Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹36 L+₹5.8 L (19.1%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹36.3 L+₹6.0 L (20.0%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹41.9 L+₹11.7 L (38.6%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹44.1 L+₹13.9 L (46.0%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹44.9 L
EMD Value
₹89,752
Closing Date
3 May 2025, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
REPAIR/REPLACEMENT AND MAINTENANCE OF LT CABLES, DG SET, STREET LIGHT, E/M FIRE FIGHTING SYSTEM INCLUDING CONNECTED ITEMS AT AF STN BAKNAUR, KALPI AND RAJPURA UNDER GE (AF) AMBALA
2025_MES_703668_1
GE AF/AMB-T-46/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹89,752
Yes
26 Jun 2025
5 Apr 2025
5 May 2025
5 Apr 2025
3 May 2025
19 Apr 2025
Amount
Excavation in trenches not exceeding 1.5 Mtrs. wide and not exceeding 1.5 Mtrs. in depth for foundation, laying of cables etc and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (Soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 Mtrs. above the starting point complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 25cm depth in soil complete all as specified and directed by Engineer-in-Charge.
Dismantling steel poles/ cement pole / struts, any size from existing deteriorated street pole complete all as specified and directed by Engineer-in-Charge.
Taking down and Checking and repairs to street light fitting from High mast light from pole , Truss ,Highbay light, flood light , Perimeter light , Post Top Lanterns , Obstruction light, Aviation light fittings inside / out side of AF stn Rajpura, AF stn Baknaur, AF stn Kalpi , fitted any height street light pole (9/11) mtrs, truss, wall repair and checking and cleaning internal complete wiring, bulb, ignator, holder, circuit plale , LED bulb, LED driver, rectifying the defects and removing of burnt cable if any including repair/replacing the unserviceable items as mentioned in below items (wherever necessary) and testing the same on ground at site for its serviceability and refixing the same at original place/location complete all as specified and directed by Engineer-in-Charge. Note :- (a) If the contractor have not given job card to his tradesman in any working day and have not attended any complaint , the necessory recovery of Rs. 500/- per day shall be imposed by Engineer-in-charge . (b) Routine check shall be done for all types of non opps street / secutity light fitting in each and every location in routine wise manner every day by tradesman. (c) Driver and cable shall be measured paid and separately
S&F cable junction boxes IP 66/67 weather proof for out door installation with knock outs cable entry junction box size should be 205 x 255 x 112 with terminals including complete all accessories, all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable junction box and S&F of new cable junction boxes IP 66/67 weather proof for outdoor installation (with knock outs cable entry junction box size should be 300 x 100 x 450 mm aluminium bus bar 4 strip mounted on protection insulator with two Nos and front openable hinged and locking arrangements including complete all accessories , all as specified and directed by Engineer-in-Charge.
S&F in replacement 35 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting Source and LENs embedded toughened glass cover with IP66 Protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 45 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting Source and LENs embedded toughened glass cover with IP66 Protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement LED Bldg security light 60 Watt indus series powder coated pressure die cast aluminium high power LED bldg security light with heat resistant toughened glass with lens with IP66 Protection , complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 120 WATT LED street light made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Street light timer, Astronomical time operation, sunrise sunset based operations, Current Rating (In Amps): 20 Amp, Display : Digital, Operating Temperature: -10 to 55, Power/Voltage: 110 - 240VAC all as directed by Engr-in-Charge
S & F in Replacement LED driver for street light / highbay light fitting / flood light from 36 watt to 150 Watt 230 volt of any type and size etc to match with existing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom,class 10 ,all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement hot dip galvanized anti corroded weather proof octagonal electric poles 6 mtrs long top mounting on foundation complete with base plate and final including PCC foundation as per manufacturer design with 1500 mm long Arms bracket, tapper plug,bolts nuts and screws etc as specified complete all as specified and directed including taking out existing damaged pole with street light bracket complete all as specified and directed by Engineer-in-Charge. Make of poles:- National Tubing Co./ Bombay Tubing Ltd / India Tube and Co. / Bharat Conduit & Steel Works as approved by GE.
Supply and fixing in replacement iron clamp (flate 25 x 4 MM) with nuts, bolts, washers and removing old clamps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of new bracket for street/security light fitting made of GI pipe 25 / 40 mm light grade 1.0 m long bend to shape including two Nos of clamps nuts and bolt as required complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of new bracket for street/security light fitting made of GI pipe 50 mm light grade 1.0 m long bend to shape including two Nos of clamps nuts and bolt as required complete all as specified and directed by Engineer-in-Charge.
M&L for in replacement for straight through jointing heat shrinkable kit for cable of 35/50 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
M&L for in replacement straight through jointing heat shrinkable kit for cable of 95 to 185 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
Supply and laying XLPE insulated screened. PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including removing Old concrete cable cover from trenches/walls/ceiling/poles etc any size and taking up old U/S XLPE cable complete all as specified and directed by Engineer-in-Charge.
Taking down old U/S cable and Supply and laying Insulated screened PVC bedded, copper electric cables 1100 Volts grade with stranded Copper conductor of size 1.5 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge.
Taking down old U/S cable and supply and laying Insulated screened PVC bedded, copper electric cables 1100 Volts grade with stranded Copper conductor of size 2.5 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge.
Taking down old U/S cable and supply & laying XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc are deemed to be included in quoted rate and no extra payment will be made for it.
Taking down old U/S cable and supply & laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge.
Taking down old U/S cable and supply & laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Taking down old U/S cable and supply and laying XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed
Taking down old U/S cable and supply & laying XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 3.5 core. laid in duct / along pole/wall including making connection complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement MCCB, 415 volts, 03 pole of cap 63 Amps, 16 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections conforming to IEC 60947-2 , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCCB, 415 volts, 4 pole of cap 100 Amps, 16 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size , making connections & incliding necessary fixing /fitting tools in this qoted rate complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 (using 40mm graded mechanically crushed stone aggreagate) for base of pole including use and waste of form work complete all as specified and directed by Engineer-in-Charge. Note: cost of necessary form work is deemed to be included in the quoted rate
M&L for cement concrete 1:2:4 type B-2 ( using 20mm graded mechanically crushed stone aggregate) for coping of pole complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge. Note : if desired resistance is not found upon testing. Entire Earthing shall be re-done by Contractor at his own cost and no claim on this ground is admissible on this account
Disconnecting electric connections of underground LT, XLPE cable of any size, from both sides and locating/detecting of pin point fault in cable with fault locating machine comprising impulse generator, acoustic fault locator & reflectometer (Laptop based) in the entire length with modern fault detector equipment by expert Engineers including reconnecting & commissioning the cable to make it functional complete all as specified & directed.
S&F HDPE of pressure rating 6kg/cm sq pipe of 90 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge.
S&F HDPE of pressure rating 6kg/cm sq pipe of 65 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge.
M&L for scraping the old paint from steel tublar poles /RCC Pole by wire brush not more than up to 9/11 mtr length above ground level including street light arms applying one coat of steel primer and two coat of aluminium paint and marking pole no. , complete all as specified and directed by Engineer-in-Charge.
M&L for scraping the old paint from RCC poles by brush not more than up to 9/11 mtr length above ground level including street light arms applying two coat of Cement base paint and marking pole no. , complete all as specified and directed by Engineer-in-Charge.
Supply & installation, testing and commissioning in replacement, of outdoor type AMF panel for automatic operation of the DG set, comprising of main and DG contctors , auto unit timers , relay , metering , fuses , incomming MCCB 200 Amps 04 pole, cubicle panel board, 415 V, 3 phase, 4 wire, aluminium bus bar of rating 400 Amps, contractor 125 Amps and made out of 3.15 mm thick CRCA sheet , factory fabricated , CPRI approved , powder coated(seven tank processed) with approved shade ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50 x 50 x 6 mm thick angle iron , grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery, cable glands, cable lugs , bus bar, MCCB fixed vertically with bus bar and double door panel both side double door type (front and back) openable etc all as specified and comprising of including necessary PCC work, cable connections to the MCCBs digital multifunction meter and cable lugs etc . :- (a) Indicator Lamp - 06 Nos (b) Low Voltage Monitor - 01 No © Ammeter - 01 No (d) Voltmeter - 01 Nos - 01 Nos (e) DC Meter -1 Nos (f) Battery Charger 12 V 10 Amp - 01 Nos (g) Auto Manual switch - 01 No (h) Manual load switch -1 No (j) Control MCB - 05 Nos (k) Relay 240 Volt 2C/O - 2 Nos (l) power contractor - 02 Nos (m) MCCB 125 Amps -1 Nos (n) CT 150/5A -01 Nos (o) Aluminium Bus bar - 08 Rm Control wire as required (p) PVC Chanel , Lugs Gasket etc as required
S & F in replacement Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S & F in replacement Pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,gulley gutter and ridges fixed with self tapping screws complete all as specified and directed
S & F in replacement Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-290(Gde E-165)
M&L for two coats of synthetic enamel paint over one coat of red oxide/zinc chrome primer on new steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and as directed..
S & F MS plate ( plain or chequered) channel, square cut or notched ( Fe 410 W Gde E-250 quality-B with riveted, bolted or welded attachment complete all as specified and directed.
Repair /servicing of diesel engine of 500 KVA repair/replacement of the following unserviceable components including opening engine and replacing all gaskets complete all as specified and directed by Engr-in -charge (a) Cylinder head gasket to be repaire (b) Element LO filter with O ring 1 set. (c) Element fuel filter with O ring -1set (d) Filter screen - 2 set (e) Element air cleaner 1 No (f) Element Bypass filter with O ring 1 No. (g) All fuel,oil,and coolent and head need to be changed. (h) Checking water temperature safety control (j) Checking and correcting up impeller of water pump for excess play. (k) Checking and correcting turbocharger oil leakage, tightening of mounting screws and nuts (l) Cleaning, tightening all electrical connection of engine (m) Checking generator brushes (Alternator) and commutator and replacing the brushes. (n) Cleaning of entire engine. (o) Checking exhaust and inlet manifold bolts and cap screw (p) Checking engine blow by. (q) Cleaning of radiator inside and outside by removing and refixing after cleaning. (r) Checking and adjusting injector and valves. (s) Cleaning fuel inlet connections and screw, (t) Changing of governor oil.
All as per item No.-46 here-in-before but diesel engine of 90 to 160 KVA DG set,
S & F in replacement & removing the old engine oil from the diesel engine sump of various DG sets, cleaning the oil sump thoroughly, supply and fill new engine oil of make Servo super 20W40 of Indian oil or equivalent grade of Hindustan Petroleum as directed by Engineer -in -Charge.
Repair/overhauling of self starter including replacement of worn out clutch assembly,bush,spring,plunger assembly, solenoid switch, carbon brushes, brush spring etc. for the following DG Set capacity complete all as specified and directed
Repair/overhauling of dynamo including replacement carbon, brushes holder,spring,commutator/slipring assembly bearing, regulator etc. of any make, type and capacity 500 KVA complete all as specified and directed
Supply and fixing in replacement battery charger 24 Volts suitable for 12 volts 180 AH Battery complete all as specified and directed
Servicing/repairs of AMF panel of DG set complete including cleaning resetting/adjustment of relays, calibration of time delay relays, checking and replacement if required of diods,resistors electrical wiring etc. complete for any make type and capacity 500/160 KVA of DG sets. complete all as specified and directed
S&F in replacement Self starter suitable for 160 KVA DG Set ccomplete all as specified and directed
Caliberation of fuel injector FIP with authorised agencies of 160 KVA DG Set complete all as specified and directed
Caliberation of fuel injector FIP and replacment of unserviceable items with authorised agencies of 500 KVA DG Set complete all as specified and directed
Servicing of alternator including cleaning of field and armature winding, varnishing and baking polishing of slip rings, checking , replace unserviceable AVAR and making correct excitation system etc. complete as specified and as directed for alternators of:-
Cleaning of the fuel tank of the following capacity DG sets after decaning the diesel, painting with one coat of approved colour synthetic enamel paint after thorough cleaning and preparation of surfaces, marking of fuel level gauge, fuel tank cap, writing of tank capacity
S&F in replacement rectifiers for alternators suitable for Gen sets upto 500 KVA capacity complete all as specified and directed
S&F in replacement Air filter suitable for 500 KVA DG Set complete all as specified and directed
S&F in replacement oil filter suitable for 500 KVA DG Set complete all as specified and directed
S&F in replacement MOU of 500 KVA DG Set complete all as specified and directed
Preparation of old painted surface of installation by removing all dirt, dust, grease, oil etc and painting by painting spray machine complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification Nos, capacity etc all as directed by Engineer-in-Charge for DG Set/ LT panel complete all as specified and directed
Repair / Servicing of unserviceable dynamo including cleaning of field and armature winding, varnishing and baking polishing of slip rings, checking and making correct excitation system etc. complete as specified and as directed for alternators of 160 KVA complete all as specified and directed
S&F in replacement dynamo belt as per size of cap 160/ 500 KVA directed by Engr -In -Charge
Opening top /side cover of alternator and disconnect the LT supply cable connecting box /AVAR fixing box and replace the damaged , broken unserviceable abonite sheet with cable copper lugs and cleaning the same cap of DG set 160 KVA all as directed by the Engr -in-charge.
S&F in replacement of UNSV pre Lub Hyd lift pump VIC for 160 KVA and taking down the same complete all as specified and directed
S&F in replacement Diesel oil gauge 500 KVA complete all as specified and directed
S&F in replacement 12 Volt 150 AH battery with 24 plates , liquid immersed and fully charged complete all as specified and directed
S&F in replacement sealed maininance free DG set starting battery including ultra plus with SMPS charger of capacity 24 Volt 32 AH battery with 24 plates , fully charged complete all as specified and directed
S&F in replacement of cada pinion ( gear wheel) and strip opening of close body alternator from the 160 KVA generator and unscrew the alternator from the DG set taking out broken gear wheel with OD ring and replacement with new and replacement worn out bush con rod small end from connecting rod and press fitting new con rod bush and reaming to size of gudgeon pin complete all as specified and directed
S&F in replacement of broken canopy door lock 04 Nos and hinged - 04 Nos of silent proof DG set 25 to 163 KVA. Hinged fitted by welded by gas welded and lock by screw complete all as specified and directed by Engr-in -charge
S&F in replacement of UNSV radiator for 160 KVA Gen set and taking down the same complete all as specified and directed
S&F in replacement of UNSV radiator for 500 KVA Gen set and taking down the same complete all as specified and directed
S&F in replacement of UNSV diode for 500 KVA Gen set and taking down the same complete all as specified and directed
Repair to burnt out alternator of capacity 75/ 160 KVA DG set and carry out the following works complete all as specified and directed by Engr-in -charge (a) Taking out alternator from the generator and disconnecting all electric connections, removing from site to workshop for repair work and back to site after repair and making all electrical connection and testing (b) Opening the top cover of alternator and dismantling of cover and taking out burnt coils from the rotor, cleaning , decorbonate the rotor slots and replacing with new coils same after repairing/replacement making all electrical connections providing sundry items and reassembling after repair to entire satisfaction of Engr-in-Charge (c) M&L for rewinding the alternator with super enameled copper winding wire of appropriate gauge alongwith allied material , including provision of cotton tape, glass sleeves insulation paper and insulating with varnish. (d) Replacement to field coil and armature (e) Replacement of rectifire, sleep ring and exiter coil (f) Replacement of damaged unserviceable coil slot (g) Making connection , checking testing and commissioning of alternater after repair and making alignment .
S & F in replacement old unserviceable water body of 160 KVA DG set and before taking down un screw the ,fan, fan belt, hose pipe and remove the its position and replacement new water body as per sample complete all as specified and directed
S&F in replacement of AVAR for 160 KVA DG set as per sample complete all as specified and directed
S&F in repair replacement 500 KVA DG Set controller display for multiple unit operation -plastic housing with display and all seting switches / on off switch /alarm indication LED including all accessories complete all as specified and directed
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at Baknaur comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units. (b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc. (c) All wiring & cable connections (d) Lead acid battery 12V/9AH Capacity. (e) 100 HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) Testing of Electrical control panel of Fire Fighting System Water Pumps. (g) Testing of Pressure switch & Pressure Guage. (h) Testing of all Sluice Valve, NRV & Air Release Valve. P.M. (j) 15 HP Jocky fire hydrent pump and 05 Hp monoblock pump servicing and testing .
Replacement of manual call point suitable for addressable system duly painted in red colour paint with front glass (to be broken in case of fire ) complete with test key to check the response with out breaking the glass and die cast aluminum housing with IFD indicator complete all as specified and directed Make:- GURUTRONIC or equivalent as approved by GE.
S&F in replacement transformer AC/DC for fire alarm system panel of electronic type complete all as specified and directed
S&F in replacement battery duly charged 12 V, 7.2 AH. Make: EXIDE or as per exixting make at site complete all as specified and directed
S&F in replacement Manual Call point complete all as specified and directed Make : GURUTRONIC or equivalent as approved by GE.
S&F in replacement electronic hooters. complete all as specified and directed Make : GURUTRONIC or equivalent as approved by GE.
S&F in replacement Addressable type Smoke / Heat detector. complete all as specified and directed Make : APOLLO / MORLEY or equivalent as approved by GE.
S&F in replacement hydrant valve wheel complete incl all necessary fixtures and fittings as reqd.complete all as specified and directed
S&F in replacement hydrant gun metal female coupling 63 mm dia at site complete all as specified and directed
S&F in replacement brass lock pin (lugs) for 63 mm dia at site complete all as specified and directed directed
S&F in replacement hydrant valve spindle 80 mm dia at site complete all as specified and directed
S&F in replacement 100 mm sluice valve wheel complete all as specified and directed
S&F in replacementFactory fabricated MS fire cabinet box as per give design made out flat CRCA of appropriate size and thickness all as directed including two coat of powder coated approved colour synthetic enamel paint over a coat of red oxide primer & fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle complete all as specified & directed by Engineer-in-Charge.
S&F in replacement canvas fire hose 63mm dia bore 30metre long confirming to IS Having male/female brass coupling both end complete all as specified and directed
S&F in replacement brass Nozzle 25 mm bore suitable for 63mm dia canvas pipe complete all as specified and directed
S&F in replacement Gun metal double acting fire hydrant valve of size 100 x 65mm conforming to IS – 5290/71 with all fitments such as cap cover instantaneous coupler for making flanged joint 100mm dia bore.complete all as specified and directed
Removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfaces of any description over applying two coats of synthetic enameled paint over a coat of red oxide primer on fire pump fire valve pit / fire fighting cubical box fitted inside bldg on each floor.complete all as specified and directed
S&F in replacement, installation, testing & commissioning of Micro processor based 2 wire fault tolerant loop, required loop networkable type 5 Loop (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output. The Panel shall support 24 zones Addressable 2 way Talk Back fire fighter communication, in case of emergency. The panel shall have ability to get integrated with PA System for zone wise annoucements. The panel shall support both Loop Powered & conventional Notification devices for emergency responses. the Panel shall support Auto learn feature. The panel should support networking upto 99 panels with maximum distance of 12 Km between 1 & last & 1.5 KM between adjacent panels on RS485. Tha Panel shall support IP connectivity if requred to connect on LAN or WAN network. the panel shall support BMS connectivity through Bacnet/Modbus moduels. The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have 24 Zones with Individual LEd Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/ LPCB/ VDS/ UL/BSA complete all as specified and directed by Engineer-in-Charge, Voice Alarm controller with USB, MP3, AM/FM player )with 1000 watts Power Amplifier. Make :- Cease fire / Apollo / Hardik Engineer / Gurutronic
Supply and fixing in replacement Gun metal fire hydrant single acting of size 80 x 63mm for stand post. complete all as specified and directed
S&F replacement sluice valve, 100 mm size, both ends flayed with high tensile brass spindle,cast iron body, as per IS-14826 & ISI Marked,PN-1.6 pressure rating including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified and directed
Rewinding of electrical induction motor up to 15HP capacity 3 phase 415 V of terrace booster pump of high rise bldg, including rewinding of the motor by proper gauge of copper wire with class E insulation with Varnishing, heating and re-assembling and testing at the site. complete all as specified and directed
Repair of 55 KW pump and disconnecting the electric connection from motor terminal box including insulating the ends of the cable, taking out the pump set of any make from pump houses after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gasket, assembling the pump with replacement of pulley, gland packing, greasing, transporting back to pump house and refixing on the existing foundation, connecting the electrilc connection to the motror and testing complete to entire satisfaction of Engineer-in-Charge .
Repair/maintenance of booster pump capacity upto 15 HP including necessary replacement of shaft impeller, bearings gun metal bush and coupling etc. complete all as specified and directed
Taking down old unserviceable motor starter . Supply and fixing in Replacement of electrical motors star delta starter fully automatic with inclosure and on off button of capacity 100 HP motor complete all as specified and directed
Taking down old unserviceable motor starter . Supply and fixing in Replacement of electrical motors star delta starter fully automatic with inclosure and on off button with slector switch, voltmeter and Amp meter indicating lamp with seletftor switch, voltage 415 Volt, Relay 24 Amp to 39 amps Coil 350 to 415 Volt of capacity 30 HP motor complete all as specified and directed
Cleaning and painting external surface with cement based paint / distemper complete, colour as existing over head RCC tank of cap 01 lakh to 02 lakh ltrs after draining out scrapping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying one coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface complete all as specified and directed
Cleaning of fire fighting over head tank and painting external surface with black colour paint / destemper complete, colour as existing Semi under ground RCC sump of cap 01 lakh to 02 lakh ltrs after draining out scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface complete all as specified and directed
Repair/ maintenance parts of high galvanised mast 15mtr long suitable for 6 to 9 lanterns symmetrically fitted alongwith their control gear boxes with 2 pointed suspension system with SS wire rope of 6 mm dia and double drum winch including lantern carriage, lightning arrester finial, pulley assembly and oiling , greasing in all parts and Major parts will be paid separately complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable LED flood light . Supply and fixing Gesto metal 200 Watt LED flood light IP 66 water proof LED light with 120 digree wide beam reflector and LED Halogen light focus light cool white including suitable control gear wired with 3 core multistranded copper cable ,connetor block .complete all as specified and directed
Taking down old unserviceable main steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin and supply and fix new main steel wire rope 06 mm dia, ungalvanised, 08/19 construction in and including necessary connection with gear pully and light pully with clamps, nut, bolts and washers etc and old rope taking down with the help of high boom crane complete all as directed by Engineer-in-Charge.
Taking down unserviceable/ burnt high mast light motor from the winch ( gear box ) and Rewinding of electrical motor 03HP capacity 3 phase 415 V , including rewinding of the motor by proper gauge of copper wire with class E insulation with Varnishing, heating and re-assembling and testing at the site directed by Engr -in -charge .
R. P. Suppliers and Construction Co. (BID ID -3291293)
SWAMI ENGINEERS (BID ID -3289787)
M/S Sonu Traders (BID ID -3287712)
Esha Engineers (BID ID -3286480)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .