| 1 | L1₹10.0 LAdmitted-Finance MUNICIPALITY ROAD OPPOSITE DPL BHAT BUILDING KARAN NAGAR BATAMALOO SRINAGAR SRINAGAR JAMMU KASHMIR 190010 | SRINAGAR | JAMMU AND KASHMIR | 190010 | L1 | Admitted-Finance | |
| 2 | L2₹10.4 L+₹38,350 (3.85%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹11.2 L+₹1.2 L (12.1%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹11.2 L+₹1.3 L (12.8%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹11.4 L+₹1.4 L (14.0%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AL HASSAN ASSOCIATES L1 | HARMUKH INFRASTRUCTURE PRIVATE LIMITED L2 | SHEIKH ELECTRICALS L5 | Arise Techno L4 | J.B.M ELECTRICALS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.01 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles with pit excavation [IS 2713 410 SP 15] | 50 | Nos | 6,25,000 ₹6,25,000 Lowest | 7,44,950 ₹7,44,950 | 7,40,000 ₹7,40,000 | 7,25,000 ₹7,25,000 | 7,90,000 ₹7,90,000 |
| 1.02 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and Laying of 0.05 ACSR Conductor | 2.5 | KM | 1,10,000 ₹1,10,000 | 1,12,500 ₹1,12,500 | 1,46,250 ₹1,46,250 | 1,16,250 ₹1,16,250 | 55,000 ₹55,000 Lowest |
| 1.03 | Providing & Painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) | 50 | Nos | 30,000 ₹30,000 | 10,000 ₹10,000 Lowest | 12,500 ₹12,500 | 17,500 ₹17,500 | 20,000 ₹20,000 |
| 1.04 | Supply,installation, testing and commissioning of Galvanized Nuts and Bolts of sizes. | 80 | Kgs | 9,600 ₹9,600 Lowest | 9,600 ₹9,600 Lowest | 11,200 ₹11,200 | 11,600 ₹11,600 | 12,000 ₹12,000 |
| 1.05 | Providing & Laying of Cement bottoming 1:2:4 mix as per Standards 0.40 cum per pole for ( 8 Mtr) | 50 | No | 1,55,000 ₹1,55,000 | 99,950 ₹99,950 | 97,500 ₹97,500 Lowest | 1,22,500 ₹1,22,500 | 1,10,000 ₹1,10,000 |
| 1.06 | Providing & fixing of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm | 50 | No | 38,000 ₹38,000 | 24,950 ₹24,950 Lowest | 48,500 ₹48,500 | 60,000 ₹60,000 | 65,000 ₹65,000 |
| 1.07 | Supply,installation, testing and commissioning of 16 KN Polymer Shackle Insulators LT | 150 | No | 10,500 ₹10,500 | 3,000 ₹3,000 Lowest | 35,250 ₹35,250 | 37,500 ₹37,500 | 30,000 ₹30,000 |
| 1.08 | Supply,installation, testing and commissioning of GI Mukey for Shackle Insulator with Bolt of (50x6)mm | 150 | No | 16,500 ₹16,500 Lowest | 30,000 ₹30,000 | 40,500 ₹40,500 | 30,750 ₹30,750 | 33,750 ₹33,750 |
| 1.09 | Providing of Stencil and Spray Painting (Black in Colour) on each Pole at an height of 4.5 feet above ground levelwith following specification:
1.The Dimension of the Stensil should be not less than 21"x9" per pole.
2.The following details are to be recorded on each pole with the Spray paint.
a). Name of the Work
b)Year
c). name of the Contractor
d). SR of the pole
The said Stensil should be approved by EDV Ganderbal | 50 | Nos | 2,500 ₹2,500 | 500 ₹500 Lowest | 3,750 ₹3,750 | 2,500 ₹2,500 | 1,500 ₹1,500 |
| 1.10 | Pre and post Geo tagged photographic Evidence consisting of 5x7 inch Photographs in coffee table book and autocad single line diagram= 10JOB | 1 | Job | 10 ₹10 Lowest | 10 ₹10 Lowest | 900 ₹900 | 700 ₹700 | 1,000 ₹1,000 |
Tender Value
₹10.7 L
EMD Value
₹21,400
Closing Date
6 Oct 2025, 4:00 pmClosed
Ex Engineer ED Ganderbal
Office of the Ex Engineer ED Ganderbal
Replacement of Wornout Conductor and Rotten Poles for ED Ganderbal-Retender
2025_PDD_287590_1
EDG/V/085 OF 2025-26
Open Tender
Electrical Works
Lump-sum
20 days
GANDERBAL
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Ex Engineer ED Ganderbal
₹21,400
10 Oct 2025
9 Sept 2025
7 Oct 2025
9 Sept 2025
6 Oct 2025
9 Sept 2025
9 Sept 2025 - 10 Sept 2025
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles with pit excavation [IS 2713 410 SP 15]
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and Laying of 0.05 ACSR Conductor
Providing & Painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Supply,installation, testing and commissioning of Galvanized Nuts and Bolts of sizes.
Providing & Laying of Cement bottoming 1:2:4 mix as per Standards 0.40 cum per pole for ( 8 Mtr)
Providing & fixing of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
Supply,installation, testing and commissioning of 16 KN Polymer Shackle Insulators LT
Supply,installation, testing and commissioning of GI Mukey for Shackle Insulator with Bolt of (50x6)mm
Providing of Stencil and Spray Painting (Black in Colour) on each Pole at an height of 4.5 feet above ground levelwith following specification: 1.The Dimension of the Stensil should be not less than 21"x9" per pole. 2.The following details are to be recorded on each pole with the Spray paint. a). Name of the Work b)Year c). name of the Contractor d). SR of the pole The said Stensil should be approved by EDV Ganderbal
Pre and post Geo tagged photographic Evidence consisting of 5x7 inch Photographs in coffee table book and autocad single line diagram= 10JOB
HARMUKH INFRASTRUCTURE PRIVATE LIMITED (BID ID -2576195)
J.B.M ELECTRICALS (BID ID -2574832)
Arise Techno (BID ID -2573994)
SHEIKH ELECTRICALS (BID ID -2575271)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .