Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹2.7 L+₹14,254 (5.54%)Rejected-Finance | L2 | Rejected-Finance Higher Bid | |
| 3 | L3₹3.8 L+₹1.2 L (48.4%)Rejected-Finance | L3 | Rejected-Finance Higher Bid |
Tender Value
₹2.6 L
EMD Value
₹5,196
Closing Date
7 Oct 2024, 2:00 pmClosed
Assistant Engineer, PWD Kakdwip Electrical Sub-Div
Office of the Assistant Engineer, Kakdwip Electrical Sub-Division, P.W.D Purta Bhavan, Kakdwip, South 24 Pargnas.
Urgent Illumination work of security light for Implementation of RATTIRER SATHI at Nurses Quarter Main Hospital Building under Kakdwip S D Hospital under Kakdwip Electrical Sub Division PWD
2024_WBPWD_761588_1
WBPWD/AE/KESD/eNIT01/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Kakdwip Sub-Divisional Hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,196
19 Nov 2024
3 Oct 2024
9 Oct 2024
3 Oct 2024
7 Oct 2024
4 Oct 2024
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal &vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] (Avg. run 8 mtr.)
Supplying and fixing 240 V, 32A, DP Main Switch with sheet steel enclosure on flat iron frame on wall with nuts bolts etc incl. S & F 2 nos. kit kat fuse as per rating. (Make-Siemens/L & T/Havells/Standard)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & nsheathed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. a)2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC ( For Separate Board)
COMPOUND LIGHTING: S & D of 240V, (70 W )8400 Lumens (minimum) LED Street Light Fittings with IP 66/ 67, IK 10 protection including 10 KV SPD with CCT 5700K & Luminious efficacy 120Lumen/Watt minimum or better, burning hour 100000 at L70850, LED Driver should with stand 440V for 8 hours Inbuilt surge protection 4 KV and 10 KV Surge protection inside lumunaries. The LED luminaires and accessories shall have BEE Certification & LED should be with lens (Light efficacy will not get depriciated less than equal to 70% of the rated value over the lifetime of the Luminaries) (Make: Philips(Signify) / WIPRO/Havells/ Crompton) (Manufacturer warranty should not less than 3 years) on existing minipole with replacecing the old one.
COMPOUND LIGHTING: S & D of 240V, (90 W )10800 Lumens (minimum) LED Street Light Fittings with IP 66/ 67, IK 10 protection including 10 KV SPD with CCT 5700K & Luminious efficacy 120Lumen/Watt minimum or better, burning hour 100000 at L70850, LED Driver should with stand 415V for 8 hours Inbuilt surge protection 4 KV and 10 KV Surge protection inside lumunaries. The LED luminaires and accessories shall have BEE Certification & LED should be with lens (Light efficacy will not get depriciated less than equal to 70% of the rated value over the lifetime of the Luminaries) (Make: Havells/ Philips(Signify) / WIPRO/ Crompton) (Manufacturer warranty should not less than 3 years).
COMPOUND LIGHTING: Supply & delivery of 240V, 25W (Maximum) LED street light with IP-66, individual Secondary Optics Peanut Lens and Separate Toughned Glass Diffuser, Potted Driver to be used, 2500 lumen (minimum) output fittings, as directed by EIC. [Make: Havells ENDURASUNDOWNSL25WLED765PASY BOPC or equivalent spec of Philips/Crompton]
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
Supply Delivery of 1.1 kv grade 2Cx6 sqmm XLPE-armoured AL. cable, as directed by EIC. [Make - Polycab/KEI/RR Kabel/Gloster] (for Compound light.)
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying of above 2Cx6 sq.mm. XLPE/Ar. AL Cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed, as per GS.
S/F compression type cable end gland with finishing end by crimping method for the following size for 2Cx6 sqmm XLPE- A/Al armoured cable as per GS.
S/F Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket 2Cx6 sqmm (Dowels make), tapes, anticorrosive paste & jointing materials as per GS.
SSupply & delivery of swaged type MS Steel tubular pole conforming to IS:2713/1980 (9 mtr long, 410-SP-28), incl. painting with 2 coat of RO primer & 2 coat of aluminium paint of approved make & brand after proper scrapping the surface as per direction of EIC incl. S &F of MS base Plate. Approx weight of the Pole 113 kg. [Make - Bajaj / Utkarsh / Jindal / Subham]
Erection of Single MS Steel Tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly, as per GS. (a) Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
Extra on above item, for providing CC (6:3:1) base block (around the pole) dimension 0.45x0.45x0.60 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 20cmx15cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole, as per GS.
S&F 50 mm 1.5 mtr long detachable type G.I single arm bracket, suitable for polehead . The arm bracket shall be p[roperly weded with 15 mm . Stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the poleby bolts, nuts andwasher as per directionof EIC ( Make - Bansal/ Utkarsh/ subham/Jindal) as per GS
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
S&F of 250V double door Compound light Timer DB [equivalent of 2+8 way SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 25A DPMCB ('C' curve 10KA), 2 no. 16A SPMCB ('C' curve 10KA), 1no. Programmable time switch-24 hrs with minimum switching of 15 minutes and 1 no. 18A/25A 2-Pole power contractor with inner-outer plate & internal wiring by suitable size of cu. wire incl. 1 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. LED indication light for running condition with mechanical locking arrangement, as directed by EIC. [Make-ABB/L&T/Crabtree]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below By ISI-Medium GI pipe.
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil)
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS -- No.-4 SWG
Supply & Fixing 240 V 16 A Modular type switch (Legrand / Havells) on 2 Module GI Modular type switch board having top cover plate and making necessary connections as required as per direction of EIC.
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees.
G.G. PROJECT (BID ID -5678337)
NAYEE DISHA PROJECTS (BID ID -5678303)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .