Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC R O SKERBUCHAN TEH KHALTSI LEH LADAKH 194106 | LEH LADAKH | LADAKH | 194106 | ₹14.2 L Quoted ₹14.5 L | L1 | Accepted-AOC L1 and quoted reasonable rates |
| 2 | L2₹19.1 L+₹4.6 L (31.6%)Rejected-AOC | ₹19.1 L+₹4.6 L (31.6%) | L2 | Rejected-AOC L2 |
| 3 | L3₹19.5 L+₹5.0 L (34.6%)Rejected-AOC | ₹19.5 L+₹5.0 L (34.6%) | L3 | Rejected-AOC L3 |
| 4 | L4₹20.2 L+₹5.7 L (39.1%)Rejected-AOC | ₹20.2 L+₹5.7 L (39.1%) | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹29,960
Closing Date
21 Sept 2021, 6:00 pmClosed
GE KHUMBATHANG
GE KHUMBATHANG
GE/KHU-18/2021-22 REPAIR/ MAINTENANACE OF EXTERNAL WATER SUPPLY, UNSERVICEABLE GI PIPES AND CONNECTED E/M WORKS IN THE AOR OF AGE BR-II,KHALTSI UNDER GE KHUMBATHANG
2021_MES_463280_2
GE/KHU-18/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE KHUMBATHANG
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KHUMBATHANG
₹29,960
15 Nov 2021
1 Sept 2021
22 Sept 2021
1 Sept 2021
21 Sept 2021
8 Sept 2021
Amount
Excavation in trenches, getting out in soft/loose soil not exceeding 1.5m deep and not exc 1.5m wide for taking out the existing cable of poles etc. any size at places complete all as specified and directed.
Removing of surplus soil to a distance not exceeding 50 mtr complete all as specified and deposited where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning filing including spreading levelling, watering & well ramming in layers not exceeding 25 Cm thick complete all as specified and directed.
M&LSand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I.
M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site.
Taking up/down steel tubing/CI/Cement and connection from trenches incl connected fittings/accessories complete of following sizes for re-use of serviceable pipes and removing the U/S pipes from site to safe custody : -
(a) 80 mm bore
(b) 50 mm bore
(c) 40mm bore
(d) 25mm bore
(e) 20mm bore
(f) 15mm bore
S&F steel water tubing galvanized medium grade laid in trenches including all necessary fittings clamps etc complete and connecting to existing system all as directed and specified by Engr-in-Charge of following bore sizes.
(a) 80 mm bore
(b) 50mm bore
(c) 40mm bore
(d) 25mm bore
(e) 20mm bore
S&F steel water tubing galvanized medium grade laid in wall or laid under floor including all necessary fittings clamps etc complete and connecting to existing system all as directed and specified by Engr-in-Charge of following bore sizes.
(a) 25mm bore
(b) 20mm bore
(c) 15mm bore
Material and labour for brick masonry valve pit nominal size 60 cm x 60 cm x 60 cm with one brick thick wall using precast cement block of size 20cmx10cmx10cm brick in cement mortar 1:6 over 20 cm thick PCC plate form with 15 cm off set on every side of 1:3:6 type C-1 including plastering of internal surfaces and exposed surfaces with 15 mm thick plastering in cement mortarf 1:4 and 50- mm thick RCC cover (in two equal parts 1:2:4) type B-1 with 10 mm dia deformed bars at 10 cm interval on both side including necessary form work with 150 mm dia hole in the center complete all as specified and as directed by Engineer-in-Charge.
Material and labour for brick masonry valve pit nominal size 45 cm x 45 cm x 45 cm with one brick thick wall using precast cement block of size 20cmx10cmx10cm brick in cement mortar 1:6 over 20 cm thick PCC plate form with 15 cm off set on every side of 1:3:6 type C-1 including plastering of internal surfaces and exposed surfaces with 15 mm thick plastering in cement mortarf 1:4 and 50- mm thick RCC cover (in two equal parts 1:2:4) type B-1 with 10 mm dia deformed bars at 10 cm interval on both side including necessary form work with 150 mm dia hole in the center complete all as specified and as directed by Engineer-in-Charge.
Taking out old/unserviceable float valve and supply & fixing PVC float valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of 20mm bore complete all as specified and directed by Engineer-in-Charge.
Taking out old/unserviceable gate valve and Supply and fixing gun metal gate valve ISI marked with iron wheel screwed down high pressure screwed both ends for iron pipe of size 50mm bore complete all as specified and directed by Engineer-in-Charge.
Description all as per item 12 here in before but 40 mm bore
Description all as per item 12 here in before but 25mm bore
Description all as per item 12 here in before but 20mm bore
Supplying and fixing, jointing, testing of Sluice Valve of sizes dia 80mm , ISI Marked, flanged ends drilled pressure rating PN-1.6, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve complete all as specified and as directed at site by the Engineer-in-Charge.
Supplying and fixing, jointing, testing of Sluice Valve of sizes dia 50mm , ISI Marked, flanged ends drilled pressure rating PN-1.6, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve complete all as specified and as directed at site by the Engineer-in-Charge.
M&L for Lagging to pipes of size 25 mm bore used in water supply or plumbing all round with, 25mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842, incl chicken wire mesh wire netting 25 gauge 20mm mesh and 0.01mm aluminium foil for covering of wire mesh and mineral wool complete all as specified and directed .
Description all as per item 18 here in before but 20 mm bore complete all as specified and directed
Taking down dismantling, disconnecting carefully and transportation for taking electric motor 415 vols 50 Hz 3 phase submersible motor 02 to 05 HP to workshop complete all as specified and as directed by Engr in charge.
M&L for complete rewinding, servicing and refixing of 415 volts 50 Hz 01 to 02 HP submersible motor and refixing/lowering down at existing same place and testing incl required accesssories i.e. nuts bolts, washers etc complete all as specified and as directed.
M&L for complete rewinding, servicing and refixing of 415 volts 50 Hz 03 to 05 HP submersible motor and refixing/lowering down at existing same place and testing incl required accesssories i.e. nuts bolts, washers etc complete all as specified and as directed.
M & L for earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6mm as earthing lead covered with 40mm bore GI pipe light grade by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20 mm dia GI watering pipe 'medium grade', funnel with wire mesh, earthing chamber with cement concrete (1:3:6) type C-1, RCC chamber cover 80 mm thick (1:2:4) type B-1, excavating & earth work all as shown in electrical plate No.5 of SSR (Part-I) and testing on completion complete all as specified and directed. Note:- Length upto 7.5m of GI strip is inclusive in unit rate.
M&L for earthing complete with galvanized cast iron earth plate electrode 60cm x 60cm x 6mm buried directly in ground(earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtrs below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts,nuts, and galvanized iron or steel all as shown on electrical plate No.05 of SSR Part-1 connected to earthing test point all as specified or indicated including earth work in any type of soil, charcoal salt 15cm around the earth plant as shown in electrical plate No. 3 of SSR Part-I, 20 mm dia watering pipe light grade 1.70 mtr long with plug at top, GI protection pipe light grade 15 mm dia from earth pit to main boad including testing after completioncomplete all as specified and directed. Note:- (i) Maximum length of GI wire, protection pipe with each earth shall not exceed 7.5 mtrs. (ii) The 20 mm dia watering pipe shall be 20 cm above the ground level and be provided with 20 mm dia GI plug at its top and no concrete watering pit/cover shall be provided.
S & F in repairs MCCB 160 Amp, 4 pole 36 KA with release adjustable thermal & fixed magnetic 415 volt AC supply IP 20 complete all as specified and directed by Engineer-in-Charge.
S & F in repairs MCCB 100 Amp, 4 pole 25 KA with release adjustable thermal & fixed magnetic 415 volt AC supply IP 20 complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Exhaust fan of metal body AC single phase 230 volt of size 300mm sweep with blades and frame and louvers Complete all as specified and directed
S&F changeover switch 200 amp 415 volts four pole with sheet metal enclosure complete all as specified and directed.
S&F changeover switch 125 amp 415 volts four pole with sheet metal enclosure complete all as specified and directed.
Supply and fix in replacement submersible flat .black pvc cable of size 2.5 sqmm copper conductor as per IS 694.complete all as specified and directed
Supply and laying in replacement of synthatic rubber insulated mats 2.5 mm thick for electrical purpose as per IS 15652. suitable for electrical shock saftey of size 2mx1m complete all as specified and directed
S&F DOL Starter for submersible motor of capacity 05 HP, 415 volts, 50 HZ 3 Phase complete all as specified and directed
Supply and fix in replacement of 25 MM 3 layer PP-R Pipes PN 16 UV stablized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plan and brass thread polypropylene random fittings fixed complete to walls,cellings. all as specified and directed
Disconnecting & taking out existing unserviceable cable of 35/50/70sqmm 3.5/4 core complete all as specified and as directed.
Supply and laying XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cable heavy duty 1100 Volt grade with stranded aluminium conductor of size 70 Sq mm 3.5 core complete all as directed.
Supply and laying XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cable heavy duty 1100 Volt grade with stranded aluminium conductor of size 50 Sq mm 3.5 core complete all as directed.
Supply and laying XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cable heavy duty 1100 Volt grade with stranded aluminium conductor of size 35 Sq mm 3.5 core complete all as directed.
M&L for Cleaning of under ground water sump internally from base to top including scraping the mud, silt from base and walls washing the complete internal surfaces with clean water, removing the silt/mud water out side cantt area and desilting from connecting pipes and applying internally one coat of lime wash to RCC walls, base of tanks of cap 50000 ltrs complete all as directed by Engr-in-charge. Note: Item rate includes necessary disconnection and reconnection of pipelines before and after cleaning of the tank where required.
S&F in repair Rotational moulded polyethylene water storage tank 500 Ltrs capacity triple layered (cylinderical/vertical with closed top) hoisted and fixed in position, inside or outside the building, including minor repairing to iron pipe for making connections and securing access cover complete all as specified and directed.
Supply & fixing in replacement. installation. testing and commissioning of feeder pillar box ,indoor type cubical shape,three phase, 4 wire, copper bus bar for phases and neutral made out of CRCA sheet 2.0 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following items including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc .
(a) Copper bus bar with PVC sleev suitable for 250 amps - 01Set.
(d) Phase indicating lamps LED type ( red , yellow, blue) -- 01 set
(e) Incoming MCCB 160 Amp 3pole 36 KA with adjustable thermal and fixed magnetic release -01Nos
(f) Outgoing MCCB 63 Amp 4 pole 16 KA with adjustable thermal and fixed magnetic release - 02 No
(g) Outgoing MCB TPN 40 Amp 10KA - 06 Nos
(h) Outgoing MCB SPN 20 Amp 10KA - 05 Nos
Deduct Credit for Demolished/ Dismantled material Rs. (-) 29,945.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note: Tenderers will not quote against this item being a tentative amount to be considered to arrived at the 'Contract Sum'
CHAMRAN TRADING NAD CONSTRUCTION KARGIL
M/S B K ENTERPRISES
M/S ABASS ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .