Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.4 LAccepted-AOC | L1 | Accepted-AOC Since L1 bidder | |
| 2 | L2₹87.5 L+₹2.1 L (2.46%)Rejected-Finance AK DEB ROAD GANESHPURA GUWAHATI ASSAM 781025 | GUWAHATI | KAMRUP METROPOLITAN | ASSAM | 781025 | L2 | Rejected-Finance Since not L1 bidder | |
| 3 | L3₹100.0 L+₹14.5 L (17.0%)Rejected-Finance | L3 | Rejected-Finance Since not L1 bidder | |
| 4 | L4₹1.2 Cr+₹33.1 L (38.7%)Rejected-Finance | L4 | Rejected-Finance Since not L1 bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Recce/Site report not found attach and OEM of Similar work not found attach and Justification of Pre Bid meet not found |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
30 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commanding Officer 237 Engineer Regiment
237 Engineer Regiment Military Station Likabali
Supply and Construction of 01 x OJL Living Shelter
2025_ARMY_716191_1
OT/EC/3/56/2025-26/2274 (S and C)
Open Tender
Civil Works
Works
180 days
FOR TATO (FSC) MILITARY STATION TATO (FSC)
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
SBI Likabali
₹1.5 L
237 Engineer Regiment
7 Jul 2025
23 Jun 2025
1 Jul 2025
23 Jun 2025
30 Jun 2025
24 Jun 2025
26 Jun 2025
Amount
Supply and Construction of Pre-Engineered portal frame Modified Double Storey PUF Shelter of size 27.40m x 6.60 m including verandah including roof covered steel staircase with SS handrails on one side of the shelter as in drawing. The structure made of primary members of High Tensile Steel (340 Mpa min) and Secondary members of (240 Mpa) steel. The main wall and partition wall if any, will be made up of 60 mm thick PUF Panels. The Mezzanine Floor shall be with 1.0 mm Thick Galvanized Deck sheet as per specification attached. Layout of partition walls of ground and first floors, if any, will be as per the respective floor plans attached. The main beam of stair case is made up of built-up C section of size 75 mm, 200 mm, 8/10 mm and step platform are made up of chequered plate 4 mm thick. The side railings are made up of stainless-steel square hollow sections of 32 mm x 32 mm x 2.9 mm @ spacing not greater than 300 mm. The roofing will be made of 0.50mm PPGI colour coated sheets. Other specifications are as per description given under each specification and drawings. Detailed specification of shelter as per Appx 'A'.
Constr mtrl for OJ Living shelter (D/S). Detailed specification as per Appx 'B'. Store list of constr mtrl for civil work and elect items as per Annx - I.
(a) Provn of Single bed hard with Coir Mattress as per tech specification given in Appx 'C'
(b) Provn of Table Bed side as per tech specification given in Appx 'C'
(c) Provn of Chair Writing as per tech specification given in Appx 'C'
(d) Provn of Writing Table as per tech specification given in Appx 'C'
(e) Provn of Center Table as per tech specification given in Appx 'C'
(f) Provn of Shoe Rack steel as per tech specification given in Appx 'C'
(g) Provn of Almirah large steel as per tech specification given in Appx 'C'
(h) Provn of Bath Mat PVC as per tech specification given in Appx 'C'
(j) Provn of Table Dressing as per tech specification given in Appx 'C'
(k) Provn of Sofa single Seater as per tech specification given in Appx 'C'
(l) Provn of Kerosene Heat King Bukhari as per tech specification given in Appx 'C'.
(m) Provn of Water Dispensor as per tech specification given in Appx 'C'
Supply and Constr of interlocking paving blocks for pathway as per detailed specifications given as per Appx 'D' and store list as per Annx - II.
(a) Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall/ceiling/roof. The unit to have sensor capable of covering area >40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery, including supply two Nos of battery. (Make : Fire End/AFO/Safe Guard)
(b) Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall/ceiling/roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery, including supply two Nos of battery. (Make : Fire End/AFO/Safe Guard)
(c) Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free, non toxic, envoronment friendly and suitable for all type of fires. (Make : Fire End/AFO/Safe Guard/Kanex/Fire Stop/Elide or Equivalent)
Suntech Systems Pvt.Ltd. (BID ID -3340709)
VISION SUPPLIERS AND CONST CO (BID ID -3338974)
Empresa Inc (BID ID -3340565)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .