walls or buried in ground /drawn into hume pipe complete all as specified and directed. NOTE : Excavation & earth work shall be measured and paid for separately under relevant item of schedule.
Supply and fix in replacement of wooden block heavy weight of size 15x15x15 cm with hole of 8 cm depth & suitable dia for fixing of air termination rod of any size incl dismantling and taking down old existing unserviceable wooden block complete all as specified and directed.
Supply and fix in replacement of GI tubes light grade, galvanised, 20mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for fixing of air termination incl dismantling and taking down old existing unserviceable GI tubes light grade complete all as specified and directed.
Supply and fix in replacement of five pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
Supply and fix in replacement of Test point terminal block made of gun metal or phosphorous bronze 75 x 75 x 25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point completed all as specified.
Supply and fix in replacement cable separator heavy duty made of plastic with PVC clamps heavy duty three phase separator complete all as specified and directed.
Supply and fix in replacement cable separator heavy duty made of plastic with PVC clamps heavy duty two phase separator complete all as specified and directed.
M & L in replacement of ACSR conductor of size 6/1 x 2.59 (Weasel) and 6/1 x 2.11 (Squirrel) ISI marked for LT over head lines on poles including stretching, tightening of poles insulator with winding wire of suitable size with insulator/stretching of ACSR conductor all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4 mm dia as in repairs complete all as specified and directed.
M&L for RCC (Nominal mix ) type B1 1:2:4 (20mm graded aggregate ) in foundations , including rafts footings , foundations beams: plinth beams , bases for columns under reamed piles and mass concrete including demolition of existing complete all as specified and directed
M&L for mild steel TMT bars 100 dia and over , cut to length , bent to shape required , including , cranking , bending spirally for hooping for column , hooking ends and binding with including mild steel wire (annealed ) not less than 0.9 mm dia or securing with clips complete all as specified and directed
M& L for taking out the High mast light pole of length 11 mtrs and care fully shifting to new position including installation of lights in it complete all as specified and directed. Note : Excavation , returning filling and RCC will be measured and paid separately under respective schedule
Mani Control System
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .