| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.4 CrAccepted-AOC CT PUBLIC SCHOOL PHAYAL KHASARA NO 597 JAKHOO MOHAL PHAIL SHIMLA HP | SHIMLA | HIMACHAL PRADESH | 170009 | ₹9.4 Cr Quoted ₹9.5 Cr | L-1 | Accepted-AOC Accepted |
| 2 | L-2₹9.6 Cr+₹10.7 L (1.12%)Rejected-AOC | ₹9.6 Cr+₹10.7 L (1.12%) | L-2 | Rejected-AOC Rejected |
| 3 | L-3₹10.5 Cr+₹95.1 L (10.0%)Rejected-AOC | ₹10.5 Cr+₹95.1 L (10.0%) | L-3 | Rejected-AOC Rejected |
| 4 | L-4₹11.2 Cr+₹1.7 Cr (17.6%)Rejected-AOC | ₹11.2 Cr+₹1.7 Cr (17.6%) | L-4 | Rejected-AOC Rejected |
Tender Value
₹10.0 Cr
EMD Value
₹10.3 L
Closing Date
21 Jun 2022, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Rampur
Providing WSS Bahli in GP Bahli Tehsil Rampur Distt. Shimla HP
2022_HPIPH_61712_1
JSD-RMP-TA-TEN/2022-2499-2549 DT. 13.6.22
Open Tender
Civil Works
Lump-sum
365 days
Rampur
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,500
EE Rampur
₹10.3 L
Yes
31 Dec 2022
15 Jun 2022
22 Jun 2022
15 Jun 2022
21 Jun 2022
15 Jun 2022
Amount
Cutting in earth work in all classification of earth work such as pick work, jumper work, saturated soil, blasting soft/ hard rock or chiselling soft/ hard rock where blasting is prohibited in all lifts including trimming and dressing of sides levelling of beds to correct grades including shoring, strutting, planking, timbering where ever required, stacking the serviceable/ unserviceable materials/soil separately complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Excavation in earth work and disposal of all excavated earth up to all leads and lifts, disposed earth to be levelled neatly dressed as per direction and to the entire satisfaction of the Engineer-in-Charge.
Excavation in foundation trenches etc.(for pipes & pits upto all depth) in earth work in all classification of earth work such as pick work, jumper work, saturated soil , blasting soft/hard rock or chiselling soft/ hard rock including wedging out of a rock where blasting is prohibited in all lifts including trimming and dressing of sides levelling of beds to correct grades including shoring, strutting, planking, timbering and dewatering where ever required, stacking the serviceable/unserviceable materials/soil separately and after laying and jointing of pipes, returning the usable soil in trenches in 15 CM layers including consolidation of each deposited layers by ramming and watering and then dispositng of all surplus excavated soil, useable materials as directed within all leads/lifts including restoration of metalled surfaces to its original condition and including cost of diversion for traffic night signals, fixing caution boards, crossing over trenches for access to houses fencing etc. complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Providing and laying cement concrete 1:5:10 ( 1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete in all respect with in all leads & lifts and as per the direction & to the entire satisfaction of the Engineer-in-Charge.
Providing and laying cement concrete 1:4:8(1Cement: 4Sand: 8Graded stone agg.40mm nominal size)& curing complete excluding cost of form work in foundation and plinth as per direction & to the entire satisfaction of the Engineer-in-Charge with in all leads and lifts .
Providing and laying cement concrete 1:3:6 (1Cement: 3Sand: 6Graded stone agg.40mm nominal size)& curing complete excluding cost of form work in foundation and plinth as per direction & to the entire satisfaction of the Engineer-in-Charge with in all leads and lifts .
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete 1 : 1.5 :3(1 cement :1.5 sand :3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcemnt for reinforced concrete work complete in all respect with in all leads and lifts as per the direction and to the entire satisfaction of Engineer-in-Charge .
Foundation and plinth complete as per the direction and to the entire satisfaction of the Engineer-in-Charge.
Walls (any thickness but not less than 0.10m thickness) attached pillaster, buttresses, plinth & string courses etc from top of foundaation level upto floor two level as per the direction & to the entire satisfaction of the Engineer-in-Charge.
In suspended floor roofs ,landing and shelves and their support.balconies , beams,girders, bressumers and contilever up to floor two level with in all leads and lifts.
Columns, pillars posts and struts upto floor two level.
Arches upto 6.00 mts. Span
Prov.form work with steel plates 3.15mm thick welded with angle iron frame 30 x 30 x 5mm so as to give a fair finish including centring, shuttering,strutting & propping etc. with wooden battens and ballies, height of propping & centering below supporting floor to ceiling not exceeding 4mtr.& removal of same for insitu rainforced concrete and plain concrete work complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge :-
Foundation,footing,bases of columns and the like & mass concrete.
Flat surfaces such as soffits & suspended floors, roofs, landing and the like. Floor etc. upto 200mm in thickness.
Vertical surfaces such as walls ( any thickness ) partition and the like including attached pillasters buttresses, plinth and string courses and the like.
Column , Pillers & post upto floor two level square, rectangular & polygonal in plain
Edges of slab and break in floor 20 cm wide
Arches upto 6.00 mts. Span
Extra for arches beyond 6.00 mts. Span
Side & Sofits of beams
Providing in RCC work smooth finishing of the exposed surface with Cement mortar 1:3 (1 Cement : 3 Sand) & as per direction & to the entire satisfaction of the Engineer-in-Charge.
Providing & laying No fine concrete with cement concrete 1 : 6 ( 1 Cement : 6 graded stone agg.20mm nominal size)and curing complete excluding cost of form work in wall etc. complete with in all leads & lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing mild steel / tor steel reinforcement for reinforced cement concrete work including bending, binding and placing in position complete upto floor two level complete in all leads and lifts and as per the direction and to the entire satisfaction of the Engineer-in-Charge. Tor Steel.
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position. 2nd. Class deodar wood.
Providing and /Fixing Pannelled & glazed shutters for doors windows and clear storey windows including bright finish black enamel led iron butt hings necessary screw 40 mm thick 2nd class deodar wood.
P/F wire gauge shutters using MS wire gause of IS gause designation 85 G for doors windows clerestory windows I/c bright finished black enameled iron hings with necessary screws 30 mm thick 2nd class deodar wood.
15 mm thick cement plaster on fair side of brick,stone masonary convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80 mm girth in cm 1:4 (1 cement:6 sand)
12 mm thick cement plaster in single coat on ceiling of RCC slab upto floor two level i/c arrises,internal rounded angles chamfers and/or rounded angles not exceeding 80mm in girth & finished even & smooth in C.M 1:3
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately
Steel work welded in built up section , trusses and framed work including cutting,hoisting,fixing in postion and applying a priming coat of red lead paint.
In gratings framed guard bars,ladders, railling,brackets and similar work. & as per direction & to the entire satisfaction of the Engineer-in-Charge
Providing and fixing M.S. grills of required patterns in wooden frames of windows etc. with M.S. Flats, square or round bars with round headed bolts and nuts complete including carriage of material within all leads and lifts and as per direction of Engineer-in-charge. (Oranamental Grill)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover
Manufacturing , Supplying & fixing of MS Man hole cover of size 60x60 cm Frame fixed with angle iron of size 40x40x5mm and top fixed angle iorn 25x25x5mm with MS sheet 3.15 mm thick including cutting. Welding and painting two coat with red oxide and making locking arrangement complete with reputed lock i.e Link/ Harison make (HEAVY DUTY) complete in all respect as per direction of Engineer-in-Charge.
Distempering (two coats) with oil bond distemper of approved brand and manufacture and of required shade on undecorated surface to given an even shade and including priming coat with distemper after throughly brushing the surface free from mortar dropping and other foreign matters
Painting over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil grease & dirt and other forgien matter
Painting on steel work with ready mixed paint brushing to give even shade including cleaning all dirt dust and other foreign matters white paint.
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size)
Providing /Fixing oxidised MS sliding door bolts with nuts and screw complete
(300 mm x 16 mm)
Providing /Fixing bright finished brass towers bolts barrel type with screw etc. complete
200mmx10mm
150 mm x10 mm
Providing /Fixing oxidised MS handle with screw complete
125 mm dia
100 mm dia
Constructing chamber for sluice valve, 1200x1200x1000 mm inside size laid in RCC top 1:2:4 mix (1 cement :2 sand :4 graded stone aggregate 20 mm nominal size) 100mm thick foundation concrete 1:5:10 mix (1cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortor 1 :3 (1 cement : 3 sand) finished with a floating coat of neat cement i/c curing complete. 600 x 600 x 750 mm inside size With 150 mm thick walls of RCC 1:2 :4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) complete with form work & reinforcement with 6 mm bars at not exceeding 150 mm centres both ways
Constructing chamber for sluice valve, 1500x1500x1000 mm inside size laid in RCC top 1:2:4 mix (1 cement :2 sand :4 graded stone aggregate 20 mm nominal size) 100mm thick foundation concrete 1:5:10 mix (1cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortor 1 :3 (1 cement : 3 sand) finished with a floating coat of neat cement i/c curing complete. 600 x 600 x 750 mm inside size With 150 mm thick walls of RCC 1:2 :4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) complete with form work & reinforcement with 6 mm bars at not exceeding 150 mm centres both ways
Providing & fixing PVC pipe 100 mm dia . nominal size for wheep hole complete within all leads & lifits and to the entire satisfaction of the Engineer-in-Charge.(Lead cauked joints to be measured & paid for separtely).
Wire crate made of G.I wire filled with boulders with square cut faces against the wire.(wire crate to be measuresd and paid for separetely)
Wire crate made of G.I wire filled with boulders with square cut faces against the wire. (boulder filling to be measured and paid for separately) G.I. Wire 4mm thick to SWG-8 15cmX15cm mesh. corresponding
Providing, Manufacturing, supplying and fixing of M.S. Angle 50x50x6 mm having 1.80 mtrs height and hold fast at bottom and fencing panal of size 1.20x 1.20 Mtrs of Jali of 14 gauge having 25x25mm mesh with M.S. Angle 40x40x5 mm including cutting welding and painting with red oxide paint followed by a cost of metal enamel paint to good exterior glistering look and rendering smooth with hold fast made of M.S. Angle 40x40x5 mm 4 nos complete in all respect and as per the direction and entire satisfaction of the engineer in charge.
1.80mt.height fencing with 2.5mt (50x50x6 mm) angle iron post ,2.50mt centre to centre with nine horizental lines and two diagonals of galvinised steel barbed wire) IS:278-1962 type-I) weighting 9.38kg per 100mt.(minimum) strained and fixed to post complete in all respect with CC 1:5:10 within all leads and lifts as per direction & to the entire satisfaction of Engineer-in-charge.
P/F MS gate as per standard design i.e MS square pipe clamps, pintal sets with pin clamps in cement concrete block (150x30x29 )complete in all respect with CC 1:5:10 within all leads and lifts as per direction & to the entire satisfaction of Engineer-in-charge.
Boulder filling behind retaining wall as per direction and to the entire satisfaction of Engineer -In-Charge.
Laying, jointing and testing in trenches to be levelled to grade galvanised mild steel pipe light grade of following nominal diameter including fittings complete in all respect to the entire satisfaction of the Engineer-in-Charge. ( Earth work in trenches to be measured and paid for separately).
15 mm nominal diameter.
20 mm nominal diameter.
25 mm nominal diameter.
32 mm nominal diameter.
40 mm nominal diameter.
50 mm nominal diameter.
65 mm nominal diameter.
80 mm nominal diameter.
Laying,jointing & testing of G I Pipe100 mm dia plain ended (Medium grade) having outer dia with bevelled edge i/c testing and commissioning and cost of jointing with butt welding ( Three layer)as per relevant BIS specification (leak proof) i/c cost of bend tail pieces, tees, reducers increaser etc. as per site requirement as per the direction of the engineer in charge and earth work in trenches to be measured and paid for seprately i/c all leads, lifts and carriage of materials at site.
Dismentelling of galvanised mild steel pipe light grade of following nominal diameter complete in all respect to the entire satisfaction of the Engineer-in-Charge. ( Earth work in trenches to be measured and paid for separately).
15 mm nominal diameter.
20 mm nominal diameter.
25 mm nominal diameter.
32 mm nominal diameter.
40 mm nominal diameter.
50 mm nominal diameter.
80 mm nominal diameter.
Relaying of galvanised mild steel pipe light grade including all fitting of following nominal diameter complete in all respect to the entire satisfaction of the Engineer-in-Charge. ( Earth work in trenches to be measured and paid for separately).
15 mm nominal diameter.
20 mm nominal diameter.
25 mm nominal diameter.
32 mm nominal diameter.
40 mm nominal diameter.
50 mm nominal diameter.
80 mm nominal diameter.
Prov. laying, Jointing and testing MSEW Pipe IS 3183 i.e 5L (standard) of graded L-1 grade A in trenches of below mentioned diameter in a radam length of 4-7 mtr, including anticorossive treatment, flanged joints at suitable reaches & remaining circumferencial butt welded joints by electrical arc welding to below mentioned dia , API pipe welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld confirming to IS: 816-1969 specifications by using welding electrodes of 2.50 mm to 6.30 mm of Advani orelikon ( Adore)- CITOJET / ESAB make, confirming to IS: 814-1991 at site of work complete in all respect including manual/ machinical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-charge ( The earth work in trenches , flanged joints at suitable reaches & circumferencial Butt welded joints by electrical arc welding to be measured and paid fo separately)
80 mm dia wall thickness 4.80 mm.
125 mm dia wall thickness 4.80 mm.
Providing & fixing full way valve with wheel of following diameter complete within all leads and lifts.
15 mm nominal diameter.
20 mm nominal diameter.
25 mm nominal diameter.
32 mm nominal diameter.
40 mm nominal diameter.
Providing & fixing double flanged CI Sluice valve PN. 1.6 (with hand wheel) as per IS : 780-1984 class-I upto 300 mm dia.(i/c brass spindle & as per 2906-1984 class-II for dia.> 300 mm) complete with bolts nuts,rubber insertion etc.,(the tail piece if required shall be measured & paid for separatly)
50 mm nominal diameter.
65 mm nominal diameter.
80 mm nominal diameter.
100 mm nominal diameter.
125 mm nominal diameter.
150 mm nominal diameter.
Providing & fixing Cast iron Air valve PN-1.6 of following diameter complete within all leads and lifts.
50 mm nominal diameter.
Water Treatment Plant (0.75 MLD)
C/O Water Treatment Plant (Rapid Sand Filter) including hydraulic and structural design and drawing, site development complete : Design, Construction and commissioning of Water treatment plant of 0.75 MLD capacity complete in all respect. The cost shall include all component viz. civil work, mechanical & electrical equipment, operation & maintenance, trial run for six month, site development, interconnecting arrangement and all other allied work.The cost shall include the construction of treatment units owing to scope of work, design parameter, term and conditions, technical specifications including all other works as per manual on water supply and treatment published by CHPEEO Ministry of Urban Development, New Delhi ( latest). The design of various components shall conform to design parameter given as per terms& conditions attached.
Supply errection, testing and commisioning of horizontal spindle,horizontal split, redial split Single/Multistage centrifugal pumps of standard make such as KSB/Mathar & Platt/Jayoti/Kirloskar confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle clear water having turbidity up to 50 ppm. with impelleres,casing ring performing funnel & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ mild steel to BHEL /Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c all leads an lifts and lifts as per entire satifaction of Engineer- in- charge.
2 Nos. Pump set ( i.e 1 No. working simultaneously & 1 No. Pump stand by
A) SITE CONDITIONS i) Location of site= Nehra (Badidhar) ii) The altitude of place in which the motor is untended to work in ordinary service if it exceeds 1000 Mt= 2515 Mtr. iii) Humidity= Whether generally remains clear during monsoon season. iv) Nature of atmosphere=As normally encountered in Himalyan Range v). Detail of quality of water= Clear cold water. vi) Water free from sand or not= Yes vii). Water corosive or not= Not viii). Turbidity (if any)= Up to 50 PPM ix). NPSH available= Positive suction. x). Any other information or requirement=
B OPERATING CONDITIONS i). Type of current= AC three/ single phase ii). Operating frequency= 50HZ iii). Rated voltage= 400(+/-)10%volts iv). System of earthing if any to to be adopted.= Double loop earthing as per BIS 3043-1987 latest with upto date amemndements v). No. of working hours per day= 8 hours vi). Speed of revolution in RPM= to be quoted by tenderer vii). Direction of rotation= to be quoted by tenderer viii). The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.= 30 Degree Centigrade
C) MOTOR i) Ref. to BIS code= BIS 325-1978 read with 900-1992 (latest) with upto date amendements. ii). Type of enclosure of motor= SPDP (as per BIS 4691-1985 (latest). iii). Type of duty= Continous iv). Mechanical out put in KW= Suitable for driving centifugal pumps re quired for duties specifiation against pumps to avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. v). Class of insulation= Class-B vi). Max.permissible temp.rise of motor reqd. if different from given in B(viii) above = ----- vii). Particulars of test reqd. & where they are to be conducted.= As per terms and conditions viii). Particulars as to whether voltage limiting divice will be employed= At S/star delta starter oil immersed fully automatic to be installe between bus bar & motor shunt capacitor is also proposed to be installed for improving the power factor at site. Note:- Star delta starter upto 37.5 KW ATS between 37.5KW to 50 KW & Starter rotor with sluip ring motor beyond 50 KW ix). Motor whether squirrel cage or slipring= Squirrel cage/slipring Note:-Squiareel cage upto 65HP and slipring above 65 HP x).Details of shaft extension reqd.= Just sufficient to prode diretc drive by flexible coupling to pump. xi). Type of slip ring gear whether continouly rated or for=Continously rated for squirrel cage/slipng starting purposes only & whether to be fitted with brush lifting or short circuting arrangements or both if interlocks are required. xii). Breakway torque in terms of rated l= Breakway torque to be given by the tenderer but the current which may be taken from the supply with the starting current should not exceed 2.5 of time of the starting apparatus in circuit. full load current, xiii). Nature of load & any information regarding the = Sufficient to work the pump offered driven machine which has a bearing upon the torque reqd.during the accelearted period, the kinetic energy of the moving parts to be accelarated & No.of starts during a specified period. xiv).. Where possible fault capacity of the system to which the motor is connected.= The motor should be able to withstand intial current of 2.5 times teh rated current for two minutes without suffering damages or permanent deformation.
D) PUMP (BIS 1520-1980)read with BIS 9137-1978 both latest with upto date ammendments a). Nos of pumps reqd.= 2 Nos pumps One will act as working & 1 No. stand by b). Spare parts required= For two years normal maintenance as recommended by manufacturer. c). Optional fittings reqd.= Air cock for exhausting air from each stage.
E) PUMP OPERATING CONDITIONS i). Capacity = 4.66 LPS for each pump. ii). Total head in Mtrs. If total head is not known then following details be provided:- 454.24 i)Static head /Discharde Head = 424.00 Mtr ii)Minimum depth of water= Positive suction. iii)Variation in water level=- ---Mtrs iv)Ground level to max.level= --Mtrs v)Ground level to delivery point= Mtrs vi)Pressure in the suction tank= Kg. cm/2 vii)Pressure in the delivery tank=Kg cm/2 iii). Length of R/Main= 1350 Mtr iv). Dia of R/Main= 80mm v). Drive arrangement= Direct through flexible coupling on a comman base plate vi). Drive type= Electric driven. vii0. NPSH reqd.= to be quotated by the tender viii). Limits of total head in which the pump is reqd. to operate.= (-)15% to (+)10% of total head ix). Suction/delivery size of pump= To be specified by the tenderer x). Efficiency of pump at= To be specified by the tenderer a) duty head= b) (+)10% head c) (-)15% head Material of construction= To be specified by the tendered (manufacturers certificate to be appended.
Providing & fixing suitable soft starter of approporiate rating for motor specified in technical specification for the purpose of controlled starting & stoping of pump with upper and Lower voltage and current limit i/c all leads an lifts and lifts as per entire satifaction of engineer in charge of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling as the case may be with single phase preventor as per IS 1246 (Part-1)-1963 with up to date ammendments.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.( Each pannel board comprising below mention accessories)
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen / Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with up to date ammendment i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
MCCB of appropriate capacity suitable for above specified capacity of Kilburn/LT/LK/MEI/ GEC/ Havells/ Diamond of standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with internal oil filling whenever required and neutral linked under voltage release i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Indicator for main ON-OFF system standby-overload run sump empty -full RYM phase i/c all leads and lifts as per entire satifaction of Engineer-In- Charge
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side compatible with automation system i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Hour run meter of reputed make of digit capacity conforming to BIS-722 latest edition / recommendation.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
Float type two point low/high level monitering system of water supply tank(sump well) integrated with programmable logic controller for dry run protection and automatic pump control i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Easy Fault Diagnostics with led disply for main supply missing or <75% phase loss reversal & other error, i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Automatic phase reversal rectifeir of appropriate capacity suitable for above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Frequency meter for AC Supply of appropriate capacity suitable or above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Motor protection circuit breaker for 3 phase/3 wire under voltage/over voltage protection , short circuit protection, overload protection,phase loss,phase reversal protection and motor disconnect function/ i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Rust free powder coated control panel suitable for housing all the above listed electric and electronic componnents i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of Kirloskar/Leader/KSB/ fouress/ pellicon/ Gled / BHEL make of cast steel double flanged Automated/ self actuated sluice valve having size one size higher dia than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump (including one No for common header) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 300 ASA (seat pressure 105 Kg/cm^2) as per BS 1414 ( MSERW -80 mm dia).
Providing and fixing of Kirloskar/Leader/KSB/ pelicon/Fouress make of suitable size cast iron/cast steel double flanged Automated/ self actuated swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 600 ASA (seat pressure 105 Kg/cm^2) as per BS-1414 ( MSERW pipe-80mm dia) .
Providing and fixing of Kirloskar/Leader/KSB/Pelocon/Fouress make cast iron flanged Automated / self actuatedv Sluice valve for suction pipe having size one or two size larger than suction size of pump such that valocity of flow is not more than 3.00 mtr/sec. with strainer of dia equal three to four times of dia of suction pipe conforming to BIS/API-standards or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The C.I sluice valve PN 1.6 as per IS 2906-1998).
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from Tranformer of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. i/c all leads an lifts and lifts as per entire satifaction of engineer (for 2 Nos. Pump Set. )
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,copper wiring & 32x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and fixing of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Prov and fixing cast steel double flanged Non Returning Valves of approved make makes such as Kirloskar, BHEL, Kilburn, KSB,Leader, GLED as per BIS 1868 including all leads and lifts complete in all respect.
80 mm dia ASA-300
MOHAN LAL THAKUR
Dogra Construction Company Pvt Ltd
HYDRAULIC ENGINEERING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
99946881.htm
Tender Document • 0.03 MB
99946882.htm
Tender Document • 0.03 MB
99946883.html
Tender Document • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .