Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.1 LAccepted-AOC | ₹51.1 L | L1 | Accepted-AOC Work awarded to lowest bidder |
| 2 | L2₹59.1 L+₹8.0 L (15.7%)Rejected-Finance VILLAGE AND POST OFFICE LUJ TEHSIL PANGI DISTRICT CHAMBA | ₹59.1 L+₹8.0 L (15.7%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹59.6 L+₹8.5 L (16.5%)Rejected-Finance NOT AVAILABLE | ₹59.6 L+₹8.5 L (16.5%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹63.9 L+₹12.8 L (25.0%)Rejected-Finance KALIJHORA KALIJHORA BAZAR KALIJHORA BAZAR KALIJHORA BAZAR DARJEELING WEST BENGAL 734008 | DARJEELING | WEST BENGAL | 734008 | ₹63.9 L+₹12.8 L (25.0%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹73.5 L+₹22.3 L (43.7%)Rejected-Finance VILL SAKRAH PO CHAMBI TEHSIL SUNDERNAGAR DISTT MANDI HP | SUNDERNAGAR | MANDI | HIMACHAL PRADESH | ₹73.5 L+₹22.3 L (43.7%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹67.7 L
EMD Value
₹1.0 L
Closing Date
2 Jan 2024, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Sundernagar
CO RCC desilting tank CO RCC sump well 75000 ltrs. capacity CO pump house and electrical wiring to pump house laying jointing and testing of rising main 150mm dia CO steel trussed Nallah crossing CO delivery tank 12000 ltrs. CO site development and p
2023_HPIPH_83114_1
EE JSD SNR TA etender 2023-15567-620 dt 23.12.2023
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
180 days
Sundernagar
Please refer Tender documents.
9 documents required · 9 mandatory
₹800
₹1.0 L
Yes
16 Feb 2024
23 Dec 2023
3 Jan 2024
23 Dec 2023
2 Jan 2024
23 Dec 2023
Amount
Excavation in foundation, trenches ( for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of each deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration unmetalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-charge.
Providing and laying cement concrete 1:6:12(1 cement:6sand:12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete in all respect in all leads and lifts.
Providing and laying cement concrete 1:4:8 (1 cement:4sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete in all respect in all leads and lifts.
Providing and laying cement concrete 1:2:4 (1 cement:2sand:4 graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete in all respect in all leads and lifts.
Providing and laying cement concrete 1:3:6 (1 cement:3sand:6 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete in all respect in all leads and lifts.
Providing and laying cement concrete 1:1.5:3 (1cement:1.5 sand : 3graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work and re-inforcement for reinforced concrete work complete in all respect in all leads and lifts in :(a) Foundations, footings, bases of columns and the like and mass concrete.
(b) Walls ( any thickness but not less than 0.1 m thickness) attached pillasters, buttresses, plinth and string courses, etc. from top of foundation level upto floor two level.
(c )Suspended floors, roofs, landing, shelves and their supports balconies, lintels, beams girders bresumers and cantilevers upto all floor two level .
(d) Beams, Cantilevers, girders and lintels : Sides and soffits of beams, beam haunchings, cantilevers, girders , bressumers and lintels not exceeding 1 metre in depth.
Providing tor steel reinforcement for RCC work including bending, binding and placing in position complete upto floor two level in all leads and lifts.
Brick work using common burnt clay building bricks in foundation and plinth in :- Cement mortar 1:6 (1 Cement : 6 Sand) second class Bricks ( i) Superstructure above plinth level upto flor two level :- (SECOND CLASS BRICKS)
Stone soling/boulder filling dry hand packed under floor etc. complete in all respect in all leads and lifts.
Cement concrete flooring 1:2:4 (1cement:2sand: 4 graded crushed stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement in all leads and lifts. (a) 40mm thick
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought , framed and fixed in position 2nd class deodar wood in all leads and lifts.
Providing form work with steel plates 3.15mm thick welded with angle iron 30x30x5mm so as to give a fair finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4mtrs. and removal of the same for in-situ reinforced concrete and plain concrete work in all leads and lifts (a) Vertical surface such as walls(any thickness) partitions and the like including attached pillasters buttresses, plinth and string courses and the like
(b) Foundations, footings, bases of columns and the like and mass concrete.
Beams, Cantilevers, girders and lintels : Sides and soffits of beams, beam haunchings, cantilevers, girders , bressumers and lintels not exceeding 1 metre in depth.
Providing form work of ordinary timber plankings so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4mtrs. and removal of the same for in-situ reinforced concrete and plain concrete work in all leads and lifts (a) Acrches, domes, vaults upto all span complete in all respect in all leads and lifts.
Laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding in three layes) and testing of GMS Medium Class pipes of following dia meters confirming to BIS 1239 (Part-1), grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends, Tee etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately) (i) Raw water stage 150mm dia (M) wall thickness 4.8mm
(ii) Ist stage 150mm dia (M) wall thickness 4.8mm
Providing welding and fixing of MS flanges at suitable reaches, conforming to Table as per IS: 6392-1971 (Latest with upto date amendments) and welding of MS flanges with G.I. pipes/MSERW pipes in two layers on both faces to make the joing leak proof. (The cost of providing and laying of GI pipes/MSERW pipes to be measured and paid for separately). The welding of flanges should conform to IS: 816-1969 with electrode as per per IS:814-1991 and required number of nuts & bolts conforming to IS: 1364. The thickness of gasket not less than 3.00mm conformig to IS: 2712-1998. The work shall be done including all leads and lifts and as per entire satisfaction of the Engineer-in-charge.(i) 150mm dia Table-17
(ii) 150mm dia F-T 5
Providing, supplying and fixing cast Iron double flanged sluice valve as per IS:14846/2000 latest with upto date ammendments of Kirloskar / Leader / KSB / Kartar / Pelican make of following diameter, PN-1.6 including MS Flanges Table - 17, confirming to IS: 6392-1971 or latest with upto date ammendments including cutting of pipes wherever required, welding in three layers (leak proof) confirming to specifications as perescribed in relevant IS code i.e. IS: 816-1969 or latest as applicable with upto date ammendments with nuts, bolts, washers & specials etc. confirming to relevant IS code or latest with upto date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorrosive paints complete in all respect including all leads and lifts and as per entire satisfaction of the Engineer-in-charge (i) 150mm dia
Providing Installation in position, tube settler media PVC TUBE SHETTLER COOL TUBES CD-TS120-1155 MM Long, minimum plate thickness of Chevron- Unequal Hexagon shape, with VERTICAL HEIGHT : 1000 MM to be placed to an ANGLE OF INCLINATION- 60 DEGREE in the position as per CPHEEO Manual and relevant HSN Code complete with all leads & lifts upto the satisfaction of Engineer-in-Charge.
Providing and fixing precast concrete manhole cover & frame conforming to IS: 1259301988 part-I and IS 12592-1991, Part-II 560mm diameter medium duty complete in all respect in all leads and lifts.q
Fixing of GI pipe light grade for inlet, scour and over flow pipe (Labour rate) 150mm dia in all leads and lifts.
Providing, supplying and fixing Cast Steel double flanged Non Return valve as per IS:5312/2004 latest with upto date ammendments of Kirloskar / Leader / KSB / Kartar / Pelican make of following diameter, ASA-300 including MS Flanges Table - 17, confirming to IS: 6392-1971 or latest with upto date ammendments including cutting of pipes wherever required, welding in three layers (leak proof) confirming to specifications as perescribed in relevant IS code i.e. IS: 816-1969 or latest as applicable with upto date ammendments with nuts, bolts, washers & specials etc. confirming to relevant IS code or latest with upto date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorrosive paints complete in all respect including all leads and lifts and as per entire satisfaction of the Engineer-in-charge (i) 150mm dia for inlet, common header and scour valves
Steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint:- In gratting, framed guard bar, ladders, railing brackets and similar works complete in all respect in all leads and lifts.
Steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint in trusses and trussed purlins in building complete in all respect in all leads and lifts.
Steelwork welded in built up sections including ctting hoisting fixing in positions and applying a priming cot of lead painting trusses steel bridge
Hoisting steel truss bridge complete in all respect in all leads and lifts.
Providing and fixing in position cast steel fixture like saddies rockers and roller bearing alongwith rollers grease box and other fixture complete in all respect.
Providing and fixing Aluminium ladder 4.00 m length capable to carry minimum 200 kg load, for lowering/cleaning & inspection of storage tanks in all lead and lifts to the entire satisfaction of Engineer-in-Charge.
Providing and Fixing wire gauge using galvanised M.S. wire gauge of I.S. gauge designation 85 G. with wire of dia 0.56 mm for Ventilator of tank complete in all respect in all leads and lifts.
Finishing walls with water proofing cement paint of approved brand and manufacture of required shade on undecorated wall surface ( two coats) to give an even shade after throughly brushing the surface to remove all dirt,dust and remains of loose material sand papered,stopping complete in all respect.
Providing 40x3mm iron hold fast 40cm long including fixing to frame with 10cm dia bolts, nuts and wooden plugs and embending in CC block 30x10x15cm 1:3:6(1cement :3sand:6 graded stone aggregate 20mm nominal size)
Providing and fixing panelled glazed or panelled and glazed shutters for doors, windows and clerestory window including black enamelled iron butt hinges with necessary screws in all leads and lifts..(i) 40mm thick 2nd class deodar wood.
Providing and fixing MS grills of required pattern in wooden frame of window etc. with M.S. flats, square or round bars with round headed bolts and nuts by screws plain grills in all leads and lifts.
Providing and fixing anodized MS sliding door bolts with bolts and nuts screws etc. complete.(i) 250 x16 mm
Providing and fixing aluminium tower bolts ( barrel type) with screws etc. complete.(i) 250 x 10 mm
(ii) 150x10mm
Providing and fixing Aluminium handles anodized transparent or dyed to required colour & shade with necessary screws etc. complete.(i) 125mm dia
Providing and fixing bright finished brass floor door stopper with rubber cushion screws etc. to suit shutter thickness complete in all respect.
15mm cement plaster in single coat on rough side of brick/ concrete/ stone walls for interior plastering upto floor two levels including arrises internal rounded angles chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6 (1cement:6sand) in all leads and lifts.
Providing and fixing 0.60 mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 microns over 5 microns primar coating including fixing with prepainted iron J or L hooks, bolts and nuts 6 mm dia meter with prepainted limpet and rubber washers complete with all accessories as required by Engineer-in- charge.
Providing and fixing ridges or hips 60 cm overall with 0.60 mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 microns over 5 microns primar coating including fixing with prepainted iron J or L hooks, bolts and nuts 6 mm dia meter witrh prepainted GI limpet and bitumen washers complete with all accessories as required by Engineer-in- charge.
Applying one coat of Acrylic primer(Spectrum or equivalent of Superior quality) on new concrete/masonry/plastred surfaces after and including preparing the surface by thorughly brushing the surface free from mortar droppings and other foreign matters, sand papering the surface smooth complete.
Wall painting (two coats) with plasic emulsion paint of approved brand and manufacture on unecorated wall surfaces to give an even shade including thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth including applying of putty as required for making the surface.
Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,greese,dirt and other foreign matters,sand papering and knotting.Ready mixed paint brushing wood primer pink.
Painting two coats (excluding priming coat) on new wood and wood based surfaces,with enamel paint to give an even shade including cleaningthe surface of dirt ,dust and other foreign matters sand papering and stopping with enamel paint other than white
Wiring for light point/fan point/ exhaust fan/ call bell point wiwth 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and eahing the light point with 1.5 Sq. mm HRFRLS/PVC insulated single core copper conductor cable as required Group C.
Wiring for light plug with 2 x 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. 1.5 Sq. mm HRFRLS/PVC insulated sigle core copper conductor cable for earthing as required.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. Sq. mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying & fixing metal box of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required:-(i)100mmx 100mm x 60mm deep
P/F 5 Pin 5/6 amps socket outlet porcelain base piano type
Providing, Installation, tesing and commissioning of ceiling fan 1200 mm sweep, (Category-A) with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable , including providing and fixing phenolic laminated sheet cove on the fan box and eathing etc. as required
Providing installation testing and commissioning of pre-wired, fluorescent light fitting/ compact fluorescent fitting of all types complete with all accessories and tubes etc. directly on ceiling / wall, including connections with 16/0.20 mm twin twisted flexible cotton braided, copper cable and eathing etc. as required:-
Supplying and fixing of bulk head fitting of all sizes and shapes, containing one no thread type CFL lamp holder (s) complete with all accessories but excluding CFL lamp including making connections. Testing etc. as required.(i) Bulk head fitting, CFL type (Category-A)
Supplying and fixing of 20 mm diameter PVC conduit along with the accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required :-
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 Amps. Cat-A
Wiring for circuit/ sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(i) 2x10 Sq. mm.
(ii) 2x6.0 Sq. mm.
(iii) 2x4.0 Sq. mm.
Supplying and fixing of single door 4 way, single pole and newtral sheet steel MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus-bar, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Raw water stage including Low cost automation:- Providing, fixing, testing and commissioning of raw water submersible pumping set to handle the turbidity of 4000PPM of appoved make such KSB/BS/JOHNSION/ Oswal make or other make approved by HPJSV conforming to latest relevant BIS code. The pump should be fitted with free flow impellers of bronze/suitable alloy as per BIS 5659-1972 latest suitable for clear water of IS: 5659-1970 having greased packed bearing and shaft with bound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor(water proof) of reputed make Kirloskar/ NGEF/Jyoti/Crompton make conforming to BIS 9283-1979 latest with upto date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechnical seal in oil chamber & grease packed lubricated bearing & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with heating of motor. The pump set should include water level guards errection clamps, cable clips & depth gauge etc. & suitable for operationof pumping macninery. It includes the installation of star delta starter panel, protection devices, MCCB/MCB, PLC, HMI, Level sensors and other appliances (as per Technical Specifications attached) tro make the system fully functional to the entire satisfaction of Engineer-in-charge. Pumping system should be compatible for (i) Total head 30.53 mtr. Disharge 19.92 LPS each set, 2 sets (one standby)
First stage including Low cost Automation:-Providing,Fixing, Testing & Commissioning including automatioin of horizontal spindle,horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage star rated centrifugal pump or combination of pumps, of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti or any approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water having turbidity upto 4000 ppm for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 45C8/ EN8 with cast iron casing coupled directly through a flexible coupling on a common MS Base Plate to squirrel cage/TEFC Energy efficient motors ( Conforming to energy efficiency code IE2 or higher ) of standard make such as Kirloskar /BHEL /CG POWER /Siemens /Jyoti /ABB /Marathon or other make approved by the JSV and suitable for operation on 415 (+10% ) and ( -10% ) volts, 50 cycles / second, 3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements: including Pump sets (working + standby ), necessary piping for suction, delivery & common header, alongwith electrical control panel with soft starters; as per requirement of pumping machinery; Complete work inclusive of all taxes,transportation, freight charges, inspection charges, loading, unloading, conveyance to Departmental stores / site, stacking, etc. including specials and wastage etc. It shall include providing and fixing of C.I/C.S Sluice valves of approved make and appropriate class to resist the design pressure and complete as per Tender Specifications and instruction of Engineer in charge. It includes the installation of star delta starter panel, protection devices, MCCB/MCB, PLC, HMI, Level sensors and other appliances (as per Technical Specifications attached) tro make the system fully functional to the entire satisfaction of Engineer-in-charge. Pumping system should be compatible for Total head 92.70 mtr. dishcarge =9.96 LPS each set, 2 sets (one standby) for Ist stage
BHUPENDER THAKUR
ANKUSH KUMAR
Royal Construction Company
KUSHAL SINGH RAGHAV
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .