Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 CrAccepted-AOC 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | ₹5.9 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹6.4 Cr+₹53.0 L (9.02%)Rejected-AOC 583 URBAN ESTATE II HISAR 125005 | HISAR | HISAR | HARYANA | 125005 | ₹6.4 Cr+₹53.0 L (9.02%) | L2 | Rejected-AOC Other than Lowest Bidder |
| 3 | L3₹6.6 Cr+₹72.4 L (12.3%)Rejected-AOC 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹6.6 Cr+₹72.4 L (12.3%) | L3 | Rejected-AOC Other than Lowest Bidder |
| 4 | L4₹7.1 Cr+₹1.2 Cr (20.1%)Rejected-AOC C 33 3971 GALI NO 6 JALANDHAR CANTT 144005 | JALANDHAR | JALANDHAR | PUNJAB | 144005 | ₹7.1 Cr+₹1.2 Cr (20.1%) | L4 | Rejected-AOC Other than Lowest Bidder |
| 5 | Rejected-Technical 6313 14 PUNJABI MOHALLA AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | - | - | Rejected-Technical Enlistment valid upto 31 Dec 2025 |
| Sl No | Description | Qty | Unit | Siya constructions L2 | J.D.Builders L3 | M/S Mukesh Kumar Gupta L4 | KULWANT SINGH L1 |
|---|---|---|---|---|---|---|---|
| 1.00B/R Work | |||||||
| 2.00 | Demolition of cement concrete (any description, unreinforced) in existing sunken portion of WC/Floor trap including removing all debris complete all as specified and directed. | 22.7 | Cubic Metre | 125 ₹2,837.5 | 150 ₹3,405 | 250 ₹5,675 | 100 ₹2,270 Lowest |
| 3.00 | 40mm dia (bore) GI pipe medium grade as in spout, fixed in repair complete all as specified and directed. | 20 | Running Metre | 445 ₹8,900 | 150 ₹3,000 Lowest | 425 ₹8,500 | 450 ₹9,000 |
| 4.00 | PCC 1:5:10 type E2 using 40mm broken brick aggrgate as in filling in sunken portion of floor complete all as specified and directed. | 22.7 | Cubic Metre | 1,227 ₹27,852.9 | 1,200 ₹27,240 Lowest | 2,200 ₹49,940 | 2,500 ₹56,750 |
| 5.00 | Water proofing treatment to sunken floors of bathroom/WC/kitchen etc. as given below, all as per manufacturer's instructions, complete all as specified and directed: -
(a) Cleaning the concrete surface of top of the RCC slab and peripheral beams of sunken portion by wire brushing & washing with water, cutting out cracks, if any, to 'V' section in existing RCC roof slab or terracing, cleaning out, wetting, grouting with PMC mortar.
(b) All brick joints and superficial cracks shall be repaired with polymer modified mortar using URP as admixture at the rate 10% of cement content
(c) PCC kerb and padding shall be laid to desired slope using waterproofing compound (payment shall be done separately under respective concerned items).
(d) 15 mm thick polymer modified mortar using URP as admixture at the rate 10% of cement content shall be applied on slope base and vertical surfaces.
(e) Sealing of all joints/ trap/WC/Soil pipe with approved sealing compound.
(f) The surface thus prepared shall be coated with two coats of Dr Fixit Hydrochem Super or equivalent in specified makes.
(g) A layer of open woven glass fibre mesh shall be laid over base and vertical surface of sunken area.
(h) Rendering 10 mm thick using polymer modified mortar shall be done over entire area.
(j) Curing the sunken portion with water for minimum 48 hours by ponding.
(k) Testing before filling of sunken slabs.
Note:- (i) For measurement area to be treated with compound only shall be measured.
(ii) Work shall be got executed through manufacturer/authorized applicator of manufacturer only. Contractor shall enter into necessary MOU between contractor, manufacturer and their authorized applicator before execution.
(iii) Every stage of work i.e. (a), (b), (c) etc shall be approved by GE. Only then next stage/layer shall be commenced.
(iv) Props to be placed at bottom of the sunken slab before starting the work. | 89 | Square Metre | 777 ₹69,153 | 600 ₹53,400 Lowest | 800 ₹71,200 | 650 ₹57,850 |
| 6.00 | Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding precast concrete articles and removal of debris complete all as specified and directed. | 120 | Cubic Metre | 120 ₹14,400 Lowest | 150 ₹18,000 | 200 ₹24,000 | 200 ₹24,000 |
| 7.00 | Brick work with old size fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed. | 120 | Cubic Metre | 5,877 ₹7,05,240 | 4,500 ₹5,40,000 Lowest | 4,600 ₹5,52,000 | 5,000 ₹6,00,000 |
| 8.00 | All as per Srl Item No 07 here-in-before but except bricks. | 10 | Cubic Metre | 2,277 ₹22,770 | 2,000 ₹20,000 | 2,200 ₹22,000 | 1,800 ₹18,000 Lowest |
| 9.00 | Dubbing out average 10 mm thick on irregular surfaces of soffit of slab/chajjas/ sunshades etc in cement mortar 1:4 (when specifically ordered in writing) complete all as specified and directed. | 250 | Square Metre | 250 ₹62,500 | 200 ₹50,000 Lowest | 350 ₹87,500 | 200 ₹50,000 Lowest |
| 10.00 | Providing one layer of guniting of thickness not exceding 50 mm (by skilled labour and specialised equipment for high pressure spraying process) in cement mortar 1:3 for top & bottom of roof slabs, beams, columns and staircase etc, after preparation of surfaces by cleaning and sand blasting to remove rust and loose debris to ensure strong bond including scaffolding upto double storey height, steel reinforcement and chicken wire mesh secured by means of tinned tacks or welded to existing reinforcement, if required, complete all as specified and directed. Note: Steel reinforcement and chicken wire mesh shall be measured and paid for separately as 'supply only'. | 200 | Square Metre | 677 ₹1,35,400 | 550 ₹1,10,000 | 550 ₹1,10,000 | 400 ₹80,000 Lowest |
Tender Value
₹7.1 Cr
EMD Value
₹6.8 L
Closing Date
1 Nov 2025, 6:00 pmClosed
Chief Engineer Chd Zone
HQ CE Chandigarh Zone N Area, Airport Road Chandigarh-160003
CA NO CE CHZ AMB T 13 2025 26 RESTORATION OF MD ACCN TO ARREST IMMEDIATE LEAKAGE AND SEEPAGE WITH ASSOCIATED WKS AT AMBALA CANTT UNDER GE N AMBALA
2025_MES_725932_1
CE CHZ/AMB/T-13/2025-26
Open Tender
Civil Works
Item Rate
365 days
Ambala
As per Tender Documents
9 documents required · 9 mandatory
₹3,000
GE N Ambala
₹6.8 L
Yes
17 Feb 2026
13 Aug 2025
3 Nov 2025
13 Aug 2025
1 Nov 2025
25 Oct 2025
13 Aug 2025 - 30 Aug 2025
Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 on any faces of brick work or concrete wall surfaces and finished fair & even without using extra cement including necessary scaffolding etc complete all as specified and directed.
Excavation / cutting the existing hard standing/PCC/WBM road at a depth no
Rough cast plaster as specified in SSR Part-I, clause 14.22 consisting of under coat in cement mortar 1:3 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel aggregate which is generally of size between 6 to 12 mm depending on texure required mixed with coarse sand and cement in the ratio 1:1:1 shall be applied complete all as specified and directed.
Rendering 5 mm thick on ceiling surfaces of brick work or concrete wall surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plaster surface of ceilling and applying three coat of white wash complete all as specified and directed.
Preparation of new plastered /concrete surface of wall, applying two coats of cement base paint over and including a coat of alkali resistant primer complete all as specified and directed.
Preparation of new plastere surface of walls and applying two coats of oil bound distemper over and including a coat of 2 mm thick cement base putty and a coat of alkali resistant primer complete all as specified and as directed.
Complete removal of existing treatment on ceiling (any number of layers) by scrapping with steel scrappers or any other means, washing down with water to remove loose particles etc and applying two coats of white wash complete all as specified and directed by Engineer-in-Charge
Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, washing down with water to remove loose particles etc and applying two coats of cement base paint over and including a coat of alkali resistant primer complete all as specified and directed by the Engineer-in-Charge
Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, washing down with water to remove loose particles etc and applying two coats of oil bound distemper with painting roller over and including a coat of alkali resistant primer and 2mm thick wall care putty white cement based in two coats to achieve smooth surface complete all as specified and directed.
Roughening concrete surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and directed..
25mm thick cement concrete 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floors complete all as specified and as directed.
Non–skid ceramic colour tiles 7 to 8mm thick (square /rectangular) area of each tiles exc 0.11 sqm but n exe 0.18 sqm, in floor etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in cement mortar (1:6) , complete all as specified and directed.
Glazed ceramic colour tiles in vertical surface 300X600X7mm thick in dado, skirting etc, set and jointed in neat cement slurry and pointed in coloured cement to match including 10 mm thick rendering in cement mortar 1:4 , complete all as specified and directed
Non skid coloured ceramic tiles 7 to 8 mm thick, (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inculding 15mm thick screed bed in cement mortar (1:6) , complete all as specified and directed
Non skid coloured ceramic tiles of 7 to 8 mm thick, (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick /concrete surfaces in cement mortar (1:4), complete all as specified and directed
300x300 mm & 10mm thick anti-skid pavement tile Endura vetrified tile in approved color & shade and in anti skid finish, set and jointed in neat cement slurry and pointed in white cement & pigment to match over and including 15 mm thick screed bed in cement mortar 1:4 and including desmantiling existing old floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
300x300 mm & 10mm thick anti-skid pavement tile Endura vetrified tile in approved color & shade and in anti skid finish, set and jointed in neat cement slurry as in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick /concrete surfaces in cement mortar (1:4), complete all as specified and directed complete all as specified and directed
Double charged vitrrfied ceramic tile light shade 10 mm thick (square/rectangular) polished , area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 15mm thick rendering on fair faces of brick /concrete surfaces in cement mortar (1:6), complete all as specified and directed
Granite (of any type) slab 18-20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed in white cement as in floors/ cooking platform, with admixiture of pigment to match the shade of granite stone including grinding and mirror polishing complete over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations including machine polishing to edge to give high glass finish etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
PCC 1:2:4, type B-0 (using 12.50mm graded crushed stone aggregates) for levelling of floor finishes such as tiles etc., complete all as specified and directed.
75 mm thick cement concrete 1:3:6, type C–1 (using 20mm graded crushed stone aggregates) as in plinth protection laid in alternate bays (n exc 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight , complete all as specified and directed.
100mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in sub base , complete all as specified and directed.
Machine pressed precast concrete interlocking paver block any shape and size laid over & including 25 mm thick sand layer conforming to IS 15658-2006 of 60 mm thickness grade M-35 with grey cement and no pigments laid over & including complete all as specified and directed
20–25mm thick machine cut kota stone slab as in floor/treads over 15mm thick screed bed in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match the shade including grinding and polishing complete.
18-20 mm thick machine cut kota stone slab over as in skirting, riser of steps, dado & pillar etc. over 10mm thick screed layer in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match the shade including grinding and polishing complete.
M&L 16–18mm thick baroda green marble slab as in skirting, riser of steps, dado & pillar, in single length, over 10mm thick screed bed in CM 1:4 set and jointed in neat cement slurry mixed with pigment to match the shade including grinding and polishing complete.
Dismentling of mild steel work of any description, complete all as specified and directed.
Rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, hollow tube or flat sections) including distance pieces, cleats etc. conforming to Fe–410–W (Gde–E–250) quality 'A' complete all as specified and directed.
Dismantling of plain or corrugated asbestos cement sheet of any thickness incl Nainital or similar pattern coverings, complete all as specified and directed.
Pre–painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having zinc coating 150 grams per Sqm of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed.
Pre–painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa having zinc coating 150grams/Sqm as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantiling of brick tiles or terracing tiles, single layer on roofs complete all as specified and as directed by the Engineer-in-charge
Demolition of mud in roofs, any thickness, including old tar felt, plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and as directed by the engineer-in-charge
Removing all loose dirt, cement plaster, cleaning the concrete surface including removal & cleaning of vegetation, fungus, moss small tress etc from the roof top with wire brush, removing the strips of lightening conductor including refixing the same after repair work and applying neat cement slurry @ 1.5Kg/Sqm complete all as specified and directed.
Cement concrete (1:3:6) type B-1 using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, padding, rounded or chamfered on edges including form work where ever required.
Rendering 10 mm thick on existing concrete surface of roof in cement mortar 1:4 including mixing liquid water proofing
compound @ 200ml per 50 Kg of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and directed. (Note:- L-WPC shall be measured & paid separately)
Providing and laying at any height 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.60 kg/Sqm, water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bituminious primer @ 0.40 ltr / Sqm by the same membrane manufacturer roof membrane over existing RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg/ ltr at 25 degree centigrade on prepared surface. (c) Apply on APP membrane a coat of hot blown bitumen grade 85/25 conforming to IS 702 @ 1.20 Kg per Sqm (d) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fabric (weight not less than 160gm/Sqm) using butane torch by torch application with 10cm side laps and 15cm end lap. (e) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. .
Cement concrete tiles 30 cm x 30cm x 20 mm thick, machine pressed laid on screed bed and joints grouted flush in CM (1:3) mixed with 5% crude oil by weight of cement including screed bed 15 mm thick in cement mortar (1:6) , complete all as specified and directed.
Supply only Liquid water proofing compound, ISI marked complete all as specfic & director.
Preparation of new or previously untreated surfaces and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on steel surfaces of any description, not otherwise described, over 10cm width or girth complete all as specified and as directed
Taking down chowkats or frames with shutter area not exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish, complete all as specified and directed..
Taking down chowkats or frames with shutter area exceeding 1.50 Square meter and not exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish, complete all as specified and directed..
Taking down shutters of any description exc 1 sqm but n exc 2 sqm each and removing from site, complete all as specified and directed..
Taking down and refixing in same opening of shutters of any description exc 1 sqm but n exc 2 sqm each with iron mongeries complete all as specified and directed..
Dismantling wrought iron or mild steel work of any description not otherwise provided for iron door etc
Rolled mild steel framed work as in chowkats of door or gates of angle or other section with gusset plates, rails braces etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-410-W (Grade E-250) quality 'A', complete all as specified and directed..
0.80 mm thick mild steel plain black sheet in covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed.
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gm) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/Sqmm, modules of elasticity 900 N/Sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with and including MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
All as per Srl No 60.00 here-in-before but frame size 100 x 65 mm
All as per Srl No 60.00 here-in-before but frame size 45x70mm
Mild steel work (miscellaneons) angle /tee /beam /hollow MS section for channel gate/door /window frames /chowkhat, window guard bars etc., and similar articles conforming to Fe–410–0 or Fe–310–0 complete all as specified and directed.
Factory made single extruded WPC (Wood Polymer Composite) solid decorative type moulded flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/Sqmm , modulus of elasticity 850 N/Sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as per direction of Engineer-In-Charge. Note: stainless steel butt hinges and necessary S.S screws shall be paid separately
Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/Sqmm , modulus of elasticity 850 N/Smm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: stainless steel butt hinges and necessary S.S screws shall be paid separately
Factory made single extruded WPC (Wood Polymer Composite) glazed and skelton door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/Sqmm , modulus of elasticity 850 N/Sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. Note: wire mesh ,stainless steel butt hinges shall be measured and paid separately.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face for APP Membrance, galvalume etc of groove with cement mortar 1:3 complete all as specified and directed.
Cement concrete type B-0, 1:2:4 (using 12.50mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete, all as specified and directed.
Ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated(PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 GSM/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick. GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 75X 58mm outer frame , Mullion 74 x 53mm, Glazed shutter 48 x 22mm, Flymesh 42 x 21mm, Beading for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters, the sections cut to length, mitre joined with corner PolyVinylChloride brackets, centre mullion fixed with Polyvinylchloride Mullion caps . Glass of 4mm thick plain float glass fitted with rubber gasket in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with CRCA of zinc phosphate coat. Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, Polyvinylchloride handle 1 in each and Powder coated Peg stay in Glass shutter. Window shall be provided with enamel paint MS Grill/Guard Bars made of 10mm horizontal MS Sq Bar welded to 6 x 12mm MS Flat at with holes at both vertical ends . Gap between the bars shall not be more than 152 mm . Window frames shall be fixed to brick / concrete masonry by using nylon self expansion caps & 75/100 mm MS screws after drilling in walls. VC Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows complete all as spec & director.
Powder coated aluminium (minimum thickness of powder coating 50 micron) for frame and shutters of doors, windows (fixed, sliding hanging) & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling justify up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed.
Providing and fixing stainless steel (Grade 304) grills made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fixing the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specifed and directed.
3mm thick frosted sheet glass ordinary type and glazing with aluminium beading, rubber packing or oil putty in square n exc 0.5 sqm each pane complete all as specified and directed.
Preparation of old decorated wooden surfaces with one coat of synthetic enamel (ordinary tint) of any description, not otherwise, described, over 10cm width or girth complete all as specified and directed.
Preparing old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
Dismantiling of old wooden/PVC boarding/shelves of kitchen cabinets and cupboards any description, fixed in any position with nails
All as per Srl No 78.00 here-in-before but 12mm thick
100mm MS Butt hinge medium weight cold rolled complete all as specified and directed.
100mm MS Butt hinge medium weight cold rolled fixed in repair complete all as specified and directed.
30mm continuous (piano) hinges, mild steel, bright f
inish or electrogalvanised, fixed in repair.
200mm long aluminium, anodised, barrel tower bolt of extruded section complete all as specified and directed.
150mm long aluminium handles, cast type, anodised complete all as specified and directed.
250 mm long aluminium sliding door bolt, plate type, stove enamelled black with bright bolt not less than 12 mm dia with and including minimum of 6 bolts and nuts, four on bolt plate and two on staple and fixed complete all as specified and directed.
100 mm long hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor 150mm overall length of cover plate complete all as specified and directed.
Mild steel 300 mm, ordinary rat tail rod pattern spring, including roller and roller plate including fixing to steel frame complete all as specified and directed.
Stainless steel tubing of 25 mm dia, min 1.0 mm wall thickness as in curtain rod complete incl 02 Nos stainless steel brackets/finials fancy type, stops fixed with SS screws etc complete fixed in repair complete all as specified and directed. Note : For the purpose of mesurement and payment running length of curtain rod only shall be considered.
Ball catches with 8mm dia steel ball and brass body or magnetic catcher with striking plate including letting in and fixed complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Cutting chases to brick wall built in cement mortar, pinning in,making good to facings where required and pointing in CM 1:3 to edges of landing, steps, cills ,sunsheds, shelves, lintel etc and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the engineer - in- charge
GI tubing 15mm bore medium grade with all fittings and fixed to wall and ceiling or laid in floors complete all as specified and directed.
GI tubing 20mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
20mm bore gun–metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in repair complete all as specified and directed.
15mm bore gun–metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
15mm bore long body bib taps, cast copper alloy, fancy type, chromium plated screwed down, screwed for iron pipe or for brass ferrule fixed in repair complete all as specified and directed.
15mm bore brass sink mixer chromium plated, screwed down, fancy type high pressure, with or without lettred 'HOT or COLD' with long screwed shank and fly nuts fixed in repaircomplete all as specified and directed.
15mm bore brass sink mixer with telephonic shower chromium plated, screwed down, fancy type high pressure, with or without lettred 'HOT or COLD' with long screwed shank and fly nuts, fixed in repair complete all as specified and directed.
15mm bore pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down, fancy type high pressure, with or without lettred 'HOT or COLD' with long screwed shank and fly nuts fixed in repair complete all as specified and directed.
15mm bore brass WHB mixer chromium plated, screwed down, fancy type high pressure, with or without lettred 'HOT or COLD' with long screwed shank and fly nuts fixed in repair complete all as specified and directed.
Stop valve /angle valve chromium plated fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed.
Concealed stop cock chromium plated fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed.
PVC connection 15mm size with PTMT nuts, of length 600mm complete all as specified and directed.
Sink with draining board, made out of Stainless steel 1 mm thick sheet for kitchen or laboratory with plug, waste pipe, brass chromium plated coupling and waste; including bedding in cement mortar on dwarf wall or fixing on & including cantilever brackets and connecting union to pipe overall size 495mmx420mm with bowl size 410mm x 330mm x 160mm, fixed in repair, complete all as specified and directed.
Vitreous china wash basin white, flat back, size 550x400 mm including cutting for pinning in ends of brackets or erecting stand, including 32mm bore PVC corrugated waste pipe 900mm long, 32mm bore waste coupling chromium plated, long screwed shank and fly nuts etc, fixed in repair, complete all as specified and directed.
Vitreous china squatting pan, "Orissa pattern" of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, flushing pipe, anti syphonage pipe incl P/S Trap etc fixed in repair,complete all as specified and directed.
Vitreous china squatting pan, pedestal pattern white including P trap connection to drain and flush pipe , seat cover closed pattern and anti syphonage pipe, fixed in repair complete all as specified and directed.
Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, fixed in repair, complete all as specified and as directed by engineer-in-charge
Supply and fixing 10 litre capacity virgin polypropylene cistern, coloured at low level complete with PVC bend/flush pipe and making all connection including taking down existing high or low level unserviceable flushing cistern and making good the disturbed surface to match with the existing surface, complete all as specified and directed.
Stainless steel grating 100mm dia with or without waste hole, fixed in repair, complete all as specified and directed.
15mm bore shower rose chromium plated 125mm dia alongwith 15mm bore shower arm 195 mm long with bend of 45 degree complete all as specified and directed.
160x160x90 mm size brass chromium plated soap dish hold
er and fixed with fixed in repair brass screws to wall complete all as specified and directed.
Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges, fixed in repair complete all as specified and directed.
PVC corner shelf (set of three) 8mm thick including railing radius 250mm, fixed in repair complete all as specified and directed.
CP toilet paper holder with flat recessed type stainless steel fixed to walls with chromium plated brass screws, fixed in repair complete all as specified and directed.
Demolition of brickwork built in cement mortar including all quioins, arches, pillars etccomplete all specified and directed by Engineer-in Charge.
Brickwork with sub–class 'B' bricks, straight or curved on plan to any radius, in foul position/manholes, built in cement mortar 1:6 complete all as specified and directed.
Factory made precast RCC manhole covers with frame (Type A–1, 1:2:4, using 20 mm graded stone aggregates), of different sizes with plain faces, including 3mm thick mild steel flat sheet all around , mild steel handle 02 No and including reinforcement, including demolition of existing manhole cover complete all as specified and as directed.
Reinforced cement concrete Design mix M-25 (20mm graded crushed stone aggregate) in roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
RCC Design mix M-25 (12.5mm graded crushed stone aggregate) in chajjas Kitchen Slab, Tank Staging and like complete all as specified and directed.
Mild steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hopping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0,.9mm dia or screwing with clip etc. complete all as specified and directed.
TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed
Form work to sides of concrete foundations, footings, bases of columns, plinth beams and similar work vertical or batter for flat rough finished surfaces of concrete.
Formwork to soffits of chajjas, finished rough surfaces of concrete flat complete all as specified and directed
Taking down PVC /cast iron/RCC drain pipes /rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan–necks, etc., including cleaning for refixing or removal to store, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed in wall including all fittings (bend,branch piece,tee & coupler etc ) complete all as specified and directed.
110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/ floor including all fittings (bend,branch piece,tee & coupler etc ) complete all as specified and directed.
110 mm bore PVC cowls 110mm bore complete all as specified and directed
75mm bore PVC (SWR) pipes single socketed including all necessary fitting bend, tee, single Y etc. in any length with rubber ring joints, fixed to walls complete all as specified and directed.
75mm bore PVC (SWR) pipes single socketed including all necessary fitting bend, tee, single Y etc. in any length with rubber ring joints, laid in floor /trenches complete all as specified and directed.
110 mm PVC(SWR) floor trap with grating includingjointing to waste pipe incl fixed in cement concrete type B–1 (1:2:4), fixed in repair complete all as specified and as directed.
PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, fixed in repair all as specified and directed.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing surplus excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
PVC (SWR) pipes, 150 mm dia bore laid and jointed in trenches complete with collars including all fittings (bend,branch piece,tee & coupler etc ) complete all as specified and directed.
PCC 1:4:8, type D–2 concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
PCC 1:4:8, type D–2 (using 40mm graded crushed stone aggregates)as foundation filling & mass concrete etc complete all as specified and directed.
PCC 1:5:10 type E–2 using 40mm graded crushed stone aggrgate as in filling in sunken portion floor, including demolition of old PCC and removing off the premises complete all as specified and directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for etc complete all as specified and directed.
Sunken floor water proofing treatment complete as under, complete all as specified and directed :– (a) Scrapping the surface of entire sunken floor with wire brush and cleaning with water and allowed to dry. (b) Applying cement slurry @ 3 kg/sqm duly mixed with liquid water proofing compound. (c) 15 mm thick cement plaster 1:3 mixed with liquid water proofing compound as per manufacture instruction
(the corners will be made rounded in concave shape). (d) Apply one coat of hot bitumin grade 85/25 conforming to IS 702 @ 1.5 kg/sqm. (e) Supply and laying APP membrane with non woven polyster reinforced sheet 3mm thick (weight not less than 3.00 kg/sqm). (f) Applying one coat of hot blown bitumen grade 85/25 conforming to IS–702 @1.50 kg/sqm. (g) Curing the sunken portion with water for minimum 48 hours by ponding.
40 mm bore GI pipe medium grade as in spout pipe complete all as specified and directed.
Cutting into existing manhole for connecting into new drain, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section), in cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate, smooth finished and reforming benching as required for 75/110/100 mm bore PVC pipe, complete all as specified and directed.
Dismantling boarding, any description, with grid of any type/ size as in CB / Wardrobes/ false ceiling or fixed in any position in hardware (if any) etc complete all as specified and directed.
Stainless steel kitchen plate rack made out of 0.85mm thick stainless steel of grade SS204 of size 24"x30"x10" including screws and fixing arrangements complete all as specified and directed
Cabinet of PVC premium quality with looking mirror, size 450mm x 600 mm box type including all as necessary items with chromium plated brass screws fixed to wall complete all as specified and directed. Make PRAYAG, CERA, Neelkamal.
Lead free PVC Celuka ply 18mm thick (Minimum density 650 kg/Cum) of both side plain white colour, fixed with stainless steel screws, solvent cement /adhesive to make kitchen /bed room cabinet sides top and bottam and shelves inside the cabinets complete as per manufacture's specifications and fixed in repair complete all as specified and directed.
Lead free PVC Celuka ply 18mm thick (Minimum density 650 kg/Cum) of single side rigid lamination of approved colour and other side plain white colour, fixed with stainless steel screws, solvent cement /adhesive to make kitchen cabinet shutters and shelves complete as per manufacture's specifications and fixed in repair complete all as specified and directed.
Lead free PVC Celuka ply 24mm thick (Minimum density 650 kg/Cum) of single side rigid lamination of approved colour and other side plain white colour, fixed with stainless steel screws, solvent cement /adhesive as in shutters of kitchen cabinet/CB and pull out drawer visible side complete all as specified and fixed in repair and directed.
Stainless steel 304 grade wire basket of size 386 x 500 x 100mm premium quality fixed in position, fixed in repair complete all as specified and directed
Stainless steel 304 grade wire basket of size 386 x 500 x 150mm (plain basket) premium quality fixed in position complete all as specified and directed
Stainless steel 304 grade wire basket of size 386 x 500 x 200mm (for plates) premium quality fixed in position in repair complete all as specified and directed
Ball bearing runners 450mm telescopic (KA4732) full extension load capacity minimum 35 kg, fixed in repair complete all as specified and directed by EIC
D' type cabinet handles premium quality, stainless steel grade 304, SN finished 150mm long matt finished complete all as specified and directed.
Auto closing hinges of size 35mm of 0 crank (KH–001) of 8 crank (KH–002) openable at 110 degree for kitchen cabinet shutters complete in all respect and fixed in position complete all as specified and directed.
25 Sqmm 4 Core service cable XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power 1100 Volts grade with stranded aluminium conductor laid in trenches complete all as specified and directed.
Each Set
Each Pipe
Each Pair
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed.
Taking down ceiling fan any size or any type and deposited to AGE E/M store yard complete all as specified and directed.
Taking down exhaust fan any size or any type and deposited to AGE E/M store complete all as specified and directed.
Taking down old unserviceable/serviceable single or three phase electric meter and deposited to AGE E/M store complete all as specified and directed.
Taking down of water heater any type/ size / capacity with all acessories after removing of all connection and deposited to AGE E/M store for repair complete all as specified and directed.
Taking down old and unsrevicable MCB DB TPN/SPN/metal clad socket and making good the disturbed surface all as directed specified and directed.
Taking down old and unsrevicable MCBs any size any type all as directed specified and directed.
Taking up old unserviceable earthing of any type complete all as specified and directed.
Per point
Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor, drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed in wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches/socket outlets etc complete all as specified and directed by Engineer-in-Charge for the following :- Note :- a) Cost of cutting/chases for concealing of conduit shall be deemed to be included in quoted rate. All chases will be cut by mechanical chase cutter only. b) Switch, socket outlet and fan regulators to be measured and paid for separately .
(a) One light point /fan point/exhaust fan point/bell point controlled by one, 1-way switch and fan regulator.
(b) socket outlet 3 pin, 5 Amp on independent board.
(c) Socket outlet, 3 pin, 5 Amp on the same board with other switches.
(d) One light point controlled by two, 2-way switches.
All as per srl item No 181 here-in-before but for one socket point 15 Amp with 2.5 sq mm PVC unseathed FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.5 sq mm green colour FRLS-H, 1100 volt grade ISI marked copper wire as earth contuinity conductor connected to common earth dolly.
All as per srl item No 181 here-in-before but for one socket point 15 Amp with 4.0 sq mm PVC unseathed FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.0 sq mm green colour FRLS-H, 1100 volt grade ISI marked copper wire as earth contuinity conductor connected to common earth dolly.
Modular Switch 1-way 6 Amp one module complete all as specified and directed.
Modular Switch 1-way 16 Amp one module ISI Marked complete all as specified and directed..
Modular Switch 2-way 6 Amp one module complete all as specified and directed.
Modular Bell Push 6 Amp one module complete all as specified and directed.
Modular Socket 6 Amp 5 Pin 2 Module complete all as specified and directed.
Modular Socket 6/16Amp 6 Pin 2 Module complete all as specified and directed.
Modular fan Regulator step type 2 module complete all as specified and directed.
Ceiling rose surface backlite 65 x 20mm size three terminal complete all as specified and directed.
Electric bell AC, ding-dong type, 230 Volt, single pole complete all as specified and directed.
Lamp holder suitable for batton fitting insulated body with back plate complete all as specific & directed.
LED batten fitting 18-20 watt, 4 feet, aluminium housing with electronic driver cool/warm type industrial model complete, connecting with copper conductor flexible
cable from ceiling rose to connector of the light complete all as specified and directed.
LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, industrial model, IP 65, aluminium housing, surge protection including driver and LED lamp, etc. complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and directed.
Surface mounted wall Mirror LED light Compact & sturdy 10 watt LED decorative fixture with anti glare polycarbonate diffuser, multi purpose lighting solution & applications .all accessories & fixtures, internally prewired and connecting by provding copper flexible wire 23/.0076 mm twin core upto fitting, complete all as specified and directed.
LED light fitting 9/12 watt wall mounting fixture (Sketch Type), in wooden housing, suitable for retrofit LED lamp compact and energy efficient epoxy powder coated light luminaire complete all as specified and directed.
LED Building Security Light Fitting of capacity 35-45 watt made up of die cast cast aluminium housing with balck epoxy powder coating with cover, heat resistance glass, input voltage range 170 to 270 volt, with IP-66 protection and other connected accessories including service bracket of MS pipe 25/32 mm bore of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting to MS pipe as required at site and making electrical connection complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps complete all as specified and directed.
MCB DB 4 way TPN double door powder coated complete with 200 Amp rated bus bar, 415 Volts rated bus bar IP 43 protection, suitable for MCB 4 Pole 63 Amp as incommer complete all as specified and directed. Note: Thimble/lugs of rating of MCB TPN should be used with wire for fixing in the MCB.
MCB TPN 63 Amps, 440 volt,10 KA 'C' curve complete all as specified and directed.
Sheet metal MCB DBs 12 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block, including copper lugs/thimbles duly crimped for connection, complete all as specified and directed.
Sheet metal enclosure MCB DB, SPN, 240 volts, 4 way, double door type grouting in wall in cement mortar making good of disturbed surfaces and matching with existing and electrical connections complete all as specified and directed.
MCB SP 6-40 Amps, 240 volt,10 KA 'C' curve complete all as specified and directed.
MCB SPN 6-32 Amps, 240 volts, 10 kA B Curve complete all as specified and directed.
MCB SPN 40-63 Amps, 240 volt,10 KA 'C' curve complete all as specified and directed.
Sub class ‘B’ old size bricks laid flat adjacent to each other with width equal to the length of the brick, laid perpendicular to the direction of cable in trenches for protection of cable all as specified and directed.
Hanging only ceiling fan after cleaning & painting in any model/size etc and making all connection using three core copper conductor flexible cable of size 1.5 sqmm including drawn through and including PVC flexible conduit pipe from ceiling rose to fan connector complete all as specified and directed.
Fixing only exhaust fan, any model/size etc and making all connection using three core copper conductor flexible cable in size 1.5 sqmm including drawn through and including PVC flexible conduit pipe from ceiling rose to fan connector complete all as specified and directed.
Fixing only of water heater any type and any size/capacity with all accessories such as nut bolt washers ,PVC pipe etc with making all connection using three core copper conductor flexible cable drawn through in PVC flexible conduite pipe including painting with two coats of super enameled paint of existing shade complete all as specified and directed.
Fixing only of serviceable electronic energy meter 5 to 30 Amps capactiy including connections complete all as specified and directed.
Sub main wiring with two run of 4X10 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volt grade ISI marked with multi stranded copper conductor with one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor connected to common earth dolly including capping & casing or concealed in wall/ceiling in PVC conduit medium grade not less than 25 mm dia ISI marked of adequate size for housing the wires complete all as specified and directed.
Sub-main wiring with two single core FRLSH PVC insulated and unsheathed cable with stranded copper conductor of 6 Sq mm drawing in & excluding PVC concealed conduit ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional wire of 6.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron. Earth wire protected by GI pipe 15mm bore (medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing on completion complete all as specified and directed.
PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in coping of road cutting / hard standing complete all as specified and directed.
PVC conduit 15mm dia with 1 run of 1.5 Sqmm copper wire drawn through including cutting and chasing in wall and accessories such as bend, T, socket etc for invertor circuit complete all as specified and directed.
LED lamp 9 watt suitable for battern holder complete all as specified and directed.
MCCB DB 4 way TPN double door powder coated complete alongwith 200 Amp rated Bus bar, 415 Volt rated bus bar IP 54 protection, suitable for MCCB 4 Pole 63 Amp as incommer complete all as specified and directed. Note: Thimble/lugs of rating of MCB TPN should be used with wire for fixing in the MCB. complete all as specified and directed.
MCCB 4 pole 415 V fixed type 63 Amp suitable for VTPN DB with breaking capaity 16KA complete all as specified and directed.
Supply and fixing modular TV Socket complete all as specified and directed.
Per 1000 Nos.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TenderFinal.pdf
Tender Documents • 1.55 MB
BOQ_812657.xls
BOQ • 3.48 MB
CORRIGENDUM05T13.pdf
PDF • 0.10 MB
CORRIGENDUM04.pdf
PDF • 0.10 MB
CORRIGENDUM03.pdf
PDF • 0.10 MB
CORRIGENDUM02.pdf
PDF • 0.10 MB
CORRIGENDUM01.pdf
PDF • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .