Loading…
Loading…
Tender Value
₹10.2 L
EMD Value
₹10,500
Closing Date
9 Oct 2026, 4:00 pm
Executive Engineer, Electric (R&B) Division, Rajkot
A&A to E.I. ,Ceiling Fan and Indoor Light Fittings in ITI Building at Dhoraji , Taluka:Dhoraji , Dist: Rajkot
348805
08 of 2026-27
Open
Electrical Works
Works
Rajkot
7 documents required · 7 mandatory
₹900
Executive Engineer, Electric (R&B) Division, Rajkot.
₹10,500
24 Sept 2026
24 Sept 2026
24 Sept 2026
9 Oct 2026
24 Sept 2026
Name of work: A&A to E.I. ,Ceiling Fan and Indoor Light Fittings in ITI Building at Dhoraji , Taluka:Dhoraji , Dist: Rajkot
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Replacing Old & u/s by Point wiring for Light / Bell with 2-
1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 kV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length , in below type of pipe erected with
6A Modular type switch / bell push & accessories and earth
continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame covered
with textured/metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed. (a) with
medium class Rigid PVC pipe and accessories erected flushed
on wall/ceiling complete Cat. III
Replacing Old & u/s by Point wiring for FAN with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 kV Grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe erected
with 6A Modular type switch and hum free EME step type
electronic fan regulator mounted and accessories with earth
2 73.00 Pt. continuity of following type erected on PVC / 765.58
Metallic/Wooden box, single mounting base frame covered
with textured/metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected. with necessary ceiling rose
/ H.D.Connector as directed.. (a) with medium class Rigid
PVC pipe and accessories erected flushed on wall/ceiling
complete cat-III
Replacing Old & u/s by Point wiring for Individual Plug with
& earth wire of 1.5 sq.mm (Green) both are of ISI marked
kV grade FRLS PVC insulated multi strand copper wires up to
10 mtr length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC /
3 17.00 Pt. Metallic/Wooden box covered with appropriate front plate 853.45
modules erected on / in wall / ceiling as per pipe erected with
following type of accessories.[II] For 16A Plug and 16 amp
switch with 2-2.5 sq.mm Cu. Wire from mcb db board. (a)
with medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete Cat. III
Replacing Old & u/s by Point wiring for on board Looped Plug
with 6A Modular type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate modules erected on
/ in wall / ceiling with following type accessories Cat. III
Providing & erecting PVC Corrugated Flexible Conduit with
5 100.00 Mtr. required nos. of coupling, PVC bushes, Check-nuts etc. 21.21
complete of following sizes.(2) 25 mm
Replacing Old & u/s by Providing and erecting Mains with
kV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected
concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour
for earth continuity of following size (A) With medium class
Rigid PVC pipe and accessories (b) 2 wire 2.5 sq. mm
providing and erecting Mains with 1.1 kV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in / on wall / ceiling with
7 60.00 Mtr. 2.5 sq. mm copper conductor FRLS PVC insulated stranded 184.83
wire of green colour for earth continuity of following size (A)
with medium class Rigid PVC pipe and accessories (b) 2 wire
providing and erecting Mains with ISI marked, 1.5kV grade
electrolyte multi stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS 694, IEC -
8 34.00 Mtr. erected in existing pipe of following size (Specifically for 115.14
control panel, relays, power switchgears, motor starters &
control wiring) with required size of copper lugs, nuts and
bolts if required.(f) One wire 10.00 sq. mm
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Providing & erecting Switch board for Computer or electric
apparatus consisting of following modular type accessories
mounted with PVC / Metallic concealed/open box with single
mounting base frame covered with textured/metallic /white
front plate,modules erected with necessary connections as
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type Accessories Cat. III
Replacing Old & u/s by Supplying and erecting LED indoor
fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high U.V. & corrosion
resistance with diffuser with company mark/name 160V to
270V, Power Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
10 300.00 Ea. Luminaire efficacy> 85 lumens/watt ,LED 535.30
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.) (A) Tube Light with integral
driver (v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet
Supplying and erecting led lamps with following wattage
capacity of 220 to 240 voltage, minimum 15000 burning hours
life, 500 V in built-surge protection,Polycarbonate diffuser,
11 24.00 Ea mounting suitable for E14 / E27 / B22 lamp holders, pf >= 0.5 188.87
(A) LED Lamps integral type, with PC diffuser suitable LAMP
holder (iii) 10 to 15 watts Cat-III
Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name engraved or
12 embossed 160 to 270 V,Power Factor more than 0.95, THD < 0.00
10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency >
85 %.( fittings required LM-79 & LM-80 certificates)(NOTE:
Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4kV integral and
6.00 Ea ,Light must have 440VAC line supply with over-voltage 6177.16
protection. (iv) 90 - 119 watts Cat-lll
Replacing Old & u/s by providing and erecting Miniature
circuit breaker single pole 6A to 25A suitable to operate on
13 170.00 Ea 240 V A.C. system and having breaking capacity 10 KA to be 123.22
erected in existing box. confirming to IS 8828/1996 with ISI
Replacing Old & u/s by Providing & erecting 240 V MCB
double pole switch for lighting Load (B Curve) having 10 KA
breaking capacity & confirms to IS : 8828 in existing box
having following capacity (A) 6 to 32 Amp. Cat.III
17.00 Ea (B) 40 Amp Cat.III 325.22
providing and erecting Approved make RCCBs conforming to
IS: 12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on
15 17.00 Ea single phase 240 V,50Hz. having characteristic of quick action 2458.34
& tripping with all advance feature & do not incorporate any
electronic component. for following Max. rating erected as
directed (ii) 40Amps. DP Cat. III
Providing and erecting Approved make RCCBs conforming to
IS: 12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on
phase and neutral 415V,50Hz. having characteristic of quick
action & tripping with all advance feature & do not incorporate
any electronic component for following Max. rating erected as
directed. (iii) 63 Amps. FP Cat. III
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Providing and erecting FRLS-XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Aluminium conductor for
17 95.00 Mtr. 1.1 kV. to be laid on wall with necessary clamps or in existing 151.50
trench / pipe of following size of cables (B) 4 core 6 Sq. mm
Supply, Installation Testing & Commissioning 10 Mtr. HDMI
Interface Cable as per the detailed Specifications supports
transmission of 4K Signals as per the detailed Specifications
Replacing Old & u/s by Providing & erecting Approved make
Power Saving 45 - 50 Watt Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt A.C. 50 Hz
mm sweep complete having 3blades with aluminium blades
with , canopy & 30 cm. down rod erected with earthing.(Make
shall be approved by Engineer in charge))
Replacing Old & u/s by Supplying and erecting 19 / 20 mm.
nominal bore Medium Class M.S. Pipe down rod erected duly
painted for fan complete with proper insulation without
leakage and earthing.
Providing & erecting water cooler having storage capacity
Ltr. & cooling capacity 150 Ltr.per hour @ an ambient temp of
45˚ C. The outlet temp. of the water should drop by 15˚C
within a hour, The water cooler should be comprising of
21 2.00 Ea hermetically sealed compressor, fan motor, condensing unit, 61482.74
water tank surrounded by evaporating, coil, thermostats, relay
etc.complete with necessary inlet & outlet connection. The
body of water cooler will be made from Stainless Steel and ISI
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Supplying & erecting 5 stage single reverse osmosis water
purification system with M.S. powder coated frame, prefilter
housing with 'O' ring presediment filter GAC filter, carbon
filter suitable buster DC pump capacity 80 psi, mention with
psi inline type post carbon filter auto low & high pressure
switches with following size of storage tank & LPH capacity &
erected as directed [C] 50 Ltr / Hr with 150 psi 2 nos booster
Note:- The Credit of dismentalled materials for Rs.27082.00 shall be recovered from the First R.A. bill payable to the contrator
and there after the dismentalled materials shall be the property of the contractor.
I/We am/are willing to carry out the work at__________________% above/below (in
figures)_____________________________________percent Above / below (in words) the estimated rates mentioned above amount of
my\our tender works out as under :-
Estimated amount put to Tender Rs. _________
Deduct________% below Rs. _________
Net Amount Rs. _________
Estimated amount put to Tender Rs. _________
Net Amount Rs. _________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local situation
regarding material,labour and other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications and other
tender documents of this work and agree to execute the same accordingly.
C Any Excess in Tender Item/Extra Item if Needs to be Execute. Contractors has to carry out work on the instruction of
Competant Authority on Tender Submitted rate,No Excuse will be Accepted.Hence Contractor are Requested to quote
the rate considering this condition.
D Contractor are requested to quote the Tender by considering that payment will be made after availibility of
grant.Contractor has to start the work immediately after issue of Work Order and as per instruction of Engineer-in-
Charge irrespective of availibility of grant.
E "This estimate has been prepared on the new SOR wich is exclusive of GST hence GST additional will be paid to the
agency as per existing guidelines."
(Signature of the Contractor)
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be considered
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ONLINE_NOTICE(R-2)(dn) DBD.pdf
SCH-B (1).pdf
ANNEXURE-A (1) (1).pdf
DM.pdf
MAKE FOR ELECTRICAL ITEM(upadatemake list).pdf
SCH-A (1).pdf
SBD.docx
DOCX
EMD GR.pdf
GR for Extra Item.pdf
GR for single Tender.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .