Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 CrAccepted-AOC | ₹31.3 Cr | L1 | Accepted-AOC Amended Lump sum after deduction of amount of credit |
| 2 | L2₹32.2 CrRejected-Finance | ₹32.2 Cr | L2 | Rejected-Finance Other that lowest Bidder |
| 3 | L3₹32.4 CrRejected-Finance | ₹32.4 Cr | L3 | Rejected-Finance Other that lowest Bidder |
| 4 | L4₹32.5 CrRejected-Finance | ₹32.5 Cr | L4 | Rejected-Finance Other that lowest Bidder |
| 5 | L5₹33.5 CrRejected-Finance | ₹33.5 Cr | L5 | Rejected-Finance Other that lowest Bidder |
Tender Value
₹31.5 Cr
EMD Value
₹15 L
Closing Date
24 Jul 2020, 6:00 pmClosed
CE Navy Visakhapatnam
Chief Engineer Navy Military Engineer Services Station Road Visakhapatnam 530 004
CONSTRUCTION OF PROJECT D TRAINING INFRASTRUCTURE AT VISAKHAPATNAM
2020_MES_338871_1
CE Navy / VIZ / Token / 17 of 2019-2020
Open Tender
Civil Works
730 days
Visakhapatnam
As per NIT
8 documents required · 8 mandatory
₹3,000
GE P Navy Visakhapatnam
₹15 L
Yes
CE Navy Visakhapatnam
7 Sept 2020
15 Apr 2020
25 Jul 2020
15 Apr 2020
24 Jul 2020
2 Jul 2020
8 May 2020
Amount
Schedule "A" Part – I to Schedule "A" Part – XVI: NOTE: Schedule "A" Part – I to Part – XVI are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "Buildings & Structures", as listed in Schedule "A" Part – I on Serial Page No. 40[R].
Lumpsum price worked out by the contractor for "Site Clearance / Area Development / Earthwork Excavation", as listed in Schedule "A" Part – II on Serial Page No. 42[R].
Lumpsum price worked out by the contractor for "Pile foundation", as listed in Schedule "A" Part – III on Serial Page No. 43[R].
Lumpsum price worked out by the contractor for "Security wall / fencing", as listed in Schedule "A" Part – IV on Serial Page No. 45[R].
Lumpsum price worked out by the contractor for "Road/ Culvert", as listed in Schedule "A" Part – V on Serial Page No. 46[R].
Lumpsum price worked out by the contractor for "Area Drainage", as listed in Schedule "A" Part – VI on Serial Page No. 47[R].
Lumpsum price worked out by the contractor for "Sewage Disposal", as listed in Schedule "A" Part – VII on Serial Page No. 49.
Lumpsum price worked out by the contractor for "Rain Water Harvesting", as listed in Schedule "A" Part – VIII on Serial Page No. 50.
Lumpsum price worked out by the contractor for "Internal Water Supply", as listed in Schedule "A" Part – IX on Serial Page No. 52.
Lumpsum price worked out by the contractor for "Internal Electrification", as listed in Schedule "A" Part – X on Serial Page No. 54[R].
Lumpsum price worked out by the contractor for "External Water Supply", as listed in Schedule "A" Part – XI on Serial Page No. 55.
Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – XII on Serial Page No. 58.
Lumpsum price worked out by the contractor for "Lightening Protection", as listed in Schedule "A" Part – XIII on Serial Page No. 59.
Lumpsum price worked out by the contractor for "Fire Fighting System", as listed in Schedule "A" Part – XIV on Serial Page No. 62[R].
Lumpsum price worked out by the contractor for "Fire Alarm System", as listed in Schedule "A" Part – XV on Serial Page No. 63.
Lumpsum price worked out by the contractor for "Demolition", as listed in Schedule "A" Part – XVI on Serial Page No. 64.
Schedule "A" Part - XVII: [Miscellaneous Items] [Pile foundation, Security wall, Internal Water Supply, External Water Supply, Internal Electrification, External Electrification, Lightning Protection, Fire Fighting System, Fire Alarm System, Rain water harvesting, DG Set, Arboriculture, Air Conditioning, ,Aviation lights and Arboriculture]:
All as per Serial Item No. 17 above but One call bell point controlled by one bellpush
All as per Serial Item No. 17 above but One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
All as per item No.17 here-in-before but controlled by two two way switches complete all as specefied and directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and pressed GI modular box of 2.0 mm thick and suitable size as required at site and suitable for modular brackets for fixing switches sockets, etc concealed in walls, including 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One 3/5 pin 15 Amp socket outlet point controlled by one modular switch of 15/16 Amp as directed on independent board.
Supply and Fix Energy efficient LED Tube Light fitting 1 x 18/20 W attractive wall / ceiling mounted type with metalic channel and white reflactor complete with all accessories including electronic driver pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and fixing arrangement complete all as specified and directed.(Make - CG cat No:LCTL-18-CDL or equivallent in Havells/ Bajaj/Philips)
Supply and Fix Energy efficient LED Tube Light fitting 1 x 36 W attractive wall / ceiling mounted type with metalic channel and white reflactor complete with all accessories including electronic driver pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and fixing arrangement complete all as specified and directed.(Make - CG cat No:LDL-36-CDL or equivallent in Havells/ Bajaj/Philips)
Supply and Fix Energy efficient LED mirror light fitting 1 x 07 W attractive wall mounted type (2 ft long) complete with all accessories including electronic driver pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and fixing arrangement complete all as specified and directed(Make - CG cat No:LCL-07-CDL or equivallent in Havells/ Bajaj/Philips)
Supply and Fix LED light fitting of 1 x 12 W surface/ceilling mounted type round profile complete with all accessories including electronic driver pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and fixing arrangement complete all as specified and directed(Make - CG cat No:LCSR-12-CDL or equivallent in Havells/ Bajaj/Philips)
Supply and Fix LED light fitting of 1 x 34/36 W recessed mounted type square profile(2 ft x 2 ft) complete with all accessories including integral electronic driver pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and fixing arrangement complete all as specified and directed(Make - CG cat No:LCPL-36-CDL(2X2) or equivallent in Havells/ Bajaj/Philips)
Supply and Fix LED security light fitting of 1 x 25 W complete with all accessories including integral electronic driver pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete with GI bracket and fixing arrangement all as specified and directed ((Make - CG cat No:LSTS-25-CDL or equivallent in Havells/ Bajaj/Philips)
Supply and Fix ceiling fan 1200 mm sweep complete AC single phase 230 Volt 50 HZ ,5 star rated,connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to ceiling fan including all hanging arrangement complete all as specified and as directed. (Make - Havells/ Bajaj/CG)
Supply and Fix exhaust fan 250 mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening,fixing and making good the distrubered surfaces etc complete all as spcified and as directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth GI wire of 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel using galvanised iron strip GI wir of 4.0 mm and 15 mm dia light grade GI pipe upto test point or 7.5 mtr and GI pipe 20 mm medium grade for watering pipe as earthing leadall as shown in electrical plate No. 03 connected to earthing test point all as specified or indicated including testing on completion. all as specified and as directed.
Supply and fix MCB single pole & neutral 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size but not less than 25mm dia of copper lugs complete all as specified as directed
Supply and Fix MCB single pole 6 to 32 amps, 240 volts, 10 KA, 'B' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed Note:(i) Cost of copper lugs shall be included in the unit rate.
Matetial and labour for providing sub-main wiring with 6.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 6.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed. Note :(i) Two run of 6.0 Sqmm + one run of 6.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
Matetial and labour for providing sub-main wiring with 4.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size but not less than 20mm dia complete all as specified and as directed. Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
Matetial and labour for providing sub-main wiring with 10.0 sqmm nominal area 10 single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including two 10.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size but not less than 32 mm dia complete all as specified and as directed. Note :(i) Four run of 10.0 Sqmm + one run of 10.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
Supply and fix telephone sockets(Jack type) RJ 11-1 with shutter 1 module complete complete with all acessories all as directed.
Supply and fix TV co-axial socket 1 module complete with all acessories all as directed.
Supply and fix 15mm bore fancy type chromium plated bib tap cast copper alloy with two ways bib tap with wall flange screwed for iron pipe or brass ferrule complete all as specified and as directed.
Supply and fix fancy type health faucet 15mm dia upto 1 mtr long 1st quality including CP bracket all as per manufacturers instructions and as directed.
Boring for bored cast in situ piles 600mm dia in any type of soil/clay except Soft disintigrated rock and hard rock/fractured rock and getting out and disposal of spoil to a distance not exceeding 05KM out side MD land using hydraulic system boring method complete all as specified and directed.
Boring for bored cast in situ piles 600mm dia in Soft disintigrated rock and hard rock/fractured rock and getting out and disposal of spoil to a distance not exceeding 05KM out side MD land using hydraulic rig method complete all as specified and directed.
Carrying out Initial load test on 600mm dia piles all as per IS - 2911 Part - IV complete all as directed.
Carrying out routine load test on 600mm dia piles all as per IS - 2911 Part - IV complete all as directed.
Carrying out initial pullout test on 600mm dia piles all as per IS - 2911 Part - IV complete all as directed.
Carrying out initial lateral test on 600mm dia piles all as per IS - 2911 Part - IV complete all as directed.
Carrying out low strain integrity test on 600mm dia piles including analysing the results as perASTM D 5882 complete all as directed.
Boring of holes under road, pavements, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure complete all as directed.
M&L for applying two coats of weather proof exterior emulsion paint over a coat of primer( for compound wall only) .
M&L for supply and spreading stone dust in layers n.exc 25cm watering and ramming as in foundations complete all as directed.
M&L for non woven polypropylene Geotextile of having minimum weight 285 Grams per Sqm confirming to clause 702, table 700-5 of MORTH 5th revision as in foundations all as specified as directed and as shown in drawings.
M&L for preparation of new plastered wall surfaces and applying two coats of weather proof exterior emulsion paint over a coat of primer complete all as specified.
Supply and platation of Korean grass including cow dung, pesticides,vermicompost and water etc., complete all as directed by Engineer-in-Charge.
Supply and plantation of crotons and hedges (Ht 30 cm @ 30 cm c/c)including cow dung, pesticides,vermicompost and water etc, complete all as directed by Engr-in Charge.
Masonry valve chamber of size 750 x 750 x 750mm comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as specified and as directed.
Cutting existing steel tubing for alterations or additions necessarily done in position without taking down and inserting Tee of 100x100x80 mm a for tapping all as specified and as directed.
Supply and fix Integral LED street light Luminaire 72 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket of 1.5 Mtr length, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testingall as directed. Make:- CG cat part No. LSTP-72-CDL or eqvellent of Model in Philips/ Havells/Bajaj
Supply and Fix loop in Loop out thermosplastic cable junction boxes of size 250 x 250 x 100 mm made out of 1.6 mm thick MS Sheet comprising with MCB SP 4 A and 4 Porcelain terminals as bus terminals for cable with necessary fixing arrangemets with cable glands, etc preparing the surface and appling two coats of synetic enamel paint over a coat of primer etc all as specified and as directed. Make: Hensel/Sintex
Supply and fix compact type timer panel of capacity 6 KW including of Power contactor of 32 A TP,MCB 40 Amp TP and Digital Timer switch 415 V,including steel encloser all as directed. (Make:Havell's Cat No:IHXTS03060 or equivallent in Standard/Indoasian)
Supply and fix wall mounted/ floor mounted,double door ,4 pole ACB 4 Pole, 415 V,50 KA(ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 800 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes, with Encloser made up of CRCA sheet of 2 mm thick front door operated, weather and water proof with necessary locking arrangements along with lugs, cable glands of suitable size for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting cables and the nuts/ bolts etc used are to be made of rust proof material complete with powder coating, necessary internal electric connection as required with LED indicating lamps for each phase all as directed.(to be fixed in Substation of SAU)
LT Panel board made out of CRCA sheet 3.15 mm thick Outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Aluminium bus bar of 1200 Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V complete with powder coating, necessary internal electric connection as required and provision of the following: ( Near building)
INCOMER [a] ACB 4 Pole, 415 V,50 KA(ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 800 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 No. Make:Legrand /Simens/GE b) CBCT c) Earth leakage relay d) Over voltage and under voltage relay e) Phase indicating LED lamps. (RYB) f) Control fuse base with 2 Amps HRC linc g) 6 stage APFC relay h) timer i) Aux contractor j) Exhaust fan OUTGOING [i] ACB , 4 pole, 415V, 50Ka(ICS=ICU=ICW for 1 Sec) with microprocessor release(EDO type) of capacity 630A with adjustable type over load protection, short cicuit protectionwith inbuilt display for 20 faults history current parametres andnecessary CTs, metres,cable and boxes - 01 No. [ii] MCCB AC 3 Phase 415V, 50Hz, 4 pole, 315A capacity 36Ka(ICS=ICU 100%) microprocessor release with in built relay with adjustable type thermal and magnatic setting release - 01 No a) (50 x 3), (25 x 1), (12.5 x 2) KVAR Capacitor bank. b) MCCB 400 Amps 4 pole, 36 KA c) Suitable KVAR MPP heavy duty capacitor cylinder type, 415 Volts. d) Suitable KVAR Capacitor duty contractor e) Indicating LED lamp. (ON/OFF) f) Push button. (Start/ Stop) g) Control fuse base with 2 Amps HRC link.
LT Panel board made out of CRCA sheet 2.0 mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Aluminium bus bar of 300 Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V complete with powder coating, necessary internal electric connection as required and provision of the following: (LT panel near bldg)
INCOMER a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 315 A capactiy 36kA(ICS=ICU 100%) microprocessor relese with inbuilt relay with adjustable type thermal and magnetic setting release - 01 No. Make:Legrand /Simens /GE OUTGOING b) LT 440 volts 3 phase, 4 wire 50 cycles, 25 kA, Adjustable type MCCB of 160 Amp rated complete with overload protection, no-volt thermal based release.- 04 Nos. ( 01 for bldg light load,02 for 60 KVA UPS and one for spare) Make:Legrand /Simens /GE c) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 40 Amp rated complete with overload protection, no-volt thermal based release.- 04 Nos. ( 03 Nos for lift and one for spare) Make:Legrand /Simens /GE d) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 32 Amp rated complete with overload protection, no-volt thermal based release. - 02Nos (one street light and one for spare) Make:Legrand /Simens /GE e) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases -03 sets f) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power, energy, THD along with connected CTs Make: Schinder / L&T.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32x6mm thick GI strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Material and Laboure for laying of Ductile Iron pipe with double flanged centrifugally cast(spun) class K-9 of 150mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning (For external Ring main and upto Bldg) all as specified and as directed.
Material and Labour ductile iron fittings such as Bends, Tapers, Tee pieces(single & double branch any type and angle/radious and straight connecting pieces complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip 25x4 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover of 10 mm thick with MS rod 6mm dia 150mm long reinforcement, watering funnel with 15 mm dia light grade for watering and for protection of earth electrode 32 mm dia GI pipe all as specified and directed and tested on completion.
Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and as directeed.
Supply and fix GI cable tray with cover for fixing XLPE cable from duty room to terrace for siren and at various places to accommodate the cables for MCPs, panel etc of size not less than 75x38 mm with necessary bends,angles,supports for fixing,etc all as specified and as directed
f) Aluminium chequered plate (3 mm thick) as flooring joint in chequered palte should not more than one and top covering with granite flooring complete. g) Non stop button / independent operation. h) Over load warning indicator both audio and visual type with tripping sustem having relays etc (overload protectin / tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be conformity with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish. l) Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS. m) Mirror of 4 mm thickness of suitable size as specified. n) Blank o) Specification plate with complete details . p) Contineuos earthing for machine and equipments. q) Steel wire rope of adequate sixze as per relevant IS and as per manufacturerer specifications. r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete.
s) Full length display indicator panle. t) Main drives and control shall be of latest, high effective and low power consumption. u) Suitable phase reversal relay shall be provided on the controller to protect lift / equipment against phase reversal, phase failure and low voltage. v) Intercom shall be connected with nearest security post.
Supply, install, testing & commissioning goods lift,2000 Kg , 0.5 metre/sec with single speed motor ,415 volts, 3 phase AC 50 Hz supply conforming to IS-14665 and as amended,suitable to serve G+5 upper floors with AC Variable Voltage & Variable frequency Drive (AC VVVF) complete with all standard accessories,with suitable motor and gear less unit simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door &built in announcing system without hand set (03 Nos ,one each in car,Machine room & near Ground floor landing door) complete all as specified and as directed including comprising of the follwings:- (a) Fire man switch (b) Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity of battery designed for funnign the lift with full load. c) Battery operated emergency light (Led ceiling fitting), alarm (speaker for emergency alarm sustem to be fixed) and stop button in car with rechargeable arrangement for battery. d) Four sleek circular 5 Watt LED light fitting in false ceiling .
e) One Sleek circular PVC heavy duty fan in false ceiling. Make for(c) & (d) : Philips / Bajaj / Havells / Crompton Greaves. f) Aluminium chequered plate (3 mm thick) as flooring joint in chequered palte should not more than one and top covering with PVC flooring complete. g) Non stop button / independent operation. h) Over load warning indicator both audio and visual type with tripping sustem having relays etc (overload protectin / tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be conformity with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish. l) Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS. m) Mirror of 4 mm thickness of suitable size as specified. n) Blank o) Specification plate with complete details . p) Contineuos earthing for machine and equipments. q) Steel wire rope of adequate sixze as per relevant IS and as per manufacturerer specifications. r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete.
s) Full length display indicator panle. t) Main drives and control shall be of latest, high effective and low power consumption. u) Suitable phase reversal relay shall be provided on the controller to protect lift / equipment against phase reversal, phase failure and low voltage. v) Intercome be connected with nearest security post.
Supply and fix of IP Energizer with CE marking conform to IEC 60335-2-76, IEC 61000-3-2, IEC 61000-3-3 and IS 8437 standards with onboard LCD, Keypad, inbuilt Alarm unit, network control, seperate inbuilt compartment for battery and charger including necessary connecting up controlling wire, complete all as specified and directed.
Supply and fix Live lite with one side visibility and atleast 7 Nos. of Super bright LEDs emitting white color powered working on Fence voltage and flashing at every pulse generated by Energizer complete with necessary connecting up, complete all as specified and directed.
Supply and fix Hooter operate at 12V DC consuming less than 500 mA having not less than 100 dB output, ABS body, Mounting bracket & hardware, Operating temperature range -10 deg C to 50 deg C complete all as specified and directed.
Supply and fix Solar PV module of rating 12V / 74 Wp complete all as specified and directed.
Supply and fix Solar PV module stand of 50 NB Class b GI pipe of 12 feet length complete all as specified and directed.
Supply and fix 12V / 65 AH Maintenance free / dry battery with terminal lugs and gelly , complete all as specified and directed.
Supply and fix Lightening diverter kit complete with necessary connecting up and SS componentshaving provision to alter the air gap complete all as specified and directed.
Supply and fix Out door type console rack made CRCA sheet of size 760mm x 760mm x 300mm or better to suit requirements made of sheet steel surface finish enclosure and door dipcoat-primed, powder- coated complete all as specified and directed.
Supply and fix Intermediate post assembly (Wall top): 1.6mm x 50mm x 30mm thick MS pre- fabricated V shaped KIWITAH post duly galvanised of 1.5 metre length with 8mm dia grouting rods suitable for fixing on wall with 0.3 metre of it grouted into the wall complete civil works like PCC etc, including post erection and 12 nos. of Polypropelene anti-climbing insulators with locking pin having > 15KV di-electric strength, breakload of about 25 KG, UV stabilized complete all as specified and directed.
Supply and fix End / Start post assembly (Wall top): 2mm thick MS prefabricated 40mm square pipe of 1.5 metre with 25NB 2mm thick support post with 0.3 metre of it grouted into the wall and having 12 nos. of UV stabilized & >15 KV di-electric strength Strain insulators made of virgin Nylon with stainless steel Hooks of 6mm dia moulded in the shape of 'S' for fixing strain insulators complete all as specified and directed
Supply and fix Corner post assembly (Wall top): 2mm thick MS prefabricated 40mm square pipe of 1.5 metre with 2 nos. of 25NB 2mm thick support post with 0.3 metre of it grouted into the wall and having 24 nos. of UV stabilized & >15 KV dielectric strength Strain insulators made of virgin Nylon with stainless steel Hooks of 6mm dia moulded in the shape of 'S' for fixing strain insulators complete all as specified and directed.
Supply and fix GI wire tightner LM6 grade for tightening of power fence dimension of about 116mm x 32mm x 30mm x withlocking mechanism and capable of tightning a maximum of 5mm dia wire including fixing with provision of suitable fixing material, complete all as specified and directed.
Supply and fix Galvanised MS joint clamps for power fence including SS bolt and nut mechanism to connect two wires having maximum diameter of 3 mm complete with fixing arrangement, complete all as specified and directed.
Supply and fix HT Fencing wire of 2.59 mm dia having >130 Kg/sq. mm UTS, 230 grams/sq .m, zinc coating, in compliancce with IS : 4826 complete all as specified and directed.
Supply and fix PVC double insulated GI wire 2mm dia, out door of cable 9mm for more than 15KV break down Voltage including 25mm dia HDPE conduit and clamps for fixing complete all as specified and directed.
Supply and fix Warning sign board of 247mm x 147mm x3mm polypropelene material with caution sign as per IEC 60335-2-76 standard having yellow background & black / red letters with size of about 10mm in English / Hindi with fixing mechanism and placed at every 10 meter distance on Fence complete all as specified and directed.
Earthing with stainless steel rod of 8mm dia of 1.2 metre length with suitable GI clamps for connecting cable, adequate quantity of charcoal and salt to reduce earth resistivity to less than 3 Ohm covered by chamber and earth plate. 2 nos for every Energizer and also at every 50 meter distance along fence complete all as specified and directed.
Supply and fix PC desk top 1TB hard disk, 4 GB RAM, minimum 13, third generation processor with 22" (558.80mm) LED monitor complete with installed Fence software including required software and graphics card. Software features shall include view & control all perimerer Energizers, Graphical display of site layout on screen with zone indications and LIVE status, Zone violation indication, Control on schedule User authentication, Client server archietecture, Event logging, Screen lock, Display of Fence voltage, Battery voltage on screen etc., complete all as specified and directed.
Supply and fix 500VA UPS with minimum 30 min back up for Field control Unit complete all as specified and directed.
Supply and fix 3 core 2.5 sq.mm armoured PVC sheathed copper conductor power cable, with 25 mm dia HDPE conduit, excavation of 600 mm depth and 300 mm widetrench and cable laid in excavated trenche with glands, clamps & lugs for incoming & outgoing connection, complete all as specified and directed.
Supply and fix Cat-6, 4P, UTP, Mechanical Conductor Size - 23 AWG, Primary Insulation: Polyolefin, Nominal O.D: 1.0mm, Sheath Type : PVC Minimal Wall : 0.42mm, along with 25mm dia HDPE conduit necessary accessories as required complete all as specified and directed.
Supply and fix UPS 1KVA with 1 hour backup for PC including battery bank, stand, connecting lead, output power capacity 800 Watts / 1.0 KVA, Output Voltage configurable for 220,230 or 240 nominal output voltage; Efficiency at Full Load 88.0%, Load Crest Factor 3:1 , Input frequency 47 - 63HZ, Batteries as required for Backup complete all as specified and directed.
(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under i)Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System :Lubricating oil filter,Lubricating oil pump vi) Air Intake System :Air intake Manifold Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator
ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display. xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms xv) Fuel Tank :- Additional Fuel Tank of capcaity to suit Daily service fuel tank made out of 3mm thick (10G) HR sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the accoustic enclosure.
xvi) MS pipe line to and from the fuel tank to the DG Set C) AMF Panel :- Factory made outdoor type control cubical made out of CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 500 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole ACB/MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standardstandard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc g) Annuciation with indication lamps for : (i) Low lub oil pressure. Controls :- a) Load on Indication b) Load off indication c) Engine start push button d) Engine stop push button e) Fault accept / reset push button f) Battary Charger : (i) Transformer (ii) Rectifier
E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 5.50 x 2. 4 x 0.8 m for placing of DG Set complete all as specified and directed. Make : (a) Engine : Greaves Cotton/ Kirlosker Green/ Cummins/ Sterling Generators Pvt Ltd/. (b) Alternator : Crompton Greaves/ Alstom/ Kirlosker Electric/ Siemens.
All as per serial item No.92 above but DG set of capacity 160 KVA with outdoor type AMF panel all as specified and as directed (For Bldg Load)
Supply and fix stainless steel water cooler electric driven (single phase), having approx storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour all as specified and as directed.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 kVA all as specified and as directed.
Supply ,installation,testing and commissioning of IGBT based 3 phase input 3 phase output ON-LINE UPS with Built-in-Isolation Transformer and SMF batteries (12 V,75 AH x 60 Nos)to provide 30 min back up time of Capacity 60 KVA including all acessories for batery storage all as specified and as directed. Make:Numeric of Legrand.
Supply and fix aviation obstruction light LED type filament-less bulb with 10 Watt bulb complete including standard fixing arrangements all as specified and as directed.
Supply and fix cable PVC insulated armd PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor, fixed to wall /roof etc with suitable calmps spacers bolts nuts etc. all as specified and as directed
Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure all as directed.
Supply and fix rigid non-metallic PVC conduit of size 25 mm dia inclusive of boxes (junction/terminal) alongwith all tees, bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks etc concealed in wall or clamped on wall including GI puling wire for LAN/Telephone cable of suitable size all as specified and as directed.
PHASE – II: SCHEDULE "A" PART – XVIII: CENTRAL AIR CONDITIONING WORKS INCLUDING SUPPLY, INSTALLATION, TESTING & COMMISSIONING [INCLUDING PHASE – I & PHASE – II PERFORMANCE TESTS]:
Supply, installation, testing and commissioning of Screw-type Chiller with actual capacity not less than 150 TR, suitable for ambient conditions, with AHRI certification all as specified hereinafter.
[i] Supply, installation, testing and commissioning of floor-mounted compact screw-type chiller machine complete with semi-hermatic twin screw type compressors with independent circuits, water-cooled S/T type condenser, S/T horizontal flooded type evaporator with carbon steel shell and seamless copper tubes with 19 mm nitrile rubber insulation, common base frame, interconnected copper refrigerant piping and wiring, vibration isolators, gauge panel, automatic safety controls, flow switch at evaporator and condenser and ozone friendly CFC-free refrigerant gas R-134a/407C. The refrigerant flow control shall use an electronic expansion valve. The chiller shall be designed for a working pressure of 150 psig and hydraulically tested at 225 psig. A number of properly spaced baffles shall be provided for maintaining optimum water velocity and heat transfer and the tubes shall be adequately supported.
Chillers shall be factory AHRI tested at design conditions at 100%, 75%, 50% and 25% load respectively; test certificates shall be produced for all three chillers. The chiller shall be BMS compatible and shall have RS485/RS232 serial communication protocol; the motor shall be suitable for 3- Phase, 415 V ± 10%, 50 Hz AC electric supply; electric panel shall have an IP 54 rating, as per specification and drawings. The chiller shall be as per the approved particular technical specifications and shall meet the following design criteria: [a] Chiller [i] Chilled Water IN: 54° F [ii] Chilled Water OUT: 44° F [iii] Fouling Factor: 0.0005 (in FPS units) [iv] Water Flow Rate: 2.67 USgpm/TR [b] Condenser [i] Condenser Water IN: 90° F [ii] Condenser Water OUT: 100° F [iii] Fouling Factor: 0.001 (in FPS units) [iv] Water Flow Rate: 4.25 USgpm/TR [c] Minimum COP (at ARI conditions): 4.15 NOTE : Necessary civil work viz. PCC foundation for placement of chillers shall be covered in the scope of work
Horizontal End Suction Long Coupled type pump with insulation suitable for 360 USgpm water flow rate and 35 m head all as specified hereinafter.
Supply, installation, testing and commissioning of end-suction & top-discharge, non-self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage high efficiency induction motor, star/delta starter panel, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting, elastomeric thermal insulation of suitable thickness, etc. suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply. (2 W + 1 S) as per specification and drawings NOTE :Necessary civil work viz. PCC foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be covered in the scope of work. The pump shall be as per the approved particular technical specifications.
FRP Bottle shape induced draught cooling tower Capacity : 660 usgpm, for 165 TR water-cooled screw type chiller all as specified hereinafter.
Supply, installation, testing and commissioning of FRP rectangular shape vertical induced draught counter flow cooling tower with uniform water distribution and optimal heat transfer, havingtough fiberglass reinforced plastic(FRP) casing of sufficient structural strength to withstand vibrations and wind velocity upto 60m/sec, FRP basin, rigid honeycomb type PVC fill of suitable thickness , SS sprinklers and nonclogging sprinkler pipes, FRP drift eliminator, energy efficient induced draught axial type fans with factory set and dynamically balanced blades pitch,TEFC squirrel cage high efficiency induction motor with IP 65 protection suitable for 3 phase, 415V, 10%V, 50Hz AC electric supply, inlet, outlet, drain and over flow nozzle connections etc. NOTE : Necessary civil works Viz, PCC foundation for placement of cooling tower, etc shall be covered in the scope of work. The cooling tower shall be as per the approved particular technical specification.
Horizontal Split Casing type pump with insulation suitable for 600 USgpm water flow rate and 40 m head all as specified hereinafter.
Supply, installation, testing and commissioning of end-suction & top-discharge, non-self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage high efficiency induction motor, star/delta starter panel, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply. NOTE : Necessary civil work viz. PCC foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be covered in the scope of work. The pump shall be as per the approved particular technical specifications and drawings.
Supply, installation, testing and commissioning of double-skin type horizontal, floor-mounted, top/side discharge air handling units having corrosion resistant extruded aluminum hollow profile with thermal break, heavy gauge galvanized steel channel base frame, 43 mm double skin panel with pressure injected CFC & HCFC free PUF with 'k' value of 0.02 W/°C m & density 40 kg/cum, pre-coated pre-plasticized galvanized outer and inner skin 0.60mm thick, air-tight casing using gaskets and self-adhesive tapes, AMCA certified energy efficient fans with double inlet double width forward or backward curved impellers for high static pressure mounted on aluminum extruded slide rail base frame, chilled water coils with combination of 6 rows deep with anti-corrosion Aluminum fins, PVC Naylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan, 10 micron pre-filters, inspection windows/doors, mixing box and supply/return/fresh air dampers of capacity 16 TR - 8,000 CFM - Ground Floor with the following accessories.
[a] Suitable DIDW fan with AMCA certified blower having outlet velocity not exceeding 9.2 m/s [b] 4 Pole, TEFC, high efficiency, squirrel cage induction motor drive having BHP rating 20% higher than the peak capacity, suitable for 415 V ±10%, 50 Hz, 3-Phase AC power supply [c] V-belt drive assembly with pulleys, belt, guard, etc., double canvass connections with zip to discharge duct/plenum, etc. [d] 50 mm thick, washable HDPE, 90% down 10 micron pre-filters, filters, fixing framework, hinge type access doors, etc. [e] 6 row deep chilled water coil section with copper fins and copper tube tested on 21 kg/sq cm with SS sandwiched drain tray, etc. NOTE : Necessary civil work viz. PCC foundation for placement of AHU, etc. shall be covered in the scope of work. The AHU shall be as per the approved particular technical specifications and the following design criteria.
All as per serial item No.105 above but of capacity 25 TR - 12,700 CFM - First Floor .
All as per serial item No.105 above but of capacity 38 TR - 19,900 CFM - First Floor.
All as per serial item No.105 above but of capacity 23 TR - 12,000 CFM - Second Floor.
All as per serial item No.105 above but of capacity 32 TR - 17,400 CFM - Second Floor.
All as per serial item No.105 above but of capacity 25 TR -13,400 CFM - Third Floor.
All as per serial item No.105 above but of capacity 24 TR -12,400 CFM - Third Floor.
All as per serial item No.105 above but of capacity 30 TR - 15,000 CFM - FOURTH FLOOR.
All as per serial item No.105 above but of capacity 26 TR - 14,000 CFM - FOURTH FLOOR.
All as per serial item No.105 above but of capacity 17 TR - 8,400 CFM - FIFTH FLOOR.
All as per serial item No.105 above but of capacity 28 TR - 14,300 CFM - FIFTH FLOOR.
S & F HDPE chilled water makeup expansion tank of capacity 2000 liters of pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, complete with inter-connection piping, insulated with 50 mm thick insulation covered with sand cement plasterring as per specification and drawings
S & F HDPE condenser water expansion tank for cooling tower of capacity 5000 liters of pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' with interchangeable EPDM-BUTYL rubber membrane complete with inter-connection piping, etc. as per specification and drawings
Supply, installation, testing and commissioning of MS ERW Class 'B' condenser water piping of size 250 mm NB with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden/Puff blocks, etc. as specified in particular specifications and drawings.
Supply, installation, testing and commissioning of MS ERW Class 'B' condenser water piping of size 200 mm NB with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden/Puff blocks, etc. all as specified and as shown in drawings.
Supply, installation, testing and commissioning of Non chemical type on line scale preventer of size 150mm as per the capacity of the condenser water pump flow all as specified and as shown in drawings
Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve of size 150mm NB designed, manufactured and tested as per IS: 13095 (1991), suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection with accessories all as specified and as shown in drawings
Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV) of size 150mm NB, designed & tested as per IS: 5312-2 (1986), suitable to handle clear water having turbidity up to 5000 ppm, having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. with accessories all as specified and as shown in drawings
Supply, installation, testing & commissioning of Y-type strainer of size 150mm NB with CI/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection, etc. with accessories all as specified and as shown in drawings.
Supply, installation, testing and commissioning of 2-way, globe type, PN 1.6 rated, balanced/high rangeability manual balancing control valve of size 150mm NB all as specified and as shown in drawings complete as per following specification.. Nominal Pressure: PN16 Temperature: -10° C to +110° C Body Material: IS:210, FG 220 CI Stem Material: ASTM A276,GR SS 410 Disc Material: Stainless steel Disc Hand Wheel: Cast Iron Leakage Rate: No visible leakage Medium Type: Water Flange Standard: ISO7005-1 (GB/T 9113) Shell Test Pressure: 24bar Seal Test pressure: 17bar
M & L for UPVC pipes and fittings of size 40mm NB, resistant to chemical & electromechanical corrosion, conforming to EN 1452-2, having specific gravity 1.43, shore hardness 70°C to 90° C, tensile strength 500 kg/sq.cm, bending strength 950 kg/sq.cm, modulus of elasticity 3.2 X 10 kg/sq.cm and dielectric strength > 40 kV/mm complete with accessories all as specified and as shown in drawings.
Supply, installation, testing and commissioning of MS ERW Class 'B' chilled water piping of size 200mm NB with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden blocks, air-purge valves, drain-valves, etc. thermally insulated with 75 MM thick EPS Pipe Section covered with 26 G Aluminium cladding all as specified and as shown in drawings.
All as per Serial item No. 126 above but of size 150mm NB
All as per Serial item No. 126 above but of size 125mm NB
All as per Serial item No. 126 above but of size 100mm NB
All as per Serial item No. 126 above but of size 80mm NB
All as per Serial item No. 126 above but of size 65mm NB
All as per Serial item No. 126 above but of size 50mm NB
Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve of size 125mm NB designed, manufactured and tested as per IS: 13095 (1991), suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories all as specified and as shown in drawings.
All as per Serial item No. 133 above but of size 100mm NB
All as per Serial item No. 133 above but of size 80mm NB
All as per Serial item No. 133 above but of size 65mm NB
All as per Serial item No. 133 above but of size 50mm NB
Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV) of size 125mm NB, designed & tested as per IS: 5312-2 (1986), suitable to handle clear water having turbidity up to 5000 ppm, having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. with elastomeric thermal insulation of suitable thickness and accessories all as specified and as shown in drawings.
Supply, installation, testing & commissioning of Y-type strainer of size 125mm NB with CI/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessoriess all as specified and as shown in drawings.
Supply, installation, testing and commissioning of 2-way, globe type, PN 1.6 rated, balanced/high rangeability control valve of size 125mm NB all as specified and as shown in drawings complete all as per following specification. Nominal Pressure: PN16 Temperature: -10° C to +110° C Body Material: IS:210, FG 220 CI Stem Material: ASTM A276,GR SS 410 Disc Material: Stainless steel Disc Hand Wheel: Cast Iron Leakage Rate: No visible leakage Medium Type: Water Flange Standard: ISO7005-1 (GB/T 9113) Shell Test Pressure: 24bar Seal Test pressure: 17bar
All as per Serial item No. 140 above but of size 80mm NB
All as per Serial item No. 140 above but of size 65mm NB
All as per Serial item No. 140 above but of size 50mm NB
Supply, installation, testing and commissioning of CI 3-way mixing valve of size 65mm NB, suitable for operation up-to 10 bar, with electronically operated actuator for AHUs. Water flow through the valve shall be regulated by rotation of brass slipper between the main and the bypass ports; it shall be possible to manually rotate the brass slipper through 360° and interchange the main and the common ports, to facilitate installation at site. All internals of the valve shall be rust-proof and the 'O' ring shall be of elastomeric insulation. The valve actuator shall be of electronic type with DC motor, the actuator's angle of rotation shall be 90°, it shall be without any limit switches and shall be overload-proof. It shall have an indicator to indicate the position and push-button to disengage the gear train for manual operation complete with elastomeric thermal insulation of suitable thickness all as specified and as shown in drawings.
All as per Serial item No. 149 above but of size 50mm NB
All as per Serial item No. 149 above but of size 40mm NB
S & F of CL 150 rated ball valve of size 25mm NB, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories all as specified and as shown in drawings.
Supply, installation, testing and commissioning of automatic air-vent valve having 19mm end connections with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide capm etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 115° C respectively, installed on all high points in the water piping system to automatically remove the trapped air, installed on all high points in the water piping system to automatically remove the trapped air complete all as specified and as shown in drawings.
Supply, installation, testing and commissioning Temperature gauge of 100 mm dia for temperature range 0° C to 100° C of glycerin filled bimetallic thermometer in compliance to EN 13190, having standard range 0° C to 60° C up to 400° C, IP 67 protection, bimetal coil sensing element, accuracy class 1 as per EN 13190, stainless steel casing, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 stem and connection, aluminum dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), toughened glass window, neoprene filling plug and gasket complete with accessories, etc all as specified and as shown in drawings.
Supply, installation, testing and commissioning Pressure gauge of 100 mm dial size for pressure range 0 psi to 200 psi of glycerin filled pressure gauge in compliance to EN837-1, having standard range 15 to 0 psi and 16 psi to 10000 psi, IP 67 protection, accuracy class ±1.6% of FS, stainless steel casing and TIG argon welded socket to case, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 bourdon, socket, SS dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), polycarbonate glass window, neoprene blow off disc and filling plug, silicon gasket complete with accessories, etc. all as specified and as shown in drawings.
Supply, installation, testing and commissioning of pre-fabricated galvanized steel sheet (G.S.S.) square/rectangular ducting with 24 Gauge (MS angle flanges) for supply/return air, fabricated from galvanized steel sheet, having zinc coating of 160 gm/sq m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 with required scaffolding work to install the ducts at site complete all as specified and as shown in drawings.
All as per serial item No. 151 but with 22 gauge (MS angle flanges)
All as per serial item No. 151 but with 20 gauge (MS angle flanges)
All as per serial item No. 151 but with 18 gauge (MS angle flanges)
Supply, installation, testing and commissioning of fusible link spring return type fire damper complete as required for operation. The fire dampers shall be spring activated on melting of fusible link having melting point 67.13° C. The fire damper shall be located in the SA/RA ducts, at all fire rated crossoevers (shafts, walls, etc.). Fire damper shall be tested as per ULL- 555 and certified by CBRI complete all as specified and as shown in drawings..
Supply and fixing Acoustic Insulation with 25mm thick fibre glass rigid boards and finished with RP tissue paper and 28 mm gauge aluminium perforated sheet up to 5 m from outlet of the air plenum including 5 micron filters in air plenum for all AHUs complete all as specified and as shown in drawings.
Supply and Fixing of Thermal insulation with resin bonded Fibre Glass Wool density 24 KG / Cu.m] covered with GI chicken wire mesh and cladded with aluminium foil fixed with adhesive tape. complete all as specified and as shown in drawings.
Under deck insulation in AHU Rooms & Sun exposed salbs with Fire Retardant XPE closed cell of thickness 18 mm with metalized polyester film and self adhesive backing with protection peel off paper. Make: Armacell / K – Flex / Arma Flex / Supreme – 8 complete all as specified and as shown in drawings.
Supply, installation, testing & commissioning of removable supply air [SA] diffusers/grilles of extruded aluminum sections duly powder coated with volume control damper complete all as specified and as shown in drawings.
Supply, installation, testing & commissioning of removable Return air [RA] diffusers/grilles of extruded aluminum sections duly powder coated with volume control damper complete all as specified and as shown in drawings.
Supply, installation, testing & commissioning of 18 G galvanized sheet steel volume control duct damper complete all as specified and as shown in drawings.
Supply, installation, testing & commissioning of Fresh air damper with GI bowl/ fittings and mosquito proof netting shall be provided for each AHU Room complete all as specified and as shown in drawings.
Supply, installation, testing & commissioning of Motorised 18 G galvanized sheet steel volume control duct damper with necessary actuator complete all as specified and as shown in drawings.
Supply, installation, commissioning and testing of AC Plant Room panel board of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3 Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc complete all as specified.The panel shall be designed and wired in such a manner that the starter for condenser water pump is powered first, after that the cooling tower motor shall be powered, then the chilled water pumps shall be powered and the chiller units should get the supply only if the condenser water pumps, cooling tower motor, and chilled water pumps are in ON condition. The panel board shall comprise of the following accessories.
Supply, installation, commissioning and testing of AHU sub panel board of suitable size, factory made, CPRI type tested, indoor, 18 gauge MS CRCA duly powder coated in compartamentalised construction with incomer and outgoing feeders for AHU motor, 3-way valve actuator motor, Heater Bank/Pan Humidifier,fire damper actuator motor, etc. complete with required variable frequency drive, relays, timers, contactors, PT, push buttons, switches, internal wiring, etc.AHU electrical panels of following Capacitys. a) 3.7 KW - 2 Nos b) 5.5 KW - 6Nos c) 7.5 KW - 1 No d) 11 KW - 1 No e) 15 KW - 1 No
Supply,laying and Termination of sizes 185.0 Sqmm, 3.5 core, PVC insulated and PVC sheathed XLPE aluminium conductor UG armoured cable of 1.1 KV grade confirming to IS:7098 (Part-I) 1988 with upto date amendments duly ISI marked complete with necessary Lugs,Glands and accessiries as required all as specified and as shown in drawings.
All as per Serial item No. 166 above but of size 16 sq mm, 4 core.
All as per Serial item No. 166 above but of size 10 sq mm, 4 core.
Earthing complete with Copper Earth Plate Electrode 600 X 600 X 3 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 25x3.15mm copper strip [Earth Lead] and GI pipe 400 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
M&L for 25 mm X 3.15 mm copper strip through and including 40 mm dia GI pipe medium grade from earth electrode including connection with brass nut, bolt, spring, washer complete all as specified and as directed. NOTE : [i] Rate quoted shall deemed to be included for Supply and laying of 40mm dia GI pipe. [ii] Earth work and excavation in any type of soil , returning filling in and removal of excess soil if any shall be measured and paid seperately under relevant items of Schedule 'A' part II.
M&L for 32 mm X 6 mm copper strip on surface or in recess for connections etc. as required complete all as specified and as directed.
M&L for 6 SWG dia G.I. wire on surface or in recess for loop earthing as required complete all as specified and as directed.
Supplying and installing perforated GI. cable trays of size 100 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with suspenders including bolts & nuts, etc as required complete all as specified and as directed.
Supplying and installing perforated GI. cable trays of size 150 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with suspenders including bolts & nuts, etc as required complete all as specified and as directed.
Supplying and installing perforated GI. cable trays of size 300 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with suspenders including bolts & nuts, etc as required complete all as specified and as directed.
Supply, installation, testing and commissioning of Hi Wall type Split AC units indoor/outdoor complete with cordless remote control unit with inverter type rotary compressor, single phase units 220- 240 V, 50 Hz, 5 star rated of 2.0 TR capacity including M&L for necessary timer and power contactor etc for automatic change-over of two AC units. complete all as specified and as directed.
PHASE – III: SCHEDULE "A" PART – XIX: OUTSOURCING OF SERVICES FOR OPERATION OF CENTRAL AC PLANT AS PROVIDED UNDER THIS CONTRACT [AS PER SERIAL ITEM No. 101 to 176 OF THIS BOQ/ SCHEDULE "A" PART – XVII] FIRST YEAR AFTER SUCCESSFUL COMPLETION OF PHASE – II TESTING [i.e. during FIRST YEAR of defects liability period for AC plant after conpletion of Phase II test.] Outsourcing of Services for Operation of Central AC Plant of 3 X 150 TR, Water Cooled Central AC Plant [2 Nos Running & 1 Nos Standby] as provided under this contract as per Serial Item No. 101 to 176 of this BoQ / Schedule "A" Part – XVII for First Year after successful Completion of Phase – II Testing i.e. during Defect Liability Period complete including Cooling Tower, AHUs, Electrical Control Panels, and Pumps and connected Equipment in complete AC system, round the clock in 3 Shifts of 08 Hours each to ensure smooth and trouble free operation of plants to the entire satisfaction of users / department by providing services of One Skilled Technician of AC & Refrigeration [ITI Qualified with 2 to 3 years relevant experience]in each shift of 08 Hours complete all as specified and as directed by Engineer-in-Charge.
PHASE – IV: SCHEDULE "A" PART – XX: OUTSOURCING OF SERVICES FOR OPERATION OF CENTRAL AC PLANT AS PROVIDED UNDER THIS CONTRACT [AS PER SERIAL ITEM No. 101 to 176 OF THIS BOQ / SCHEDULE "A" PART – XVII] SECOND YEAR AFTER SUCCESSFUL COMPLETION OF PHASE – II TESTING [i.e. during SECOND YEAR of defects liability period for AC plant after conpletion of Phase II test.] Outsourcing of Services for Operation of Central AC Plant of 3 X 150 TR, Water Cooled Central AC Plant [2 Nos Running & 1 Nos Standby] as provided under this contract as per Serial Item No. 101 to 176 of this BoQ / Schedule "A" Part – XVII for First Year & Second year after successful Completion of Phase – II Testing i.e. during Defect Liability Period complete including Cooling Tower, AHUs, Electrical Control Panels, and Pumps and connected Equipment in complete AC system, round the clock in 3 Shifts of 08 Hours each to ensure smooth and trouble free operation of plants to the entire satisfaction of users / department by providing services of One Skilled Technician of AC & Refrigeration [ITI Qualified with 2 to 3 years relevant experience]in each shift of 08 Hours complete all as specified and as directed by Engineer-in-Charge.
PHASE – V: SCHEDULE "A" PART – XXI: OUTSOURCING OF SERVICES FOR OPERATION OF CENTRAL AC PLANT[ AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 101 to 176 OF THIS BOQ / SCHEDULE "A" PART – XVII] AND COMPREHENSIVE MAINTENANCE OF CENTRAL AC PLANT FOR THIRD YEAR AFTER SUCCESSFUL COMPLETION OF PHASE – II TESTING [i.e. FIRST YEAR AFTER SUCCESSFUL COMPLETION OF DEFECT LIABILITY PERIOD OF WORK UNDER PHASE–II[ie after sucessfull completion of Phase -II testing of AC plant] Outsourcing of Services for Operation of Central AC Plant of 3 X 150 TR, Water Cooled Central AC Plant [2 Nos Running & 1 Nos Standby] as provided under this contract as per Serial Item No. 101 to 176 of this BoQ / Schedule "A" Part – XVII for Third Year after successful Completion of Phase – II Testing i.e. First Year after successful completion of Defect Liability Period complete including Cooling Tower, AHUs, Electrical Control Panels, and Pumps and connected Equipment in complete AC system, round the clock in 3 Shifts of 08 Hours each to ensure smooth and trouble free operation of plants to the entire satisfaction of users / department by providing services of One Skilled Technician of AC & Refrigeration [ITI Qualified with 2 to 3 years relevant experience]in each shift of 08 Hours complete all as specified and as directed by Engineer-in-Charge.
Phase-VI : Schedule 'A' Part -XXII COMPREHENSIVE MAINTENANCE OF PASSENGER LIFTS: Comprehensive maintenance of electrically operated passengers lift of capacity 13 passengers lift of capacity 884 Kgs for G+5 floors building) all as mentioned vide Serial Item No. 68 of BOQ complete all specified in PS and as directed for First Year after expiry of Defects Liability Period of PHASE I. [Rate quoted shall deemed to be included for 2 Nos of passenger lifts] Note: [a] Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of gear oil/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above lifts. [b] Preventive maintenance consists of carrying out routine check by skilled personnel as specified in particular specifications and as recommended by Engineer-in-charge and lubrication to all moving parts ,topping parts, topping up of oils as per lubrication chart including Material and Labour for all consumable and major/minor spare parts [c] Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labor for all minor & major spare parts and consumables of the lift that may occur during the operation. [d] Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor.
Phase-VI : Schedule 'A' Part -XXII COMPREHENSIVE MAINTENANCE GOODS LIFT: Comprehensive maintenance of electrically operated Goods lift of capacity 2000 Kgs for G+6 floors as detailed in SL item No.69 of BOQ complete all specified in PS and as directed for First Year after expiry of Defects Liability Period of PHASE I. Note: Notes same as given in SL item No 180 above
Phase-VI : Schedule 'A' Part -XXII COMPREHENSIVE MAINTENANCE SOLAR FENCING: Comprehensive maintenance of Solar power fencing and attending complaints by employing technically qualified engineer/Technician for regular maintenance and repairs of 250M long electric solar power fence including all connected components of power fencing all specified in PS and as directed for First Year after expiry of Defects Liability Period of Phase I.
PHASE –VII: SCHEDULE "A" PART – XXIII: SECOND YEAR COMPREHENSIVE MAINTENANCE OF PASSENGER LIFTS [02 Nos] All as per Serial Item No. 180 above but for Second Year after expiry of Defects Liability Period of Phase I. [Rate quoted shall deemed to be included for 2 Nos of passenger lifts]
PHASE –VII: SCHEDULE "A" PART – XXIII: SECOND YEAR COMPREHENSIVE MAINTENANCE OF GOODS LIFT [01 Nos] All as per Serial Item No. 181 above but for Second Year after expiry of Defects Liability Period of Phase I.
PHASE –VII: SCHEDULE "A" PART – XXIII: SECOND YEAR COMPREHENSIVE MAINTENANCE OF SOLAR FENCING All as per Serial Item No. 182 above but for Second Year after expiry of Defects Liability Period of Phase I.
PHASE –VIII: SCHEDULE "A" PART – XXIV: THIRD YEAR COMPREHENSIVE MAINTENANCE OF PASSENGER LIFTS [02 Nos] All as per Serial Item No. 180 above but for Second Year after expiry of Defects Liability Period of Phase I. [Rate quoted shall deemed to be included for 2 Nos of passenger lifts]
PHASE –VIII: SCHEDULE "A" PART – XXIV: THIRD YEAR COMPREHENSIVE MAINTENANCE OF GOODS LIFT [01 Nos] All as per Serial Item No. 181 above but for Second Year after expiry of Defects Liability Period of Phase I.
PHASE –VIII: SCHEDULE "A" PART – XXIV: THIRD YEAR COMPREHENSIVE MAINTENANCE OF SOLAR FENCING All as per Serial Item No. 182 above but for Second Year after expiry of Defects Liability Period of Phase I.
M/S. KASHI KANCHAN PVT. LTD.
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
K KUMAR RAJA PROJECTS P LIMITED
RVR PROJECTS PRIVATE LIMITED
Komal Buildcon Pvt. Ltd.
KEC International Ltd
B D Raizada Projects Pvt Ltd
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid