Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.6 LAccepted-AOC | ₹14.6 L | 1 | Accepted-AOC allotted |
| 2 | 2₹14.6 L+₹3,156.07 (0.22%)Rejected-Finance | ₹14.6 L+₹3,156.07 (0.22%) | 2 | Rejected-Finance 2nd lowest |
Tender Value
₹15.4 L
EMD Value
₹30,840
Closing Date
6 Jun 2020, 5:00 pmClosed
HEMANT KUMAARR
PWD NARAINGARH
Special Repair to Sub Health Centre at Village Karasan, Korwa Khurad and Salola to HWC in Ambala Distt.
2020_HRY_119746_3
HWC-1
Open Tender
Civil Works - Buildings
Works
90 days
IN AMBALA DISTT
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Public Work (B and R) Department
₹30,840
20 Aug 2020
6 May 2020
8 Jun 2020
6 May 2020
6 Jun 2020
6 May 2020
Amount
Dismantling of Brick work & Tile terracing ( HSR 8.5 b)
Terracing consisting of tiles 22.86 cm X 11.43 Cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and on other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc., (HSR 13.13).
Cement Concrete 1:2:4 gola 10cm x 10cm quadrant along junction of roof with parapet wall finished smooth, where specified. (HSR 13.64).
Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction, including disposal of all surplus soil as directed within a lead of 30 Mtrs. (HSR 6.6)
Cement concrete 1:8:16 with stone aggregate 40 mm Nominal sie in foundation and plinth. (HSR 10.28)
Cement concrete 1:4:8 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.38)
Cement Concrete 1:2:4 with stone aggregate 20 mm nominal size if first storey upto 4 metres above plinth level. (HSR 10.59).
Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work in Shelves excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respect. (HSR. 10.81+10.95 (a)). First Storey
First class brick work laid in cement sand mortar 1:4 in foundation plinth. (HSR 11.4)
First class brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. (HSR 11.9)
15mm Thick Cement Plaster 1:4 on the rough side of single or half brick wall. (HSR 15.10).
Base course of floors consisting 100mm thick cement concrete 1:8:16 and 100mm sand or stone filling (HSR.14.1)
Screed 50mm thick C.C. 1:8:16 to be laid below topping Second Storey (HSR.14.4)
Precast chequered tiles of 20 mm thickness In ordinary grey cement without chips laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps and landings. (Note:- Reputed make Tile Only ISI marked will be used as approved by Engineer-in-charge). (HSR 14.45+Note). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
Providing & fixing ceramic tiles/anti skid tiles of size 400mm x 400mm or above size of approved make in flooring, laid in any pattern as specified over base of 20 mm thick cement coarse sandmortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like:- RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL shall be used as approved by Engineer-in-charge. (HSR 14.91). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
Providing & Fixing Ist quality Ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manu-facturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-In-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete. (b) Size of ceramic Glazed tiles 300 x 450 mm of reputed manufacturer like:- RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL shall be used as approved by Engineer-in-charge. (HSR 14.92(b)). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
Factory manufactured panelled door or glazed windows shutters of commercial hard wood such as Hollock, Champ, Chikrassy & Chaplash only. (non coniferous timber other teak, confirming to I.S. pecificationNo. 1003, Kiln seasoned) with 100mm wide vertical styles, 150mm wide lock rail 200 mm wide bottom rail, and 100mm wide other rails, with panels of 15mm thick, tongued and grooved of commercial hard wood and including cost of iron hinges, screw, chock/cleats, stops nails etc. complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position). (a) 30 mm thick. (HSR 17.90 (a) - Note 1 under 17.18).
Factory manufactured wire gauze door and window shutters of commercial hard wood such as Hollock, Champ, Chikrassy & Chaplash only. (non-coniferous timber other teak conforming to I.S. specification No. 1003, kiln seasoned) with 100 mm wide vertical styles, 150 mm wide lock rail 200 mm wide bottom rail, and wire gauze of 140 G or 120 G designation including cost of iron hinges, screws, chock/cleats, stops nails etc., complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position. (Styles and rails of windows shutter shall be 75 mm wide. (i) 30 mm thick. (HSR 17.92 (i) - Note 1 under 17.18)
Pressed steel sheet frames (chowkhats) consisting of 2mm thick steel sheet of the specified section, including iron lugs (hold fasts) iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete. (HSR 18.34). (b) door and window frame Size of 76 mm x 38 mm with 35 mm wide single rebate.
d) door and window frame size 114 mm X 50 mm with 35 mm wide double rebate.
Preparation of ply wood surface for painting inlcuding sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. Painting on wooden surfaces etc. (HSR 16.1)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.2).
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.3).
Applying priming coat with metal primer on new steel or iron work including preparation of surface. Painting on mettalic Surfaces etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.9).
Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (Note:- reputed make Putty such as J.K./ Birla shall be used as approved by Engineer-in-charge). (HSR 16.81)
Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.58).
Providing two coats of exterior acrylic emulsion paint. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). [HSR 16.79 (b)].
Providing & Fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (Note:- Reputed make PVC Pipe such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. (HSR 13.89). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. (a) 100 mm dia PVC pipe 6 kg. pressure.
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12).
Providing and Fixing HDPE WATER STORAGE TANKS of Sintex, Diplast, O.K. Supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow and scour provisions with suitable plug on scour pipe including cost of nipples, washers flages for connections in tanks complete in all respects to the satisfaction to the Engineer-in-Charge. [HSR 30.119]. 1000 Ltrs. Capacity Water Tank
Providing & fixing in position C.P. brass stop cock (as approved by the engineer-in-charge). (a) 15 mm Stop cock. (ii) Concealed stop cock with flange. [HSR 30.76 (a) (ii)].
Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-charge). [HSR 30.75]. (a) Bib cock long body.
Providing and fixing in position best indian make (as approved by the engineer-in-charge European type water closet suite, syphonic type consisting of- (i) VITREOUS CHINAWARE SYPHONIC SUITE WITH 15 LITRES CAPACITY MATCHING CHINAWARE CISTERN and all internal brass fittings COMPLETE WITH ‘P’ or ‘S’ TRAP with or without vent; (as approved by the Engineer-in-charge). (ii) One piece SEAT AND LID IN HOLLOW BLACK OR WHITE PLASTIC fitted with chromium plated hinges and rubber buffers, (to the approval of the Engineer-in-charge) COMPLETE in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS. (b) Double trap syphonic (ii) Single Color. [HSR 30.5 (b) (ii)].
Providing & Fixing in position best indian make (ordinary) lavatory suites consisting of:- (v) Size 560 mm x 450 mm with one no. tap. [HSR 30.41(v)].
Providing & fixing in position best Indian make bevelled edge 5.5 mm thick mirror mounted on absetos sheet ground fixed in postion by means of 4 Nos. chromium plated brass screws and washers over rubbers washers and rawl plug embeded in the wall or chromium plated brass clamps with C.P. brass screws (as required by the engineer-in-charge) complete including cutting and making good the walls etc. (a) Indian Make (i) 600 mm x 450 mm. [HSR 30.71 (a) (i)].
Providing and fixing in position super quality 65 mm i/d opening C.P brass dome type hinged grating weighing about 750 gms fixed in cement mortar 1:2 complete in all respects (as required by the Engineer-in-charge). [HSR 30.74].
Providing and fixing in position best Indian make flexible tube connection. (b) C.P. Brass (iii) 15mm x 450 mm. (HSR 30.82 (b) (iii)).
Providing and fixing in position H.C.I. Soil waste vent or antisyphonage pipes to I.S.I. specifications of E.L.C. manufacture or of any other reputed firm including cutting and wastage etc. and cutting holes in walls, roofs or floor etc. and making good to its original condition but excluding cost of lead jointing. (HSR 30.84) (a) 100 mm internal diameter.
(b) 75 mm internal diameter.
Providing and fixing in position C.I. Gully trap cover weighing approximately 7.26 Kg. and frame for gully trap chamber clear opening size 300 mm x 300 mm and out side size 330 mm x 330 mm including painting the exposed surfaces with 3 coats of black bitumastic superior paint of approved manufacture etc. (HSR 30.85).
Providing lead caulked joints to H.C.I. pipes and specials confirming to I.S.I. specificationsof E.L.C. manufacture or any other reputed firm including cost of lead yarn, fuel and tools etc. (HSR 30.87). (a) 100 mm internal dia meter. (1.13 Kg)
(b) 75 mm internal dia meter. (0.91 Kg)
Providing & Fixing H.C.I. floor traps I.S.I. marked of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors, etc. minimum depth of water should be 50 mm with a minimum seal of 50 mm. (b) with 75 mm i/d outlet. [HSR 30.89
Providing and fixing in position H.C.I. specials for soils, waste, vent or anti-syphonage pipes to I.S.I. marked including cutting and waste etc. cutting holes in walls roofs or floors etc., and making good to its original condition but excluding cost of lead jointing. (HSR 30.91). (a) For 100 mm dia pipes (1) Heal rest bend
Cutting chase in brick wall in cement or in floor for embedding G.I. or H.C.I. pipe lines and making good the same to its original condition. (HSR 30.95 (a)). (a) Size 75 mm X 75 mm. (30.95 (a)).
(d) Size 225 mm X 225 mm. (30.95 (d)).
Providing and fixing in position automatic brass ball valves in tanks. (b) With Plastic Ball (ii) 20 mm internal diameter. (HSR 30.110 (b) (ii))
Providing & Fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150 mm x 150 mm cast iron cover weighing approximately 7.26 Kg. and frame clear opening 300 mm x 300 mm and outside size 330 mm x 330 mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:2:4, in coping black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150 mm with a minimum seal 50 mm. (b) 100 internal diameter H.C.I. gull trap. (HSR 30.114 (b)).
Providing for laying, jointing, fixing and testing G.I. (Medium class "B" type of Tata & Jindal make) pipe lines and specials tees bends, sockets, elbows etc. inside building and testing etc. complete including cutting threading. Including cost of Special. G.I. specials shall be of Make:- UNIK, TATA, ZOLOTO. (NS) (i) 15 mm internal diameter of pipeline
(ii) 20 mm internal diameter of pipeline
(ii) 25 mm internal diameter of pipeline
(ii) 32 mm internal diameter of pipeline
Providing for fixing and jointing union couplings in G.I. and W.I. pipelines. (NS). (a) 15 mm internal diameter
(b) 20 mm internal diameter
(b) 25 mm internal diameter
(b) 32 mm internal diameter
Providing SALT GLAZED STONE WARE PIPES GRADE 'A' IN STANDARD LENTH OF 600 MM EACH PIPE MARKED WITH IS;651 and their lowering, cutting, jointing and testing as described in HSR item no. 29.38, 29.39, 29.40 inlcuding the cost of jointing materials as well as carriage, loading, unloading, stacking handling, re-handling etc. complete in all respect to the satisfaction to the Engineer-in-Charge. (b) grade 'A' 150 mm. (HSR 29.95)
Constructing brick masonry road gully chamber as per standard drawings (as per sizes given below) including dressing of beds and sides of chamber to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item no 10.6) in foundation, Ist class brick work laid in cement sand mortar, 1:5, 40mm thick cement concrete 1:2:4, topping inside the chamber with a floating coat of 1.5 mm thick neat cement laid in one operation to the topping the entire inner surface of the chamber rendered with neat cement not less than 12 mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1 mm thickleft absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as specified in item no. 29.48 complete and to the requirement of the Engineer-In-charge). (a) Single Road Gully Chamber (i) Size 610 mm x 457 mm x 800 mm. (HSR 29.87 (a) (i)).
CONSTRUCTION OF RECTANGULAR STANDARD BRICK MASONRY MANHOLE CHAMBERS to standard drawings on S.W pipe sewers or other circular pipe sewers upto the required depth in 1.5 CEMENT SAND MORTAR, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium solicate on interior surface where required, reinforced cement concrete slab 180 mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. The rate cover the cost of M.S steel for R.C.C slab Labour for fixing and carriage of C.I manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also includes the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. Sodium silicate shall be supplied free of cost at the stores of Engineer- in-charge. (HSR 29.90 (ii)). (ii) On 150 mm I/d Pipe sewer (a) For 1.20 Mtrs. depth below ground level
Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning, trimming and dressing the trenches to correct alignment and grade as required by the Engineer-In-charge. (HSR 28.47 (a)). Upto 200 mm internal diameter
Providing, lowering, laying, cutting (cut surface to be uniformity finished) jointing with rubber rings marked with IS:5382 and testing of SPIGOT AND SOCKETTED RCC NP2 MARKED WITH IS:458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction to the Engineer -in-charge. (a) 200 mm dia. (HSR 29.93).
Providing and fixing SFRC manhole covers and frames markd with IS: 12592 including setting the same to correct lines and levels in 1:2 cement sand mortar over manhole including carriage loading, unloading stacking, handling, re-handling etc. complete in all respect to the satisfaction of engineer-in-charge. Type: Extra heavy duty set (MD-10) 560 mm clear opening. (HSR 29.94)
Providing and laying 60 mm thick ISI marked interlocking paver blocks (confermining to is 15658:2006) of all shapes and colours of design mix cement M-35 over a bed 25 mm thick fine sand complete in all respect(HSR 10.158)
Earth work non plastic or tibba sand under floor / road and parking taken from outside of campus area with all lead and lift including loading unloading (NS)
Sanjeev Jaswal Govt. Contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .